  tesys ? iec-style contactors and starters file 8502 contents description page tesys iec contactors and starters selection guide. . . . . . . . . . . . . . . . . . . . . . . . . . 3 tesys k-line mini-contact ors, overload relays, and accessories . . . . . . . . . . . . . . 37 tesys d-line contactors, enclosed starters overload relays, and accessories . . . 77 tesys f-line contactors, overload relays, and accessories . . . . . . . . . . . . . . . . . 179 catalog number index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 catalog 04

catalog 04 tesys ? iec-style contactors and starters selection guide file 8502 contents description page technical information product standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 product approvals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 protective treatment according to climatic environment . . . . . . . . . . . . . . . . . . . . 10 degrees of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 kilowatt motor ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 horsepower motor ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 contactor selection guide definitions of utilization categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 contactor selection guide for util ization category ac-3 . . . . . . . . . . . . . . . . . . . . . 18 contactor selection guide for util ization category ac-1 . . . . . . . . . . . . . . . . . . . . . 22 contactor selection guide for utilization cat egory ac-2 and ac-4 . . . . . . . . . . . . . 24 contactor selection guide for utilization category dc-1 to dc-5 . . . . . . . . . . . . . . 28 voltage code table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 definitions and comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 selection guide
tesys? iec-style contactors and starters selection guide technical information: product standards ? 2001-2004 schneider electric all rights reserved 4 01/04 technical information: product standards conformity to standards the telemecanique d-line, f-line, and k-line contactors, overload relays and accessories satisfy most national, european, and international standards fo r promoting worldwide product acceptance. these product standards precisely define the performance of the designated products (such as iec 60947 for low voltage equipment). when used correctly, as designated by the manufact urer and in accordance with the regulations and rules of the art, these products will allow assemb led equipment, machine systems or installations to conform to their appropriate standards (for exampl e: iec 60204, relating to electrical equipment used on industrial machines). telemecanique is able to provide proof of conformity of its production, in acco rdance with the standards selected by ourselves, due to our quality assurance system. on request, and depending on the situation, telemecanique can provide the following:  a declaration of conformity.  a certificate of conformity (asefa/lovag).  an approval certificate or agreement, in the countries where this procedure is required or for particular specifications, such as th ose existing in the merchant marine. european en standards this is a group of technical specifications established in conjunction with, and approval of, the relative bodies within the various cenelec member countries (eec and efta). arrived at by the principal of consensus, the european standards are the result of a majority vote. such adopted standards are then integrated into the national collection of standards , and contradictory national standards are withdrawn. the european standards are now incorporated within t he french standards and carry the prefix nf en. under the ?technical union of electricity? (ute), the french version of the corresponding european standard carries a double notation: european reference (nf en ?) and classification (c ?). in addition, the standard nf en 60947-4-1 relating to motor contactors and starters, effectively constitutes the french version of the european standard en 60947-4-1 and carries the ute classification c 63-110. this standard is identical to the british standard bs en 60947-4-1 and the german standard din vde 0660 teil 102. whenever reasonably practical, european standards reflect international standards (iec). for automation system component s and distribution equipment, telemecanique supplements the requirements of the french nf st andards with those necessary for al l other major industrial countries. european directives the opening of the european market assumes a harm onization of the regulations pertaining to each member country of the european community. the purp ose of the european directive is the elimination of obstacles hindering the free circulation of good s within the european community, and its application applies to each member country. member countries are obliged to transcribe each directive into their national legislation and to simultaneously withdraw any contradictory regulation. t he directives, in particular those of a technical content concerning us here, only establish the objective s to be obtained and are referred to as ?essential requirements.? code standards body - name abbreviation country ansi american national standards institute ansi usa bs british standards institution bsi great britain cei comitato electtrotechnico italiano cei italy din/vde verband deutscher electrotechniker vde germany en comit europen de normalisation electrotechnique cenelec europe gost gosudarstvenne komitet standartov gost russia iec international electrotechnical commission iec worldwide jis japanese industrial standard jisc japan nbn institut belge de normalisation ibn belgium nen nederlands normalisatie institut nni netherlands nfc union technique de l'electricit ute france saa standards association of australia saa australia une instituto nacional de racional izacion y normalizacion iranor spain
tesys? iec-style contactors and starters selection guide technical information: product standards 5 01/04 ? 2001-2004 schneider electric all rights reserved the manufacturer is obliged to ensure that all m easures are taken to provide conformity to the regulations of the particular directive applicable to his product. as a general rule, the manufacturer certifies conformity to the essential requirements of the directive(s) for the product by affixing a ce marking. the ce marking will be affixed to telemecanique products progressively throughout the transition period, as defined by the french and european regulations. significance of the ce marking:  the ce marking is affixed to a product to signif y that the manufacturer certifies that the product conforms to the relevant european directive(s) and is obligatory for a product, subject to one or more of the european directives, before it can be fr eely distributed within the european community.  the ce marking is intended solely for national market control authorities.  the ce marking must not be confused with a conformity marking. for electrical equipment, only conformity to standar ds signifies that the product is suitable for its designated function, and only the guar antee of an established manufacturer can provide a high level of quality assurance. for telemecanique labelled products, one or several directives are liable to be applied, in particular:  the low voltage directive 73/23/eec amended by the directive 93/68/eec: the ce marking relating to this directive could not be affixed before 1 january 1995 but was obligatory as of january 1, 1997.  the electromagnetic compatibility directive 89/336 /eec, amended by the directives 92/31/eec and 93/68/eec: the ce marking on products covered by th is directive is obligatory from 1 january 1996. asefa-lovag certification the function of asefa (associatio n des stations d'essais fran?a ise d'appareils lectriques ? association of french testing statio ns for low voltage industrial electrical equipment) is to carry out tests for conformity to standards and to issue certificates and test reports. asefa laboratories are authorized by the national testing network (rne). asefa is now effectively a member of the european accord group lovag (low voltage agreement group). this means that any certif icates issued by lovag/asefa are recognized by all the authorities forming the membership of the group and carry the sa me validity as those issu ed by any of the member authorities. quality labels when components can be used in domestic and simi lar applications, it is sometimes necessary to obtain a ?quality label,? which is a fo rm of certification of conformity. approvals in some countries, the approval of certain electrical equipment is required by law. in this case, an approval certificate is issued by the official test authority. each approved component must bear the relevant quality label when this is mandatory. code quality label country cebec comit electrotechnique belge belgium kema-keur keuring van electrotechnische materialen netherlands nf-use union technique de l'electricit france ?ve ?sterreichischer verband fr electrotechnik austria semko svenska electriska materiel kontrollanatalten sweden code approval authority country ase association suisse des electriciens switzerland csa canadian standards association canada demko danmarks elektriske materielkontrol denmark fi s?hk?tarkastuskeskus elinspektions centralen (seti) finland nemko norges elektriske materiellkontroll norway ul underwriters laboratories inc. usa
tesys? iec-style contactors and starters selection guide technical information: product approvals ? 2001-2004 schneider electric all rights reserved 6 01/04 technical information: product approvals note on approvals issued by the underwriters laboratorie s inc. (ul) that there are two levels of approval: marine classifica tion authorities prior approval by certain marine classification author ities is generally required for electrical equipment which is intended for use on board merchant vessels. product approvals the table below shows the approvals obtained or pending with the various approvals authorities as of 5/15/1995. for more detailed information, please consult your local square d field sales office. level of approval symbol description ?recognized? the component is fully approved for inclusion in equipment built in a workshop, where the operating limits are known by the equ ipment manufacturer, and where its use within such limits is acceptable by underwriters laboratories inc.the component is not approved as a ?product for general use? because its manufacturing characteristics are incomplete or its application possibilities are limited. a ?recognized? component does not necessarily carry the approval symbol. ?listed? the component conforms to all the requirements of the classification applicable to it and may therefore be used both as a ?prod uct for general use? and as a component in assembled equipment. a ?listed? component must carry the approval symbol. code classification authority country bv bureau veritas france dnv det norske veritas norway gl germanischer lloyd russia lros lloyd's register of shipping great britain nkk nippon kaiji kyoka? japan rina registro italiano navale italy rrs register of shipping russia existing and pending approval of automation system components (except control and signalling units) standard version x : approved o : approval pending special version + : approved ? : approval pending approvals marine classification authorities quality labels ase csa demko fi nemko ul bv dnv gl lros nkk rina rrs kema nf ?ve semko switzer land canada denmark finland norway u.s.a. france norway germany great britain japan italy cis nether lands france austria sweden ab1bb, ab1bc x x x x x x x x ab1bd x x ab1dv x x x x ab1fu xxx xx x x ab1fv xx xx x ab1ne, ab1se x x x x x x ab1sv x x x ab1tp xx xxx xxx xxx x ab1tr x xx ab1vv xxxxxx xxx xxx xx ab3rv x aba6, abe6r o x abr1, abr2 x x x x x abs1 xx x abs2 x x x x x ak2ba01 x ak2ba162u x x ak2sb x ak3jb4 (cmd) xx x xxxxxo x ak3jb8 (cmd) x x x x x o x
tesys? iec-style contactors and starters selection guide technical information: product approvals 7 01/04 ? 2001-2004 schneider electric all rights reserved ak5 x xxxx at p o x at s 2 3 x x at v 1 6 , at v 6 6 x x ca2d xxxxx xxx x x ca2kn x x x xoooo oo x ca3d xxx x xxx x x ca3kn x x xoooo oo x ca4d x x x x x x x ca4kn x x x xoooo oo x ccx 17 o x o df6 x dk1 xx ftx 417 o x ftx 117 o o gb2cb x x x x x gb2cd x x gc1 xx xxxx gc3 x x gd2 x gv2m xx x xxxxx x ox gv2p x x gv3 x x x x gv7r x xoooo o gy1 x xx gy3 x x la1d xxx x xxxoo xx x la1kn x x xoooo oo x la1lb x x x o x o o x x la1lc xxxx xxxxxxxx la2d, la3d xx x xxxox xx x la2k, la4k x xoooo oo la4d xx xx oo xx la8d xx xx xx oo xx lblb xxxxx xoxoo xo xx lblc xx x xxxxxxxx lbld xx x xxxx xxx lc1d xxxxx xxxoo xx x lc2d xx xxxoo xx lc1f xx xxxoo xx lc1k x x x xoooo oo x lc2f x xxxoo xx lc2k, lc7k, lc8k x x xoooo oo ld1lb xxxxx xoxoo x x ld1lc xxx xxxxxxxx existing and pending approval of automation system components (except control and signalling units) standard version x : approved o : approval pending special version + : approved ? : approval pending approvals marine classificat ion authorities quality labels ase csa demko fi nemko ul bv dnv gl lros nkk rina rrs kema nf ?ve semko switzer land canada denmark finland norway u.s.a. france norway germany great britain japan italy cis nether lands france austria sweden
tesys? iec-style contactors and starters selection guide technical information: product approvals ? 2001-2004 schneider electric all rights reserved 8 01/04 ld1ld xx xxx xxxx ld4lc xxxxx xxxxxxxx x ld4ld xx xx xxxxxxxx ld5lb x x o x o o x o ld5lc xx x xxxxx x ld5ld x x x x x x x le1d x x x ln1d x x x x lp1d xxxxx xxxox x lp1k x x xoooo oo lp2d xx xxxoo x lp2k x x xoooo oo lp4d x x x x x o o lp4k x x x xoooo oo lp5d xx xx oo lp5k x x xoooo oo lr1f xx xxxxx xx lr2d xxxxx xxxoo xx lr2f xx xxxoo xx lr2k x xoooo oo lr9f x x ls1d x lt 2 s x x x lt 7 f x x x lt 8 x x x re1la, re1lc x x x re4, re5 x x x rh x xxx x rm1xa x rm3 x x x rs1, rs2 rtv74, rtv84 o o rxn, ruw o o o tsx 07 x x o tsx 1710/20 x xxxx xx k1, k2 x x x x x x xa2b, bv, bw x x xaca (small hoist) x x x x x x x xaca (all applications) + x x + x x x xacb x x xacm x xalb, xalj, xaln + x x + x x xapa + x x x x xapm + x + x x x x xase, xasp x existing and pending approval of automation system components (except control and signalling units) standard version x : approved o : approval pending special version + : approved ? : approval pending approvals marine classification authorities quality labels ase csa demko fi nemko ul bv dnv gl lros nkk rina rrs kema nf ?ve semko switzer land canada denmark finland norway u.s.a. france norway germany great britain japan italy cis nether lands france austria sweden
tesys? iec-style contactors and starters selection guide technical information: product approvals 9 01/04 ? 2001-2004 schneider electric all rights reserved xbla x x xbta, xbtk, kl, kn x x x x xbtb, xbtc + + xbth, xbtp, xbte, xbthm xx xbtm, ml x x o x xbtva + + xb2b (pushbuttons) x xxxxxxxx x x xb2bv, bw (direct) (via transformer) xxxxxxxxxx x x xb2bv, bw (reducer) xxxxxxxxxx x xb2ev x x xb2m (pushbuttons) xxxx xx x x xb2mw (direct) (via transformer) +xxx + x x xda, xdl x x xd2a, xd2c, xd2e + x x xd2pa, xd2ga x x x xpea x xpem + x xvac, xval x x xvla x x xy2cb, xy2ch x xy2ce + + za2va x x zb2mw (direct) (via transformer) +xxx + x x existing and pending approval of automation system components (except control and signalling units) standard version x : approved o : approval pending special version + : approved ? : approval pending approvals marine classificat ion authorities quality labels ase csa demko fi nemko ul bv dnv gl lros nkk rina rrs kema nf ?ve semko switzer land canada denmark finland norway u.s.a. france norway germany great britain japan italy cis nether lands france austria sweden
tesys? iec-style contactors and starters selection guide technical information: protective treatment / climatic environment ? 2001-2004 schneider electric all rights reserved 10 01/04 technical information: protective treatment according to climatic environment depending on the climatic and environmental conditions in which th e equipment is placed, telemecanique can offer specially adapted products to meet your requirements. in order to make the correct choice of protective finish, two points should be remembered:  the prevailing climate of the country is never the only criterion.  only the atmosphere in the immediate vicinity of the equipment should be considered. ?tc? treatment for all climates ?tc? is the standard treatment for telemecanique equi pment and is suitable for the vast majority of applications. it is the equivalent of treatments described as ?klimafest,? ?climateproof,? ?total tropicalization,? or ?super tropicalizat ion,? and meets the following requirements:  publication ute c 63-100 (method l), successive cycles of humid he at at + 40 c (104 f) and 95% relative humidity.  din 50016 ? variations of ambient conditions within a climatic chamber: + 23 c (73 f) and 83% relative humidity, + 40 c (104 f) and 92% relative humidity. it also meets the requirements of the marine classification authority bv-lros-gl-dnv-rina. characteristics  steel components are usually trea ted with zinc chromate and, when they have a mechanical function, they may also be painted.  insulating materials are selected for their high electrical, dielectric and mechanical characteristics.  metal enclosures have a stoved paint finish, appl ied over a primary phosphate protective coat, or are galvanized (for example, some prefabricated busbar trunking components). limits for use of ?tc? (all climates) treatment  ?tc? treatment is suitable for the following temperatures and humidity:  it may also be used where the above limits are only exceeded accidentally or for very short periods, or where temperature variations are not sufficien t or fast enough to cause heavy condensation or dripping water on the equipment. ?tc? treatment is therefore suitable for all latitudes, including tropical and equatorial regions, where the equipment is mounted in normal, ventilated industrial locations. being sheltered from external climatic co nditions, temperature variations are small, the risk of condensation is minimized, and the risk of dripping water is virtually non-existent. extension of use of ?tc? (all climates) treatment in cases where the humidity around the equipment exceeds the conditions described above, where the equipment (in tropical regions) is mounted outdoors, or where it is placed in a very humid location (laundries, sugar refineries, steam rooms, and so fort h), ?tc? treatment can still be used if the following precautions are taken:  the enclosure in which the equipment is mounted mu st be protected with a ?t h? finish (see page 11) and must be well ventilated to avoid condensation and dripping water (for example, enclosure base plate mounted on spacers).  components mounted inside the encl osure must have a ?tc? finish.  if the equipment is to be switched off for long period s, a heater must be provided (0.2 to 0.5 kw per square decimeter / 15.5 square inch of enclosure), switched on automatically when the equipment is turned off. this heater keeps the inside of the enc losure at a temperature slightly higher than the outside surrounding temperature, thereby avoiding an y risk of condensation and dripping water (the heat produced by the equipment it self in normal running is sufficient to provide this temperature difference). temperature 20 c (68 f) 40 c (104 f) 50 c (122 f) relative humidity 95% 80% 50%
tesys? iec-style contactors and starters selection guide technical information: protective treatment / climatic environment 11 01/04 ? 2001-2004 schneider electric all rights reserved  for pilot devices, the use of ?tc? treatment can be extended to outdoor us e provided the enclosure is made of light alloys, zinc alloys, or plastic materi al. in this case, it is e ssential to ensure that the degree of protection against penetrat ion of liquids and solid objects is suitable for the applications involved. ?th? treatment for hot and humid environments this treatment is for hot and humid atmospheres where installations are subject to condensation, dripping water, and the risk of fungi. plastic insulating components are also resistant to attacks from insects such as termites and cockroaches. these properties have led to this treat ment being described as ?tropical finish,? but this does not mean that all equipment in stalled in tropical and equatorial regions must have undergone ?th? treatment. on the other hand, cert ain operating conditions in temper ate climates may well require the use of ?th?-treated equipment (see the limits for use of ?tc? treatment section on page 10). the following are special charac teristics of ?th? treatment:  all insulating components are made of materials which are either resistant to fungi or treated with a fungicide, having increased resistance to creepa ge (standards iec 112, nf c 26-220, din 5348).  metal enclosures receive a top-coat of baked, fungicidal paint, applied over a rust inhibiting undercoat. components with ?th? treatment may be subject to a surcharge (a large number of telemecanique products are ?th? treated as stand ard and are, therefore, not subject to a price surcharge). please consult our local representatives or agents. special precautions fo r electronic equipment electronic products always meet t he requirements of ?tc? treatment. a number of them are ?th?-treated as standard. some electronic products (for example, programmab le controllers, flush-mountable controllers ccx, and flush-mountable operator terminals xbt) necessitate the use of an enclosure providing a degree of protection to at least ip 54 (as defined by the standa rds iec 60664 and nf c 20 040) for use in industrial applications or in environmental co nditions requiring a ?th? treatment. these electronic products, including flush-mountable products, must have a degree of protection to at least ip 20 (either provided by the enclosure itself or following installation) for restricted access locations where the degree of pollution does not exceed 2 (a te st booth not containing machinery or other dust producing activities, for example). protective treatment selection guide location environmental conditions duty cycle internal heating of enclosure when not in use type of climate protective treatment of components enclosure indoors no dripping water or condensation unimportant unnecessary unimportant ?tc? ?tc? presence of dripping water or condensation frequent switching off for periods of more than 1 day no temperate ?tc? ?th? equatorial ?th? ?th? yes unimportant ?tc? ?th? continuous unnecessary unimportant ?tc? ?th? outdoors (sheltered) no dripping water or dew unimportant unnecessary temperate ?tc? ?tc? equatorial ?th? ?th? exposed outdoors, or near the sea frequent and regular presence of dripping water or dew frequent switching off for periods of more than 1 day no temperate ?tc? ?th? equatorial ?th? ?th? yes unimportant ?tc? ?th? continuous unnecessary unimportant ?tc? ?th? these treatments cover, in particular, the applications defined by methods i and ii of guide ute c 63-100.
tesys? iec-style contactors and starters selection guide technical information: degrees of protection ? 2001-2004 schneider electric all rights reserved 12 01/04 technical information: degrees of protection iec publication 60529 classification of degrees of protection provided by enclosures provides a system for specifying the enclosure s of electrical equipment on the basis of the degree of protection provided by the enclosure. iec 60529 does not s pecify degrees of protec tion against mechanical damage of equipment, risk of explosions, or conditi ons such as moisture (produced, for example, by condensation), corrosive vapors, fungi, or verm in. nema standards publication 250, and ul 50 standard does test for environmental conditions such as corrosion, rust, icing, oil, and coolants. for this reason, and because tests and evaluations for other c haracteristics are not identical, the iec enclosure classification designations cannot be exactly e quated with nema enclosure type numbers. the iec designation consists of the letters ip followed by, usually, two numerals (for example ip 55). the first characteristic numeral indicates the degree of protection provided by the enclosure with respect to persons and solid foreign objects entering the enclosu re. the second characteristic numeral indicates the degree of protection provided by the enclosure wi th respect to the harmful ingress of water. see the tables below and on page 13 for what the two numbers mean. in addition, a single-digit letter may follow the two nume rals (for example, ip 20c). this letter indicates that the actual protec tion of personnel against direct contact with live parts is better than that indicated by the first numeral. so this example (ip 20c) indicate s that the device is finger-safe (the ?2?) and tool- safe (the ?c?) for tools 2.5 mm (or larger) in diamet er. see the table on page 13 for what letters are permissible and what each indicates. finally, a third numeral may sometimes appear and corresponds to the degree of protection against mechanical impact. in accordance with standard nf c 20-010, the third numeral may either follow the two ip numerals (for example, ip 55-9) or be shown separately from the ip code. this numeral also corresponds to an external factor classification as defined in standard nf c 15-100. see the table on page 13 for what numbers are permissible and what each indicates. note: any characteristic numeral which is unspeci fied is replaced by an x (for example, ip xxb). iec 60529 classification designatio ns ? first characteristic numeral first characteristic numeral corresponds to protection of the equipment against penetration of solid objects and protection of personnel against direct contact with live parts. protection of the equipment protection of personnel 0 not protected not protected 1 protected against the penetration of solid objects having a diameter greater than or equal to 50 mm (2?). protected against direct contact with the back of the hand (accidental contacts). 2 protected against the penetration of solid objects having a diameter greater than or equal to 12.5 mm (0.5?). protected against direct finger contact. 3 protected against the penetration of solid objects having a diameter greater than or equal to 2.5 mm (0.1?). protected against direct contact with a 2.5-mm (0.1?) diameter tool. 4 protected against the penetration of solid objects having a diameter greater than 1 mm (0.04?). protected against direct contact with a 1mm (0.04?) diameter wire. 5 dust-protected (no harmful deposits). protected against direct contact with a 1mm (0.04?) diameter wire. 6 dust-tight. protected against direct contact with a 1mm (0.04?) diameter wire. ? 50 mm ? 12. 5 mm ? 2,5 mm ? 1 mm
tesys? iec-style contactors and starters selection guide technical information: degrees of protection 13 01/04 ? 2001-2004 schneider electric all rights reserved the table below provides an equivalent conversion from nema enclosure type numbers to iec enclosure classification designations. the nema types meet or exceed the test requirements for the associated iec classifications; for this reason this table cannot be used to convert from iec classifications to nema types. the comparison is based on tests specified in iec publication 60529, and is from nema publication 250. iec 60529 classification designations ? se cond and third characteristic numerals second characteristic numeral corresponds to protection of equipment against penetration of water with harmful effects. additional letter corresponds to protection of personnel against direct contact with live parts. third characteristic numeral corresponds to the degree of protection against mechanical impact. this numeral also corresponds to an external factor classification as defined in standard nf c 15-100. 0 non-protected a with the back of the hand. 0 non-protected 1 protected against vertical dripping water (condensation). b with the finger. 1 impact energy: at least equal to 0.25 n ? m (external classification factor ag1). 2 protected against dripping water at an angle of up to 15. c with a 2.5-mm (0.1?) diameter tool. 2 impact energy: at least equal to 0.375 n ? m. 3 protected against rain at an angle of up to 60. d with a 1mm (0.04?) diameter wire. 3 impact energy: at least equal to 0.5 n ? m. 4 protected against splashing water in all directions. 5 impact energy: at least equal to 0.5 n ? m. 5 protected against water jets in all directions. 7 impact energy: at least equal to 6 n ? m (external classification factor ag3). 6 protected against powerful jets of water and waves. 9 impact energy: at least equal to 20 n ? m (external classification factor ag4). 7 protected against the effects of temporary immersion. 8 protected against the effects of prolonged immersion under specified conditions. conversion of nema type numbers to iec classification designations (cannot be used to convert iec classification designations to nema type numbers) nema enclosure type number iec enclosure classification designation nema enclosure type number iec enclosure classification designation 1 2 3 3r 3s ip10 ip11 ip54 ip14 ip54 4 and 4x 5 6 and 6p 12 and 12k 13 ip56 ip52 ip67 ip52 ip54 150 g (0.33 lb) 15 cm (6") 15 250 g (0.55 lb) 15 cm (6") 60 250 g (0.55 lb) 20 c m (8") 500 g (1.1 lb) 40 cm (16") 1.5 kg (3.3 lb) 40 cm (8") 5 kg (11 lb) 40 cm (8") 1m (39") 15 cm (6") min 1m (39")
tesys? iec-style contactors and starters selection guide technical information: kilowatt motor ratings ? 2001-2004 schneider electric all rights reserved 14 01/04 technical information: kilowatt motor ratings the tables below provide the average full-load curr ents of squirrel cage motors in accordance with iec conventions. these are given only as a guide ? they may vary depending on the type of motor and manufacturer. refer to the actual motor nameplate for full-load current values. single-phase motors 3-phase motors, 50/60 hz power 220 vac 240 vac power 230 vac 400 vac 415 vac 440 vac 500 vac 690 vac kilowatts a a kilowatts a a a a a a 0.37 3.9 3.6 0.37 2 0.98 ? 0.99 1 ? 0.55 5.2 4.8 0.55 2.8 1.5 ? 1.36 1.21 ? 0.75 6.6 6.1 0.75 3.6 1.9 2 1.68 1.5 ? 1.1 9.6 8.8 1.1 5.2 2.5 2.5 2.37 2 ? 1.5 12.7 11.7 1.5 6.8 3.4 3.5 3.06 2.6 ? 1.8 15.7 14.4 2.2 9.6 4.8 5 4.42 3.8 ? 2.2 18.6 17.1 3 ? 6.3 6.5 5.77 5 3.5 3 24.3 22.2 3.7 15.2 ? ? ? ? ? 4 29.6 27.1 4 ? 8.1 8.4 7.9 6.5 4.9 4.4 34.7 31.8 5.5 22 11 11 10.4 9 6.7 5.2 39.8 36.5 7.5 28 14.8 14 13.7 12 9 5.5 42.2 38.7 9 ? 18.1 17 16.9 13.9 10.5 6 44.5 40.8 11 42 21 21 20.1 18.4 12.1 7 49.5 45.4 15 54 28.5 28 26.5 23 16.5 7.5 54.4 50 18.5 68 35 35 32.8 28.5 20.2 22 80 42 40 39 33 24.2 30 104575551.54533 37 1306966645540 45 1548180766546.8 55 192 100 100 90 80 58 75 248 131 135 125 105 75.7 90 312 162 165 146 129 94 110 360 195 200 178 156 113 132 ? 233 240 215 187 135 ? 480 222 260 236 207 ? 160 ? 285 280 256 220 165 ? 600????? 200 ? 352 340 321 281 203 220 720 388 385 353 310 224 250 840 437 425 401 360 253 280 ?????? 315 ? 555 535 505 445 321 ?1080????? 355 ? 605 580 549 500 350 ?1200????? 400 ? 675 650 611 540 390 4501440????? 500 ? 855 820 780 680 494 560 ? 950 920 870 760 549 630 ? 1045 1020 965 850 605 710 ? 1200 1140 1075 960 694 800 ? ? 1320 1250 1100 790 900 ? ? 1470 1390 1220 880 sqcagemtr.eps
tesys? iec-style contactors and starters selection guide technical information: horsepower motor ratings 15 01/04 ? 2001-2004 schneider electric all rights reserved technical information: horsepower motor ratings the table below provides the average full-load currents of squirrel cage motors based on nec (national electrical code) tables 430-148, 149, and 150. these values are given only as a guide ? they may vary depending on the type of motor and manufacturer. refer to the actual motor nameplate for full-load current values. hp 110 to 120 vac 220 to 240 vac f 380 to 415 vac 440 to 480 vac 550 to 600 vac single phase two phase three phase single phase two phase three phase single phase three phase single phase two phase three phase single phase two phase three phase 1/10 3.0--1.5--1.0------- 1/8 3.8--1.9--1.2------- 1/6 4.4--2.2--1.4------- 1/4 5.8--2.9--1.8------- 1/3 7.2--3.6--2.3------- 1/2 9.8 4.0 4.4 4.9 2.0 2.2 3.2 1.3 2.5 1.0 1.1 2.0 0.8 0.9 3/4 13.8 4.8 6.4 6.9 2.4 3.2 4.5 1.8 3.5 1.2 1.6 2.8 1.0 1.3 1 16.0 6.4 8.4 8.0 3.2 4.2 5.1 2.3 4.0 1.6 2.1 3.2 1.3 1.7 11/2 20.0 9.0 12.0 10.0 4.5 6.0 6.4 3.3 5.0 2.3 3.0 4.0 1.8 2.4 2 24.0 11.8 13.6 12.0 5.9 6.8 7.7 4.3 6.0 3.0 3.4 4.8 2.4 2.7 3 34.0 16.6 19.2 17.0 8.3 9.6 10.9 6.1 8.5 4.2 4.8 6.8 3.3 3.9 5 56.0 26.4 30.4 28.0 13.2 15.2 17.9 9.7 14.0 6.6 7.6 11.2 5.3 6.1 7-1/2 80.0 38.0 44.0 40.0 19.0 22.0 27.0 14.0 21.0 9.0 11.0 16.0 8.0 9.0 10 100.048.056.050.024.028.033.018.026.012.014.020.010.011.0 15 135.072.084.068.036.042.044.027.034.018.021.027.014.017.0 20 -94.0108.088.047.054.056.034.044.023.027.035.019.022.0 25 - 118.0 136.0 110.0 59.0 68.0 70.0 44.0 55.0 29.0 34.0 44.0 24.0 27.0 30 - 138.0 160.0 136.0 69.0 80.0 87.0 51.0 68.0 35.0 40.0 54.0 28.0 32.0 40 - 180.0 208.0 176.0 90.0 104.0 112.0 66.0 88.0 45.0 52.0 70.0 36.0 41.0 50 - 226.0 260.0 216.0 113.0 130.0 139.0 83.0 108.0 56.0 65.0 86.0 45.0 52.0 60 ----133.0154.0-103.0-67.077.0-52.062.0 75 ----166.0192.0-128.0-83.096.0-66.077.0 100 ----218.0248.0-165.0-109.0124.0-87.099.0 125 -----312.0-208.0-135.0156.0-108.0125.0 150 -----360.0-240.0-156.0180.0-125.0144.0 200 -----480.0-320.0-208.0240.0-167.0192.0 250 -----602.0-403.0--302.0--242.0 300 -------482.0--361.0--289.0 350 -------560.0--414.0--336.0 400 -------636.0--477.0--382.0 500 -------786.0--590.0--472.0 f to obtain full-load currents for 200 and 208 vac motors, increase corresponding 220 to 240 vac ratings by 15 and 10 percent, re spectively. to obtain full-load currents for 265 and 277 vac motors, decrease corresponding 220 to 240 vac ratings by 13 and 17 percent, re spectively.
tesys? iec-style contactors and starters selection guide definitions of utilization categories ? 2001-2004 schneider electric all rights reserved 16 01/04 definitions of utilization categories iec contactors should be selected according to the utilization cate gory which is a combination of application and duty cycle rates defin ed by the following:  the type of application (inductive motor loads or resistive loads)  the conditions under which making or breaking current takes place (motor starting or running, reversing, plugging or jogging, locked rotor or stalled motor)  number of making and breaking operations (or cycles) required fo r the life of the contactor utilization categories for cont actors conforming to iec 60947-4 type of application utilization category definition ac applications category ac-1 this category applies to ac loads with a power factor greater than or equal to 0.95 (cos ? 0.95). application examples: heating, distribution. category ac-2 this category applies to starting, plugging, and inching of slip ring motors. on closing, the contactor makes the starting current, which is about 2.5 times the rated current of the motor. on opening, it must break the starting current at a voltage less than or equal to the mains supply voltage. category ac-3 this category applies to squirrel cage motors with breaking during normal running of the motor. on closing, the contactor makes the starting curren t, which is about 5 to 7 times the rated current of the motor. on opening, it breaks the rated current drawn by the motor; at this point, the voltage at the contactor terminals is about 20% of the mains supply voltage. breaking is light. applications examples: all standard squirrel cage motors ? lifts, escalators, conveyor belts, bucket elevators, compressors, pumps, mixers, air conditioning units, and so forth. categories ac-4 and ac-2 these categories cover applications with plugging and inching of squirrel cage and slip ring motors. the contactor closes at a current peak which may be as high as 5 or 7 times the rated motor current. on opening, it breaks this same current at a voltage which is higher as the motor speed lessens. this voltage can be the same as the mains voltage. breaking is severe. application examples: printing machines, wire drawing machines, cranes, hoists, metallurgy industry. dc applications category dc-1 this category applies to all types of dc load with a time constant (l/r) of less than or equal to 1 ms. category dc-3 this category applies to starting, counter-current braking, and inching of shunt motors. the time constant is less than or equal to 2 ms. on closing, the contactor makes the starting curren t, which is about 2.5 times the rated motor current. on opening, the contactor must be able to break 2.5 times the starting current at a voltage which is less than or equal to the mains voltage. the slower the motor speed, and therefore the lower its back e.m.f., the higher this voltage. breaking is difficult. category dc-5 this category applies to starting, counter-current braking and inching of series wound motors.the time constant is less than or equal to 7.5 ms. on closing, the contactor makes a starting current peak which may be as high as 2.5 times the rated motor current. on opening, the contactor breaks this same current at a voltage which is higher as the motor speed lessens. this voltage can be the same as the mains voltage. breaking is severe. utilization categories for auxi liary contacts and control re lays conforming to iec 60947-5 type of application utilization category definition ac applications category ac-14 this category applies to the switching of electromagnetic loads whose power drawn with the electromagnet closed is less than 72 va. application example: switching the operating coil of contactors and relays. category ac-15 this category applies to the switching of electromagnetic loads whose power drawn with the electromagnet closed is greater than 72 va. application example: switching the operating coil of contactors. dc applications category dc-13 this category applies to the switching of electromagnetic loads for which the time taken to reach 95% of the steady state current (t=0.95) is equal to 6 times the power p drawn by the load (with p 50 w). application example: switching the operating coil of contactors without economy resistor.
tesys? iec-style contactors and starters selection guide definitions of utilization categories 17 01/04 ? 2001-2004 schneider electric all rights reserved the following tables show the results of tests perf ormed according to standard utilization categories conforming to iec 60947 based on rated operational current (ie) and rated operational voltage (ve). contactors making and breaking conditions (normal operation) making and breaking conditions (occasional operation) ac supply typical applications utilization category making breaking making breaking i v cos ? ivcos ? i v cos ? i v cos ? resistors, non-inductive or slightly inductive loads ac-1 1 ie 1.05 ve 0.8 1 ie 1.05 ve 0.8 1.5 ie 1.05 ve 0.8 1.5 ie 1.05 ve 0.8 motors slip ring motors: starting, breaking ac-2 2 ie 1.05 ve 0.65 2 ie 1.05 ve 0.65 4 ie 1.05 ve 0.65 4 ie 1.05 ve 0.65 squirrel cage motors: starting, breaking while motor running ac-3 ie 100a 2 ie 1.05 ve 0.45 2 ie 1.05 ve 0.45 10 ie 1.05 ve 0.45 8 ie 1.05 ve 0.45 ie > 100a 2 ie 1.05 ve 0.35 2 ie 1.05 ve 0.35 10 ie 1.05 ve 0.35 8 ie 1.05 ve 0.35 slip ring motors: starting, plugging, inching ac-4 ie 100a 6 ie 1.05 ve 0.45 6 ie 1.05 ve 0.45 12 ie 1.05 ve 0.35 10 ie 1.05 ve 0.35 ie > 100a 6 ie 1.05 ve 0.35 6 ie 1.05 ve 0.35 12 ie 1.05 ve 0.35 10 ie 1.05 ve 0.35 dc supply typical applications utilization category making breaking making breaking iv l/r (ms) iv l/r (ms) iv l/r (ms) iv l/r (ms) resistors, non inductive or slightly inductive loads dc-1 1 ie 1 ve 1 1 ie 1 ve 1 1.5 ie 1.05 ve 1 1.5 ie 1.05 ve 1 shunt wound motors: starting, counter-current braking, inching dc-3 2.5 ie 1.05 ve 2 2.5 ie 1.05 ve 2 4 ie 1.05 ve 2.5 4 ie 1.05 ve 2.5 series wound motors: starting, counter-current braking, inching dc-5 2.5 ie 1.05 ve 7.5 2.5 ie 1.05 ve 7.5 4 ie 1.05 ve 15 4 ie 1.05 ve 15 auxiliary contacts and control relays making and breaking conditions (normal operation) making and breaking conditions (occasional operation) ac supply typical application utilization category making breaking making breaking i v cos ? ivcos ? i v cos ? i v cos ? electromagnets < 72 va ac-14 6 ie 1 ve 0.3 1 ie 1 ve 0.3 6 ie 1.1 ve 0.7 6 ie 1.1 ve 0.7 72 va ac-15 10 ie 1 ve 0.3 1 ie 1 ve 0.3 10 ie 1.1 ve 0.3 10 ie 1.1 ve 0.3 dc supply typical application utilization category making breaking making breaking iv l/r (ms) iv l/r (ms) iv l/r (ms) iv l/r (ms) electromagnets dc-13 1 ie 1 ve 6 p c 1 ie 1 ve 6 p c 1.1 ie 1.1 ve 6 p c 1 ie 1.1 ve 6 p c c the value 6 p (in watts) is based on practical observations and is considered to represent the majority of magnetic loads up to the maximum limit of p = 50 w, that is 6 p = 300 ms = l/r. above this, the loads are made up of smaller loads in parallel. the value 300 ms is therefore a maximum limit whatever the valu e of current drawn.
tesys? iec-style contactors and starters selection guide contactor selection for utilization category ac-3 ? 2001-2004 schneider electric all rights reserved 18 01/04 contactor selection for utilization category ac-3 how to use the electrical life curves the contactor electrical life curves on the following pages may be used to estimate the number of make and break operations a contactor can achieve for a s pecific application. compar e the application to the utilization category definitions listed on page 16 and select the appropriate ch art. each chart shows the number of operations in millions on the y axis and the current broken in amps on the x axis. ac-1 the current broken should be the same as the make and maintain current. ac-3 the current broken should be the same as the full load current rating (fla) of the motor. ac-4 the current broken should be the same as the locked rotor current (lra) or 6 times full-load current of the motor. once the appropriate chart is selected, find the breakin g current of the applicati on on the x axis of the chart and draw a vertical line. draw a vertical line at this point. find the intersection of this vertical line and the life curve of a particular contactor. at th e intersection point read the number of electrical operations off the y axis. if longer electrical life is required, continue checking the intersection points until an acceptable contactor is found. operational current and power conforming to iec ( 55c [131 f]) for category ac-3 contactor size lc1 lp1 lc1 lc1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lp1 k06 k09 k12 d09 d12 d18 d25 d32 d38 d40 max. operational current (ac-3) 440 vaca 6 912 9121825323840 rated operational power p (standard motor power ratings) 220/240 vac kw 1.5 2.2 3 2.2 3 4 5.5 7.5 9 11 380/400 vac kw 2.2 4 5.5 4 5.5 7.5 11 15 18.5 18.5 415 vac kw 2.2 4 5.5 4 5.5 9 11 15 18.5 22 440 vackw 3 4 5.54 5.59111518.522 500 vac kw 3 4 4 5.5 7.5 10 15 18.5 18.5 22 660/690 vac kw 3 4 4 5.5 7.5 10 15 18.5 18.5 30 1000 vackw?????????22 maximum operating rate in operating cycles/hour f on-load factor operational power lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lp1 d09 d12 d18 d25 d32 d38 d40 85% p ? ? ? 1200 1200 1200 1200 1000 1000 1000 0.5 p ? ? ? 3000 3000 2500 2500 2500 2500 2500 25% p ? ? ? 1800180018001800120012001200 operational current and power conforming to ul, csa ( 55c [131 f]) contactor size lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lp1 k06 k09 k12 d09 d12 d18 d25 d32 d38 k d40 max. operational current (ac-3) 440 vaca 6 9 129 12182532? 40 rated operational power p (standard motor power ratings) 60 hz 200/208 vachp1.5232357.510?10 230/240 vachp1.5332357.510?10 460/480 vac hp 3 5 7.5 5 7.5 10 15 20 ? 30 575/600 vac hp 3 5 10 7.5 10 15 20 30 ? 30 f depending on the operational power and the on-load factor ( 55 c [131 f]). k not ul listed or csa certified.
tesys? iec-style contactors and starters selection guide contactor selection for utilization category ac-3 19 01/04 ? 2001-2004 schneider electric all rights reserved in many applications there is a mixture of ac3 and ac 4 duty. for these applications the electrical life of a particular contactor can be estimated by using the following formula: where: e = estimated electrical life for mixed duty application ac3 = number of electrical operations taken from the 100% ac3 duty life curve ac4 = number of electrical operations taken for the 100% ac4 duty life curve p = proportion of ac-4 operations to total operati ons for the application, expressed as a percentage. example: a lc1d12 contactor for a motor load of 7.5 hp at 460 vac, 11 a, 15% ac4 duty. ac-3 breaking current is 11 amps from chart: ac3 = 2,250,000 operations ac-4 breaking current is 66 amps (approximate inrush) from chart: ac4 = 90,000 operations e = 2,250,000/[1 ? (15/100) + (15/100) x (2,250,000 / 90,000)] = 489,130 operat ions for approximate electrical life operational current and po wer conforming to iec ( 55c [131 f]) for category ac-3 contactor size lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 d50 d65 d80 d95 d115 d150 f185 f225 f265 f330 f400 f500 f630 f780 f800 max. operational current (ac-3) 440 vac a 50 65 80 95 115 150 185 225 265 330 400 500 630 780 800 rated operational power p (standard motor power ratings) 220/240 vac kw 15 18.5 22 25 30 40 55 63 75 100 110 147 200 220 250 380/400 vac kw 22 30 37 45 55 75 90 110 132 160 200 250 335 400 450 415 vac kw 25 37 45 45 59 80 100 110 140 180 220 280 375 425 450 440 vac kw 30 37 45 45 59 80 100 110 140 200 250 295 400 425 450 500 vac kw 30 37 55 55 75 90 110 129 160 200 257 355 400 450 450 660/690 vac kw 33 37 45 45 80 100 110 129 160 220 280 335 450 475 475 1000 vac kw 30 37 45 45 75 90 100 100 147 160 185 335 450 450 450 maximum operating rate in operating cycles/hour f on-load factor operational power lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 d50 d65 d80 d95 d115 d150 f185 f225 f265 f330 f400 f500 f630 f780 f800 85% p 1000 1000 750 750 750 750 750 750 750 750 500 500 500 500 500 0.5 p 2500 2500 2000 2000 2000 1200 2000 2000 2000 2000 1200 1200 1200 1200 600 25% p 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 600 600 operational current and power conforming to ul, csa ( 55c [131 f]) contactor size lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 d50 d65 d80 d95 k d115 d150 f185 f225 k f265 f330 f400 f500 f630 f780 f800 max. operational current (ac-3) 440 vac a 50 65 80 ? 115 150 185 ? 265 330 400 500 630 780 800 rated operational power p (standard motor power ratings) 60 hz 200/208 vac hp 15 20 30 ? 30 40 50 ? 60 75 100 150 ? ? 350 230/240 vac hp 15 20 30 ? 40 50 60 ? 75 100 125 200 300 450 400 460/480 vac hp 40 50 60 ? 75 100 125 ? 150 200 250 400 600 900 900 575/600 vac hp 40 50 60 ? 100 125 150 ? 200 250 300 500 800 900 900 f depending on the operational power and the on-load factor ( 55 c [131 f]). k not ul listed or csa certified. e ac 3 1 p 100 -------- - ?? ?? ? p 100 -------- - ac 3 ac 4 ---------- - ?? ?? + -------------------------------------------------------------- =
tesys? iec-style contactors and starters selection guide contactor selection for utilization category ac-3 ? 2001-2004 schneider electric all rights reserved 20 01/04 use in category ac-3 (ve 440 vac) note: the dotted lines relate to lc1d38 contactors only. operational power in kw-50 hz. example : asynchronous motor with p = 5.5 kw ? ve = 400 v ? ie = 11 a ? ic = ie = 11 a; or asynchronous motor with p = 5.5 kw ? ve = 415 v ? ie = 11 a ? ic = ie = 11 a. 3 million operating cycles required. the above selection curves show the contactor rating needed: lc1d18 or lp1d18. use in category ac-3 (ve = 660/690 vac) note: for ve = 1000 vac, use the 660/690 vac curves without exceeding the corresponding operational current at the operational power indicated for 1000 vac. control of 3-phase asynchronous squirrel cage motors with breaking while running. the current broken (ic) in category ac-3 is equal to the rated operational current (ie) of the motor. use motor full-load current on horizontal axis for selection purposes. 2 134 56 78 9 10 12 15 18 20 30 25 32 38 50 65 80 115 95 150 0.5 0.6 0.8 1 1.5 2 4 6 8 10 lc1d09 lc1, lp1k09 lc1, lp1k06 lc1d12 lc1, lp1k12 lc1d18 lc1d25 lc1d32, d38 lc1, lp1d40 lc1, lp1d50 lc1, lp1d65 lc1, lp1d80 lc1d95 lc1d115 lc1 d150 200 0.55 0.75 1.5 2.2 4 4 5.5 7.5 11 15 18.5 22 25 30 230 v 400 v 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 kw 1.5 2.2 5.5 7.5 11 15 18.5 22 37 45 55 75 30 440 v kw kw 45 55 75 millions of operating cycles current broken in a control of 3-phase asynchronous squirrel cage motors with breaking while running. the current broken (ic) in category ac-3 is equal to the rated operational current (ie) of the motor. use motor full-load current on horizontal axis for selection purposes. 0.6 0.8 1 1.5 2 3 4 6 8 10 lc1d09 lc1d12 lc1d18 lc1d25 lc1d25, d32 lc1, lp1d40 lc1, lp1d50 lc1, lp1d65 lc1, lp1d80 lc1d95 lc1d115 lc1d150 200 1 2 3 4 5 678 9 6.6 10 11 15 17 20 22 35 33 40 42 48 50 60 90 80 100 millions of operating cycles current broken in a
tesys? iec-style contactors and starters selection guide contactor selection for utilization category ac-3 21 01/04 ? 2001-2004 schneider electric all rights reserved use in category ac-3 (ve 440 vac) operational power in kw-50 hz. example : asynchronous motor with p = 132 kw ? ve = 380 v ? ie = 245 a ? ic = ie = 245 a; or asynchronous motor with p = 132 kw ? ve = 415 v ? ie = 240 a ? ic = ie = 240 a. 1.5 million operating cycles required. the above selection curves show the contactor rating needed: lc1f330. use in category ac-3 (ve = 660/690 vac) example : asynchronous motor with p = 132 kw ? ve = 660 v ? ie = 140 a ? ic = ie = 140 a. 1.5 million operating cycles required. the above selection curves show the contactor rating needed: lc1f330. control of 3-phase asynchronous squirrel cage motors with breaking while running. the current broken (ic) in category ac-3 is equal to the rated operational current (ie) of the motor. use motor full-load current on horizontal axis for selection purposes. 20 30 40 50 60 80 90 100 400 800 200 600 0.4 0.8 1 1.5 2 4 6 8 10 5.5 7.5 11 15 18.5 22 25 30 40 55 110 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250 335 400 11 15 18.5 22 30 37 45 55 75 90 132 200 285 45 75 200 220 147 220 v 230 v kw kw kw 380 v 400 v 440 v lc1 f185 lc1f225 lc1f265 lc1f330 lc1f400 lc1f500 lc1f780 lc1f630 lc1f800 0.6 millions of operating cycles control of 3-phase asynchronous squirrel cage motors with breaking while running. the current broken (ic) in category ac-3 is equal to the rated operational current (ie) of the motor. use motor full-load current on horizontal axis for selection purposes. 0.6 0.8 1 1.5 2 4 6 8 10 20 30 40 50 60 80 90 100 400 200 118 129 170 220 305 355 lc1f185 lc1f225 lc1f265 lc1f330 lc1f400 lc1f500 lc1f780 lc1 f800 lc1f630 0.4 kw 110 160 355 335 129 220 660 v 690 v millions of operating cycles
tesys? iec-style contactors and starters selection guide contactor selection for utilization category ac-1 ? 2001-2004 schneider electric all rights reserved 22 01/04 contactor selection for utilization category ac-1 use in category ac-1 (ve 440 vac) example : ve = 220 v ? ie = 50 a ( 40 c) ? ic = ie = 50 a. 2 million operating cycles required. the above selection curves show the contactor rating needed: lc1d50 or lp1d50. maximum operational curren t (open-mounted device) contactor size lc1 lc1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lp1 k09 k12 d09 d12 d18 d25 d32 d38 d40 maximum operating rate operating cycles/hour 600 600 600 600 600 600 600 600 600 cabling to iec 60947-1 cable c.s.a mm 2 (awg) 4 (#12) 4 (#12) 4 (#12) 4 (#12) 6 (#10) 6 (#10) 10 (#8) 10 (#8) 16 (#6) bar c.s.a. mm ????????? operational current in a, in ac-1 according to the ambient temperature to iec 60947-1 40 c (104 f) a 20 20 25 25 32 40 50 50 60 55 c (131 f) a 20 20 25 25 32 40 50 50 60 70 c (158 f) a (to vc) ff 17 17 22 28 35 35 42 maximum operational power 55c 220/230 vac kw 8 8 9 9 11 14 18 18 21 240 vac kw 8 8 9 9 12 15 19 19 23 380/400 vac kw 14 14 15 15 20 25 31 31 37 415 vac kw 14 14 17 17 21 27 34 34 41 440 vac kw 15 15 18 18 23 29 36 36 43 500 vac kw 17 17 20 20 23 33 41 41 49 660/690 vac kw 22 22 27 27 34 43 54 54 65 1000 vac kw ????????70 f please consult our local representatives or agents. increase in operati on current by paralleling of poles: apply the following multiplying factors to the current or power values given above. the factors take into account the often unbalanced current distribution between poles: 2 poles in parallel: k = 1.6 3 poles in parallel: k = 2.25 4 poles in parallel: k = 2.8 control of resistive circuits (power factor 0.95). the current broken (ic) in category ac-1 is equal to the current (ie) normally drawn by the load. use motor full-load current on horizontal axis for selection purposes. 1 2 3 4 6 8 10 20 25 32 100 125 200 250 400 40 50 60 80 8 10 6 4 2 1.5 1 0.8 0.6 0.4 0.2 0.1 lc1, lp1k09 lc1, lp1k12 lc1, lp1d09 lc1, lp1d12 lc1, lp1d18 lc1, lp1d25 lc1, lp1d32, lc1d38 lc1, lp1d40 lc1, lp1d50 lc1, lp1d65 lc1, lp1d80 lc1d95 lc1d115 lc1d150 millions of operating cycles current broken in a
tesys? iec-style contactors and starters selection guide contactor selection for utilization category ac-1 23 01/04 ? 2001-2004 schneider electric all rights reserved note: the dotted lines relate to lc1f225 contactors only. example : ve = 220 v ? ie = 500 a ( 40 c) ? ic = ie = 500 a. 2 million operating cycles required. the above selection curves show the contactor rating needed: lc1 f780. maximum operational curren t (open-mounted device) contactor size lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 d50 d65 d80 d95 d11 5 d15 0 f185 f225 f265 f330 f400 f500 f630 f780 f800 maximum operating rate operating cycles/hour 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 cabling to iec 60947-1 cable c.s.a mm 2 (awg) 25 (#4) 25 (#4) 50 (#0) 50 (#0) 120 (250 mcm) 120 (250 mcm) 150 (300 mcm) 185 (350 mcm) 185 (350 mcm) 240 (500 mcm) ???? ? number of bars ??????????2 2 2 2 2 bar c.s.a. mm ??????????30 x 540 x 560 x 5100 x 560 x 5 inches??????????1.18 x 0.21.57 x 0.22.36 x 0.24.0 x 0.22.36 x 0.2 operational current in a, in ac-1 according to the ambient temperature to iec 60947-1 40 c (104 f) a 80 80 125 125 250 250 275 315 350 400 500 700 1000 1600 1000 55 c (131 f) a 80 80 125 125 200 200 275 280 300 360 430 580 850 1350 850 70 c (158 f) a (to vc) 56 56 80 80 160 160 180 200 250 290 340 500 700 1100 700 maximum operational power 55c (131f) 220/230 vac kw 29 29 45 45 80 80 90 100 120 145 170 240 350 550 350 240 vac kw 31 31 49 49 83 83 95 110 125 160 180 255 370 570 370 380/400 vac kw 50 50 78 78 135 135 165 175 210 250 300 430 600 950 600 415 vac kw 54 54 85 85 140 140 170 185 220 260 310 445 630 1000 630 440 vac kw 58 58 90 90 150 150 180 200 230 290 330 470 670 1050 670 500 vac kw 65 65 102 102 170 170 200 220 270 320 380 660 750 1200 750 660/690 vac kw 86 86 135 135 235 235 280 300 370 400 530 740 1000 1650 1000 1000 vac kw 85 100 120 120 345 345 410 450 540 640 760 950 1500 2400 1500 increase in operati on current by paralleling of poles: apply the following multiplying factors to th e current or power values given above. the factors take into account the often unbalanced current distribution between poles: 2 poles in parallel: k = 1.6 3 poles in parallel: k = 2.254 poles in parallel:k = 2.8 use in category ac-1 (ve 440 vac) control of resistive circuits (power factor 0.95). the current broken (ic) in category ac-1 is equal to the current (ie) normally drawn by the load. use motor full-load current on horizontal axis for selection purposes. 8 10 6 4 2 1 0.8 0.6 0.4 0.2 0.1 millions of operating cycles 20 40 50 60 80 100 200 250 275 500 600 700 800 1000 1600 300 315 350 400 current broken in a lc1f185, f225 lc1f265 lc1f330 lc1f400 lc1f500 lc1f630 lc1f800 lc1f780
tesys? iec-style contactors and starters selection guide contactor selection for utilization categories ac-2 and ac-4 ? 2001-2004 schneider electric all rights reserved 24 01/04 contactor selection for utilization categories ac-2 and ac-4 utilization category ac-2 is for breaking the starting current of slip-ring motors, while utilization category ac-4 is for breaking the starting current of squirrel-cage motors. plugging the current varies from the maximum plug-braki ng current to the rated motor current. the making current must be compatible with the rated making and breaking capacities of th e contactor. as breaking normally takes place at a current value at or near the locked rotor current, the contactor can be selected using the criteria for categories ac-2 and ac-4. note: tables continue on next page. maximum breaking current for categories ac-2 and ac-4 contactor size lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lp1 k06 k09 k12 d09 d12 d18 d25 d32 d38 d40 in category ac-4 (ie maximum) ? ve 440 vac ie maximum broken = 6 x i motor a 36 54 54 54 72 108 150 192 192 240 ? 440 vac ve 690 vac ie maximum broken = 6 x i motor a 26 40 40 40 50 70 90 105 105 150 depending on the maximum operating rate f and the on-load factor, 55 c [131 f] c from 150 & 15% to 300 & 10% a 20 30 30 30 40 45 75 80 80 110 from 150 & 20% to 600 & 10% a 18 27 27 27 36 40 67 70 70 96 from 150 & 30% to 1200 & 10% a 16 24 24 24 30 35 56 60 60 80 from 150 & 55% to 2400 & 10% a 13 19 19 19 24 30 45 50 50 62 from 150 & 85% to 3600 & 10% a 10 16 16 16 21 25 40 45 45 53 f do not exceed the maximum number of mechanical operating cycles. c for temperatures higher than 55 c (131 f), use a maximum operating rate value equal to 80% of the actual value when selecting from the above tables. permissible ac-4 power rating for 200,000 operating cycles operational voltage lc  lp  lc  lp  lc  lp  lc  lp  lc  lp  lc  lp  lc  lp  lc  lp  lc  lc  lp  k06 k09 k12 d09 d12 d18 d25 d32 d38 d40 220/230 vac kw 0.75 1.1 1.1 1.5 1.5 2.2 3 4 4 4 380/400 vac kw 1.52.22.22.23.74 5.57.57.59 415 vac kw 1.52.22.22.23 3.75.57.57.59 440 vac kw 1.52.22.22.23 3.75.57.57.511 500 vac kw 2.233345.57.59911 660/690 vac kw 3 4 4 4 5.5 7.5 10 11 11 15
tesys? iec-style contactors and starters selection guide contactor selection for utilization categories ac-2 and ac-4 25 01/04 ? 2001-2004 schneider electric all rights reserved maximum breaking current for categories ac-2 and ac-4 contactor size lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 d50 d65 d80 d95 d115 d150 f185 f225 f265 f330 f400 f500 f630 f780 f800 in category ac-4 (ie maximum) ? ve 440 vac ie maximum broken = 6 x i motor a 300 390 480 570 630 830 1020 1230 1470 1800 2220 2760 3360 4260 3690 ? 440 vac ve 690 vac ie maximum broken = 6 x i motor a 170 210 250 250 540 640 708 810 1020 1410 1830 2130 2760 2910 2910 depending on the maximum operating rate f and the on-load factor, 55 c [131 f] c from 150 & 15% to 300 & 10% a 140 160 200 200 280 310 380 420 560 670 780 1100 1400 1600 1600 from 150 & 20% to 600 & 10% a 120 148 170 170 250 280 350 400 500 600 700 950 1250 1400 1400 from 150 & 30% to 1200 & 10% a 100 132 145 145 215 240 300 330 400 500 600 750 950 1100 1100 from 150 & 55% to 2400 & 10% a 80 110 120 120 170 150 240 270 320 390 450 600 720 820 820 from 150 & 85% to 3600 & 10% a 70 90 100 100 125 145 170 190 230 290 350 500 660 710 710 f do not exceed the maximum number of mechanical operating cycles. c for temperatures higher than 55 c (131 f), use a maximum operating rate value equal to 80% of the actual value when selecting from the above tables. plugging the current varies from the maximum plug-braking current to th e rated motor current. the making current must be compatible with the rated making and breaking capacitie s of the contactor. as breaking normally ta kes place at a current value at or near the locked rotor current, the contactor can be selected using the criteria for categories ac-2 and ac-4. permissible ac-4 power rating for 200,000 operating cycles operational voltage lc  lp  lc  lp  lc  lp  lc  lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 d50 d65 d80 d95 d115 d150 f185 f225 f265 f330 f400 f500 f630 f780 f800 220/230 vac kw 5.57.57.59 9 11222530374045556363 380/400 vac kw 1111151518.522404555637580100110110 415 vac kw 1111151518.522455159758090100110110 440 vac kw 11 15 15 15 18.5 22 45 51 63 75 80 100 110 132 132 500 vac kw 15 18.5 22 22 37 30 51 59 75 80 90 110 132 150 150 660/690 vac kw 18.5 22 25 25 30 45 63 75 90 110 129 140 160 185 185
tesys? iec-style contactors and starters selection guide contactor selection for utilization categories ac-2 and ac-4 ? 2001-2004 schneider electric all rights reserved 26 01/04 use in categories ac-2 or ac-4 (ve 440 vac) note: the dotted lines relate to lc1k12 and lp1k12 contactors only. example : asynchronous motor with p = 5.5 kw ? ve = 400 v ? ie = 11 a lc = 6 x le = 66 a; or asynchronous motor with p = 5.5 kw ? ve = 415 v ? ie = 11 a lc = 6 x le = 66 a. 200,000 operating cycles required. the above selection curves show the contactor rating needed: lc1d25 or lp1d25. use in category ac-4 (440 vac < ve 690 v) control of 3-phase asynchronous squirrel cage (ac-4) or slip- ring (ac-2) motors with breaking while motor stalled. the current broken (ic) in category ac-4 is equal to 6 times ie, where le is the operational current of the motor. use motor-locked rotor current (6 times full-load current) on horizontal axis for selection purposes. 5678910 20 3036405054 80 72 108 150 192 240 300 390 480 630 828 1000 570 0.01 0.02 0.03 0.04 0.06 0.05 0.08 0.1 0.2 0.4 0.6 0.8 1 lc1, lp1d09 lc1, lp1d12 lc1, lp1d18 lc1, lp1d25 lc1, lp1d32, lc1d38 lc1, lp1d40 lc1, lp1d50 lc1, lp1d65 lc1, lp1d80 lc1d95 lc1d115 lc1 d150 lc1, lp1k09,k12 lc1, lp1k06 millions of operating cycles current broken in a control of 3-phase asynchronous squirrel cage motors with breaking while motor stalled. the current broken (ic) in category ac-4 is equal to 6 times ie, where le is the operational current of the motor. use motor-locked rotor current (6 times full-load current) on horizontal axis for selection purposes. 56 7 8 9 10 20 30 40 50 90 70 105 150 170 210 250 300 400 500 640 800 1000 540 0.01 0.02 0.03 0.04 0.06 0.05 0.08 0.1 0.2 0.4 0.6 0.8 1 lc1, lp1d09 lc1, lp1d12 lc1, lp1d18 lc1, lp1d25 lc1, lp1d32, lc1d38 lc1, lp1d40 lc1, lp1d50 lc1, lp1d65 lc1, lp1d80 lc1d95 lc1d115 lc1 d150 millions of operating cycles current broken in a
tesys? iec-style contactors and starters selection guide contactor selection for utilization categories ac-2 and ac-4 27 01/04 ? 2001-2004 schneider electric all rights reserved use in categories ac-2 or ac-4 (ve 440 vac) example : asynchronous motor with p = 90 kw ? ve = 380 v ? ie = 170 a lc = 6 x le = 1020 a; or asynchronous motor with p = 90 kw ? ve = 415 v ? ie = 165 a lc = 6 x le = 990 a. 60,000 operati ng cycles required. the above selection curves show the contactor rating needed: lc1f265. use in category ac-4 (440 vac < ve 690 v) control of 3-phase asynchronous squirrel cage (ac-4) or slip- ring (ac-2) motors with breaking while motor stalled. the current broken (ic) in category ac-4 is equal to 6 times ie, where le is the operational current of the motor. use motor-locked rotor current (6 times full-load current) on horizontal axis for selection purposes. 100 200 400 600 800 1000 2000 3800 5000 1 0.8 0.6 0.4 0.2 0.1 0.08 0.06 0.04 0.02 0.01 lc1-f185 lc1-f225 lc1-f265 lc1-f330 lc1-f400 lc1-f500 lc1-f630 lc1-f800 lc1-f780 current broken in a millions of operating cycles control of 3-phase asynchronous squirrel cage motors with breaking while motor stalled. the current broken (ic) in category ac-4 is equal to 6 times ie, where le is the operational current of the motor. use motor-locked rotor current (6 times full-load current) on horizontal axis for selection purposes. 100 200 400 600 800 1000 2000 4000 1 0.8 0.6 0.4 0.2 0.1 0.08 0.06 0.04 0.02 0.01 lc1-f185 lc1-f225 lc1-f265 lc1-f330 lc1-f400 lc1-f500 lc1-f630 lc1-f780, f800 current broken in a millions of operating cycles
tesys? iec-style contactors and starters selection guide contactor selection for utilization categories dc-1 to dc-5 ? 2001-2004 schneider electric all rights reserved 28 01/04 contactor selection for utilization categories dc-1 to dc-5 continued on next page. rated operational current (ie) in amperes for category dc-1 resistive loads: time constant 1 ms, ambient 55 c [131 f] rated operational voltag e ve number of poles connected in series contactor rating f lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 d09 d12 d18 d25 d32 d38 d40 d50 d65 d80 24 vdc 1 15151530303040505070 2 181818323232557070100 3 202020323232557070100 4 ? 20 ? 32 ? ? 55 ? 70 100 48/75 vdc 1 12121225252525252525 2 171717303030557070100 3 202020323232557070100 4 ? 20 ? 32 ? ? 55 ? 70 100 125 vdc 1 6688888888 2 12121225252540506080 3 15151527272745606585 4 ? 17 ? 30 ? ? 55 ? 70 100 225 vdc 1 4455555555 2 8 8 8 15 15 15 35 40 40 45 3 10101022222240505055 4 ? 12 ? 25 ? ? 50 ? 60 70 300 vdc 3 ?????????? 4 ? 12 ? 25 ? 40 40 ? 60 70 460 vdc 4 ?????????? 900 vdc 2 ?????????? 1200 vdc 3 ?????????? 1500 vdc 4 ?????????? rated operational current (ie) in amperes for categories dc-2 to dc-5 inductive loads: time constant 15 ms, ambient 55 c [131 f] rated operational voltag e ve number of poles connected in series contactor rating f lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lc1 lp1 lc1 lp1 lc1 lp1 lc1 lp1 d09 d12 d18 d25 d32 d38 d40 d50 d65 d80 24 vdc 1 12121220202025353540 2 15151525252530454560 3 18181830303045555580 4 ? 18 ? 30 ? ? 50 ? 60 90 48/75 vdc 1 10101015151515151515 2 12121220202025404050 3 15151530303040505070 4 ? 15 ? 30 ? ? 50 ? 60 90 125 vdc 1 2 2 2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2 8 8 8 15 15 15 20 25 25 40 3 12121220202030353560 4 ? 15 ? 25 ? ? 40 ? 50 72 225 vdc 1 0.75 0.75 0.75 1 1 1 1 1 1 1 2 1.5 1.5 1.5 3 3 3 4 5 5 7 3 6 6 6 10 10 10 20 25 25 35 4 ? 8 ? 15 ? ? 25 ? 30 40 300 vdc 3 ?????????? 4 ? 6 ? 10 ? ? 20 ? 25 35 460 vdc 1 ?????????? 4 ?????????? 900 vdc 2 ?????????? 1200 vdc 3 ?????????? 1500 vdc 4 ?????????? f for rated operational currents of contactors lc1 and lp1k , please consult your local square d field sales office. ? + ? + l r ? + ? + l r
tesys? iec-style contactors and starters selection guide contactor selection for utilization categories dc-1 to dc-5 29 01/04 ? 2001-2004 schneider electric all rights reserved rated operational current (ie) in amperes for category dc-1 resistive loads: time constant 1 ms, ambient 55 c [131 f] rated operational voltag e ve number of poles connected in series lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 d95 d115 d150 f185 f225 f265 f330 f400 f500 f630 f780 f800 24 vdc 1 70 200 200 240 260 300 360 430 580 850 1300 850 2 100 200 200 240 260 300 360 430 580 850 1300 850 3 100 200 200 240 260 300 360 430 580 850 1300 850 4 ? 200 ? 240 260 300 360 430 580 850 1300 850 48/75 vdc 1 25 200 200 240 260 300 360 430 580 850 1300 850 2 100 200 200 240 260 300 360 430 580 850 1300 850 3 100 200 200 240 260 300 360 430 580 850 1300 850 4 ? 200 ? 240 260 300 360 430 580 850 1300 850 125 vdc 1 8 180 180 210 230 270 320 380 520 760 1180 760 2 80 180 180 210 230 270 320 380 520 760 1180 760 3 85 200 200 240 260 300 360 430 580 850 1300 850 4 ? 200 ? 240 260 300 360 430 580 850 1300 850 225 vdc 1 5160160????????? 2 45 160 160 190 200 250 280 350 450 700 1000 700 3 55 200 200 240 260 300 360 430 580 850 1300 850 4 ? 200 ? 240 260 300 360 430 580 850 1300 850 300 vdc 3 ? 140 140 190 200 250 280 350 450 700 1000 700 4 ? 180 ? 240 260 300 360 430 580 850 1000 850 460 vdc 4 ? 140 ? 190 200 250 280 350 450 700 1000 700 900 vdc 2 ???????????? 1200 vdc 3 ???????????? 1500 vdc 4 ???????????? rated operational current (ie) in amperes for categories dc-2 to dc-5 inductive loads: time constant 15 ms, ambient 55 c [131 f] rated operational voltage ve number of poles connected in series contactor rating f lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 lc1 d95 d115 d150 f185 f225 f265 f330 f400 f500 f630 f780 f800 24 vdc 1 40 200 200 240 260 300 360 430 580 850 1300 850 2 60 200 200 240 260 300 360 430 580 850 1300 850 3 80 200 200 240 260 300 360 430 580 850 1300 850 4 ? 200 ? 240 260 300 360 430 580 850 1300 850 48/75 vdc 1 15 200 200 240 260 300 360 430 580 850 1300 850 2 50 200 200 240 260 300 360 430 580 850 1300 850 3 70 200 200 240 260 300 360 430 580 850 1300 850 4 ? 200 ? 240 260 300 360 430 580 850 1300 850 125 vdc 1 2.5100100????????? 2 40 140 140 160 180 250 300 350 500 700 1000 700 3 60 200 220 240 240 280 310 350 550 850 1000 850 4 ? 200 ? 240 240 280 310 350 550 850 1000 850 225 vdc 1 1100100????????? 2 7 120 120 140 160 220 280 310 480 680 900 680 3 35 140 140 160 180 250 300 350 500 700 1000 700 4 ? 180 ? 240 260 300 360 430 580 850 1300 850 300 vdc 3 ? 100 100 140 160 220 280 310 480 680 900 680 4 ? 180 ? 240 260 300 360 430 580 850 1300 850 460 vdc 1 ???????????? 4 ? 100 100 140 160 220 280 310 480 680 800 680 900 vdc 2 ???????????? 1200 vdc 3 ???????????? 1500 vdc 4 ???????????? f for rated operational currents of contactors lc1 and lp1k , please consult your local square d field sales office. l r l r
tesys? iec-style contactors and starters selection guide contactor selection for utilization categories dc-1 to dc-5 ? 2001-2004 schneider electric all rights reserved 30 01/04 use in category dc-1 to dc-5 the criteria for contactor selection are:  the rated operational current ie.  the rated operational voltage ve (see page 31).  the utilization category and the time constant l/r (see page 31)  the required electrical durability. maximum operating rate (operating cycles) the following operating rate must not be exceeded: 120 operating cycles/hour at rated operational current ie. electrical durability example : series-wound motor with p = 1.5 kw, ve = 200 v, and ie = 7.5 a. application: counter-current braking a nd inching (utilization category dc-5). select a contactor type lc1d25 or lp1d25 with 3 poles in series. the power broken is: pc total = 2.5 x 200 x 7.5 = 3.75 kw. the power broken per pole is: 1.25 kw. the electrical durability read from the curve above is 106 operating cycles. use of poles in parallel electrical durability can be increased by using poles connected in parallel. with n poles connected in parallel, the electrical durability becomes: electrical durability read from the curves x n x 0.7. note: connecting the poles in parallel does not allow the maximum operational currents indicated on pages 28 and 29 to be exceeded. note: ensure that the connections are made in such a way as to equalize the currents in each pole. 0.01 0.02 0.04 0.06 0.08 1 2 4 6 8 10 0.1 0.2 0.4 0.6 0.8 0.2 0.3 0.4 0.5 0.6 0.7 1 0.8 0.9 2 34 5 67 9 8 10 16 14 20 30 24 32 36 40 50 60 70 90 80 100 lc1/ lp1d09 lc1/lp1d12 lc1/ lp1d18 lc1/ lp1d25 lc1/ lp1d32. lc1d38 lc1/ lp1d40 lc1/ lp1d50 lc1/ lp1d65 lc1/ lp1d80 lc1d95 lc1d115 /d15 0 millions of operating cycles power broken per pole in kw
tesys? iec-style contactors and starters selection guide contactor selection for utilization categories dc-1 to dc-5 31 01/04 ? 2001-2004 schneider electric all rights reserved telemecanique offers a line of contactors for applic ations involving dc control circuits. it does not matter whether the power circuit is ac or dc. there are two considerations when us ing these contactors in applications involving a dc power circuit: 1. voltage per pole must not be exceeded. on d-line contactors, you can use the ac inductive/ resistive rating as long as the voltage does not exceed 75 volts per pole. on f-line contactors, th e voltage must not exceed 125 volts per pole. however, by wiring the contacts in series , you can multiply the number of poles in series by the maximum voltage allowed per pole. example 1: d-line contactors (9 - 38 amps ) example 2: f-line & d115, d150 contactors 2. l/r 15 ms without derating. a time constant is defined as the length of time it takes the current to rise from 0 to 63.2% of its maximum value, or to decay to 36.8% of its maximum value. time constants are measured in seconds. the inductance (l) is measured in henri es and the resistance (r) is measured in ohms. in a pure resistive circui t, current reaches its maximum value w hen the circuit is energized. because inductance opposes a change in current flow and tends to hold back current, the time constant will increase as the circuit inductance is increased. as the time constant exceeds 15 ms, the electrical life of the contactor is affected and a derating fa ctor (normally one contactor size) is needed to compensate for this loss. in most applications this time constant will be under 15 ms. it is a good idea, however, to check with the motor manufacturer. 75 volts 150 volts 225 volts 300 volts dcontex.eps 125 volts 250 volts 375 volts 500 volts fcontex.eps on ac power circuits, follow regular procedures.
tesys? iec-style contactors and starters selection guide voltage code tables ? 2001-2004 schneider electric all rights reserved 32 01/04 voltage code table voltage code tables _ see not es pertaining to each product lin e at the end of this table. k-line d-line f-line voltage frequency lc1k lc2k notes k1, k2 lc7k lc8k note k4 lp1k lp2k notes k2, k3 lp4k lp5k lc1d09 - d38 lc2d09 - d38 notes d1, d3 lc1d40 - d95 lc2d40 - d95 note d1 lc1d115 - d150 note d1, d2, d4 lc1f115 - f225 note f1, f2 lc1f265 - f400 note f1, f2 lc1f500 - f630 note f1, f2 lc1f780 note f1, f2 lc1f800 note f1, f2, f3, 5low consump dc ----al - ------ 12 50/60 j7---j7 - ------ 50----- j5------ dc--jd-jd jd------ low consump dc ---jw3jl - ------ wide range dc ----- jw------ 20 50/60z7---- z7------ 50----- z5------ 60----- z6------ dc--zd-- - ------ low consump dc ---zw3zl - ------ 24 50/60 b7 note k2 b7 - - b7 b7 b7 - - - - - 50 - - - - - b5 b5 b5 - - - - 60 - - - - - b6 b6 b6 - - - - 40-400 - - - - - - - - b7 note f4 --- dc - - bd note k2 -bd bd bd bd bd note f4 --- low consump dc ---bw3bl - ------ wide range dc ----- bw------ 36 50/60c7---cc7 - ------ dc - - cd - cd cd cd - - - - - wide range dc ----- cw------ 42 50/60 d7 d7 - - d7 d7 d7 - - - - - 50 - - - - - d5 d5 d5 - - - - 60----- - ------ 48 50/60 e7 e7 - - e7 e7 e7 - - - - - 50 - - - - - e5 e5 e5 - - - - 60 - - - - - e6 e6 e6 - - - - 40-400 - - - - - - - e7 e7 e7 - - dc - -ed-ed ed edededed - - low consump dc ---ew3el - ------ wide range dc ----- ew------ 60 50/60----ee7 - ------ dc - - nd - nd nd nd - - - - - 72 dc - - sd - sd sd sd - - - - - low consump dc ---sw3sl - ------ wide range dc ----- sw------ 96 low consump dc ----dl - ------
tesys? iec-style contactors and starters selection guide voltage code tables 33 08/04 ? 2001-2004 schneider electric all rights reserved voltage frequency lc1k lc2k notes k1, k2 lc7k lc8k note k4 lp1k lp2k note k2, k3 lp4k lp5k lc1d09 - d38 lc2d09 - d38 notes d1, d3 lc1d40 - d95 lc2d40 - d95 note d1 lc1d115 - d150 note d1, d2, d4 lc1f115 - f225 note f1, f2 lc1f265 - f400 note f1, f2 lc1f500 - f630 note f1, f2 lc1f780 note f1, f2 lc1f800 note f1, f2, f3, 100 50/60----k7k7------ dc--kd-- - ------ 110 50/60f7f7--f7 f7f7----- 50----- f5f5f5- - -- 60----- f6f6f6- - -- 40-400 - - - - - - - f7 f7 f7 f7 - dc --fd-fd fd fdfdfdfdfdfw low consump dc ---fw3fl - ------ wide range dc ----- fw------ 110/12740-400----- - -----fe7 115 50/60fe7fe7--fe7fe7fe7----- 50 - - - - - fe5 fe5 fe5 - - - - 40-400 - - - - - - - fe7 fe7 fe7 fe7 - 120 50/60g7g7--g7g7g7----- 50----- - ------ 60----- g6g6g6---- 40-400 - - - - - - - g7 g7 note f5 f7 f7 - dc----- - -----fw low consump dc ---gw3- - ------ 125 dc - - gd - gd gd gd gd gd gd gd - 127 50/60fc7---fc7 -fc7----- 60----- g5fc5g5---- 40-400---- - - - g7g7g7g7- 155dc--pd-- - ------ 174dc--qd-- - ------ 200 50/60----l7 l7------ dc--ld-- - ------ 200/208 50/60l7---- - ------ 60----- - -l6---- 40-400 - - - - - - - - l7 l7 l7 - 208 50/60----le7le7le7----- 60----- l6l6----- 40-400 - - - - - - - l7 - - - - 220 50/60-m7--m7m7m7----- 50 - - - - - - m5 m5 - - - - 60----- m6m6m6---- 40-400 - - - - - - - m7 m7 m7 m7 - dc - - md - md md md - md md md - low consump dc ----ml - ------ wide range dc ----- mw------ 220/230 50/60m7---- - ------ 50----- m5------ 60----- - ------ 40-400----- - ------ dc----- - -md---- 220/240 40-400----- - -----p7 dc----- - -----mw voltage code tables (continued) _ see notes pertaining to each product line at the end of this table. k-line d-line f-line
tesys? iec-style contactors and starters selection guide voltage code tables ? 2001-2004 schneider electric all rights reserved 34 08/04 voltage frequency lc1k lc2k notes k1, k2 lc7k lc8k note k4 lp1k lp2k note k2, k3 lp4k lp5k lc1d09 - d38 lc2d09 - d38 notes d1, d3 lc1d40 - d95 lc2d40 - d95 note d1 lc1d115 - d150 note d1, d2, d4 lc1f115 - f225 note f1, f2 lc1f265 - f400 note f1, f2 lc1f500 - f630 note f1, f2 lc1f780 note f1, f2 lc1f800 note f1, f2, f3, 230 50/60 p7 - - - p7 p7 p7 - - - - - 50 - - - - u7 p5 p5 p5 - - - - 60----- - ------ 40-400---- - - - p7p7p7p7- dc--mpd-- - ------ 230/240 50/60 u7 note k4 u7--- - ------ 240 50/60 - - - - u7 u7 u7 - - - - - 50 - - - - - u5 u5 u5 - - - - 60 - - - - - u6 u6 u6 - - - - 40-400 - - - - - - - u7 u7 u7 u7 - dc--mud-- - ------ 250 dc - - ud - ud ud ud ud ud ud ud - low consump dc ----ul - ------ 256 50/60w7---- - ------ 50----- w5------ 277 50/60 ue7 - - - w7 - ue7 - - - - - 50 - - - - - w6 w6 w5 - - - - 40-400 - - - - - - - - w7 w7 w7 - 380 50/60 - - - - q7 q7 q7 - - - - - 50 - - - - - - q5 q5 - - - - 60 - - - - - q6 q6 q6 - - - - 40-400- --- - - - q7q7q7q7- 380/400 50/60 q7 note k4 ---- - ------ 50----- q5------ 60----- - ------ 40-400----- - ------ dc----- - -----qw 380/440 40-400 - - - - - - - - - - - v7 400 50/60 v7 - - - v7 v7 v7 - - - - - 50 - - - - - v5 v5 v5 - - - - 40-400---- - - - v7v7v7v7- 400/415 50/60 n7 - - - - - - - - - - - 415 50/60 - - - - n7 n7 n7 - - - - - 50 - - - - - n5 n5 n5 - - - - 40-400 - - - - - - - n7 n7 n7 n7 - 415-440 50----- - ------ 40-400----- - ------ 440 50/60 r7 - - - r7 r7 r7 - - - - - 50 - - - - - r5 r5 - - - - - 60 - - - - - r6 r6 r6 - - - - 40-400 - - - - - - - r7 r7 r7 r7 - dc - - - - rd rd rd - rd rd rd - 440/460 dc - - - - - - - rd - - - - 460/480 60 - - - - - - - q5 - - - - 480 50/60t7---t7 -t7----- 50----- - ------ 60 - - - - - t6 t6 - - - n7 - 40-400 - - - - - - - - s7 note f4 --- voltage code tables (continued) _ se e notes pertaining to each produc t line at the end of this table. k-line d-line f-line
tesys? iec-style contactors and starters selection guide voltage code tables 35 01/04 ? 2001-2004 schneider electric all rights reserved voltage frequency lc1k lc2k notes k1, k2 lc7k lc8k note k4 lp1k lp2k note k2, k3 lp4k lp5k lc1d09 - d38 lc2d09 - d38 notes d1, d3 lc1d40 - d95 lc2d40 - d95 note d1 lc1d115 - d150 note d1, d2, d4 lc1f115 - f225 note f1, f2 lc1f265 - f400 note f1, f2 lc1f500 - f630 note f1, f2 lc1f780 note f1, f2 lc1f800 note f1, f2, f3, 500 50/60s7---s7 -s7----- 50----- s5s5s5---- 40-400---- - - - s7s7s7s7- 575 50/60sc7---sc7 - ------ 60----- s6------ 600 50/60x7---x7 - ------ 60----- x6------ 40-400 - - - - - - - - - x7 - - 660 50----y5y5------ 60----- - -y6---- 660/69050/60y7---- - ------ notes: k-line: k1 up to and including 240 v, coil with integral suppression device (bi-directional diode): add 2 to the requested voltage c ode. ex. j72 k2 for voltage codes b7 or bd, when connecting an electronic sensor or timer in series with the coil of the control relay, se lect a 20 v coil (voltage code z7 for ac or zd for dc). this coil compensates for incurred voltage drop. k3 coil with integral suppression device available (bidirectional diode): add 3 to the requested voltage code. ex jd3. k4 for voltage codes m7, u7, q7, n7, y7 and all lc7k and lc8k devices, operating range is 0.85 - 1.10 of nominal. for all oth er lc1k and lc2k the operating range is 0.80 - 1.15 of nominal. d line: d1 for operating ranges refer to technical data section of the d-line contactors. ranges vary as a function of the current ra ting of the contactor and type of supply (ac/dc) d2 lc1-d150 contactors utilize dual frequency 50/60 hz. coils only. single frequency coils are not available. d3 lc1d09 -lc1d38 contactors with dc coil have integral suppression device (bi-directional diode) as standard. d4 d115 and d150 coils have integral suppression device fitted as standard. f-line: f1 for operating ranges refer to technical data section of the f-line contactors. ranges vary as a function of the supply (ac /dc). f2 for non-stock voltage codes, order contactor and coil separately. see page 202 - 209 for coils. f3 built in surge suppressor included on lc1f800 coils. f4 for use with lc1f265 and lc1f330 only. f5 for lc1-f400 contactor with 120vac coil, use f7 code. voltage code tables (continued) _ see notes pertaining to each product line at the end of this table. k-line d-line f-line
tesys? iec-style contactors and starters selection guide definitions and comments ? 2001-2004 schneider electric all rights reserved 36 01/04 definitions and comments altitude the low oxygen atmosphere at high altitudes reduces the di electric strength of the air and hence the rated operational voltage of the contactor. it also reduces the cooling effect of the air and hence the rated operational current of the contactor (unless the temperature drops at the same time). no derating is necessary up to 3000 m (9,840 ft.). derating factors to be applied above this altitude for main pole operational voltage and current (ac supply) are as follows. altitude 3500 m (11,480 ft.) 4000 m (13,120 ft.) 4500 m (14,760 ft.) 5000 m (16,400 ft.) rated operational voltage 0.90 0.80 0.70 0.60 rated operational current 0.92 0.90 0.88 0.86 ambient air temperature the temperature of the air surrounding the device, measured near to the device. the operating characteristics are given:  with no restriction for temperatures between ?5 and +55 c (+23 and +131 f)  with restrictions, if necessary, for temperatures between ?50 and +70 c (?58 and +149 f) rated operational current (ie) this is defined taking into account the rated operational voltage, operating rate and duty, utilization category and ambient temperature around the device. rated conventional thermal current (ith) f the current which a closed contactor can sustain for a mini mum of 8 hours without its temperature rise exceeding the limits given in the standards. permissible short time rating the current which a closed contactor can sustain for a short time after a period of no load, without dangerous overheating. rated operational voltage (ve) this is the voltage value which, in conj unction with the rated operational current, determines the use of the contactor or starter, and on which the corresponding tests and the utilizat ion category are based. for th ree-phase circuits it is expressed as the voltage between phases. apart from except ional cases such as rotor short-circuiting, the rated operational voltage ve is less than or equal to the rated insulation voltage vi. rated control circuit voltage (vc) the rated value of the control circuit voltage, on which the operating characteristics are bas ed. for ac applications, the values are given for a near sinusoidal wave form (less than 5% total harmonic distortion). rated insulation voltage (vi) this is the voltage value used to define the insulation characteristics of a devi ce and referred to in dielectric tests determining leakage paths and creepage distances . as the specifications are not identical for all standards, the rated value given for each of them is not necessarily the same. rated impulse withstand voltage (vimp) the peak value of a voltage surge which the device is able to withstand without breaking down. rated operational power (expressed in kw) the rated power of the standard motor which can be switched by the contactor, at the stated operational voltage. rated breaking capacity q this is the current value which the cont actor can break in accordance with the breaking conditions s pecified in the iec standard. rated making capacity q this is the current value which the c ontactor can make in accordance with t he making conditions s pecified in the iec standard. on-load factor (m) this is the ratio between the time the curre nt flows (t) and the duration of the cycle (t) cycle duration: duration of current flow + time at zero current pole impedance the impedance of one pole is the sum of the impedance of al l the circuit components between the input terminal and the output terminal. the impedance comprises a resistive component (r) and an inductive component (x=l ). the total impedance therefore depends on the frequency and is normally given for 50 hz. this average value is given for the pole at its rated operational current. electrical durability this is the average number of on-load oper ating cycles which the main pole cont acts can perform without maintenance. the electrical durability depends on t he utilization category, the rated operational current and the rated operational voltage. mechanical durability this is the average number of on-load oper ating cycles (i.e. with zero current flow through the main poles) which the contactor can perform without mechanical failure f conventional thermal current, in free air, conforming to iec standards. q for ac applications, the breaking and making capacities are expressed by the rms value of the symmetrical component of the shor t-circuit current. taking into account the maximum asymmetry which may exist in the circuit, the contacts therefore have to withstand a peak asymmetrical current which may be twi ce the rms symmetrical component. note: these definitions are extracted from standard iec 60947-1. t m = t t t
catalog 04 tesys ? k-line mini-contactors, overload relays, and accessories file 8502 contents description page general information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 mini-contactors characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 k-line voltage code table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 auxiliary contacts and timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 dimensions and mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 overload relays characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 dimensions, mounting, and schematics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 low-consumption mini-contactors characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 auxiliary contacts, timers, and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 dimensions and mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 k-line
tesys? k-line mini-contactors and starters general information ? 2001-2004 schneider electric all rights reserved 38 01/04 general information k-line mini-contactors, and overload relays are ideal for general-duty applications where small size and reliability are key concerns. they feature:  three contactor ratings for the usa market: ? k06 rated for 3 hp motors at 480 vac or 600 vac. ? k09 rated for 5 hp motors at 480 vac or 600 vac. ? k12 rated for 7.5 hp motors at 480 vac or 10 hp at 600 vac.  space savings ? the special magnet and armature structure allow for a dc coil-operated device with the same physical size and panel footprint of the ac coil version.  ip20-rated touch-safe terminals with both north american and international terminal markings  mountable on 35mm din rail or panel mount with screws  available in 3-pole contactor versions with built-in auxiliary contact for holding circuit or 4-pole contactor versions.  easily-installed accessories. ? 2-pole or 4-pole instantaneous auxiliary contact blocks with screw clamp, slip-on, or spring terminals. ? transient voltage surge suppressors. ? electronic 1 to 30 second on-delay timers.  four wiring methods to reduce installation time: ? captive screw terminals for use with either phillips or slotted head screwdrivers. ? slip-on terminals for quick installation of single 1/4" or double 1/8" tabs. ? terminal pins for soldering the contacto r directly to a printed circuit board. ? spring terminals for extreme-vibration applications.  control circuit flexibility all versions of the k-line mini -contactors are available with an ac, dc, or low-consumption dc operating coil. the low-consumption dc coil operating device can be energized by a low level dc signal from a computer or plc and includes built-in transient suppression and led ?on? indicator.  bimetallic overload relays the k-line class 10 bimetallic overload relays are ambient-compensated and include single-phase sensitivity for phase unbalance and phase loss protec tion. standard features include isolated n.c. trip contact and n.o. alarm contact, manual or au tomatic reset function, tamper resistant window for full load current settings, and test trip button. five pins connect to the contactor load side terminals ? three for the power circuit and two for the contro l circuit ? which eliminate customer wiring for the 3-wire control holding circuit.
tesys? k-line mini-contactors and starters characteristics of type lck and lpk contactors 39 01/04 ? 2001-2004 schneider electric all rights reserved characteristics of type lc\bk and lp\bk contactors environment rated insulation voltage (vi) conforming to iec 60947 v 690 conforming to vde 0110 gr c v 750 conforming to bs 5424, nf c 20-040 v 690 conforming to csa 22-2 no. 14, ul 508 v 600 rated impulse withstand voltage (vimp) kv 8 conforming to standards meets the essential requirements of the lv & emc directives iec 60947, nf c 63-110, vde 0660, bs 5424, ul508, csa 22-2 no. 14 approvals lc ? k06, lc ? k09, lc ? k12 lp ? k06, lp ? k09, lp ? k12 e164862 nldx (screw clamp) e164862 nldx2 (slip-on & solder pin) lr 43364 321104 protective treatment conforming to iec 60068 (din 50016) ?tc? (fungus-proof, tropicalization protection) degree of protection conforming to vde 0106 protection against direct finger contact ambient air temperature around the device storage - 50 to + 80c (-58 to +176f) operation - 25 to + 50c (-13 to +122f) maximum operating altitude without derating 2000 m (6562 ft.) operating position vertical axis without derating horizontal axis without derating derate current carrying capability by 15% when not mounted vertically flame resistance conforming to ul 94 self-extinguishing material v1 conforming to nf f 16-101 and 16-102 conforming to requirement 2 shock resistance (1/2 sine wave, 11 ms) contactor open 10 gn contactor closed 15 gn vibration resistance 5 to 300 hz contactor open 2 gn contactor closed 4 gn safe circuit separation conforming to vde 0106 and iec 60536 selv f , up to 400 v cabling min max max to iec 60947 screw-clamp terminals solid or stranded cable awg 1 x 18 2 x 14 or 1 x 12 ? solid cable mm 2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5 stranded cable without cable end mm 2 1 x 0.75 2 x 4 2 x 2.5 stranded cable with cable end mm 2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5 slip-on connectors clip 2 x 2.8mm or 1 x 6.35mm (2 x 0.110 in. or 1 x 0.250 in.) solder pins for printed circuit board with locating device between power and control circuits 4 mm x 35 microns tightening torque phillips no. 2 or 3/16? slotted head screwdriver 0.8 n ? m (7lb.-in.) terminal referencing conforming to standards en 50005 and en 50012 up to 5 contacts f safety extra low voltage. 90 90 1 8 0 90 90
tesys? k-line mini-contactors and starters characteristics of type lck and lpk contactors ? 2001-2004 schneider electric all rights reserved 40 01/04 pole characteristics conventional thermal current (ith) for ambient temperature 50 c (122 f) 20 a rated operational frequency 50/60 hz frequency limits of the operational current up to 400 hz rated operational voltage (ve) 690 vac rated making capacity i rms conforming to nf c 63-110 and iec 60947 lc ? k 06, lpi ? k 06, lc ? k 09, lp ? k 09 110 a lc ? k12, lp ? k12 144 a lc ? k16 160 a rated breaki ng capacity conforming to nf c 63-110 and iec 60947 220/ 230 v 380/ 400 v 415 v 440 v 500 v 660/ 690 v lc ? k06, lp ? k06, lc ? k09, lp ? k09 i rms 110 a 110 a 110 a 110 a 80 a 70 a lc ? k12, lp ? k12 ? ? ? 110 a 80 a 70 a lc ? k16 ? ? ? 110 a 80 a 70 a permissible short-time rating in free air for a time "t? from cold state ( 50 c [122 f]) 1 s5 s10 s30 s1 min3 min 15 min lc ? k06, lp ? k06, lc ? k09, lp ? k09 90 a 85 a 80 a 60 a 45 a 40 a 20 a lc ? k12, lp ? k12 lc ? k16 115 a 105 a 100 a 75 a 55 a 50 a 25 a short-circuit protection by circuit breaker select in accordance with nec and local codes by fuses max 400% of motor fla average impe dance/pole at ith and 50 hz 3 m ? at ith and 60 hz 3.6 m ? utilization in category ac-1: resistive circuit, heating, lighting (ve 440 v) maximum rated operational current for a temperature 50 c (122 f) 20 a maximum rated operational current for a temperature 70 c (158 f) 16 a for ve only rated operational current limits in relation to on-load factor and operating frequency on-load factor 90% 60% 30% 300 op. cycles/hour 13 a 15 a 18 a 120 op. cycles/hour 15 a 18 a 19 a 30 op. cycles/hour 19 a 20 a 20 a increase in operational current by paralleling of poles apply the following coefficients to the current values given above. these take into account the often unbalanced current distribution between poles 2 poles in parallel: k = 1.60 3 poles in parallel: k = 2.25 4 poles in parallel: k = 2.80 utilization in category ac-3 squirrel cage motors operational power according to the voltage voltage 50 or 60 hz 115 v 220 v 220/ 240 v 380/ 415 v 440/ 480 v 500/ 600 v 660/ 690 v 1-phase 3-phase lc ? k06, lp ? k06 motor ratings 0.37 kw 0.75 kw 1.5 kw 2.2 kw 3 kw 3 kw 3 kw lc ? k09, lp ? k09 motor ratings 0.55 kw 1.1 kw 2.2 kw 4 kw 4 kw 4 kw 4 kw lc ? k12, lp ? k12 motor ratings ? ? 3 kw 5.5 kw 5.5/4 (480) kw 4 kw 4 kw lc ? k16 motor ratings ? ? 4 kw 7.5 kw 5.5/4 (480) kw 4 kw 4 kw maximum operating rate (in operating cycles/ hour in relation to percentage of rated power) op. cycles/hour 600 900 1200 power 100% 75% 50% utilization in category ac-3 squirrel cage motors operational power according to the voltage voltage 50 or 60 hz 115 220 200/ 208 220/ 240 460/ 480 575/ 600 1-phase 3-phase lc ? k06, lp ? k06 motor ratings 0.5 hp 1 hp 1.5 hp 1.5 hp 3 hp 3 hp lc ? k09, lp ? k09 motor ratings 0.5 hp 1.5 hp 2 hp 3 hp 5 hp 5 hp lc ? k12, lp ? k12 motor ratings 0.5 hp 1.5 hp 3 hp 3 hp 7.5 hp 10 hp lc ? k16, lp ? k16 not ul listed or csa certified.
tesys? k-line mini-contactors and starters characteristics of type lck and lpk contactors 41 01/04 ? 2001-2004 schneider electric all rights reserved control circuit characteristics ty p e lc1lc2lc7lc8lp1lp2 rated control circuit voltage (vc) 12 to 690 vac f 24 to 230 vac 12 to 250 vdc f control voltage limits ( 50 c [122 f]) single voltage coil for operation q 0.8 to 1.15 vc 0.85 to 1.1 vc 0.8 to 1.15 vc for drop-out 0.20 vc 0.10 vc 0.10 vc average consumption at 20 c (68 f) and at vc inrush 30 va 3 va 3 w sealed 4.5 va 3 va 3 w heat dissipation 1.3 3 3 operating time at 20 c (68 f) and at vc between coil energization and: - opening of the n.c. contacts 5 to 15 ms 25 to 35 ms 25 to 35 ms - closing of the n.o. contacts 10 to 20 ms 30 to 40 ms 30 to 40 ms between coil de-energization and: - opening of the n.o. contacts 10 to 20 ms 30 ms 10 ms - closing of the n.c. contacts 15 to 25 ms 40 ms 15 ms maximum immunity to micro-breaks 2 ms 2 ms 2 ms maximum operating rate in operating cycles per hour 3600 3600 3600 mechanical durability at vc in millions of operating cycles 50/60 hz coil 10 5 10 5 ? ? dc coil ????105 f for mains supplies with a high level of interference (voltage surge > 800 v), use a suppressor module la4ke1fc (50 to 129 v) o r lafke1ug (130 to 250 v); see page 56. q lc1k16: 0.85 to 1.15 vc.
tesys? k-line mini-contactors and starters characteristics of type lck and lpk contactors ? 2001-2004 schneider electric all rights reserved 42 01/04 auxiliary contact characteristics and instantaneous contact blocks number of contacts on lc ? k or lp ? k1 on la1k 2 or 4 rated operational voltage (ve) up to 690 vac rated insulation voltage (vi) conforming to bs 5424 690 vac conforming to iec 60947 690 vac conforming to vde 0110 group c 750 vac conforming to csa c 22.2 no.14, ul 508 600 vac conventional thermal current (lth) for ambient temperature 50 c (122 f) 10 a frequency of operational current up to 400 hz minimum switching capacity v min (din 19 240) 17 vac i min 5 ma short-circuit protection conforming to iec 60947 and vde 0660, gl fuse 10 a rated making capacity conforming to iec 60947 i rms 110 a overload current permissible for 1 s 80 a 500 ms 90 a 100 ms 110 a insulation resistance > 10 m ? non-overlap distance linked contacts conforming to inrs and bia spec. 0.5 mm operational power of contacts conforming to iec 60947 ac supply, category ac-15 dc supply, category dc-13 electrical durability (valid up to 3600 operating cycles per hour) on an inductive load such as the coil of an electromagnet: making current (power factor 0.7) = 10 times the breaking current (power factor 0.4). electrical durability (valid up to 1200 operating cycles per hour, on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. v2448 110/ 127 220/ 230 440 600/ 690 v 24 48 110 220 440 600 1 million operating cycles va 48 96 240 440 880 1200 w 120 80 60 52 51 50 2 million operating cycles va 17 34 86 158 317 500 w 55 38 30 28 26 25 10 million operating cycles va 7 14 36 66 132 200 w 15 11 9 8 7 6 occasional making capacity va 1000 2050 5000 10000 13000 9000 w 720 600 400 300 230 200 1 breaking limit of contacts valid for maximum of 50 operating cycles at 10 s intervals (breaking current = making current x power factor 0.7). 2 electrical durability of contacts for: - 1 million operating cycles (2a) - 3 million operating cycles (2b) -10 million operating cycles (2c). 3 breaking limit of contacts valid for maximum of 20 operating cycles at 10 s intervals with current passing for 0.5 s per operating cycle. 4 thermal limit. power in broken va power in broken w 10 000 5000 3000 2000 1000 800 600 500 400 300 200 100 80 60 24 48 110 220 440 690 v 120 380 500 40 16 000 8000 6000 4000 2c 2b 4 1 2a 1000 700 500 300 200 100 80 60 50 40 30 20 10 8 6 12 24 48 110 220 440 600 v 250 200 140 100 50 20 2c 2b 2a 3 4 time constant in ms
tesys? k-line mini-contactors and starters selection of contactors for motor control 43 01/04 ? 2001-2004 schneider electric all rights reserved selection of contactors for motor control general-purpose contactors for ac control circuits the table below shows general-purpose contactors. the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready-to-tighten? position. for information on add-on auxiliary contact blocks and accessories, see page 54 to 58. horsepower ratings for north american applicati ons kilowatt ratings for in ternational applications type of connection auxiliary contacts catalog number p q weight lb. (kg) maximum horsepower rating category ac-3, 50/60 hz max. inductive current standard power ra tings of 3-phase motors, 50/60 hz in category ac-3 rated operational current, up to 440 v 1-phase 3-phase 220 v 230 v 380 v 415 v 440/500 v 660/690 v 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575/ 600 v hp hp hp hp hp hp a kw kw kw a n.o. n.c. 0.5 1 1.5 1.5 3 3 6 1.5 2.2 3 6 screw clamp 1? lc1k0610 ?? 0.40 (0.180) ?1 lc1k0601 ?? 0.40 (0.180) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc1k06107 ?? 0.40 (0.180) ?1 lc1k06017 ?? 0.40 (0.180) solder pins for printed circuit board 1? lc1k06105 ?? 0.46 (0.210) ?1 lc1k06015 ?? 0.46 (0.210) spring terminals 1? lc1k06103 ?? 0.40 (0.180) ?1 lc1k06013 ?? 0.40 (0.180) 0.51.523559 2.2 4 4 9 screw clamp 1? lc1k0910 ?? 0.40 (0.180) ?1 lc1k0901 ?? 0.40 (0.180) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc1k09107 ?? 0.40 (0.180) ?1 lc1k09017 ?? 0.40 (0.180) solder pins for printed circuit board 1? lc1k09105 ?? 0.46 (0.210) ?1 lc1k09015 ?? 0.46 (0.210) spring terminals 1? lc1k09103 ?? 0.40 (0.180) ?1 lc1k09013 ?? 0.40 (0.180) 0.5 1.5 3 3 7.5 10 12 3 5.5 4 (> 440) 5.5 (440) 12 screw clamp 1? lc1k1210 ?? 0.40 (0.180) ?1 lc1k1201 ?? 0.40 (0.180) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc1k12107 ?? 0.40 (0.180) ?1 lc1k12017 ?? 0.40 (0.180) solder pins for printed circuit board 1? lc1k12105 ?? 0.46 (0.210) ?1 lc1k12015 ?? 0.46 (0.210) spring terminals 1? lc1k12103 ?? 0.40 (0.180) ?1 lc1k12013 ?? 0.40 (0.180) not for north american applications ? not ul listed or csa certified 37.5 4 (440) 5.5 (440) 16 screw clamp 1? lc1k1610 ?? 0.40 (0.180) ?1 lc1k1601 ?? 0.40 (0.180) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc1k16107 ?? 0.40 (0.180) ?1 lc1k16017 ?? 0.40 (0.180) solder pins for printed circuit board 1? lc1k16105 ?? 0.46 (0.210) ?1 lc1k16015 ?? 0.46 (0.210) spring terminals 1? lc1k16103 ?? 0.40 (0.180) ?1 lc1k16013 ?? 0.40 (0.180) p use voltage codes on page 52 ?voltage code table? to complete catalog number. q for mains supplies with a high level of interference (voltage surge > 800 v), use a suppressor module la4ke1fc (50 to 129 v) or la4ke1ug (130 to 250 v), see page 56. lc1k06107 ?? lc1k0610 ?? lc1k09103
tesys? k-line mini-contactors and starters selection of contactors for motor control ? 2001-2004 schneider electric all rights reserved 44 01/04 sensitive-environment contacto rs for ac control circuits the tables below show the kilowatt ratings (for inte rnational applications) and horsepower ratings (for north american applications) of contactors for use in sensitive environments. they are recommended for use in areas sensitive to noise, high interference mains supplies, and so forth. the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready-to- tighten? position, and include a coil wit h a built-in rectifier and suppressor. for information on add-on auxiliary contact blocks and accessories, see page 54 to 58. horsepower ratings for north american applicatio ns kilowatt ratings for international applications type of connection auxiliary contacts catalog number p weight lb. (kg) maximum horsepower rating category ac-3, 50/60 hz max. inductive current standard power ra tings of 3-phase motors, 50/60 hz in category ac-3 rated operational current, 440v up to: 1-phase 3-phase 220 v 230 v 380 v 415 v 440/500 v 660/690 v 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575/ 600 v hp hp hp hp hp hp a kw kw kw a n.o. n.c. 0.5 1 1.5 1.5 3 3 6 1.5 2.2 3 6 screw clamp 1? lc7k0610 ?? 0.50 (0.225) ?1 lc7k0601 ?? 0.50 (0.225) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc7k06107 ?? 0.50 (0.225) ?1 lc7k06017 ?? 0.50 (0.225) solder pins for printed circuit board 1? lc7k06105 ?? 0.50 (0.225) ?1 lc7k06015 ?? 0.50 (0.225) 0.51.523559 2.2 4 4 9 screw clamp 1? lc7k0910 ?? 0.50 (0.225) ?1 lc7k0901 ?? 0.50 (0.225) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc7k09107 ?? 0.50 (0.225) ?1 lc7k09017 ?? 0.56 (0.255) solder pins for printed circuit board 1? lc7k09105 ?? 0.56 (0.255) ?1 lc7k09015 ?? 0.50 (0.225) 0.5 1.5 3 3 7.5 10 12 3 5.5 4 (> 440) 5.5 (440) 12 screw clamp 1? lc7k1210 ?? 0.50 (0.225) ?1 lc7k1201 ?? 0.50 (0.225) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc7k12107 ?? 0.50 (0.225) ?1 lc7k12017 ?? 0.50 (0.225) solder pins for printed circuit board 1? lc7k12105 ?? 0.56 (0.255) ?1 lc7k12015 ?? 0.56 (0.255) p use voltage codes on page 52 ?voltage code table? to complete catalog number. lc7k06105 ??
tesys? k-line mini-contactors and starters selection of contactors for motor control 45 01/04 ? 2001-2004 schneider electric all rights reserved three-pole contactors for dc control circuits the table below shows the kilowatt ratings (for in ternational applications) and horsepower ratings (for north american applications) for three-pole contactors for dc control circuits. t he contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wir e termination screws are in the open, ?ready-to- tighten? position. for information on add-on auxiliary contact blocks and accessories, see page 54 to 58. horsepower ratings for north american applicati ons kilowatt ratings for international applications type of connection auxiliary contacts catalog number p weight lb. (kg) maximum horsepower rating category ac-3, 50/60 hz max. inductive current standard power ratings of 3-phase motors, 50/60 hz in category ac-3 rated operationa l current, 440v up to: 1-phase 3-phase 220 v 230 v 380 v 415 v 440/500 v 660/690 v 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575/ 600 v hp hp hp hp hp hp a kw kw kw a n.o. n.c. 1.5 2.2 3 6 0.5 1 1.5 1.5 3 3 6 screw clamp 1? lp1k0610 ?? 0.50 (0.225) ?1 lp1k0601 ?? 0.50 (0.225) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lp1k06107 ?? 0.50 (0.225) ?1 lp1k06017 ?? 0.50 (0.225) solder pins for printed circuit board 1? lp1k06105 ?? 0.56 (0.255) ?1 lp1k06015 ?? 0.56 (0.255) spring terminals 1? lp1k06103 ?? 0.50 (0.225) ?1 lp1k06013 ?? 0.50 (0.225) 2.244 90.51.523559 screw clamp 1? lp1k0910 ?? 0.50 (0.225) ?1 lp1k0901 ?? 0.50 (0.225) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lp1k09107 ?? 0.50 (0.225) ?1 lp1k09017 ?? 0.50 (0.225) solder pins for printed circuit board 1? lp1k09105 ?? 0.50 (0.225) ?1 lp1k09015 ?? 0.56 (0.255) spring terminals 1? lp1k09103 ?? 0.50 (0.225)) ?1 lp1k09013 ?? 0.50 (0.225) 35.5 4 (> 440 v) 5.5 (440 v) 12 0.5 1.5 3 3 7.5 10 12 screw clamp 1? lp1k1210 ?? 0.50 (0.225) ?1 lp1k1201 ?? 0.50 (0.225) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lp1k12107 ?? 0.50 (0.225) ?1 lp1k12017 ?? 0.50 (0.225) solder pins for printed circuit board 1? lp1k12105 ?? 0.56 (0.255) ?1 lp1k12015 ?? 0.56 (0.255) spring terminals 1? lp1k12103 ?? 0.50 (0.225) ?1 lp1k12013 ?? 0.50 (0.225) p use voltage codes on page 52 ?voltage code table? to complete catalog number. lp1k0610 ?? lp1k06107 ??
tesys? k-line mini-contactors and starters selection of contactors for resistive loads ? 2001-2004 schneider electric all rights reserved 46 01/04 selection of contactors for resistive loads three- and four-pole contactors for ac control circuits the tables below show general-purpose and sensitiv e-environment three- and four-pole contactors for ac control circuits. (the sensitive-environment cont actors are recommended for use in areas sensitive to noise, high interference mains supplies, and so forth.) the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready-to -tighten? position. in addition, the sensitive-environment contactors include a coil with a built-in rectifier and suppressor. for information on add-on auxiliary contact blocks and accessories, see page 54 to 58. general-purpose contactors f non-inductive loads category ac-1 maximum current at 50 c (122 f) type of connection power poles auxiliary contacts catalog number p weight lb. (kg) a n.o. n.c. n.o. n.c. 20 screw clamp 3?1? lc1k0910 ?? 0.56 (0.255) 3??1 lc1k0901 ?? 0.56 (0.255) 4??? lc1k09004 ?? 0.40 (0.180) 22?? lc1k09008 ?? 0.40 (0.180) slip-on 1 x 0.25 in. or 2 x 0.11 in. 3?1? lc1k09107 ?? 0.56 (0.255) 3??1 lc1k09017 ?? 0.56 (0.255) 4??? lc1k090047 ?? 0.40 (0.180) 22?? lc1k090087 ?? 0.40 (0.180) solder pins for printed circuit board 3?1? lc1k09105 ?? 0.56 (0.255) 3??1 lc1k09015 ?? 0.56 (0.255) 4??? lc1k090045 ?? 0.46 (0.210) 22?? lc1k090085 ?? 0.46 (0.210) spring terminals 3?1? lc1k09103 ?? 0.56 (0.255) 3??1 lc1k09013 ?? 0.56 (0.255) 4??? lc1k090043 ?? 0.46 (0.210) 22?? lc1k090083 ?? 0.46 (0.210) sensitive-environment contactors 20 screw clamp 3?1? lc7k0910 ?? 0.56 (0.255) 3??1 lc7k0901 ?? 0.56 (0.255) 4??? lc7k09004 ?? 0.56 (0.255) 22?? lc7k09008 ?? 0.56 (0.255) slip-on 1 x 0.25 in. or 2 x 0.11 in. 3?1? lc7k09107 ?? 0.56 (0.255) 3??1 lc7k09017 ?? 0.56 (0.255) 4??? lc7k090047 ?? 0.56 (0.255) 22?? lc7k090087 ?? 0.56 (0.255) solder pins for printed circuit board 3?1? lc7k09105 ?? 0.56 (0.255) 3??1 lc7k09015 ?? 0.56 (0.255) 4??? lc7k090045 ?? 0.56 (0.255) 22?? lc7k090085 ?? 0.56 (0.255) f for mains supplies with a high level of interference (voltage surge > 800 v), use a suppressor module la4ke1fc (50 to 129 v) or lafke1ug (130 to 250 v), see page 56. p use voltage codes on page 52 ?voltage code table? to complete catalog number. lc7k090047 ?? lc1k09004
tesys? k-line mini-contactors and starters selection of contactors for resistive loads 47 01/04 ? 2001-2004 schneider electric all rights reserved three- and four-pole contact ors for dc control circuits the table below shows three- and four-pole contactors for dc control circuits. the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wir e termination screws are in the open, ?ready-to- tighten? position. for information on add-on auxiliary contact blocks and accessories, see page 54 to 58. non-inductive loads category ac-1 maximum current at 50 c (122 f) type of connection power poles auxiliary contacts catalog number p weight lb. (kg) a n.o. n.c. n.o. n.c. 20 screw clamp 3?1? lp1k0910 ?? 0.56 (0.225) 3??1 lp1k0901 ?? 0.56 (0.225) 4??? lp1k09004 ?? 0.56 (0.225) 22?? lp1k09008 ?? 0.56 (0.225) slip-on 1 x 0.25 in. or 2 x 0.11 in. 3?1? lp1k09107 ?? 0.56 (0.225) 3??1 lp1k09017 ?? 0.56 (0.225) 4??? lp1k090047 ?? 0.56 (0.225) 22?? lp1k090087 ?? 0.56 (0.225) solder pins for printed circuit board 3?1? lp1k09105 ?? 0.56 (0.225) 3??1 lp1k09015 ?? 0.56 (0.225) 4??? lp1k090045 ?? 0.56 (0.225) 22?? lp1k090085 ?? 0.56 (0.225) spring terminals 3?1? lc1k09103 ?? 0.56 (0.225) 3??1 lc1k09013 ?? 0.56 (0.225) 4??? lc1k090043 ?? 0.46 (0.210) 22?? lc1k090083 ?? v 0.46 (0.210) p use voltage codes on page 52 ?voltage code table? to complete catalog number. lp1k09004 ??
tesys? k-line mini-contactors and starters selection of reversing contactors for motor control ? 2001-2004 schneider electric all rights reserved 48 01/04 selection of reversing contactors for motor control three-pole reversing contactors for ac control circuits the table below shows three-pole reversing contactors with integrated mechanical interlock. the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready-to-tighten? positi on. customer wiring is required to connect coil terminations to electrical interlock; see page 60 (top row, center wiring diagram). for information on add-on auxiliary contact blocks and accessories, see page 54 to 58. horsepower ratings for north american applicatio ns kilowatt ratings for international applications type of connection auxiliary contacts catalog number p c weight lb. (kg) maximum horsepower rating category ac-3, 50/60 hz max. inductive current standard power ra tings of 3-phase motors, 50/60 hz in category ac-3 rated operational current, up to 440 v 1-phase 3-phase 220 v 230 v 380 v 415 v 440/500 v 660/690 v 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575/ 600 v hp hp hp hp hp hp a kw kw kw a n.o. n.c. 0.5 1 1.5 1.5 3 3 6 1.5 2.2 3 6 screw clamp q 1? lc2k0610 ?? 0.86 (0.390) ?1 lc2k0601 ?? 0.86 (0.390) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc2k06107 ?? 0.81 (0.370) ?1 lc2k06017 ?? 0.81 (0.370) solder pins for printed circuit board 1? lc2k06105 ?? 0.95 (0.430) ?1 lc2k06015 ?? 0.95 (0.430) spring terminals 1? lc2k06103 ?? 0.86 (0.390) ?1 lc2k06013 ?? 0.86 (0.390) 0.51.523559 2.2 4 4 9 screw clamp q 1? lc2k0910 ?? 0.86 (0.390) ?1 lc2k0901 ?? 0.86 (0.390) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc2k09107 ?? 0.86 (0.390) ?1 lc2k09017 ?? 0.86 (0.390) solder pins for printed circuit board 1? lc2k09105 ?? 0.95 (0.430) ?1 lc2k09015 ?? 0.95 (0.430) spring terminals 1? lc2k09103 ?? 0.86 (0.390) ?1 lc2k09013 ?? 0.86 (0.390) 0.5 1.5 3 3 7.5 10 12 3 5.5 4 (> 440) 5.5 (440) 12 screw clamp q 1? lc2k1210 ?? 0.86 (0.390) ?1 lc2k1201 ?? 0.86 (0.390) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc2k12107 ?? 0.86 (0.390) ?1 lc2k12017 ?? 0.86 (0.390) solder pins for printed circuit board 1? lc2k12105 ?? 0.95 (0.430) ?1 lc2k12015 ?? 0.95 (0.430) spring terminals 1? lc2k12103 ?? 0.86 (0.390) ?1 lc2k12013 ?? 0.86 (0.390) not for north american applications ? not ul listed or csa certified 37.5 4 (440) 5.5 (440) 16 screw clamp q 1? lc2k1610 ?? 0.86 (0.390) ?1 lc2k1601 ?? 0.86 (0.390) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc2k16107 ?? 0.86 (0.390) ?1 lc2k16017 ?? 0.86 (0.390) solder pins for printed circuit board 1? lc2k16105 ?? 0.95 (0.430) ?1 lc2k16015 ?? 0.95 (0.430) spring terminals 1? lc2k16103 ?? 0.86 (0.390) ?1 lc2k16013 ?? 0.86 (0.390) p use voltage codes on page 52 ?voltage code table? to complete catalog number. c for mains supplies with a high level of interference (voltage surge > 800 v), use a suppressor module la4ke1fc (50 to 129 v) or la4ke1ug (130 to 250 v), see page 56. q pre-wired power circuit connections are standard on screw clamp versions. lc2k06107 ?? lc2k0610 ?? lc2k09103
tesys? k-line mini-contactors and starters selection of reversing contactors for motor control 49 01/04 ? 2001-2004 schneider electric all rights reserved sensitive-environment reversing co ntactors for ac control circuits the tables below show the kilowatt ratings (for in ternational applications) and horsepower ratings (for north american applications) for reversing contactors with mechanical interlock for use in sensitive environments. they are recommended for use in areas sensitive to noise, high interference mains supplies, and so forth. a coil with incor porated rectifier and suppressor is standard. the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready-to-tighten? position. customer wir ing is required to connect coil terminations to electrical interlock; see page 60 (top row, center wiring diagram). for information on add-on auxiliary contact blocks and accessories, see page 54 to 58. horsepower ratings for north american applicati ons kilowatt ratings for international applications type of connection auxiliary contacts catalog number p weight lb. (kg) maximum horsepower rating category ac-3, 50/60 hz max. inductive current standard power ratings of 3-phase motors, 50/60 hz in category ac-3 rated operational current, up to 440 v 1-phase 3-phase 220 v 230 v 380 v 415 v 440/500 v 660/690 v 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575/ 600 v hp hp hp hp hp hp a kw kw kw a n.o. n.c. 0.5 1 1.5 1.5 3 3 6 1.5 2.2 3 6 screw clamp q 1? lc8k0610 ?? 1.05 (0.480) ?1 lc8k0601 ?? 1.05 (0.480) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc8k06107 ?? 1.00 (0.460) ?1 lc8k06017 ?? 1.00 (0.460) solder pins for printed circuit board 1? lc8k06105 ?? 1.14 (0.520) ?1 lc8k06015 ?? 1.14 (0.520) 0.51.523559 2.2 4 4 9 screw clamp q 1? lc8k0910 ?? 1.05 (0.480) ?1 lc8k0901 ?? 1.05 (0.480) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc8k09107 ?? 1.00 (0.460) ?1 lc8k09017 ?? 1.00 (0.460) solder pins for printed circuit board 1? lc8k09105 ?? 1.14 (0.520) ?1 lc8k09015 ?? 1.14 (0.520) 0.5 1.5 3 3 7.5 10 12 3 5.5 4 (> 440) 5.5 (440) 12 screw clamp q 1? lc8k1210 ?? 1.05 (0.480) ?1 lc8k1201 ?? 1.05 (0.480) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lc8k12107 ?? 1.00 (0.460) ?1 lc8k12017 ?? 1.00 (0.460) solder pins for printed circuit board 1? lc8k12105 ?? 1.14 (0.520) ?1 lc8k12015 ?? 1.14 (0.520) p use voltage codes on page 52 ?voltage code table? to complete catalog number. q pre-wired power circuit connections are standard on screw clamp versions. lc8k06105 ??
tesys? k-line mini-contactors and starters selection of reversing contactors for motor control ? 2001-2004 schneider electric all rights reserved 50 01/04 three-pole reversing contactors for dc control circuits the table below show the kilowatt ratings (for international applications) and horsepower ratings (for north american applications) for three-pole reversing c ontactors with integrated mechanical interlock for dc control circuits. the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready-to-tighten ? position. customer wiring is required to connect coil terminations to electrical interlock; see page 60 (top row, center wiring diagram). for information on add-on auxiliary contact blocks and accessories, see page 54 to 58. horsepower ratings for north american applicati ons kilowatt ratings for international applications rated operation al current in ac-3 up to 400 v type of connection auxiliary contacts catalog number p weight lb. (kg) maximum horsepower ratings maximum inductive current in ac-3 category standard power ratings of 3-phase motors 50/ 60 hz in category ac-3 1- phase 50/60 hz 3- phase 50/60 hz 220 v 230 v 380 v 415 v 440/500 v 660/690 v 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575/ 600 v hp hp hp hp hp hp a kw kw kw a n.o. n.c. 0.5 1 1.5 1.5 3 3 6 1.5 2.2 3 6 screw clamp q 1? lp2k0610 ?? 1.05 (0.480) ?1 lp2k0601 ?? 1.05 (0.480) slip-on 1 x 0.25 in. or 2 x 0.11 in. 1? lp2k06107 ?? 1.00 (0.460) lp2k06017 ?? 1.00 (0.460) solder pins for printed circuit board ?1 lp2k06105 ?? 1.14 (0.520) 1? lp2k06015 ?? 1.14 (0.520) spring terminal 1? lp2k06103 ?? 1.05 (0.480) ?1 lp2k06013 ?? 1.05 (0.480) 0.51.52 3559 2.2 4 4 9 screw clamp q ?1 lp2k0910 ?? 1.05 (0.480) 1? lp2k0901 ?? 1.05 (0.480) slip-on 1 x 0.25 in. or 2 x 0.11 in. ?1 lp2k09107 ?? 1.00 (0.460) 1? lp2k09017 ?? 1.00 (0.460) solder pins for printed circuit board ?1 lp2k09105 ?? 1.14 (0.520) 1? lp2k09015 ?? 1.14 (0.520) spring terminal 1 lp2k09103 ?? 1.14 (0.520) 1 lp2k09013 ?? 1.14 (0.520) 0.5 1.5 3 3 7.5 10 12 3 5.5 4 (> 440) 5.5 (440) 12 screw clamp q ?1 lp2k1210 ?? 1.05 (0.480) 1? lp2k1201 ?? 1.05 (0.480) slip-on 1 x 0.25 in. or 2 x 0.11 in. ?1 lp2k12107 ?? 1.00 (0.460) 1? lp2k12017 ?? 1.00 (0.460) solder pins for printed circuit board ?1 lp2k12105 ?? 1.14 (0.520) 1? lp2k12015 ?? 1.14 (0.520) spring terminal 1 lp2k12103 ?? 1.14 (0.520) 1 lp2k12013 ?? 1.14 (0.520) p use voltage codes on page 52 ?voltage code table? to complete catalog number. q pre-wired power circuit connections are standard on screw clamp versions. lp2k06107 ?? lp2k0610 ??
tesys? k-line mini-contactors and starters selection of contactors for resistive loads 51 01/04 ? 2001-2004 schneider electric all rights reserved selection of reversing contactors for resistive loads three- and four-pole contact ors for ac control circuits the tables below show general purpose and sensit ive-environment three-pole reversing and four-pole change over contactors for ac control circuits. th e sensitive-environment contactors are recommended for use in areas sensitive to noise, high interfer ence mains supplies, and so forth. the contactors incorporate an integrated mechanical interlock. both types of contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready-to-tighten? position. in addition, the sensitiv e-environment contactors include a coil with a built-in rectifier and suppressor. customer wiring is required to connect coil terminations to the electrical interlock; se e page 60 (top row, center wiring diagram). for information on add-on auxiliary contact blocks and accessories, see page 54 to 58. general-purpose contactors f non-inductive loads category ac-1 maximum current at 50 c (122 f) type of connection power poles auxiliary contacts catalog number p weight lb. (kg) a n.o. n.c. n.o. n.c. 20 screw clamp q 3?1? lc2k0910 ?? 0.86 (0.390) 3??1 lc2k0901 ?? 0.86 (0.390) 4??? lc2k09004 ?? 0.84 (0.380) slip-on 1 x 0.25 in. or 2 x 0.11 in. 3??1 lc2k09107 ?? 0.81 (0.370) 3?1? lc2k09017 ?? 0.81 (0.370) 4??? lc2k090047 ?? 0.81 (0.370) solder pins for circuit board 3?11 lc2k09105 ?? 0.95 (0.430) 3??? lc2k09015 ?? 0.95 (0.430) 4??? lc2k090045 ?? 0.95 (0.430) spring terminals 3?11 lc2k09103 ?? 0.86 (0.390) 3??? lc2k09013 ?? 0.86 (0.390) 4??? lc2k090043 ?? 0.86 (0.390) sensitive-environment contactors 20 screw clamp q 3?1? lc8k0910 ?? f 1.05 (0.480) 3??1 lc8k0901 ?? f 1.05 (0.480) 4??? lc8k09004 ?? 1.03 (0.470) slip-on 1 x 0.25 in. or 2 x 0.11 in. 3??1 lc8k09107 ?? 1.01 (0.460) 3?1? lc8k09017 ?? 1.01 (0.460) 4??? lc8k090047 ?? 1.01 (0.460) solder pins for circuit board 3?11 lc8k09105 ?? 1.14 (0.520) 3??? lc8k09015 ?? 1.14 (0.520) 4??? lc8k090045 ?? 1.14 (0.520) f for mains supplies with a high level of interference (voltage surge > 800 v), use a suppressor module la4ke1fc (50 to 129 v) or lafke1ug (130 to 250 v), see page 56. p use voltage codes on page 52 ?voltage code table? to complete catalog number. q pre-wired power circuit connections are standard on screw clamp versions. lc2k09004 ?? lc8k09105 ??
tesys? k-line mini-contactors and starters voltage code table ? 2001-2004 schneider electric all rights reserved 52 01/04 voltage code table three- and four-pole contactors for dc control circuits the table below shows general-purpose three-pole re versing and four-pole change over contactors for dc control circuits. the contactors incor porate an integrated mechanical interlock. the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready-to-tighten? positi on. customer wiring is required to connect coil terminations to the electrical interlock; see page 60 (top row, center wiring diagram). for information on add-on auxiliary contact blocks and accessories, see page 54 to 58. non-inductive loads category ac-1 maximum current at 50 c (122 f) type of connection power poles auxiliary contacts catalog number p weight lb. (kg) a n.o. n.c. n.o. n.c. 20 screw clamp q 3?1? lp2k0910 ?? 1.05 (0.480) 3??1 lp2k0901 ?? 1.05 (0.480) 4??? lp2k09004 ?? 1.05 (0.480) slip-on 1 x 0.25 in. or 2 x 0.11 in. 3??1 lp2k09107 ?? 1.01 (0.460) 3?1? lp2k09017 ?? 1.01 (0.460) 4??? lp2k090047 ?? 1.01 (0.460) solder pins for circuit board 3?11 lp2k09105 ?? 1.14 (0.520) 3??? lp2k09015 ?? 1.14 (0.520) 4??? lp2k090045 ?? 1.14 (0.520) p use voltage codes below to complete the catalog number. q pre-wired power circuit connections are standard on screw clamp versions. lc2k09004 ?? k-line voltage code table k-line voltage code voltage frequency k-line (see notes at end of table) lc1k lc2k notes k1, k2 lc7k lc8k note k4 lp1k lp2k notes k2, k3 lp4k lp5k 5 low consump dc ---- 12 50/60 j7 - - - 50 - - - - dc - - jd - low consump dc ---jw3 wide range dc ---- 20 50/60 z7 - - - 50 - - - - 60 - - - - dc - - zd - low consump dc ---zw3 24 50/60 b7 note k2 b7 - - 50 - - - - 60 - - - - 40-400 - - - - dc - - bd note k2 - low consump dc ---bw3 wide range dc ---- 36 50/60 c7 - - - dc - - cd - wide range dc ---- 42 50/60 d7 d7 - - 50 - - - - 60 - - - - 48 50/60 e7 e7 - - 50 - - - - 60 - - - - 40-400 - - - - dc - - ed - low consump dc ---ew3 wide range dc ---- 60 50/60 - - - - dc - - nd - 72 dc - - sd - low consump dc ---sw3 wide range dc ---- 96 low consump dc ---- 100 50/60 - - - - dc - - kd - 110 50/60 f7 f7 - - 50 - - - - 60 - - - - 40-400 - - - - dc - - fd - low consump dc ---fw3 wide range dc ---- k-line voltage code (continued) voltage frequency k-line (see notes at end of table) lc1k lc2k notes k1, k2 lc7k lc8k note k4 lp1k lp2k notes k2, k3 lp4k lp5k
tesys? k-line mini-contactors and starters voltage code table 53 01/04 ? 2001-2004 schneider electric all rights reserved 110/127 40-400 - - - - 115 50/60 fe7 fe7 - - 50 - - - - 40-400 - - - - 120 50/60 g7 g7 - - 50 - - - - 60 - - - - 40-400 - - - - dc - - - - low consump dc ---gw3 125 dc - - gd - 127 50/60 fc7 - - - 60 - - - - 40-400 - - - - 155 dc - - pd - 174 dc - - qd - 200 50/60 - - - - dc - - ld - 200/208 50/60 l7 - - - 60 - - - - 40-400 - - - - 208 50/60 - - - - 60 - - - - 40-400 - - - - 220 50/60 - m7 - - 50 - - - - 60 - - - - 40-400 - - - - dc - - md - low consump dc ---- wide range dc ---- 220/230 50/60 m7 - - - 50 - - - - 60 - - - - 40-400 - - - - dc - - - - 220/240 40-400 - - - - dc - - - - 230 50/60 p7 - - - 50 - - - - 60 - - - - 40-400 - - - - dc - - mpd - 230/240 50/60 u7 note k4 u7 - - 240 50/60 - - - - 50 - - - - 60 - - - - 40-400 - - - - dc - - mud - 250 dc - - ud - low consump dc ---- 256 50/60 w7 - - - 50 - - - - 277 50/60 ue7 - - - 50 - - - - 40-400 - - - - 380 50/60 - - - - 50 - - - - 60 - - - - 40-400 - - - - k-line voltage code (continued) voltage frequency k-line (see notes at end of table) lc1k lc2k notes k1, k2 lc7k lc8k note k4 lp1k lp2k notes k2, k3 lp4k lp5k 380/400 50/60 q7 note k4 --- 50 - - - - 60 - - - - 40-400 - - - - dc - - - - 380/440 40-400 - - - - 400 50/60 v7 - - - 50 - - - - 40-400 - - - - 400/415 50/60 n7 - - - 415 50/60 - - - - 50 - - - - 40-400 - - - - 415-440 50 - - - - 40-400 - - - - 440 50/60 r7 - - - 50 - - - - 60 - - - - 40-400 - - - - dc - - - - 440/460 dc - - - - 460/480 60 - - - - 480 50/60 t7 - - - 50 - - - - 60 - - - - 40-400 - - - - 500 50/60 s7 - - - 50 - - - - 40-400 - - - - 575 50/60 sc7 - - - 60 - - - - 600 50/60 x7 - - - 60 - - - - 40-400 - - - - 660 50 - - - - 60 - - - - 660/690 50/60 y7 - - - notes: k1 up to and including 240 v, coil with integral suppression device (bi-directional diode): add 2 to the requested voltage code. ex. j72 k2 for voltage codes b7 or bd, when connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 v coil (voltage code z7 for ac or zd for dc) . this coil compensates for incurred voltage drop. k3 coil with integral suppression device available (bidirectional diode): add 3 to the requested voltage code. ex jd3. k4 for voltage codes m7, u7, q7, n7, y7 and all lc7k and lc8k devices, operating range is 0.85 - 1.10 of nominal. for all other lc1k and lc2k the operating range is 0.80 - 1.15 of nominal. k-line voltage code (continued) voltage frequency k-line (see notes at end of table) lc1k lc2k notes k1, k2 lc7k lc8k note k4 lp1k lp2k notes k2, k3 lp4k lp5k
tesys? k-line mini-contactors and starters selection of auxiliary contacts and timers ? 2001-2004 schneider electric all rights reserved 54 01/04 selection of auxiliary contacts and timers xx lc1/lc7/lp1k lc1/lc7/lp1k la1 kn p lc1/lc7/lp1k la1kn m la1kn la1kn la2kt2
tesys? k-line mini-contactors and starters selection of auxiliary contacts and timers 55 01/04 ? 2001-2004 schneider electric all rights reserved instantaneous auxili ary contact blocks for type lck and lpk contactors q see pages 59 and 60 for actual terminal markings. electronic time-delay auxiliary contact blocks for type lck and lpk contactors recommended for standard applications. clip-on front mounting, 1 block per contactor type of connection type of contactor auxiliary contacts catalog number weight lb. (kg) n.o. n.c. screw clamp lc1, lc2 lc7, lc8 lp1, lp2 3- or 4-pole 2? la1kn20 0.10 (0.045) ?2 la1kn02 0.10 (0.045) 11 la1kn11 0.10 (0.045) 4? la1kn40 0.10 (0.045) 31 la1kn31 0.10 (0.045) 22 la1kn22 0.10 (0.045) 13 la1kn13 0.10 (0.045) ?4 la1kn04 0.10 (0.045) slip-on 1 x 0.25 in. or 2 x 0.11 in. lc1, lc2 lc7, lc8 lp1, lp2 3- or 4-pole 2? la1kn207 0.10 (0.045) ?2 la1kn027 0.10 (0.045) 11 la1kn117 0.10 (0.045) 4? la1kn407 0.10 (0.045) 31 la1kn317 0.10 (0.045) 22 la1kn227 0.10 (0.045) 13 la1kn137 0.10 (0.045) ?4 la1kn047 0.10 (0.045) spring terminals lc1, lc2 lp1, lp2 3- or 4-pole 2? la1kn203 0.10 (0.045) ?2 la1kn023 0.10 (0.045) 11 la1kn113 0.10 (0.045) 4? la1kn403 0.10 (0.045) 31 la1kn313 0.10 (0.045) 22 la1kn223 0.10 (0.045) 13 la1kn133 0.10 (0.045) ?4 la1kn043 0.10 (0.045) with terminal referencing conforming to standard en 50012. clip-on front mounting, 1 block per contactor screw clamp with terminal referencing conforming to standard en 50012 q lc1, lc2 lc7, lc8 lp1, lp2 3-pole + n.o. ?2 la1kn02m 0.10 (0.045) 11 la1kn11m 0.10 (0.045) 31 la1kn31m 0.10 (0.045) 22 la1kn22m 0.10 (0.045) 13 la1kn13m 0.10 (0.045) lc1, lc2 lc7, lc8 lp1, lp2 4-pole 11 la1kn11p 0.10 (0.045) 22 la1kn22p 0.10 (0.045) ? relay output, with common point changeover contact, ac or dc 240 vac, 2 a maximum. ? control voltage: 0.85 to 1.1 vc. ? maximum switching capacity: 250 va or 150 w. ? operating temperature: -10 to + 60 c (14 to 140 f). ? reset time: 1.5 s during the time delay period, 0.5 s after the time delay period. clip-on front mounting, 1 block per contactor voltag e type timing range s auxiliary contacts catalog number weight lb. (kg) v spdt ac or dc 24 to 48 on-delay 1 to 30 1 la2kt2e 0.09 (0.040) ac 110 to 240 on-delay 1 to 30 1 la2kt2u 0.09 (0.040)
tesys? k-line mini-contactors and starters selection of accessories ? 2001-2004 schneider electric all rights reserved 56 01/04 selection of accessories coil suppressor modules with an led indicator for type lck and lpk contactors mounting and marking accessories cabling accessories mounting and connection type for voltages: sold in lots of catalog number weight lb. (kg) clip-on mounting on the front of lc1 and lp1 contactors. no tools required. varistor c ac and dc 12 to 24 v 5 la4ke1b 0.02 (0.010) ac and dc 32 to 48 v 5 la4ke1e 0.02 (0.010) ac and dc 50 to 129 v 5 la4ke1fc 0.02 (0.010) ac and dc 201 to 250 v 5 la4ke1ug 0.02 (0.010) diode + zener diode f dc 12 to 24 v 5 la4kc1b 0.02 (0.010) dc 32 to 48 v 5 la4kc1e 0.02 (0.010) rc q ac 220 to 250 v 5 la4ka1u 0.02 (0.010) c protection by limitation of the transient voltage up to 2 vc maximum. maximum reduction of transient voltage peaks. slight time delay on drop-out (1.1 to 1.5 times the normal time). f no overvoltage or oscillation frequency. polarized component. slig ht time delay on drop-out (1.1 to 1.5 times the normal time). q protection by limitation of the transient voltage up to 3 vc maximum and limitation of the oscillation frequency. slight time delay on drop-out (1.2 to 2 times the normal time). description application sold in lots of unit catalog number weight lb. (kg) mounting plates c for mounting on 1 ' rail clip-on 1 la9d973 0.05 (0.025) for mounting on 2 ' rails 110/120 mm mounting centers 10 dx1ap25 0.14 (0.065) marker holder clip-on onto front of contactor 100 la9d90 0.002 (0.001) clip-in markers 4 maximum per contactor strips of 10 identical numbers 0 to 9 25 ab1r ? q 0.004 (0.002) strips of 10 identical capital letters a to z 25 ab1g ? q 0.004 (0.002) 35mm " din rail (7.5mm deep x 2m long) 10 am1dp200 2.88 (1.310) 35mm " din rail (15mm deep x 2m long) 10 am1ed200 1.44 (0.650) c order 1 mounting plate for a contactor and 2 mounting plates for a reversing contactor. q complete the catalog number by replacing the ? with the required number or character. description application sold in lots of unit catalog number weight kg (lb.) paralleling links for 2-poles with screw clamp terminals 4 la9e01 0.02 (0.010) for 4-poles with screw clamp terminals 2 la9e02 0.03 (0.015) power connections: 6 required per contactor for 3-pole reversing contactors for motor control for contactors with screw clamp terminals 100 la9k0969 0.02 (0.010) power connections: 4 required per contactor for 4-pole changeover contactor pairs for contactors with screw clamp terminals 100 la9k0970 0.02 (0.010) la4k ?? dx1ap25 la9e01
tesys? k-line mini-contactors and starters dimensions and mounting of type lck and lpk contactors 57 01/04 ? 2001-2004 schneider electric all rights reserved dimensions and mounting of type lc\bk and lp\bk contactors xxx contactors lc1k, lc7k, lp1k on panel on mounting rail am1dp200 or am1de200 1.4 in. (35 mm) din rail on one asymmetrical rail dz5mb with clip-on mounting plate la9d973 dx1ap25 on printed circuit board electronic time-delay auxiliary contact blocks la2kt on contactor suppressor modules la4k ? on contactor 57 31 2.24 1.22 la1 k 58 2.28 50 1.97 == 35 1.38 45 1.78 = = 4mm (#6) screws 57 58 2.28 45 2.24 1.78 45 35 1.78 1.38 == 50 5 5 1.97 0.20 0.20 57 2.24 21 0.83 110 4.33 45 1.78 120 4.72 57 2.24 27 1.06 dz5 me5 50 1.97 53 2.09 45 1.78 58 2.28 8.65 0.34 === 10x?1.3 a1 a2 1.34 38 34 1.50 27 1.06 57 34 2.24 1.34 la2 kt 58 2.28 6 0.24 25 0.99 22 0.87 57 2.24 22 0.87 58 2.26 inches mm dimensions
tesys? k-line mini-contactors and starters dimensions and mounting of type lck and lpk reversing contactors ? 2001-2004 schneider electric all rights reserved 58 01/04 dimensions and mounting of type lc k k and lp k k reversing contactors reversing contactors lc2k, lc8k, lp2k on panel on mounting rail am1dp200 or am1de200 1.4 (35 mm) din rail on one asymmetrical rail dz5mb with 2 clip-on mounting plates la9d973 or on 2 mounting plates dx1ap25 . 2 x la9d973 2 x dx1ap25 on printed circuit board for reversing contactors or 2 contactors mounted side by side electronic time delay auxiliary contact blocks la2kt on reversing contactors suppressor modules la4k ? on reversing contactors 57 2.24 31 1.22 la1k 58 2.28 50 1.97 == 90 3.54 80 3.15 4 mm (#6) screws = = 57 58 2.28 90 2.24 3.54 90 35 == 50 5 5 1.97 0.20 0.20 57 21 3.54 1.38 2.24 0.83 57 27 2.24 1.06 dz5 me5 90 3.54 110 120 4.33 4.72 45 1.78 45 58 8.65 === 20x?1.3 a1 a2 50 45 8.65 1.78 0.34 1.78 0.34 = = = 53 2.28 1.97 2.09 a1 a2 1.34 38 34 1.50 27 1.06 57 34 2.24 1.34 la2 kt 58 2.28 6 25 0.99 22 0.24 0.87 57 22 2.24 .87 58 2.28 inches mm dimensions
tesys? k-line mini-contactors and starters schematics 59 01/04 ? 2001-2004 schneider electric all rights reserved schematics type lck and lpk contactors and accessories 3-pole contactors lc1k, lc7k, lp1k integrated-coil suppression device lc7k 3-pole + n.o. 3-pole + n.c. 4-pole contactors lc1k, lc7k, lp1k integrated-coil suppression device lc7k 4-pole 2-pole n.o. + 2-pole n.c. instantaneous auxiliary contacts la1k for contactors lc ? k and lp ? k 2 n.o. la1kn20 la1kn207 2 n.c. la1kn02 la1kn027 1 n.o. + 1 n.c. la1kn11 la1kn117 4 n.o. la1kn40 la1kn407 3 n.o. + 1 n.c. la1kn31 la1kn317 2 n.o. + 2 n.c. la1kn22 la1kn227 1 n.o. + 3 n.c. la1kn13 la1kn137 4 n.c. la1kn04 la1kn047 terminal referenci ng conforming to standard en 50012 for 3-pole contactors 2 n.c. la1kn02m 1 n.o. + 1 n.c. la1kn11m 3 n.o. + 1 n.c. la1kn31m 2 n.o. + 2 n.c. la1kn22m 1 n.o. + 3 n.c. la1kn13m for 4-pole contactors 1 n.o. + 1 n.c. la1kn11p 2 n.o. + 2 n.c. la1kn22p electronic time delay auxiliary contact blocks la2kt for contactors lc ? k and lp ? k 1 c/o suppressor modules la4kc la4ke a1 a 2 13/no 14 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 22 21/nc a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 a 1 a 2 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 7/l4 t4/8 r1 r2 a1 a2 1 2 3 4 r3 r4 53/no 54 63/no 64 61/nc 62 51/nc 52 61/nc 62 53/no 54 54 64 74 53/n o 63/n o 73/n o 83/n o 84 53/no 54 61/nc 62 73/no 74 83/no 84 53/no 54 61/nc 62 71/nc 72 83/no 84 54 62 72 82 53/no 61/nc 71/nc 81/nc 51/nc 52 61/nc 62 71/nc 72 81/nc 82 31/nc 32 21/nc 22 22 34 21/nc 33/no 33/no 34 21/nc 22 43/no 44 53/no 54 21/nc 22 43/no 44 53/no 54 31/nc 32 21/nc 22 53/no 54 31/nc 32 41/nc 42 21/nc 22 13/no 14 22 13/no 14 21/nc 31/nc 32 43/no 44 a1 a2 18 15 16 + ? dc ac/ dc
tesys? k-line mini-contactors and starters schematics ? 2001-2004 schneider electric all rights reserved 60 01/04 type lck and lpk reversing contactors and accessories 3-pole reversing contactors lc2k, lc8k, lp2k with screw clamp terminals dashed lines indicate suggested customer wiring to electrically interlock coils integrated-coil suppression device lc8k 3 p + n.o. 3 p + n.c. with slip-on connectors or solder pins (printed circuit board) 3 p+ n.o. with slip-on connectors or solder pins (printed circuit board) 3 p + n.c. 4-pole reversing contactors lc2k, lc8k, lp2k integrated-coil suppression device lc8k with screw clamp terminals 4 p with slip-on connectors or solder pins (printed circuit board) 4 p instantaneous auxiliary contact blocks la1k for contactors lc ? k and lp2k 2 n.o. la1kn20 la1kn207 2 n.c. la1kn02 la1kn027 1 n.o. + 1 n.c. la1kn11 la1kn117 terminal referencing conforming to standard en 50012 1 n.o. + 1 n.c. la1kn11p for contactors lc ? k , lp2k 4 n.o. la1kn40 la1kn407 3 n.o. + 1 n.c. la1kn31 la1kn317 2 n.o. + 2 n.c. la1kn22 la1kn227 1 n.o. + 3 n.c. la1kn13 la1kn137 4 n.c. la1kn04 la1kn047 for auxiliary contacts with terminal referencing conforming to standard en 50012 see page 55. electronic time delay contact blocks la2kt suppressor modules la4kc la4ke for contactors lc ? k and lp ? k 1 c/o a1 a2 13/no 14 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 13/no 14 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 21/nc 22 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 21/nc 22 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 13/no 14 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 13/no 14 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 21/nc 22 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 21/nc 22 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 a1 a2 a1 a2 1 2 3 4 5 6 a1 a2 1 2 3 4 5 6 1/l1 1/l2 1/l3 2/l1 2/l2 2/l3 l1 l2 l3 7 8 1n 7 8 2n n a1 a2 1 2 3 4 5 6 a1 a2 1 2 3 4 7 8 7 8 5 6 14 13/no 22 21/nc 53/no 54 63/no 64 61/nc 62 51/nc 52 61/nc 62 53/no 54 54 64 74 53/no 63/no 73/no 83/no 84 62 74 53/no 54 61/nc 73/no 83/no 84 53/no 54 61/nc 62 71/nc 72 83/no 84 54 62 72 82 53/no 61/nc 71/nc 81/nc 51/nc 52 61/nc 62 71/nc 72 81/nc 82 + ? dc ac/ dc a1 a2 18 15 16
tesys? k-line mini-contactors and starters characteristics of type lrk overload relays 61 01/04 ? 2001-2004 schneider electric all rights reserved characteristics of type lr\bk overload relays k select short circuit protection to meet the national electrical code or other local codes and standards. environment conforming to standards meets the essential requirements of the lv & emc directives iec 60947, nf c 63-650, vde 0660, bs 4941, ul 508, csa 22.2 no. 14 product certifications e164353 nkcr lr43364 3211 03 protective treatment conforming to iec 60068 (din 50016) ?tc? (fungus-proof, tropicalization protection) degree of protection conforming to vde 0106 protection against direct finger contact ambient air temperature around the device storage -40 to +70 c (-40 to +158 f) for normal operation (iec 60947) -20 to +55 c (-4 to +131 f) without derating operating limit -30 to +60 c (-22 to +140 f) with derating c maximum operating altitude without derating 2000 m (6562 ft.) operating positions vertical axis horizontal axis without derating with derating c flame resistance conforming to ul 94 self-extinguishing material v1 conforming to nf f 16-101 and 16-102 conforming to requirement 2 shock resistance, hot state (1/2 sine wave, 11 ms) conforming to iec 60068, n.c. contact 10 gn conforming to iec 60068, n.o. contact 10 gn vibration resistance, hot state 5 to 300 hz conforming to iec 60068, n.c. contact 2 gn conforming to iec 60068, n.o. contact 2 gn safe separation of circuits conforming to vde 0106 and iec 60536 selv, up to 400 v q cabling minimum maximum maximum to iec 60947 screw clamp terminals solid or stranded cable awg 1 x 18 2 x 14 or 1 x 12 ? solid cable mm 2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5 stranded cable without cable end mm 2 1 x 0.75 2 x 4 2 x 2.5 stranded cable with cable end mm 2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5 tightening torque phillips no. 2 or 3/16" slotted head 0.8 n k m (7 lb.-in.) mounting directly under the contactor or reversing contactor connections made automatically when mounted under the contactor, as follows: - contactor terminal a2 connected to overload relay terminal 96 on all products, - contactor terminal 14 connected to overload relay terminal 95 on products with 3 p + n.o. when using 3 p + n.c., or 4 p contactors, or the n.o. au xiliary contact marked 13-14, at a voltage other than the coil voltage, break off the link marked 14. (see page 64 for additional information.) c please consult your local field sales office. q safe extra low voltage. auxiliary contact characteristics number of contacts 1 n.c. + 1 n.o. conventional thermal current a 6 short-circuit protection k conforming to iec 60947, vde 0660. gl fuse or supplementary protector gb2cb ?? a 6 max. maximum power of the controlled contactor coils (sealed) (occasional operating cycles of contact 95-96) ac v 24 48 110 220/ 230 400 415/ 440 600/ 690 va 100 200 400 600 600 600 600 dc v 24 48 110 220 250 ? ? w 100 100 50 45 35 ? ? maximum operational voltage ac, category ac-15 v 690 dc, category dc-13 v 250 90 90 90 90
tesys? k-line mini-contactors and starters characteristics of type lrk overload relays ? 2001-2004 schneider electric all rights reserved 62 01/04 electrical characteristi cs of the power circuit rated operational voltage (ve) up to v 690 rated insulation voltage (vi) conforming to bs 4941 v 690 conforming to iec 60947 v 690 conforming to vde 0110 group c v 750 conforming to ul 508, csa 22.2 no. 14 v 600 rated impulse withstand voltage (vimp) kv 6 frequency limits of th e operational current hz up to 400 power dissipated per pole w 2 short-circuit protec tion and coordination by circuit breaker select in accordance with nec and local codes by fuses maximum 400% of motor fla operating characteristics sensitivity to phase failure conforming to iec 60947 yes reset manual or automatic selected by means of a lockable and sealable switch on the front of the relay signalling on front of relay trip indicator reset-stop function pressing the reset-stop button: ? actuates the n.c. contact ? has no effect on the n.o. contact test function by pushbutton pressing the test button enables: ? checking of the control circuit wiring ? simulation of overload tripping (actuation of both n.c. and n.o. contacts, and of the trip indicator) tripping curves average operating time related to multiples of the current setting class 10 a time class 10 a time class 10 a x setting current (ir) x setting current (ir) balanced 3-phase operation, from cold state. balanced operation with 2-phases only, from cold state. 1 = setting: at lower end of scale. 2 = setting: at upper end of scale. 2 h 1h 20 min 1 h 40 min 20 min 10 min 6 min 4 min 2 min 1 min 40 s 20 s 10 s 6 s 4 s 2 s 1 s 1 1.2 1.5 2 3 4 5 6 8 10 15 2 h 1h 20 min 1 h 40 min 20 min 10 min 6 min 4 min 2 min 1 min 40 s 20 s 10 s 6 s 4 s 2 s 1s 1 1.2 1.5 2 3 4 5 6 8 10 15 1 2
tesys? k-line mini-contactors and starters selection of type lrk overload relays 63 01/04 ? 2001-2004 schneider electric all rights reserved selection of type lr\bk overload relays these overload relays are designed for the protection of motors. they are ambient-compensated and phase-failure sensitive. they may be re set either manually or automatically. for direct mounting, the relays are placed under the contactors with screw clamp terminals only (pre-wired terminals; see page 64). for separate mounting, use terminal block la7k0064 (see below). the front face of the overload relay provides:  selection of reset mode: manual (marked h) or automatic (marked a).  a red pushbutton for the trip test function.  a blue pushbutton for stop and manual reset.  a yellow trip flag to indicate that the overload relay tripped. three-pole overload relays with screw clamp terminals short-circuit protection for north american applications by circuit breaker select in accordance with nec and local codes by fuses maximum 400% of motor fla relay setting range european type fuses maximum rating type catalog number weight lb. (kg) am gl bs88 aaaa class 10 (the standard specifies a tripping time of between 2 and 10 seconds at 7.2 in) 0.11 to 0.16 0.25 0.5 ? lr2k0301 0.32 (0.145) 0.16 to 0.23 0.25 0.5 ? lr2k0302 0.32 (0.145) 0.23 to 0.36 0.5 1 ? lr2k0303 0.32 (0.145) 0.36 to 0.54 1 1.6 ? lr2k0304 0.32 (0.145) 0.54 to 0.8 1 2 ? lr2k0305 0.32 (0.145) 0.8 to 1.2 2 4 6 lr2k0306 0.32 (0.145) 1.2 to 1.8 2 6 6 lr2k0307 0.32 (0.145) 1.8 to 2.6 4 8 10 lr2k0308 0.32 (0.145) 2.6 to 3.7 4 10 16 lr2k0310 0.32 (0.145) 3.7 to 5.5 6 16 16 lr2k0312 0.32 (0.145) 5.5 to 8 8 20 20 lr2k0314 0.32 (0.145) 8 to 11.5 10 25 20 lr2k0316 0.32 (0.145) 10 to 14 16 32 25 lr2k0321 f 0.32 (0.145) 12 to 16 20 40 32 lr2k0322 f 0.32 (0.145) f not ul listed or csa certified. overload relays without single-phase sensitivity f class 10: to order, replace the prefix lr2 by lr7 in the catalog numbers selected from above (only applicable to overload relays lr2k0305 to lr2k0322). example: lr7k0308 . f not ul listed or csa certified. accessory description type of connection catalog number weight lb. (kg) terminal block for separate clip-on mounting of the overload relay on 35 mm din rail screw clamp la7k0064 0.22 (0.100) lr2k0301 la7k0064
tesys? k-line mini-contactors and starters dimensions, mounting, and schematics for type lrk overload relays ? 2001-2004 schneider electric all rights reserved 64 01/04 dimensions, mounting, and schematics for type lr\bk overload relays protection components lr2k direct mounting beneath the contactor separate mounting with terminal block la7k0064 on 1.4 in. (35 mm) din rail ( am1dp200 or am1de200 ) am1- c dp200 3.09 in. / 78.5mm de200 3.38 in. / 86mm lr2k lr2k + lc ? k built-in wiring schematic lr2k overload relays feature built-in wiring to save time and materials when all five links of the overl oad relay are connected to a k-line contactor with an integrated n.o. (normally-open) aux iliary contact. terminal 96 of the n.c. (normally-cl osed) overload relay contact (95-96) will be internally linked in series with terminal a2 of the contactor operating coil. terminal 95 of the n.c. overload relay contact (95-96) will be internally linked in series with te rminal 14 of n.o. coil holding contact (13-14) of the contactor. these inter nal links help to el iminate additional wiring when using a conventional 3-wire control circuit similar to the diagram shown. if integrated wiring between contactor and overload relay is not desired, break off the two links on the overload relay as indicated. 65 8 == 35 = = 4mm (#6) screws 45 2.56 0.31 1.38 1.77 58 50 116 2.28 1.97 4.57 38 80 1.50 3.15 2.95 1.77 75 c 45 1 3 5 2 4 6 97 98 95 96 a h reset/stop internal links 1 3 5 13 a1 2 4 6 14 a2 2 4 6 97 95 98 96 ? km1 a2 a1 96 95 13 14 ? km1 o 95 96 stop start l1 13 14 95 96 a2 a1 l2 internal links
tesys? k-line mini-contactors and starters characteristics of type lpk low-consumption contactors 65 01/04 ? 2001-2004 schneider electric all rights reserved characteristics of type lp\bk low-consumption contactors q safe extra low voltage. environment rated insulation voltage (vi) conforming to iec 60947 v 690 conforming to vde 0110 gr c v 750 conforming to bs 5424, nf c 20-040 v 690 conforming to csa 22.2 no. 14, ul 508 v 600 rated impulse withstand voltage (vimp) kv 8 conforming to standards meets the essential requirements of the lv & emc directives iec 60947, nf c 63-110, vde 0660, bs 5424, ul 508, csa 22.2 no. 14 approvals lp ? k06, lp ? k09, lp ? k12 e164862 nldx (screw clamp) lr43364 3211 04 e164862 nldx2 (slip-on & solder pin) protective treatment conforming to iec 60068 (din 50016) ?tc? (fungus-proof, tropicalization protection) degree of protection conforming to vde 0106 protection against direct finger contact ambient air temperature around the device storage - 50 to + 80 c (-58 to +176 f) operation - 25 to + 50 c (-13 to +122 f) maximum operating altitude without derating 2000 m (6562 ft) operating positions vertical axis horizontal axis without derating without derating derate current carrying capability by 15% when not mounted vertically flame resistance conforming to ul 94 self-extinguishing materials v1 conforming to nf f 16-101 and 16-102 conforming to requirement 2 shock resistance (1/2 sine wave, 11 ms) contactor open 10 g contactor closed 15 g vibration resistance 5 to 300 hz contactor open 2 g contactor closed 4 g safe separation of circuits conforming to vde 0106 and iec 60536 selv, up to 400 v q cabling min max max to iec 60947 screw clamp terminals solid or stranded cable awg 1 x 18 2 x 14 or 1 x 12 - solid cable mm 2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5 stranded cable without cable end mm 2 1 x 0.75 2 x 4 2 x 2.5 stranded cable with cable end mm 2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5 slip-on connectors clip 2 x 2.8mm or 1 x 6.35mm (2 x 0.110 in. or 1 x 0.250 in.) solder pins for printed circuit board with locating device between power and control circuits 4 mm x 35 microns tightening torque phillips no. 2 or 3/16" slotted head screwdriver 0.8 to 1.3 nm (7 to 11.5 lb.-in) terminal referencing conforming to standards en 50005 and en 50012 up to 3 contacts 90 90 1 8 0 90 90
tesys? k-line mini-contactors and starters characteristics of type lpk low-consumption contactors ? 2001-2004 schneider electric all rights reserved 66 01/04 pole characteristics conventional rated thermal current (ith) for ambient temperature 50 c (122f) a20 rated operational frequency hz 50/60 frequency limits of the operational current hz up to 400 rated operational voltage (ve) v 690 rated making capacity i rms conforming to nf c 63-110 and iec 60947 a lp ? k06, lp ? k09 lp ? k12 110 144 rated breaki ng capacity conforming to nf c 63-110 and iec 60947 v 220/ 230 380/ 400 415 440 500 660/ 690 lp ? k06, lp ? k09 lp ? k12 i rms a 110 ? 110 ? 110 ? 110 120 80 80 70 70 permissible short time rating open mounted, for a time ?t? from cold state ( 50 c [122 f]) 1 s 5 s 10 s 30 s 1 min 3 min 15 min lp ? k06, lp ? k09 lp ? k12 a 90 115 85 105 80 100 60 75 45 55 40 50 20 25 short-circuit protection by circuit breaker select in accordance with nec and local codes by fuses max 400% of motor fla average impedance per pole at ith and 50 hz m ? 3 utilization in category ac-1 resistive circuits, heating, lighting (ve 440 v) maximum rated operational current for a temperature 50 c (122 f) a20 rated operational current limits in relation to on-load factor and operating frequency a on-load factor 90% 60% 30% 300 op. cycles/hour 13 15 18 120 op. cycles/hour 15 18 19 30 op. cycles/hour 19 20 20 increase in operational current by paralleling poles apply the following coefficients to the current values given above. these take into account the often unbalanced current distribution between poles 2 poles in parallel: k = 1.60 3 poles in parallel: k = 2.25 4 poles in parallel: k = 2.80 utilization in category ac-3 squirrel cage motors operational power according to the voltage voltage 50 or 60hz v 115 220 220/ 240 380/ 415 440/ 480 500/ 600 660/ 690 1-ph 1-ph 3-ph 3-ph 3-ph 3-ph 3-ph lp ? k06 motor ratings kw 0.37 0.75 1.5 2.2 3 3 3 lp ? k09 motor ratings kw 0.55 1.1 2.2 4 4 4 4 lp ? k12 motor ratings kw??35.5 5.5 4 (480) 44 percent utilization of operational power in relation to the maximum operating rate op. cycles/h 600 900 1200 power 100% 75% 50% utilization in category ac-3 squirrel cage motors operational power according to the voltage voltage 50 or 60hz v 115 220 200/ 208 220/ 240 460/ 480 575/ 600 1-ph 1-ph 3-ph 3-ph 3-ph 3-ph lc ? k06, lp ? k06 motor ratings hp 0.5 1 1.5 1.5 3 3 lc ? k09, lp ? k09 motor ratings hp0.51.52355 lc ? k12, lp ? k12 motor ratings hp12337.510 lc ? k16, lp ? k16 not for north american applications. not ul listed or csa certified.
tesys? k-line mini-contactors and starters characteristics of type lpk low-consumption contactors 67 01/04 ? 2001-2004 schneider electric all rights reserved control circuit characteristics type lp4 lp5 rated control circuit voltage (vc) v dc 12 to 72 control voltage limits ( 50 c [122 f]) single-voltage coil for operation 0.7 to 1.30 vc for drop-out 0.10 vc average consumption at 20 c (68 f) and at vc inrush w 1.8 sealed w 1.8 heat dissipation w1.8 operating time at 20 c (68 f) and at vc between coil energization and: - opening of the n.c. contacts - closing of the n.o. contacts ms ms 25 to 35 30 to 40 between coil de-energization and: - opening of the n.o. contacts - closing of the n.c. contacts ms ms 10 to 20 15 to 25 maximum immunity to micro breaks ms 2 maximum operating rate in operating cycles per hour 3600 mechanical durability at vc in millions of operating cycles wide range dc coil 30 5 auxiliary contact characteri stics of contactors and instantaneous contact blocks number of contacts on lp4, lp5k 1 on la1k 2 max. rated operational voltage (ve) up to v 690 rated insulation voltage (vi) conforming to bs 5424 v 690 conforming to iec 60947 v 690 conforming to vde 0110 group c v 750 conforming to csa 22.2 no. 14, ul 508 v 600 conventional rated thermal current (lth) for ambient temperature 50 c (122 f) a 10 frequency of operational current hz up to 400 minimum switching capacity v min (din 19 240) v 17 (reliability <10 -8 at 24v) i min ma 5 short-circuit protection conforming to iec 60947 and vde 0660, gl fuse a 10 rated making capacity conforming to iec 60947 i rms a 110 overload current permissible for 1 s a 80 500 ms a 90 100 ms a 110 insulation resistance m ? > 10 non-overlap distance linked contacts conforming to inrs and bia specs. mm 0.5 (0.02") operational powe r of contacts conforming to iec 60947 ac supply, category ac-15 dc supply, category dc-13 electrical durability (valid up to 3600 operating cycles per hour) on an inductive load such as the coil of an electromagnet: making current (power factor 0.7) = 10 times the breaking current (power factor 0.4). electrical durability (valid up to 1200 operating cycles per hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. v2448 110/ 127 220/ 230 380/ 400 400 600/ 690 v 24 48 110 220 440 600 1 million operating cycles va 48 96 240 440 800 880 1200 w 120 80 60 52 51 50 3 million operating cycles va 17 34 86 158 288 317 500 w 55 38 30 28 26 25 10 million operating cycles va 7 14 36 66 120 132 200 w 15119876 occasional ma king capacity va 1000 2050 5000 10000 14000 13000 9000 w 720 600 400 300 230 200 1 breaking limit of contacts valid for maximum of 50 operating cycles at 10 s intervals (breaking current = making current x power factor 0.7). 2 electrical durability of contacts for: - 1 million operating cycles (2a) - 3 million operating cycles (2b) -10 million operating cycles (2c). 3 breaking limit of contacts valid for maximum of 20 operating cycles at 10 s intervals with current passing for 0.5 s per operating cycle. 4 thermal limit. power in broken va power in broken w 10 000 5000 3000 2000 1000 800 600 500 400 300 200 100 80 60 24 48 110 220 440 690 v 120 380 500 40 16 000 8000 6000 4000 2c 2b 4 1 2a 1000 700 500 300 200 100 80 60 50 40 30 20 10 8 6 12 24 48 110 220 440 600 v 250 200 140 100 50 20 2c 2b 2a 3 4 time constant in ms
tesys? k-line mini-contactors and starters selection of low-consumption contactors for motor control ? 2001-2004 schneider electric all rights reserved 68 01/04 selection of low-consumption contactors for motor control the table below shows three-pole contactors with low-consumption coils for dc control circuits. they are compatible with programmable controller output s, and incorporate an led indicator. for wide-range coils (0.7 to 1.3 vc), a suppressor (zener dio de) is fitted as standard (consumption is 1.8 w). the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready -to-tighten? position. for information on add-on auxiliary contact blocks and accessories, see page 72. three-pole contactors with low-consumption coils for dc control circuits horsepower ratings for north american applicatio ns kilowatt ratings for in ternational applications type of connection auxiliary contacts catalog number f p weight lb. (kg) maximum horsepower rating category ac-3, 50/60 hz max. inductive current standard power ratings of 3-phase motors, 50/60 hz in category ac-3 rated operational current, up to 440 v 1-phase 3-phase 220 v 230 v 380 v 415 v 440/500 v 660/690 v 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575/ 600 v hp hp hp hp hp hp a kw kw kw a n.o. n.c. 0.5 1 1.5 1.5 3 3 6 1.5 2.2 3 6 screw clamp 1? lp4k0610 ??? 0.52 (0.235) ?1 lp4k0601 ??? 0.52 (0.235) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lp4k06107 ??? 0.52 (0.235) ?1 lp4k06017 ??? 0.52 (0.235) solder pins for printed circuit board 1? lp4k06105 ??? 0.265 (0.58) ?1 lp4k06015 ??? 0.58 (0.265) spring terminals 1? lp4k06103 ??? 0.52 (0.235) ?1 lp4k06013 ??? 0.52 (0.235) 0.51.523559 2.2 4 4 9 screw clamp 1? lp4k0910 ??? 0.52 (0.235) ?1 lp4k0901 ??? 0.52 (0.235) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lp4k09107 ??? 0.52 (0.235) ?1 lp4k09017 ??? 0.52 (0.235) solder pins for printed circuit board 1? lp4k09105 ??? 0.58 (0.265) ?1 lp4k09015 ??? 0.58 (0.265) spring terminals 1? lp4k09103 ??? 0.52 (0.235) ?1 lp4k09013 ??? 0.52 (0.235) 12337.51012 3 5.5 4 (> 440) 5.5 (440) 12 screw clamp 1? lp4k1210 ??? 0.52 (0.235) ?1 lp4k1201 ??? 0.52 (0.235) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lp4k12107 ??? 0.52 (0.235) ?1 lp4k12017 ??? 0.52 (0.235) solder pins for printed circuit board 1? lp4k12105 ??? 0.58 (0.265) ?1 lp4k12015 ??? 0.58 (0.265) spring terminals 1? lp4k12103 ??? 0.52 (0.235) ?1 lp4k12013 ??? 0.52 (0.235) f standard control circuit voltages (variable delivery times, please consult your local square d field sales office). p use voltage codes on page 52 ?voltage code table? to complete catalog number. lp4k06105 ???
tesys? k-line mini-contactors and starters selection of low-consumption reversing contactors for motor control 69 01/04 ? 2001-2004 schneider electric all rights reserved selection of low-consumption reversing contactors for motor control the table below shows three-pole reversing contac tors with low-consumption coils for dc control circuits. they are compatible with programmable controller outputs, and incorporate an led indicator and mechanical interlock. for wide-range coils (0.7 to 1.3 vc), a suppressor (zener diode) is fitted as standard (consumption is 1.8 w). the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready-to-tighten? positi on. customer wiring is required to connect coil terminations to the electrical interlock; see page 75 for more information. for information on add-on auxiliary contact blocks and accessories, see page 72. three-pole reversing contactors with low-consumption coils for dc control circuits horsepower ratings for north american applicati ons kilowatt ratings for in ternational applications type of connection auxiliary contacts catalog number f p weight lb. (kg) maximum horsepower rating category ac-3, 50/60 hz max. inductive current standard power ra tings of 3-phase motors, 50/60 hz in category ac-3 rated operational current, up to 440 v 1-phase 3-phase 220 v 230 v 380 v 415 v 440/500 v 660/690 v 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575/ 600 v hp hp hp hp hp hp a kw kw kw a n.o. n.c. 0.5 1 1.5 1.5 3 3 6 1.5 2.2 3 6 screw clamp q 1? lp5k0610 ??? 1.08 (0.490) ?1 lp5k0601 ??? 1.08 (0.490) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lp5k06107 ??? 1.03 (0.470) ?1 lp5k06017 ??? 1.03 (0.470) solder pins for printed circuit board 1? lp5k06105 ??? 1.17 (0.530) ?1 lp5k06015 ??? 1.17 (0.530) spring terminals 1? lp5k06103 ??? 1.08 (0.490) ?1 lp5k06013 ??? 1.08 (0.490) 0.51.523559 2.2 4 4 9 screw clamp q 1? lp5k0910 ??? 1.08 (0.490) ?1 lp5k0901 ??? 1.08 (0.490) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lp5k09107 ??? 1.03 (0.470) ?1 lp5k09017 ??? 1.03 (0.470) solder pins for printed circuit board 1? lp5k09105 ??? 1.17 (0.530) ?1 lp5k09015 ??? 1.17 (0.530) spring terminals 1? lp5k09103 ??? 1.08 (0.490) ?1 lp5k09013 ??? 1.08 (0.490) 12337.51012 3 5.5 4 (> 440) 5.5 (440) 12 screw clamp q 1? lp5k1210 ??? 1.08 (0.490) ?1 lp5k1201 ??? 1.08 (0.490) slip-on 1 x 0.25 in., or 2 x 0.11 in. 1? lp5k12107 ??? 1.03 (0.470) ?1 lp5k12017 ??? 1.03 (0.470) solder pins for printed circuit board 1? lp5k12105 ??? 1.17 (0.530) ?1 lp5k12015 ??? 1.17 (0.530) spring terminals 1? lp5k12103 ??? 1.08 (0.490) ?1 lp5k12013 ??? 1.08 (0.490) f standard control circuit voltages (variable delivery times, please consult your local square d field sales office.). q pre-wired power circuit connections are standard on screw clamp versions. p use voltage codes on page 52 ?voltage code table? to complete catalog number. lp5k06105 ???
tesys? k-line mini-contactors and starters selection of low-consumption contactors for resistive loads ? 2001-2004 schneider electric all rights reserved 70 01/04 selection of low-consumption contactors for resistive loads three- and four-pole contactors with low-consumption coils for dc control circuits the table below shows three- and four-pole contac tors with low-consumption coils for dc control circuits. they are compatible with programmable cont roller outputs, and incorporate an led indicator. for wide-range coils (0.7 to 1.3 vc), a suppressor (zener diode) is fitt ed as standard (consumption is 1.8 w). the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready-to-ti ghten? position. for information on add-on auxiliary contact blocks and accessories, see page 72. non-inductive loads category ac-1 maximum current at 50 c (122 f) type of connection power poles auxiliary contacts catalog number f p weight lb. (kg) a n.o. n.c. n.o. n.c. 20 screw clamp 3? 1? lp4k0910 ??? 0.52 (0.235) ?1 lp4k0901 ??? 0.52 (0.235) 4?? ? lp4k09004 ??? 0.52 (0.235) 22? ? lp4k09008 ??? 0.52 (0.235) slip-on 1 x 0.25 in. or 2 x 0.11 in. 3? 1? lp4k09107 ??? 0.52 (0.235) ?1 lp4k09017 ??? 0.52 (0.235) 4?? ? lp4k090047 ??? 0.52 (0.235) 22? ? lp4k090087 ??? 0.52 (0.235) solder pins for printed circuit board 3? 1? lp4k09105 ??? 0.58 (0.265) ?1 lp4k09015 ??? 0.58 (0.265) 4?? ? lp4k090045 ??? 0.58 (0.265) 22? ? lp4k090085 ??? 0.58 (0.265) spring terminals 3? 1? lp4k09103 ??? 0.52 (0.235) ?1 lp4k09013 ??? 0.52 (0.235) 4?? ? lp4k090043 ??? 0.52 (0.235) 2?? ? lp4k090083 ??? 0.52 (0.235) f standard control circuit voltages (variable delivery times, please consult your local square d field sales office.). p use voltage codes on page 52 ?voltage code table? to complete catalog number. lp4k090047 ??
tesys? k-line mini-contactors and starters selection of low-consumption contactors for resistive loads 71 01/04 ? 2001-2004 schneider electric all rights reserved three- and four-pole contactors with low-c onsumption coils for dc control circuits the table below shows three-pole reversing and fou r-pole change over contactors with low-consumption coils for dc control circuits. they are compatible wi th programmable controller outputs, and incorporate an led indicator and mechanical interlock. for wide-range coils (0.7 to 1.3 vc), a suppressor (zener diode) is fitted as standard (consumption is 1.8 w). the contactors mount on 35 mm din rails or with 4 mm (# 6) screws. the wire termination screws are in the open, ?ready-to-tighten? positi on. customer wiring is required to connect coil terminations to the electrical interlock; see page 75 for more information. for information on add-on auxiliary contact blocks and accessories, see page 72. non-inductive loads category ac-1 maximum current at 50 c (122 f) type of connection power poles auxiliary contacts catalog number f p weight lb. (kg) a n.o. n.c. n.o. n.c. 20 screw clamp 3?1 ? lp5k0910 ??? c 1.08 (0.490) 3?? 1 lp5k0901 ??? c 1.08 (0.490) 4?? ? lp5k09004 ??? 1.08 (0.490) slip-on 1 x 0.25 in. or 2 x 0.11 in. 3?1 ? lp5k09107 ??? 1.03 (0.470) 3?? 1 lp5k09017 ??? 1.03 (0.470) 4?? ? lp5k090047 ??? 1.17 (0.530) solder pins for printed circuit board 3?1 ? lp5k09105 ??? 1.17 (0.530) 3?? 1 lp5k09015 ??? 1.17 (0.530) 4?? ? lp5k090045 ??? 1.17 (0.530) spring terminals 3?1 ? lp5k09103 ??? 1.08 (0.490) 3?? 1 lp5k09013 ??? 1.08 (0.490) 4?? ? lp5k090043 ??? 1.08 (0.490) f standard control circuit voltages (variable delivery times, please consult your local square d field sales office.). c warning: these reversing contactors are pre-wired for reverse motor operation p use voltage codes on page 52 ?voltage code table? to complete catalog number. lp5k0910 ???
tesys? k-line mini-contactors and starters selection of auxiliary contacts and accessories for low-consumption contactors ? 2001-2004 schneider electric all rights reserved 72 01/04 selection of auxiliary contacts and accessories for low-consumption contactors instantaneous auxiliary contact blocks (clip-on front mounting, 1 block per contactor) type of connection type of contactor auxiliary contacts catalog number weight lb. (kg) n.o. n.c. screw clamp 3- or 4-pole 2? la1kn20 0.10 (0.045) ?2 la1kn02 0.10 (0.045) 11 la1kn11 0.10 (0.045) slip-on 1 x 0.25 in. or 2 x 0.11 in. 3- or 4-pole 2? la1kn207 0.10 (0.045) ?2 la1kn027 0.10 (0.045) 11 la1kn117 0.10 (0.045) spring terminals 3- or 4-pole 2? la1kn203 0.10 (0.045) ?2 la1kn023 0.10 (0.045) 11 la1kn113 0.10 (0.045) with terminal referencing conforming to en 50012 screw clamp k 3-pole, 6 and 9 a ?2 la1kn02m 0.10 (0.045) 11 la1kn11m 0.10 (0.045) 4-pole, 9 a 1 1 la1kn11p 0.10 (0.045) k see pages 75 and 76 for actual markings. electronic time-delay au xiliary contact blocks ? relay output, with common point changeover contact, ac or dc 240 v, 2 a maximum. ? control voltage: 0.85 to 1.1 vc. ? maximum switching capacity: 250 va or 150 w. ? operating temperature: -10 to + 60 c (14 to 140 f). ? reset time: 1.5 s during the time-delay period, 0.5 s after the time delay period. clip-on front mounting, 1 block per contactor voltage type timing range auxiliary contacts catalog number weight lb. (kg) v s spdt ac or dc 24 to 48 (1) on-delay 1 to 30 1 la2kt2e 0.09 (0.040) mounting and marking accessories description application sold in lots of unit catalog no. weight lb. (kg) mounting plates (order 1 for a contactor; order 2 for a reversing contactor) for mounting on 1 rail clip-on 1 la9d973 0.05 (0.025) for mounting on 2 rails 110/120 mm mounting centers 10 dx1ap25 0.14 (0.065) marker holder clip-on on to front of contactor 100 la9d90 0.002 (0.001) clip-in markers 4 maximum per contactor strips of 10 identical numbers 0 to 9 q 25 ab1r ? q 0.004 (0.002) strips of 10 identical capital letters a to z q 25 ab1g ? q 0.004 (0.002) 35mm " din rail (7.5 mm deep x 2 m long) 10 am1dp200 2.88 (1.310) 35mm " din rail (15 mm deep x 2 m long) 10 am1ed200 1.44 (0.650) q complete the catalog number by replacing the ? with the required number or character. cabling accessories description application sold in lots of unit catalog no. weight lb. (kg) paralleling links for 2-poles with screw clamp terminals 4 la9e01 0.02 (0.010) for 4-poles with screw clamp terminals 2 la9e02 0.03 (0.015) set of 6 power connections for 3-pole reversing contactors for motor control for contactors with screw clamp terminals 100 la9k0969 0.02 (0.010) set of 4 power connections for 4-pole changeover contactor pairs for contactors with screw clamp terminals 100 la9k0970 0.02 (0.010) (1) low consumption k-line contactors are dc only. la1kn ?? la2kt2 ? dx1ap25 la9e01
tesys? k-line mini-contactors and starters dimensions and mounting of low-consumption contactors 73 01/04 ? 2001-2004 schneider electric all rights reserved dimensions and mounting of low-consumption contactorsxxxxx contactors lp4k on panel on mounting rail am1dp200 or am1de200 1.4 in. (35 mm) din rail on one asymmetrical rail dz5mb with clip-on mounting plate la9d973 dx1ap25 on printed circuit board electronic time-delay auxiliary contact blocks la2kt on contactor 57 31 2.24 1.22 la1 k 58 2.28 50 1.97 == 35 1.38 45 1.78 = = 4mm (#6) screws 57 58 2.28 45 2.24 1.78 45 35 1.78 1.38 == 50 5 5 1.97 0.20 0.20 57 2.24 21 0.83 110 4.33 45 1.78 120 4.72 57 2.24 27 1.06 dz5 me5 50 1.97 53 2.09 45 1.78 58 2.28 8.65 0.34 === 10x?1.3 a1 a2 1.34 38 34 1.50 27 1.06 57 34 2.24 1.34 la2 kt 58 2.28 inches mm dimensions
tesys? k-line mini-contactors and starters dimensions and mounting of low-consumption reversing contactors ? 2001-2004 schneider electric all rights reserved 74 01/04 reversing contactors lp5k on panel on mounting rail am1dp200 or am1de200 1.4 in. (35 mm) din rail on one asymmetrical rail dz5mb with 2 clip-on mounting plates la9d973 or on 2 mounting plates dx1ap25 . 2 x la9d973 2 x dx1ap25 on printed circuit board for reversing contactors or 2 contactors mounted side by side electronic time-delay auxiliary contact blocks la2kt on reversing contactors 57 2.24 31 1.22 la1k 58 2.28 50 1.97 == 90 3.54 80 3.15 4 mm (#6) screws = = 57 58 2.28 90 2.24 3.54 90 35 == 50 5 5 1.97 0.20 0.20 57 21 3.54 1.38 2.24 0.83 57 27 2.24 1.06 dz5 me5 90 3.54 110 120 4.33 4.72 45 1.78 45 58 8.65 === 20x?1.3 a1 a2 50 45 8.65 1.78 0.34 1.78 0.34 = = = 53 2.28 1.97 2.09 a1 a2 1.34 38 34 1.50 27 1.06 57 34 2.24 1.34 la2 kt 58 2.28 inches mm dimensions
tesys? k-line mini-contactors and starters type lpk schematics 75 01/04 ? 2001-2004 schneider electric all rights reserved type lp\bk schematics type lpk three-pole low-consumption contact ors, reversing contactors, and accessories 3-pole contactors lp4k integrated-coil suppression device lp4k 3-pole + n.o. 3-pole + n.c. 3-pole reversing contactors lp5k with screw clamp terminals dashed lines indicate suggested customer wiring to electrically interlock coils integrated-coil suppression device lc5k 3-pole + n.o. 3-pole + n.c. with slip-on connectors or solder pins for printed circuit boards 3-pole + n.o. 3-pole + n.o. instantaneous auxiliary contact blocks la1k for 3-pole contactors terminal referencing conforming to standard en 50012 2 n.o. la1kn20 la1kn207 2 n.c. la1kn02 la1kn027 1 n.o. + 1 n.c. la1kn11 la1kn117 2 n.c. la1kn02 1 n.o. + 1 n.c. la1kn11m electronic time-delay auxiliary contact blocks la2kt for 3-pole contactors lp ? k 1 c/o 13/no 14 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 22 21/nc a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 -a2 +a1 13/no 14 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 13/no 14 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 21/nc 22 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 21/nc 22 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 -a2 +a1 13/no 14 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 13/no 14 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 21/nc 22 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 21/nc 22 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 53/no 54 63/no 64 61/nc 62 51/nc 52 61/nc 62 53/no 54 22 21/nc 32 31/nc 22 21/nc 34 33/no a1 a2 18 15 16
tesys? k-line mini-contactors and starters type lpk schematics ? 2001-2004 schneider electric all rights reserved 76 01/04 type lpk four-pole low-consumption contac tors, reversing contactors, and accessories 4-pole contactors lp4k integrated-coil suppression device lp4k 4-pole + n.o. 2-pole n.o. + 2-pole n.c. 4-pole reversing contactors lp5k integrated-coil suppression device lp5k with screw clamp terminals with slip-on terminals or solder pins for printed circuits boards instantaneous auxiliary contact blocks la1k 2 n.o. la1kn20 la1kn207 2 n.c. la1kn02 la1kn027 1 n.o. + 1 n.c. la1kn11 la1kn117 terminal referencing conforming to standard en 50012 1 n.o. + 1 n.c. la1kn11p electronic time-delay auxiliary contact blocks la2kt for 3-pole contactors lp ? k 1 c/o a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 7/l4 t4/8 r1 r2 a1 a2 1 2 3 4 r3 r4 -a2 +a1 a1 a2 1 2 3 4 5 6 a1 a2 1 2 3 4 5 6 1/l1 1/l2 1/l3 2/l1 2/l2 2/l3 l1 l2 l3 7 8 1n 7 8 2n n a1 a2 1 2 3 4 5 6 a1 a2 1 2 3 4 7 8 7 8 5 6 -a2 +a1 53/no 54 63/no 64 61/nc 62 51/nc 52 61/nc 62 53/no 54 14 13/no 22 21/nc a1 a2 18 15 16
catalog 04 tesys ? d-line contactors, enclosed starters, overload relays, and accessories file 8502 contents description page general information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 contactors characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 auxiliary contacts, timers, and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 replacement coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 dimensions and mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 overload relays characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 dimensions, mounting, and schematics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 plate-mounted starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 wye-delta starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 enclosed contactors and starters horsepower rated devices for north american applications. . . . . . . . . . . . . . . . . 151 kilowatt rated devices for international applications. . . . . . . . . . . . . . . . . . . . . . . 159 contents description page general information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 contactors characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 auxiliary contacts, timers, and accessories characteristics . . . . . . . . . . . . . . . . . 100 auxiliary contacts, timers, and accessories selection . . . . . . . . . . . . . . . . . . . . . 106 d-line voltage code table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 replacement coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 dimensions and mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 overload relays characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 dimensions, mounting, and schematics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 plate-mounted starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 wye-delta starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 enclosed contactors and starters horsepower rated devices for north american applications. . . . . . . . . . . . . . . . . 151 kilowatt rated devices for international applications. . . . . . . . . . . . . . . . . . . . . . . 159 cross reference list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 d-line
? 2001-2004 schneider electric all rights reserved 78 01/04
tesys? d-line contactors and starters general information 79 01/04 ? 2001-2004 schneider electric all rights reserved general information the d-line contactors and overload relays are the lar gest selling line of contactors and starters in the world. they offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry. contactor ratings  d-line contactors and overload relays are available in 11 contactor ratings for the usa market for inductive motor applications up to 150 full-load amps and resistive loads up to 200 a. they offer motor control and overload protection for motors rated up to 100 hp at 480 vac or 125 hp at 600 vac.  3-pole and 4-pole contactor versions available.  all contactors include built-in auxiliary contacts.  all screw connections have ip20 rated touch-safe terminals with both north american and international terminal markings.  d-line contactors can be panel mo unted with screws or din rail mounted. easily installed accessories  auxiliary contact blocks with serrated wiping action  front mount dust tight auxiliary contact blocks  pneumatic time delay blocks  transient voltage surge suppressors  interface modules and electronic timers  mechanical latching blocks control circuit flexibility the d-line contactors are available with ac or dc operating coils. several devices utilize a low- consumption dc coil with built-in transient suppressi on for operation with a low-level dc signal from a computer or plc without need for an interposing relay. overload relays class 10 or class 20 bimetallic overload relays are available up to 140 a. they are bimetallic ambient compensated and are available with or without sing le-phase sensitivity for phase unbalance and phase loss protection. new solid state overload relays are ava ilable for 90 to 150 a applications. both bimetallic and solid-state overload relays include the following features:  isolated n.c. trip contact and n.o. alarm contacts.  manual or automatic reset functi on (bi-metallic versions only).  tamper-resistant window for fla settings.  test trip button.
tesys? d-line contact ors and starters characteristics of type lcd and lpd contactors ? 2001-2004 schneider electric all rights reserved 80 01/04 characteristics of type lc\bd and lp\bd contactors environment type lc1d09 lc1d12 lc1d18 lc1d25 lc1dt20 lc1dt25 lc1dt32 lc1dt40 rated insulation voltage (vi) ul/csa v 690 690 690 690 to iec 60947-4-1, overvoltage category iii, degree of pollution: 3 v 1000 1000 1000 1000 conforming to ul, csa v 600 600 600 600 rated impulse withstand voltage (vimp) conforming to iec 60947 kv6666 conforming to standards meets the essential requirements of the lv & emc directives iec 60947-1, 60947-4-1, nfc 63-110, vde 0660, bs 5424, jem 1038., en 60947-1, en 60947-4-1. approvals e164862 ccn nldx lr43364 class 3211 04 ase, ul, csa, demko, nemko, semko, fi, conforming to sncf, sichere trennung recommendations degree of protection f conforming to vde 0106 power connections protection against direct finger contact ip 2x coil connections protection against direct finger contact ip 2x protective treatment conforming to iec 60068 ?th? ambient air temperature around the device storage - 60 to + 80 c (-76 to +176 f) operation at 80 to 110% nominal control voltage - 5 to + 60 c (+23 to +140 f) permissible at nominal control voltage - 40 to + 70 c (-40 to +158 f) maximum operating altitude without derating 3000m (8900 ft.) operating positions without derating 30 possible, in relation to normal vertical mounting plane flame resistance conforming to ul 94 v 1 v1 v1 v1 conforming to iec 60695-2-1 960 960 960 960 shock resistance q 1/2 sine wave = 11ms contactor open 10 g 10 g 10 g 8 g contactor closed 15 g 15 g 15 g 15 g vibration resistance q 5 to 300 hz contactor open 2 g 2 g 2 g 2 g contactor closed 4 g 4 g 4 g 4 g pole characteristics number of poles 3 3 or 4 3 3 or 4 rated operationa l current (ie) in ac-3, 55c (131f) a 9 12 18 25 in ac-1, 40c (104f) a25253240 rated operational voltage (ve) up to v 690 690 690 690 frequency limits of the operational current hz 25 to 400 25 to 400 25 to 400 25 to 400 rated thermal current (ith) 40c (104f) a 25 25 32 40 rated making capa city (1 rms) conforming to iec 60947-4 a 250 250 300 450 rated breaking capacity (1 rms) conforming to iec 60947 220-380-415-440 v a 250 250 300 450 500 v 175 175 250 400 690 v 85 85 120 180 permissible short time rating from cold state, no current flowing for previous 15 minutes, at 40 c (104 f) for 1 s a 210 210 240 380 for 10 s a 105 105 145 240 for 1 min a 61 61 84 120 for 10 min a 30 30 40 50 short-circuit protection by circuit breaker select circuit breaker in accordance with nec and local codes by fuses maximum 400% of motor full load amps average impedance per pole a ith and 50 hz m ? 2.5 2.5 2.5 2 power dissipation per pole for the above operational currents ac-3 w 0.20 0.36 0.8 1.25 ac-1 w 1.56 1.56 2.5 3.2 f protection provided for the cable c.s.a. indicated on page 86 and for cable connections. q in the least favorable direction, without change of contact state (coil supplied at ve).
tesys? d-line contactors and starters characteristics of type lcd and lpd contactors 81 01/04 ? 2001-2004 schneider electric all rights reserved environment type lc1d32 lc1d38 lc1d40 lc1d50 lc1d65 lc1d80 lc1d95 lc1d115 lc1d150 lp1d40 lp1d50 lp1d65 lp1d80 rated insulation voltage (vi) ul/csa v 690 690 690 690 690 690 690 690 690 to iec 60947-4-1, overvoltage category iii, degree of pollution: 3 v 1000 1000 1000 1000 1000 1000 1000 1000 1000 conforming to ul, csa v 600 600 600 600 600 600 600 600 600 rated impulse withstand voltage (vimp) conforming to iec 60947 kv 6 6 8 8 8 8 8 8 8 conforming to standards meets the essential requirements of the lv & emc directives iec 60947-1, 60947-4-1, nfc 63-110, vde 0660, bs 5424, jem 1038., en 60947-1, en 60947-4-1. approvals e164862 ccn nldx lr43364 class 3211 04 ase, ul, csa, demko, nemko, semko, fi, conforming to sncf, sichere trennung recommendations - ul 508, csa c22.2 no.14 degree of protection f conforming to vde 0106 power connections protection against direct finger contact ip 2x coil connections protection against direct finger contact ip 2x except lp1d40 to lp1d80 protective treatment conforming to iec 60068 ?th? ambient air temperature around the device storage - 60 to + 80 c (-76 to +176 f) operation at 80 to 110% nominal control voltage - 5 to + 55 c (+23 to +131 f) permissible at nominal control voltage - 40 to + 70 c (-40 to +158 f) maximum operating altitude without derating 3000m (8900 ft.) operating positions without derating 30 possible, in relati on to normal vertical mounting plane flame resistance conforming to ul 94 v 1 v 1v 1v 1v 1v 1v 1v 1v 1 conforming to iec 60695-2-1 960 960 960 960 960 960 960 960 960 shock resistance q 1/2 sine wave = 11ms contactor open 8 g 8 g 8 g 8 g 8 g 8 g 8 g 6 g 6 g contactor closed 15 g 10 g 10 g 10 g 10 g 10 g 10 g 15 g 15 g vibration resistance q 5 to 300 hz contactor open 2 g 2 g 2 g 2 g 2 g 2 g 2 g 2 g 2 g contactor closed 4 g 4 g 3 g 3 g 3 g 3 g 3 g 4 g 4 g pole characteristics number of poles 3 3 3 or 4 3 3 or 4 3 or 4 3 3 or 4 3 rated operational current (ie) in ac-3, 55c (131f) a32 384050658095115150 in ac-1, 40c (104f) a 50 50 60 80 80 125 125 200 200 rated operational voltage (ve) up to v 690 690 1000 1000 1000 1000 1000 1000 1000 frequency limits of the operational current hz 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 rated thermal current (ith) 40c (104f) a 50 50 60 80 80 125 125 200 200 rated making capacity (1 rms) conforming to iec 60947-4 a 550 ? 800 900 1000 1100 ? ? ? rated breaking ca pacity (1 rms) conforming to iec 60947 220-380-415-440 v a 550 ? 800 900 1000 1100 ? ? ? 500 v 450 ? 800 900 1000 1100 ? ? ? 690 v 180 ? 400 400 630 640 ? ? ? permissible short time rating from cold state, no current flowing for previous 15 minutes, at 40 c (104 f) for 1 s a 430 430 720 810 900 990 1100 1100 1400 for 10 s a 260 310 320 400 520 640 800 950 1200 for 1 min a 138 150 165 208 260 320 400 550 580 for 10 min a 60 60 72 84 110 135 135 250 250 short-circuit protection by circuit breaker select circuit breaker in accordance with nec and local codes by fuses maximum 400% of motor full load amps average impedance per pole a ith and 50 hz m ? 2 2 1.51.51 0.80.80.60.6 power dissipation per pole for the above operational currents ac-3 w 2 2 2.4 3.7 4.2 5.1 7.2 7.9 13.5 ac-1 w 5 5 5.4 9.6 6.4 12.5 12.5 24 24 f protection provided for the cable c.s.a. indicated on page 86 and for cable connections. q in the least favorable direction, without change of contact state (coil supplied at ve).
tesys? d-line contact ors and starters characteristics of type lcd and lpd contactors ? 2001-2004 schneider electric all rights reserved 82 01/04 control circuit characteristics type lc1d09 lc1d12 lc1d18 lc1d25 lc1d32 lc1d38 lc1dt20 lc1dt25 lc1dt32 lc1dt40 rated control circuit voltage (vc) 50 or 60 hz v 21 to 660 21 to 660 control voltage limits ( 55 c [131 f]) 50 or 60 hz coils operational 0.8 to 1.1 vac 0.8 to 1.1 vac drop-out 0.3 to 0.6 vac 0.3 to 0.6 vac 50/60 hz coils operational 0.85 to 1.1 vac at 60 hz 0.85 to 1.1 vac at 60 hz drop-out 0.3 to 0.6 vac 0.3 to 0.6 vac average consumption at 20 c (68 f) and at vc 50 hz ac inrush 50 hz coilva?????? cos ? 0.75 0.75 0.75 0.75 0.75 0.75 50/60 hz coil va 70 70 70 70 70 70 sealed 50 hz coilva?????? cos ? 0.3 0.3 0.3 0.3 0.3 0.3 50/60 hz coilva777777 60 hz ac inrush 60 hz coilva?????? cos ? 0.75 0.75 0.75 0.75 0.75 0.75 50/60 hz coil va 70 70 70 100 70 70 sealed 60 hz coilva?????? cos ? 0.3 0.3 0.3 0.3 0.3 0.3 50/60 hz coil va 7.5 7.5 7.5 7.5 7.5 7.5 heat dissipation 50/60 hz w 2 to 3 2 to 3 2 to 3 2.5 to 3.5 2 to 3 2 to 3 operating time closing ?c? c ms 12 to 22 12 to 22 12 to 22 15 to 24 12 to 22 12 to 22 opening ?o? q ms 4 to 19 4 to 19 4 to 19 5 to 19 4 to 19 4 to 19 mechanical durability in millions of operating cycles 50 or 60 hz coil ?????? 50/60 hz coil at 50 hz 15 15 15 15 15 15 maximum operating rate at ambient temperature 55 c (131 f) in operating cycles per hour 3600 3600 3600 3600 3600 3600 c the closing time ?c? is measured from the moment the coil supply is switched on to initial contact of the main poles. q the opening time ?o? is measured from the moment the coil su pply is switched off to the moment the mains poles separate.
tesys? d-line contactors and starters characteristics of type lcd and lpd contactors 83 01/04 ? 2001-2004 schneider electric all rights reserved control circuit characteristics type lc1d40 lc1d50 lc1d65 lc1d80 lc1d95 lc1d115 lc1d150 rated control circuit voltage (vc) 50 or 60 hz v 24 to 660 24 to 500 control voltage limits ( 55 c [131 f]) 50 or 60 hz coils operational 0.85 to 1.1 vac ? drop-out 0.3 to 0.6 vac 0.3 to 0.5 vc ? 50/60 hz coils operational 0.85 to 1.1 vac at 60 hz 0.8 to 1.15 vac at 50/60 hz drop-out 0.3 to 0.6 vac 0.3 to 0.5 vac average consumption at 20 c (68 f) and at vc 50 hz ac inrush 50 hz coil va 200 200 200 200 200 300 ? cos ? 0.75 0.75 0.75 0.75 0.75 0.8 0.9 50/60 hz coil va 245 245 245 245 245 280-350 280-350 sealed 50 hz coil va 20 20 20 20 20 22 ? cos ? 0.3 0.3 0.3 0.3 0.3 0.3 0.9 50/60 hz coil va 26 26 26 26 26 2 to 18 2 to 18 60 hz ac inrush 60 hz coil va 220 220 220 220 220 300 ? cos ? 0.75 0.75 0.75 0.75 0.75 0.8 0.9 50/60 hz coil va 245 245 245 245 245 280-350 280-350 sealed 60 hz coil va 22 22 22 22 22 22 ? cos ? 0.3 0.3 0.3 0.3 0.3 0.3 0.9 50/60 hz coil va 26 26 26 26 26 6 6 heat dissipation 50/60 hz w 6 to 10 6 to 10 6 to 10 6 to 10 6 to 10 2 to 18 2 to 18 operating time closing ?c? c ms 20 to 26 20 to 26 20 to 26 20 to 35 20 to 35 20 to 50 20 to 35 opening ?o? q ms 8 to 12 8 to 12 8 to 12 6 to 20 6 to 20 6 to 20 40 to 75 mechanical durability in millions of operating cycles 50 or 60 hz coil 16 16 16 10 10 8 ? 50/60 hz coil at 50 hz 6664488 maximum operating rate at ambient temperature 55 c (131 f) in operating cycles per hour 3600 3600 3600 3600 3600 2400 1200 c the closing time ?c? is measured from the moment the coil supply is switched on to initial contact of the main poles. q the opening time ?o? is measured from the moment the coil supply is switched off to the moment the mains poles separate.
tesys? d-line contact ors and starters characteristics of type lcd and lpd contactors ? 2001-2004 schneider electric all rights reserved 84 01/04 dc control circuit characteristics type of contactor lc1 d09 to d38 dt20 to dt40 lp1 d12 and d25 lc1 or lp1 d40 to d65 lc1 or lp1d80 lc1d115 & lc1d150 rated control circuit voltage (uc) dc v 12 to 440 12 to 440 24 to 440 rated insulation voltage conforming to iec 60947-1 v 690 conforming to ul, csa v 600 control voltage limits operational standard coil 0.7 to 1.25 uc at 60 c (140 f) 0.8 to 1.1 uc @ 55 c (131 f) 0.85 to 1.1 uc at 55 c (131 f) 0.75 to 1.2 uc at 55 c (131 f) wide range coil ? 0.7 to 1.25 uc @ 55 c (131 f) 0.75 to 1.2 uc at 55 c (131 f) ? drop-out 0.1 to 0.25 uc at 60 c (140 f) 0.1 to 0.3 uc at 55 c (131 f) 0.15 to 0.4 uc at 55 c (131 f) average consumption at 20 c (68 f) and at uc dc inrush w 5.4 9/11 22 22 270 to 365 sealed w 5.4 9/11 22 22 2.4 to 5.1 average operating time at uc (1) closing ?c? ms 55 52 - 64 85 to 110 95 to 130 20 to 35 opening ?o? ms 20 8 - 14 20 to 35 20 to 35 40 to 75 note: the arcing time depends on the circuit switched by the poles. for normal three-phase applications, the arcing time is usually l ess than 10 ms. the load is isolated from the supply after a time equal to the sum of the opening time and the arcing time. time constant (l/r) ms 28 42 65 75 25 mechanical life at uc in millions of oper ating cycles 30 30 20 20 8 maximum operating rate at ambient temperature 60 c (140 f) in operating cycles per hour 3600 3600 3600 3600 1200 low consumption control circuit characteristics rated insulation voltage conforming to iec 60947-1 v 690 conforming to ul, csa v 600 maximum voltage of the control circuit on dc 250 average consumption dc at 20 c and at uc wide range coil (0.7 to 1.25 uc) inrush w 2.4 sealed w 2.4 operating time (1) at uc and at 20 c (68 f) closing ?c? ms 70 opening ?o? ms 25 voltage limits 60 c (140 f) of the control circuit operational 0.7 to 1.25 uc drop-out 0.1 to 0.3 uc time constant (l/r) ms 40 mechanical life in millions of operating cycles 30 maximum operating rate at ambient temperature 60 c (140 f) ops/h 3600 rated insulation voltage conforming to ul, csa v 600 conforming to iec 60947-1 v 690 (1) operating times depend on the type of contactor electromagnet and its control mode. the closing time ?c? is measured from the moment the coil supply is switched on to initial contact of the main poles. the openi ng time ?o? is measured from the moment the coil supply is switched off to the moment the main poles separate.
tesys? d-line contactors and starters characteristics of type lcd and lpd contactors 85 01/04 ? 2001-2004 schneider electric all rights reserved contactor integral auxiliary contact characteristics linked contacts conforming to draft standard iec 60947-4-5 each contactor has two n.o. and n.c. contacts mechanically linked on the same movable contact holder. mirror contact the n.c. contact on each contactor represents the state of the po wer contacts and can be connected to a preventa safety module rated operationa l voltage (ue) up to v 690 rated insulation voltage (ui) conforming to iec 60947-1 v 690 conforming to ul, csa v 600 conventional thermal current (ith) for ambient temperature 60 c (140 f) a 10 operating current frequency hz 25 to 400 minimum switching capacity u min. v 17 i min. ma 5 short-circuit protection k conforming to iec 60947-5-1 gg fuse: 10 a rated making capacity conforming to iec 60947-5-1, i rms a ac: 140; dc: 250 short-time rating permissible for 1 s a 100 500 ms a 120 100 ms a 140 insulation resistance m ? >10 non-overlap time guaranteed between n.c. and n.o. contacts ms 1.5 on energizing and on de-energizing k select short circuit protection to meet the national electrocal code or other local codes and standards. contact operating power conforming to iec 60947-5-1 ac supply categories ac-14 and ac-15 dc supply category dc-13 electrical life (valid for up to 3600 operating cycles/hour) on an inductive load such as the coil of an electromagnet: making power (cos ? 0.7) = 10 times the power broken (cos ? 0.4). electrical life (valid for up to 1200 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. v 24 48 115 230 400 440 600 v 24 48 125 250 440 1 million operating cycles va 60 120 280 560 960 1050 1440 w 96 76 76 76 44 3 million operating cycles va 16 32 80 160 280 300 420 w 48 38 38 32 ? 10 million operating cycles va 4820407080100 w 14 12 12 ? ? ac-15 current broken in a dc-13 current broken in a 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1234 5 6 7 8 9 10 0.1 0.2 0.3 0.4 0.6 0.5 0.8 0.7 7 1 2 3 5 4 6 8 1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1234 5 6 7 8 9 10 0.1 0.2 0.3 0.4 0.6 0.5 0.8 0.7 7 1 2 3 5 4 6 8 1 440 v 48 v 250 v 125 v 24 v
tesys? d-line contact ors and starters characteristics of type lcd and lpd contactors ? 2001-2004 schneider electric all rights reserved 86 01/04 power circuit connections type lc1 d09, d12 dt20, dt25 lc1d18 lc1dt32 lc1d25 lc1dt40 lc1d32 lc1d38 lc1d40 lp1d40 lc1d50 lp1d50 cabling (for screw clamp terminals) connector type screw clamp terminals box lug terminals stranded cable without cable end 1 conductor awg 18-10 18-8 18-8 14-6 ? 10-3 10-3 2 conductors awg 18-10 18-8 18-8 14-6 ? 10-4 10-4 1 conductor mm 2 1/4 1.5/6 1.5/10 2.5/10 2.5/10 2.5/25 2.5/25 2 conductors mm 2 1/4 1.5/6 1.5/6 2.5/10 2.5/10 2.5/16 2.5/16 stranded cable with cable end 1 conductor awg 18-10 18-3 18-3 18-3/0 ? 10-4 10-4 2 conductors awg 18-10 18-10 18-10 14-2 ? 12-2 12-2 1 conductor mm 2 1/4 1/6 1/6 1/10 1/10 2.5/25 2.5/25 2 conductors mm 2 1/2.5 1/4 1/4 1.5/6 1.5/6 2.5/10 2.5/10 solid cable without cable end 1 conductor awg 18-8 18-8 18-8 14-8 ? 10-3 10-3 2 conductors awg 18-8 18-8 18-8 10-8 ? 10-6 10-6 1 conductor mm 2 1/4 1.5/6 1.5/6 1.5/10 1.5/10 2.5/25 2.5/25 2 conductors mm 2 1/4 1.5/6 1.5/6 2.5/10 2.5/10 2.5/16 2.5/16 phillips head type n 2 n 2 n 2 n 2 n 2 ? ? screwdriver ? ? 6 ? 6 ? 6 ? 6 ? 6 ? 6 to ? 8 ? 6 to ? 8 hexagon spanner ? ? ? ? ? 4 mm 4 mm tightening torque 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 23 lb.-in. 2.5 n ? m 23 lb.-in. 2.5 n ? m 23 lb.-in. 2.5 n ? m 45 lb.-in. 5 n ? m 45 lb.-in. 5 n ? m bus bar connection (for bus bar or ring-tongue terminals) connection by bus bar or ring-tongue terminals bar c.s.a. ??????? lug external ? mm 8 8 10 10 10 13 16 screw ? mm m3.5 m3.5 m4 m4 m4 m5 m6 phillips head type n 2 n 2 n 2 n 2 n 2 n 2 n 3 screwdriver ? ? 6? 6? 6 3/16 in. ? 6 mm 3/16 in. ? 6 mm ? 8 mm ? 8 mm hexagon spanner ? ? ? ? ? ? ? tightening torque 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 20 lb.-in. 7.5 n ? m 20 lb.-in. 7.5 n ? m 53 lb.-in. 6 n ? m 71 lb.-in. 6 n ? m flexible cabling (for spring terminals) spring terminals flexible cable without cable end 1 conductor awg 14 12 12 12 12 ? ? 2 conductors awg 14 12 12 12 12 ? ? 1 conductor mm 2 2.54444?? 2 conductors mm 2 2.54444?? control circuit connections type lc1 d09, d12 dt20, dt25 lc1d18 lc1dt32 lc1d25 lc1dt40 lc1d32 lc1d38 lc1d40 lp1d40 lc1d50 lp1d50 connection by cable screw clamp terminals cabling stranded cable without cable end 1 conductor awg (mm 2 ) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 1/4 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 2 conductors awg (mm 2 ) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 1/4 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) stranded cable with cable end 1 conductor awg (mm 2 ) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 1/4 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 2 conductors awg (mm 2 ) 18 - 12 (1/2.5) 18 - 12 (1/2.5) 18 - 12 (1/2.5) 18 - 12 (1/2.5) 18 - 12 (1/2.5) 18 - 12 (1/2.5) 18 - 12 (1/2.5) solid cable without cable end 1 conductor awg (mm 2 ) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 1/4 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 2 conductors awg (mm 2 ) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 1/4 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) phillips head type n 2 n 2 n 2 n 2 n 2 n 2 n 2 screwdriver ? mm ? 6 ? 6 ? 6 ? 6 ? 6 ? 6 ? 6 tightening torque 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 17 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m connection by bus bar or ring-tongue terminals lug external ? mm 8 8 8 8 8 8 8 screw ? mm m3.5 m3.5 m3.5 m3.5 m3.5 m3.5 m3.5 phillips head type n 2 n 2 n 2 n 2 n 2 n 2 n 2 screwdriver ? 3/16 in. ? 6 3/16 in. ? 6 3/16 in. ? 6 3/16 in. ? 6 3/16 in. ? 6 3/16 in. ? 6 3/16 in. ? 6 tightening torque 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m
tesys? d-line contactors and starters characteristics of type lcd and lpd contactors 87 01/04 ? 2001-2004 schneider electric all rights reserved q one of each size range. power circuit connections type lc1d65 lp1d65 lc1d80 lp1d80 lc1d95 lc1d115 lc1d150 cabling (for screw clamp terminals) connector type box lug terminals la9d11560  terminals stranded cable without cable end 1 conductor awg 10-3 10-2 ? 8-250 mcm 8-250 mcm 2 conductors awg 10-4 10-4 ? 8-1+8-250 mcm q 8-1+8-250 mcm q 1 conductor mm 2 2.5/25 4/50 4/50 10/120 10/120 2 conductors mm 2 2.5/16 4/25 4/25 10/120+ 10/50 q 10/120+ 10/50 q stranded cable with cable end 1 conductor awg 10-4 10-4 ? ? ? 2 conductors awg 12-2 12-2 ? ? ? 1 conductor mm 2 2.5/25 4/50 4/50 10/120 10/120 2 conductors mm 2 2.5/10 4/16 4/16 10/120+ 10/50 q 10/120+ 10/50 q solid cable without cable end 1 conductor awg 10-3 10-3 ? 8-250 mcm 8-250 mcm 2 conductors awg 10-6 10-2 ? 8-0+ 8-250mcm q 8-0+8-250 mcm q 1 conductor mm 2 2.5/25 4/50 4/50 10/120 10/120 2 conductors mm 2 2.5/16 4/25 4/25 10/120+ 10/50 q 10/120+ 10/50 q phillips head type ? ? ? ? ? screwdriver ? ? 6 to ? 8 ? 6 to ? 8 ? 6 to ? 8 ? ? hexagon spanner 4 mm 4 mm 4 mm 4 mm 4 mm tightening torque 45 lb.-in. 5 n ? m 100 lb.-in. 11.3 n ? m 100 lb.-in. 11.3 n ? m 100 lb.-in. 11.3 n ? m 100 lb.-in. 11.3 n ? m bus bar connection (for bus bar or ring-tongue terminals) connection by bus bar or ring-tongue terminals bar c.s.a. ? 3 x 16 3 x 16 5 x 25 5 x 25 lug external ? mm 16 17 17 25 25 screw ? mm m6 m6 m6 m8 m8 phillips head type n 3 ? ? ? ? screwdriver ? ? 8 mm ? 8 mm ? 8 mm ? ? hexagon spanner ? 10 mm 10 mm 13 mm 13 mm tightening torque 71 lb.-in. 6 n ? m 71 lb.-in. 8 n ? m 71 lb.-in. 8 n ? m 124 lb.-in. 14 n ? m 124 lb.-in. 14 n ? m flexible cabling (for spring terminals) spring terminals flexible cable without cable end 1 conductor awg ? ? ? ? ? 2 conductors awg ? ? ? ? ? 1 conductor mm 2 ?? ? ? ? 2 conductors mm 2 ?? ? ? ? control circuit connections type lc1d65 lp1d65 lc1d80 lp1d80 lc1d95 lc1d115 lc1d150 connection by cable screw clamp terminals cabling stranded cable without cable end 1 conductor awg (mm 2 ) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 12 (1/2.5) 18 - 12 (1/2.5) 2 conductors awg (mm 2 ) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 12 (1/2.5) 18 - 12 (1/2.5) stranded cable with cable end 1 conductor awg (mm 2 ) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 12 (1/2.5) 18 - 12 (1/2.5) 2 conductors awg (mm 2 ) 18 - 12 (1/2.5) 18 - 12 (1/2.5) 18 - 12 (1/2.5) 18 - 12 (1/2.5) 18 - 12 (1/2.5) solid cable without cable end 1 conductor awg (mm 2 ) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 12 (1/2.5) 18 - 12 (1/2.5) 2 conductors awg (mm 2 ) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 10 (1/4) 18 - 12 (1/2.5) 18 - 12 (1/2.5) phillips head type n 2 n 2 n 2 n 2 n 2 screwdriver ? mm ? 6 ? 6 ? 6 ? 6 ? 6 tightening torque 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m connection by bus bar or ring-tongue terminals lug external ? mm 8 8 8 8 8 screw ? mm m3.5 m3.5 m3.5 m3.5 m3.5 phillips head type n 2 n 2 n 2 n 2 n 2 screwdriver ? 3/16 in. ? 6 3/16 in. ? 6 3/16 in. ? 6 3/16 in. ? 6 3/16 in. ? 6 tightening torque 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m 15 lb.-in. 1.7 n ? m
tesys? d-line contact ors and starters selection of contactors for motor control ? 2001-2004 schneider electric all rights reserved 88 01/04 selection of contactors for motor control the tables below show the kilowatt ratings (for inte rnational applications) and horsepower ratings (for north american applications) of contactors for motor control. ac and dc control circuit ? 3-pole contactors with touch-safe terminals for power cabling (ac-3 category) maximum horsepower ratings maximum inductive current in ac-3 category 600 v standard power ratings of 3- phase motors 50/60 hz in category ac-3 rated operating current in ac-3 up to 440 v instantaneous auxiliary contacts catalog number p f weight lb (kg) 1-phase 50/60 hz 3-phase 50/60 hz 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575 v 600 v 220 v 230 v 380 v 400 v 415 v 440 v 500 v 660 v 690 v 1000 v hp hp hp hp hp hp a kw kw kw kw kw kw kw a n.o. n.c. 0.5 1 2 2 5 7.5 9 2.2 4 4 4 5.5 5.5 ? 9 1 1 lc1d09 ?? 0.71 (0.320) 1 2 3 3 7.5 10 12 3 5.5 5.5 5.5 7.5 7.5 ? 12 1 1 lc1d12 ?? 0.72 (0.325) 1 3 5 5 101518 4 7.59 9 1010? 18 1 1 lc1d18 ?? 0.73 (0.330) 2 3 7.57.5152025 5.51111111515? 25 1 1 lc1d25 ?? 0.82 (0.370) 2 5 10 10 20 30 32 7.5 15 15 15 18.5 18.5 ? 32 1 1 lc1d32 ?? 0.83 (0.375) not for north american applications c 38 9 18.5 18.5 18.5 18.5 18.5 ? 38 1 1 lc1d38 ?? 0.84 (0.380) 3 5 10 10 30 30 40 11 18.5 22 22 22 30 22 40 1 1 lc1d40 ?? 3.11 (1.400) 3 7.5 15 15 40 40 50 15 22 25 30 30 33 30 50 1 1 lc1d50 ?? 3.11 (1.400) 5 10 2020505065 18.5303737373737 65 1 1 lc1d65 ?? 3.11 (1.400) 7.5 15 2530606080 22374545554545 80 1 1 lc1d80 ?? 3.53 (1.590) not for north american applications c 95 25 45 45 45 55 45 45 95 1 1 lc1d95 ?? 3.58 (1.610) ? ? 30 40 75 100 115 30 55 59 59 75 80 75 115 1 1 lc1d115 ?? 5.38 (2.420) ? ? 40 50 100 125 150 40 75 80 80 90 100 90 150 1 1 lc1d150 ?? 5.42 (2.440) f for lc1d09 to lc1d38 : clip-on mounting on 35 mm din rail am1dp or screw mounting. for lc1d40 to lc1d95 : clip-on mounting on 35 mm din rail am1de or 75 mm din rail am1dl or screw mounting. for lc1d115 and lc1d150 : clip-on mounting on 2 x 35 mm din rails am1dp or screw mounting. p use voltage codes on page 115 ?voltage code table? to complete catalog number. c devices are ul listed at the same hp ratings as 32 and 80 amp devices, respectively. lc1d09 ?? lc1d65 ?? lc1d150 ??
tesys? d-line contactors and starters selection of contactors for motor control 89 01/04 ? 2001-2004 schneider electric all rights reserved the tables below show the kilowatt ratings (for in ternational applications) and horsepower ratings (for north american applications) of contactors for motor control. ac and dc control circuit ? 3-pole contactors for spring terminal connections (ac-3 category) maximum horsepower ratings maximum inductive current in ac-3 category 600 v standard power ratings of 3-phase motors 50/60 hz in category ac-3 rated operating current in ac-3 up to 440 v instantaneous auxiliary contacts catalog number p f weight lb (kg) 1-phase 50/60 hz 3-phase 50/60 hz 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575 v 600 v 220 v 230 v 380 v 400 v 415 v 440 v 500 v 660 v 690 v 1000 v hp hp hp hp hp hp a kwkwkwkwkwkwkw a n.o.n.c. 0.5 1 2 2 5 7.5 9 2.2 4 4 4 5.5 5.5 ? 9 1 1 lc1d093 ?? 0.71 (0.320) 1 2 3 3 7.5 10 12 3 5.5 5.5 5.5 7.5 7.5 ? 12 1 1 lc1d123 ?? 0.72 (0.325) 1 3 5 5 10 15 18 4 7.5 9 9 10 10 ? 18 1 1 lc1d183 ?? 0.73 (0.330) 2 3 7.57.5152025 5.51111111515? 25 1 1 lc1d253 ?? 0.82 (0.370) 2 5 10 10 20 30 32 7.5 15 15 15 18.5 18.5 ? 32 1 1 lc1d323 ?? 0.83 (0.375) not for north american applications c 38 9 18.5 18.5 18.5 18.5 18.5 ? 38 1 1 lc1d383 ?? 0.84 (0.380) f for lc1d09 to lc1d38 : clip-on mounting on 35 mm din rail am1dp or screw mounting. p use voltage codes on page 115 ?voltage code table? to complete catalog number. c device is ul listed at the same hp ratings as 32 amp device. lc1d123 ??
tesys? d-line contact ors and starters selection of contactors for motor control ? 2001-2004 schneider electric all rights reserved 90 01/04 the tables below show the kilowatt ratings (for inte rnational applications) and horsepower ratings (for north american applications) of contactors for motor control. ac and dc control circuit ? 3- pole contactors for connecti on with slip-on connectors for contactors lc1d09 and lc1d12 only, replace the last digit in the catalog numbers shown in the table above (?6?) with a 9. for example, lc1d096 ?? becomes lc1d099 ?? . these contactors include slip-on connectors: ul recognized e164862 nldx2 , 2 x 6.35 mm (0.25 in.) on the power poles and 1 x 6.35 mm (0.25 in.) on the coil terminals. ac and dc control circuit ? 3-pole contactors for ring-tongue terminals or bus bar power connections (ac-3 category) maximum horsepower ratings maximum inductive current in ac-3 category 600 v standard power ratings of 3-phase motors 50/60 hz in category ac-3 rated operating current in ac-3 up to 440 v instantaneous auxiliary contacts catalog number f p weight lb (kg) 1-phase 50/60 hz 3-phase 50/60 hz 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575 v 600 v 220 v 230 v 380 v 400 v 415 v 440 v 500 v 660 v 690 v 1000 v hp hp hp hp hp hp a kw kw kw kw kw kw kw a n.o. n.c. 0.51 2257.59 2.24445.55.5? 9 1 1 lc1d096 ?? 0.71 (0.320) 1 2 3 3 7.5 10 12 3 5.5 5.5 5.5 7.5 7.5 ? 12 1 1 lc1d126 ?? 0.72 (0.325) 1 3 5 5 10 15 18 4 7.5 9 9 10 10 ? 18 1 1 lc1d186 ?? 0.73 (0.330) 2 3 7.5 7.5 15 20 25 5.5 11 11 11 15 15 ? 25 1 1 lc1d256 ?? 0.82 (0.370) 2 5 10 10 20 30 32 7.5 15 15 15 18.5 18.5 ? 32 1 1 lc1d326 ?? 0.83 (0.375) not for north american applications c 38 9 18.5 18.5 18.5 18.5 18.5 ? 38 1 1 lc1d386 ?? 0.84 (0.380) 3 5 10 10 30 30 40 11 18.5 22 22 22 30 22 40 1 1 lc1d406 ?? 2.93 (1.320) 3 7.5 15 15 40 40 50 15 22 25 30 30 33 30 50 1 1 lc1d506 ?? 2.93 (1.320) 5 10 2020505065 18.5303737373737 65 1 1 lc1d656 ?? 2.93 (1.320) 7.5 15 2530606080 22374545554545 80 1 1 lc1d806 ?? 3.55 (1.600) not for north american applications c 95 25 45 45 45 55 45 45 95 1 1 lc1d956 ?? 3.55 (1.600) ? ? 30 40 75 100 115 30 55 59 59 75 80 75 115 1 1 lc1d1156 ?? 4.69 (2.110) ? ? 40 50 100 125 150 40 75 80 80 90 100 90 150 1 1 lc1d1506 ?? 4.69 (2.130) f for lc1d09 to lc1d38 : clip-on mounting on 35 mm din rail am1dp or screw mounting. for lc1d40 to lc1d95 : clip-on mounting on 35 mm din rail am1de or 75 mm din rail am1dl or screw mounting. for lc1d115 and lc1d150 : clip-on mounting on 2 x 35 mm din rails am1dp or screw mounting. p use voltage codes on page 115 ?voltage code table? to complete catalog number. c devices are ul listed at the same hp ratings as 32 and 80 amp devices, respectively. lc1d1506 ??
tesys? d-line contactors and starters selection of contactors for resistive loads (ac-1) and inductive loads (ac-3) 91 08/04 ? 2001-2004 schneider electric all rights reserved selection of contactors for resistive loads ac and dc control circuit ? 3- or 4-pole screw terminal connections (ac-1 category) maximum current utilization categories number of poles instantaneous auxiliary contacts catalog number f p weight lb (kg) ac-1 ac-3 n.o. n.c. n.o. n.c. 20 9 3011 lc1d09 ?? 0.71 (0.320) 4011 lc1dt20 ?? 0.80 (0.365) 2211 lc1d098 ?? 0.80 (0.365) 25 12 3011 lc1d12 ?? 0.75 (0.340) 4011 lc1dt25 ?? 0.80 (0.365) 2211 lc1d128 ?? 0.80 (0.365) 32 18 3011 lc1d18 ?? 0.79 (0.355) 4011 lc1dt32 ?? 0.93 (0.425) 2211 lc1d188 ?? 0.93 (0.425) 40 25 3011 lc1d25 ?? 0.82 (0.370) 4011 lc1dt40 ?? 0.93 (0.425) 2211 lc1d258 ?? 0.93 (0.425) 50 32 3011 lc1d32 ?? 0.83 (0.375) 3011or q lc1d38 ?? c 0.84 (0.380) 60 40 3011 lc1d40 ?? 3.11 (1.400) 4011 lc1d40004 ?? 0.93 (0.425) 2211 lc1d40008 ?? 0.93 (0.425) 4011 lp1d40004 ?? 0.93 (0.425) 2211 lp1d40008 ?? 0.93 (0.425) 80 50 3 0 1 1 lc1d50 ?? 3.22 (1.450) 65 3011or q lc1d65 ?? 3.11 (1.400) 4000 lc1d65004 ?? 3.20 (1.440) 4000 lp1d65004 ?? 4.89 (2.220) 2200 lc1d65008 ?? 3.22 (1.450) 2200 lp1d65008 ?? 4.89 (2.220) 125 80 3 0 1 1 lc1d80 ?? 3.53 (1.590) 95 3 0 1 1 or q lc1d95 ?? c 3.55 (1.600) 80 4000 lc1d80004 ?? 3.91 (1.760) 4000 lp1d80004 ?? 4.87 (2.210) 2200 lc1d80008 ?? 4.09 (1.940) 2200 lp1d80008 ?? 5.84 (2.650) 200 115 3 0 1 1 lc1d115 ?? 5.38 (2.420) 150 3 0 1 1 or q lc1d150 ?? 5.42 (2.440) 115 4 0 0 0 lc1d115004 ?? 6.35 (2.860) ac and dc control circuit ? 3- or 4-pole spring terminal connections (ac-1 category) 20 9 3011 g lc1d093 ?? 0.710 (0.320) 4011 g lc1dt203 ?? 0.837 (0.380) 2211 g lc1d0983 ?? 0.837 (0.380) 25 12 3011 g lc1d123 ?? 0.710 (0.320) 4011 g lc1dt253 ?? 0.840 (0.380) 2211 g lc1d1283 ?? 0.840 (0.380) 32 ?3011 g lc1d183 ?? 0.730 (0.330) 18 4 0 1 1 g lc1dt323 ?? 0.940 (0.425) ?2211 g lc1d1883 ?? 0.940 (0.425) 40 ?3011 g lc1d253 ?? 0.820 (0.370) 25 4 0 1 1 g lc1dt403 ?? 0.940 (0.425) ?2211 g lc1d2583 ?? 0.940 (0.425) f for lc1d09 to lc1d38 : clip-on mounting on 35 mm din rail am1dp or screw mounting. for lc1d40 to lc1d95 : clip-on mounting on 35 mm din rail am1de or 75 mm din rail am1dl or screw mounting. for lc1d115 and lc1d150 : clip-on mounting on 2 x 35 mm din rails am1dp or screw mounting. g for lc1d09 to lc1d25 : clip-on mounting on 35 mm din rail am1dp or screw mounting. q select between the two shown based upon the number of operating cycles; see the ac-1 graph on page 22 for further information. p use voltage codes on page 115 ?voltage code table? to complete catalog number. c devices are ul listed at the same ratings as 32 and 80 amp devices, respectively. lc1dt20 ??
tesys? d-line contact ors and starters resistive loads (ac-1) and inductive loads (ac-3) ? 2001-2004 schneider electric all rights reserved 92 08/04 resistive loads ac and dc control circuit ? contactors for co nnection with slip-on connectors (3-pole only) ac-1 category for contactors lc1d09 and lc1d12 only, replace the last digit in the catalog numbers shown in the table above (?6?) with a 9. for example, lc1d096 ?? becomes lc1d099 ?? . these contactors include slip-on connectors: ul recognized e164862 nldx2 , 2 x 6.35 mm (0.25 in.) on the power poles and 1 x 6.35 mm (0.25 in.) on the coil terminals. ac and dc control circuit ? 3- or 4-pole contactors for ring terminals or bus bar power connections (ac-1 category) maximum current utilization categories number of poles instantaneous auxiliary contacts catalog number f p weight lb (kg) ac-1 ac-3 n.o. n.c. n.o. n.c. 20 9 3011 lc1d096 ?? 0.71 (0.320) 4011 lc1dt206 ?? 0.80 (0.365) 2211 lc1d0986 ?? 0.80 (0.365) 25 12 3011 lc1d126 ?? 0.75 (0.340) 4011 lc1dt256 ?? 0.80 (0.365) 2211 lc1d1286 ?? 0.80 (0.365) 32 18 3011 lc1d186 ?? 0.79 (0.355) 4011 lc1dt326 ?? 0.93 (0.425) 2211 lc1d1886 ?? 0.93 (0.425) 40 25 3011 lc1d256 ?? 0.82 (0.370) 4011 lc1dt406 ?? 0.93 (0.425) 2211 lc1d2586 ?? 0.93 (0.425) 50 32 3011 lc1d326 ?? 0.83 (0.375) 3 0 11or q lc1d386 ?? c 0.84 (0.380) 60 40 3011 lc1d406 ?? 3.11 (1.400) 4011 lc1d400046 ?? 0.93 (0.425) 2211 lc1d400086 ?? 0.93 (0.425) 4011 lp1d40004 ?? 0.93 (0.425) 2211 lp1d40008 ?? 0.93 (0.425) 80 65 3011 lc1d656 ?? 3.11 (1.400) 80 4000 lc1d800046 ?? 3.20 (1.440) 4000 lp1d800046 ?? 4.89 (2.220) 2200 lc1d800086 ?? 3.22 (1.450) 2200 lp1d800086 ?? 4.89 (2.220) 125 80 3011 lc1d806 ?? 3.53 (1.590) 4000 lc1d800046 ?? 3.91 (1.760) 4000 lp1d800046 ?? 4.87 (2.210) 2200 lc1d800086 ?? 4.09 (1.940) 2200 lp1d800086 ?? 5.84 (2.650) 95 3011 lc1d95 ?? c 3.55 (1.600) 200 1153011 lc1d1156 ?? 5.38 (2.420) 150 3 0 11or q lc1d1506 ?? 5.42 (2.440) 1154000 lc1d1150046 ?? 6.35 (2.860) f for lc1d09 to lc1d38 : clip-on mounting on 35 mm din rail am1dp or screw mounting. for lc1d40 to lc1d95 : clip-on mounting on 35 mm din rail am1de or 75 mm din rail am1dl or screw mounting. for lc1d115 and lc1d150 : clip-on mounting on 2 x 35 mm din rails am1dp or screw mounting. q select between the two shown based upon the number of operating cycles and control voltage; see the ac-1 graph on page 22 for f urther information. p use voltage codes on page 115 ?voltage code table? to complete catalog number. c devices are ul listed at the same ratings as 32 and 80 amp devices, respectively. lc1d150 ??
tesys? d-line contactors and starters selection of reversing contactors for motor control 93 01/04 ? 2001-2004 schneider electric all rights reserved selection of reversing contactors for motor control the tables below show the kilowatt ratings (for in ternational applications) and horsepower ratings (for north american applications) of contactors for motor control. the contactors are pre-assembled, horizontally-mo unted, and have pre-wired power connections. order accessories separately. for information on au xiliary contact blocks and modules, see pages 106 to 107. ac and dc control circuit ? 3-pole re versing contactors with touch-safe termi nals for power cabling (ac-3 category) maximum horsepower ratings maximum inductive current in ac-3 category 600 v standard power ratings of 3-phase motors 50/60 hz in category ac-3 rated operating current in ac-3 up to 440 v instantaneous auxiliary contacts catalog number f p weight lb (kg) 1-phase 50/60 hz 3-phase 50/60 hz 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575 v 600 v 220 v 230 v 380 v 400 v 415 v 440 v 500 v 660 v 690 v 1000 v hp hp hp hp hp hp a kw kw kw kw kw kw kw a n.o. n.c. 0.51 2257.59 2.24445.55.5?9 11 lc2d09 ?? q k 1.55 (0.700) 1 2 3 3 7.5 10 12 3 5.5 5.5 5.5 7.5 7.5 ? 12 1 1 lc2d12 ?? q k 1.55 (0.700) 1 3 5 5 101518 4 7.59 9 1010? 18 1 1 lc2d18 ?? q k 1.670 (0.75) 2 3 7.5 7.5 15 20 25 5.5 11 11 11 15 15 ? 25 1 1 lc2d25 ?? q k 2.44 (1.100) 2 5 1010203032 7.515151518.518.5? 32 1 1 lc2d32 ?? q k 2.67 (1.200) not for north american applications 38 9 18.5 18.5 18.5 18.5 18.5 ? 38 1 1 lc2d38 ?? q k w 2.67 (1.200) 3 5 1010303040 1118.522222230? 40 1 1 lc2d40 ?? q 5.33 (2.400) 3 7.5 15 15 40 40 50 15 22 25 30 30 33 ? 50 1 1 lc2d50 ?? q 5.33 (2.400) 5 10 2020505065 18.53037373737? 65 1 1 lc2d65 ?? q 5.33 (2.400) 7.5 15 2530606080 223745455545? 80 1 1 lc2d80 ?? q 7.11 (3.200) not for north american applications 95 25 45 45 45 55 45 ? 95 1 1 lc2d95 ?? q w 7.11 (3.200) ? ? 304075100115 30555959758075115 1 1 lc2d115 c 14.44 (6.500) ? ? 40 50 100 125 150 40 75 80 80 90 100 90 150 1 1 lc2d150 c 14.44 (6.500) f for lc2d09 to lc2d38 : clip-on mounting on 35 mm din rail am1dp or screw mounting. for lc2d40 to lc2d95 : clip-on mounting on 35 mm din rail am1de or 75 mm din rail am1dl or screw mounting. for lc2d115 and lc2d150 : clip-on mounting on 2 x 35 mm din rails am1dp or screw mounting. q includes mechanical interlock without electrical contacts. insta ller to complete wiring for electr ically interlocking contactor operating coils by utilizing a n.c. auxiliary contact integrated in the contactor or optional ladn or lad8n type auxiliary contact block. c included with electrical contacts integrated in mechanical interlock (type la9d ?? 02 ). p use voltage codes on page 115 ?voltage code table? to complete catalog number. k for reversing contactors with electrical interlocking pre-wired at the factory, add suffix v to the catalog number reflected above. example: lc2d09 ?? becomes lc2d09 ?? v . w devices are ul listed at the same hp ratings as 32 and 80 amp devices, respectively.
tesys? d-line contact ors and starters selection of reversing contactors for motor control ? 2001-2004 schneider electric all rights reserved 94 01/04 the tables below show the kilowatt ratings (for inte rnational applications) and horsepower ratings (for north american applications) of contactors for motor control. the contactors are pre-assembled, horizontally -mounted, and have pre-wired power connections. order accessories separately. for information on auxiliary contact blocks and modules, see pages 106 to 107. ac and dc control circuit ? 3-pole reversing contactors for spring terminal connections (ac-3 category) maximum horsepower ratings maximum inductive current in ac-3 category 600 v standard power ratings of 3-phase motors 50/60 hz in category ac-3 rated operating current in ac-3 up to 440 v instantaneous auxiliary contacts catalog number f p t weight lb (kg) 1-phase 50/60 hz 3-phase 50/60 hz 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575 v 600 v 220 v 230 v 380 v 400 v 415 v 440 v 500 v 660 v 690 v 1000 v hp hp hp hp hp hp a kw kw kw kw kw kw kw a n.o. n.c. 0.51 2257.59 2.24445.55.5?9 11 lc2d093 ?? q 1.55 (0.700) 1 2 3 3 7.5 10 12 3 5.5 5.5 5.5 7.5 7.5 ? 12 1 1 lc2d123 ?? q 1.55 (0.700) 1 3 5 5 101518 4 7.59 9 1010? 18 1 1 lc2d183 ?? q 1.670 (0.75) 2 3 7.5 7.5 15 20 25 5.5 11 11 11 15 15 ? 25 1 1 lc2d253 ?? q 2.44 (1.100) 2 5 10 10 20 30 32 7.5 15 15 15 18.5 18.5 ? 32 1 1 lc2d323 ?? q 2.67 (1.200) not for north american applications 38 9 18.5 18.5 18.5 18.5 18.5 ? 38 1 1 lc2d383 ?? q k 2.67 (1.200) f for lc2d09 to lc2d38 : clip-on mounting on 35 mm din rail am1dp or screw mounting. q includes mechanical interlock without electrical contacts. instal ler to complete wiring for electr ically interlocking contactor operating coils by utilizing a n.c. auxiliary contact integrated in the contactor or optional ladn or lad8n type auxiliary contact block. p use voltage codes on page 115 ?voltage code table? to complete catalog number. t for reversing contactors with electrical interlocking pre-wired at the factory, add suffix v to the catalog number reflected above. example: lc2d09 ?? becomes lc2d09 ?? v . k lc2d38 is ul listed at the same hp rating as the 32 amp device.
tesys? d-line contactors and starters selection of reversing contactors for motor control 95 01/04 ? 2001-2004 schneider electric all rights reserved the tables below show the kilowatt ratings (for in ternational applications) and horsepower ratings (for north american applications) of contactors for motor control. the contactors have pre-wired power connections. order accessories separately. for information on auxiliary contact blocks and modules, see pages 106 to 107. ac and dc control circuit ? 3-pole reversing contactors for connection with slip-on connectors (ac-3 category) for contactors lc2d09 and lc2d12 only, replace the last digit in the catalog numbers shown in the table above (?6?) with a 9. for example, lc2d096 ?? becomes lc2d099 ?? . these contactors include slip-on connectors: ul recognized e164862 nldx2 , 2 x 6.35 mm (0.25 in.) on the power poles and 1 x 6.35 mm (0.25 in.) on the coil terminals. power connections are to be made by the customer. ac and dc control circuit ? 3-pole reversing contactors for ring-tongue terminals or bus bar power connections (ac-3 category) maximum horsepower ratings maximum inductive current in ac-3 category 600 v standard power ratings of 3-phase motors 50/60 hz in category ac-3 rated operating current in ac-3 up to 440 v instantaneous auxiliary contacts catalog number f p weight 1-phase 50/60 hz 3-phase 50/60 hz 115/ 120 v 230/ 240 v 200/ 208 v 220/ 240 v 460/ 480 v 575 v 600 v 220 v 230 v 380 v 400 v 415 v440 v500 v 660 v 690 v 1000 v hp hp hp hp hp hp a kw kw kw kw kw kw kw a n.o. n.c. lb (kg) 0.51 2257.59 2.24445.55.5?9 1 1 lc2d096 ?? q 1.55 (0.700) 1 2 3 3 7.5 10 12 3 5.5 5.5 5.5 7.5 7.5 ? 12 1 1 lc2d126 ?? q 1.55 (0.700) 1 3 5 5 101518 4 7.59 9 1010? 18 1 1 lc2d186 ?? q 1.67 (0.750) 2 3 7.5 7.5 15 20 25 5.5 11 11 11 15 15 ? 25 1 1 lc2d256 ?? q 2.44 (1.100) 2 5 1010203032 7.515151518.518.5? 32 1 1 lc2d326 ?? q 2.67 (1.200) not for north american applications 38 9 18.5 18.5 18.5 18.5 18.5 ? 38 1 1 lc2d386 ?? q k 2.67 (1.200) ? ? 30 40 75 100115 30555959758075 115 1 1 lc2d1156 ?? c q 13.22 (5.950) ? ? 15 15 40 40 150 40 70 80 80 90 100 90 150 1 1 lc2d1506 ?? c q 13.22 (5.950) f for lc2d09 to lc2d38 : clip-on mounting on 35 mm din rail am1dp or screw mounting. for lc2d115 and lc2d150 : clip-on mounting on 2 x 35 mm din rails am1dp or screw mounting. q includes mechanical interlock without electrical contacts. installer to complete wiring for electronically interlocking contact or operating coils by utilizing a n.c. auxiliary contact integrated in the contactor or optional ladn or lad8n type auxiliary contact block. c included with electrical contacts integrated in mechanical interlock (type la9d ?? 02 ). p use voltage codes on page 115 ?voltage code table? to complete catalog number. k lc2d386 devices are ul listed at the same hp rating as the 32 amp device. lc2d186 ??
tesys? d-line contact ors and starters selection of changeover contactors for resistive loads (ac-1) and inductive loads (ac-3) ? 2001-2004 schneider electric all rights reserved 96 08/04 selection of changeover contactors for resistive loads the contactors have pre-wired power connections. order accessories separately. for information on auxiliary contact blocks and modules, see pages 106 to 107. ac and dc control circuit ? 4-pole changeover contactors with touch-safe te rminals for power cabling (ac-1 category) maximum current utilization categories instantaneous auxiliary contacts catalog number f p weight ac-1 ac-3 n.o. n.c. lb (kg) 20 9 1 1 lc2dt20 ?? q 1.60 (0.730) 25 12 1 1 lc2dt25 ?? q 1.55 (0.700) 32 18 1 1 lc2dt32 ?? q 1.86 (0.450) 40 25 1 1 lc2dt40 ?? q 2.43 (1.100) 60 40 11 lc2d40004 ?? q 5.30 (2.400) 11 lp2d40004 ?? q 5.30 (2.400) 80 65 ?? lc2d65004 ?? q 7.07 (3.200) ?? lp2d80004 ?? q 7.07 (3.200) 125 80 ?? lc2d80004 ?? q 7.07 (3.200) ?? lp2d80004 ?? q 7.07 (3.200) 200 115 ? ? lc2d115004 ?? c 16.0 (27.250) f for lc2d12 and lc2d25 : clip-on mounting on 35 mm din rail am1dp or screw mounting. for lc2d40 to lc2d95 : clip-on mounting on 35 mm din rail am1de or 75 mm din rail am1dl or screw mounting. for lc2d115 : clip-on mounting on 2 x 35 mm din rails am1dp or screw mounting. q includes mechanical interlock (type la9 ?? d978 ) without electrical contacts. installer to complete wiring for electronically interlocking contactor operating coils by utilizing a n.c. auxiliary co ntact integrated in the contactor or optional la1dn or la8dn type auxiliary contact block. c includes mechanical interlock (type la9d11502) with pre-wired electrical contacts for interlocking contactor operating coils. p use voltage codes on page 115 ?voltage code table? to complete catalog number. lc2dt20 ??
tesys? d-line contactors and starters selection of changeover contactors for resistive loads (ac-1) and inductive loads (ac-3) 97 08/04 ? 2001-2004 schneider electric all rights reserved ac and dc control circuit? 4-pole changeover contactors with ring-tongue terminal or bus bar power connection (ac-1 category) maximum current utilization categories instantaneous auxiliary contacts catalog number f p weight lb (kg) ac-1 ac-3 n.o. n.c. 20 9 1 1 lc2dt206 ?? q 1.60 (0.730) 25 12 1 1 lc2dt256 ?? q 1.55 (0.700) 32 18 1 1 lc2dt326 ?? q 1.86 (0.450) 40 25 1 1 lc2dt406 ?? q 2.43 (1.100) 60 40 11 lc2d400046 ?? q 5.30 (2.400) 11 lp2d400046 ?? q 5.30 (2.400) 80 65 ?? lc2d650046 ?? q 7.07 (3.200) ?? lp2d800046 ?? q 7.07 (3.200) 125 80 ?? lc2d800046 ?? q 7.07 (3.200) ?? lp2d800046 ?? q 7.07 (3.200) 200 115 ? ? lc2d1150046 ?? c 16.0 (27.250) f for lc2d12 and lc2d25 : clip-on mounting on 35 mm din rail am1dp or screw mounting. for lc2d40 to lc2d95 : clip-on mounting on 35 mm din rail am1de or 75 mm din rail am1dl or screw mounting. for lc2d115 : clip-on mounting on 2 x 35 mm din rails am1dp or screw mounting. q includes mechanical interlock (type la9 ?? d978 ) without electrical contacts. installer to complete wiring for electronically interlocking contactor operating coils by utilizing a n.c. auxiliary cont act integrated in the contactor or optional la1dn or la8dn type auxiliary contact block. c includes mechanical interlock (type la9d11502 ) with pre-wired electrical contacts for interlocking contactor operating coils. p use voltage codes on page 115 ?voltage code table? to complete catalog number.
tesys? d-line contact ors and starters component parts for reversing and two speed contactors ? 2001-2004 schneider electric all rights reserved 98 01/04 component parts for reversing and two speed contactors for 3-pole motor reversing contactors contactors with screw clamp terminals or connectors horizontally mounted, assembled by customer using 2 identical contactors (1) set of power connections me chanical interlock kit catalog number weight lb (kg) catalog number weight lb (kg) including mechanical interlock and an elec trical interlocking kit for the contactors power connections for lc1d09 to d38 use with screw terminal ve rsions lc1d09 - lc1d38 line side (parallel) connector lad9v5 0.037 (0.17) lad9r1v (2) ? load side (reversing) connector lad9v6 0.037 (0.17) lad9r1v (2) ? low voltage control circuit interlock lad9v1 (3) 0.037 (0.17) lad9r1v (2) ? use with spring terminal versions lc1d093 - lc1d383 when using quick-fit lad34 and lad33 power connectors line side (parallel) connector lad9v10 0.037 (0.17) lad9v2 ? load side (reversing) connector lad9v11 0.037 (0.17) lad9v2 ? when using standard cable/wire line side (parallel) connector lad9v12 0.037 (0.17) lad9v2 ? load side (reversing) connector lad9v13 0.037 (0.17) lad9v2 ? including mechanical interlock with integral electrical interlocking lc1d40 to d65 la9d6569 0.290 (0.64) la9d4002 0.37 (0.170) lc1d80 and d95 (ac) la9d8069 0.290 (0.64) la9d4002 0.37 (0.170) lc1d80 and d95 (dc) la9d8069 0.490 (1.08) la9d8002 0.37 (0.170) lc1d115 and d150 la9d11569 1.450 (3.20) la9d11502 0.63 (0.290) including mechanical interlock without electrical interlocking power connections for lc1d09 to d38 line side (parallel) connector lad9v5 0.045 (0.10) lad9r1 (2) ? load side (reversing) connector lad9v6 0.045 (0.10) lad9r1 (2) ? lc1d40 to d65 la9d6569 0.290 (0.64) la9d50978 0.37 (0.170) lc1d80 and d95 (ac) la9d8069 0.490 (1.08) la9d50978 0.37 (0.170) lc1d80 and d95 (dc) la9d8069 0.490 (1.08) la9d80978 0.37 (0.170) for low speed ? high speed starter description for contactors with conn ections catalog number weight lb (kg) connection kit enabling reversing of slow and high speed directions, using a reversing contactor and a 2 n.o. + 2 n.c. main pole contactor screw clamps or connectors la9d9pvgv 0.03 (0.016) spring terminals lad3pvpg 0.15 (0.068) (1) to order the 2 contactors: see pages 88, 89 and 90. (2) mechanical interlock kit includes line and load side power connectors, mechanical interlock, control circuit interlock (lad9 r1v only), and clip. interlock only -- lad9v2 (includes retaining clip). retaining clip only -- w116430980111 (std. package of 10). (3) there is no spring terminal equivalent for this part. (4) line side (parallel) connector: lad9v5; load side (reversing) connector: lad9v6. characteristics: pages 80 to 87 dimensions, schematics: pages 128, 129 la9d4002 la9d6569 la9d8069 lad9r1
tesys? d-line contactors and starters component parts for assembling changeover contactor parts for distribution 99 01/04 ? 2001-2004 schneider electric all rights reserved component parts for assembling changeover contactor parts for distribution for 4-pole changeover contactor pairs (3-phase distribution + neutral) contactors with screw clamp terminals or connectors horizontally mounted, assembled by customer using 2 identical contactors (1) set of power connections mechanical interlock catalog number weight lb (kg) cata log number of kit weight lb (kg) including mechanical interlock and an elec trical interlocking kit for the contactors lc1dt20 to dt40 ladt9r1v (2) 0.088 (0.040) ? ? including mechanical interlock with integral electrical interlocking lc1d65004 la9d6570 0.33 (0.150) la9d4002 0.37 (0.170) lc1d80004 la9d8070 0.62 (0.280) la9d4002 0.37 (0.170) lp1d80004 la9d8070 0.62 (0.280) la9d8002 0.37 (0.170) lc1d115004 la9d11570 2.43 (1.100) la9d11502 0.62 (0.280) including mechanical interlock wi thout electrical interlocking lc1dt20 to dt40 with screw clamp terminals or connectors ladt9r1 (2) 0.08 (0.035) ? ? lc1dt203 to dt403 with spring terminal connections (4) ? ? ? lc1 or lp1d65004 la9d6570 (3) 0.33 (0.150) la9d50978 0.34 (0.155) lc1d80004 la9d8070 (3) 0.62 (0.280) la9d50978 0.34 (0.155) lp1d80004 la9d8070 (3) 0.62 (0.280) la9d80978 0.40 (0.180) for 3-pole changeover contactor pairs including mechanical interlock with integral electrical interlocking lc1d115 and d150 la9d11571 2.12 (0.960) la9d11502 0.62 (0.280) (1) to order the two contactors: see page 91. (2) including mechanical interlock. (3) order two contact bocks ladn ? 1 to obtain electrical interlocking between the contactors, see page 106. (4) to build a reversing contactor with spring terminal connections, the following components must be ordered in addition to the two contactors: - 1 mechanical interlock lad9v2, - 1 downstream power connection kit lad9v9 la9d4002 la9d50978 la9d8070
tesys? d-line contact ors and starters characteristics of auxiliary contacts, timers, and accessories ? 2001-2004 schneider electric all rights reserved 100 01/04 characteristics of auxiliary contact blocks, timers, and accessories auxiliary contact blocks without dust and damp protected contacts for contactors environment contact block type ladn or c ladt and s ladr lad8 conforming to standards meets the essential requirements of the lv & emc directives iec 60947-5-1, nf c 63-140, vde 0660, bs 4794, en 60947-5-1 product certifications ul, csa protective treatment conforming to iec 60068 ?th? degree of protection conforming to vde 0106 protection against direct finger contact ip 2x ambient air temperature around the device storage c - 60 to + 80 (- 140 to + 176 f) operation c - 5 to + 60 (- 41to + 140 f) permissible for operation at uc c - 40 to + 70 (- 104 to + 158 f) maximum operating altitude without derating m 3000 cabling phillips n 2 and ? 6 mm flexible or solid cable with or without cable end mm 2 min.: 1 x 1; max.: 2 x 2.5 (#10 awg) connection by spring terminals flexible or solid cable without cable end mm 2 max.: 2 x 2.5 (#10 awg) instantaneous and time delay contact characteristics number of contacts 1, 2 or 4 2 2 2 rated operational voltage (ue) up to v 690 rated insulation voltage (ui) conforming to iec 60947-5-1 v 690 conforming to ul, csa v 600 conventional thermal current (ith) for ambient temperature 60 c (140 f) a 10 frequency of ope rational current hz 25 to 400 minimum switching capacity u min. v 17 i min. ma 5 short-circuit protection k conforming to iec 60947-5-1 and vde 0660. gg fuse a 10 rated maki ng capacity conforming to iec 60947-5-1, i rms a ac: 140; dc: 250 short-time rating permissible for: 1 s a 100 500 ms a 120 100 ms a 140 insulation resistance m ? > 10 non-overlap time guaranteed between n.c. and n.o. contacts ms 1.5 (on energizing and on de-energizing) overlap time guaranteed between n.c. and n.o. on ladc22 ms 1.5 ? ? ? time delay (ladt, r and s contact blocks) accuracy only valid for setting range indicated on the front face ambient air temperature for operation c ? - 40 to + 70 (- 104 to + 158 f) - 40 to + 70 (- 104 to + 158 f) ? repeat accuracy ? 2% 2% ? drift up to 0.5 million op erating cycles ? + 15% + 15% ? drift depending on ambient air temperature ? 0.25% per c 0.25% per c ? mechanical durability in millions of operating cycles 30 5 5 30 operational power of contacts see page 101. k select short circuit protection to meet the national electrical code or other local codes and standards. catalog number: pages 107, 108 dimensions: pages 122, 123 schematics: pages 126, 127
tesys? d-line contactors and starters characteristics of auxiliary c ontacts, timers, and accessories 101 01/04 ? 2001-2004 schneider electric all rights reserved auxiliary contact bl ocks with dust and damp prot ected contacts for contactors operational power of contacts (conforming to iec 60947-5-1) ac supply, categories ac-14 and ac-15 electrical durability (valid up to 3600 op erating cycles/hour) on an indu ctive load such as the coil of an electr omagnet: makin g power (cos ? 0.7) = 10 times the power broken (cos ? 0.4) v 24 48 115 230 400 440 600 1 million operating cycles va 60 120 280 560 960 1050 1440 3 million operating cycles va 16 32 80 160 280 300 420 10 million operating cycles va 4 8 20 40 70 80 100 dc supply, category dc-13 electrical durability (valid up to 1200 oper ating cycles/hour) on an indu ctive load such as the coil of an electromagnet, witho ut economy resistor, the time constant increasing with the power. v 2448125250440 1 million operating cycles w 120 90 75 68 61 3 million operating cycles w 70 50 38 33 28 10 million operating cycles w 25 18 14 12 10 catalog number: pages 107, 108 dimensions: pages 122, 123 schematics: pages 126, 127 current broken in a 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1234 5 6 7 8 9 10 0.1 0.2 0.3 0.4 0.6 0.5 0.8 0.7 7 1 2 3 5 4 6 8 1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1234 5 6 7 8 9 10 0.1 0.2 0.3 0.4 0.6 0.5 0.8 0.7 7 1 2 3 5 4 6 8 1 440 v 48 v 250 v 125 v 24 v current broken in a
tesys? d-line contact ors and starters characteristics of auxiliary contacts, timers, and accessories ? 2001-2004 schneider electric all rights reserved 102 01/04 auxiliary contact blocks with dust and damp protected contacts for contactors environment contact block type la1dx la1dz la1dy protected non protected conforming to standards meets the essential requirements of the lv & emc directives iec 60947-5-1, vde 0660 product certifications ul, csa protective treatment conforming to iec 60068 ?th? degree of protection conforming to vde 0106 protection against direct finger contact ip 2x ambient air temperature storage and operation c - 25 to + 70 (- 77 to + 158 f) cabling phillips n 2 and ? 6 mm flexible or solid cable with or without cable end mm 2 min.: 1 x 1 max.: 2 x 2.5 number of contacts 222 2 contact characteristics rated operational voltage (ue) up to v 50 50 690 24 rated insulation voltage (ui) conforming to iec 60947-5-1 v 250 250 690 250 conforming to ul, csa v ??600 ? conventional thermal current (ith) for ambient temperature 40 c (104 f) a ??10 ? maximum operational current (ie) ma 50 50 10 50 frequency of operational current hz ? ? 25 to 400 ? minimum switch ing capacity u min. v 3317 3 i min. ma 0.3 0.3 5 0.3 short-circuit protection k conforming to iec 60947-5-1. gg fuse a ??10 ? rated making capacity conforming to iec 60947-5-1, i rms a ? ? ac: 140; dc: 250 ? short-time rating permissible for: 1 s a ??100 ? 500 ms a ??120 ? 100 ms a ??140 ? insulation resistance m ? > 10 > 10 > 10 > 10 mechanical durability in millions of operating cycles 5 5 30 5 materials and technology used for dust and damp protected contacts gold - single break with crossed bars gold - single break with crossed bars ? gold - single break with crossed bars k select short circuit protection to meet the national electrical code or other local codes and standards. catalog number: pages 107, 108 dimensions: pages 122, 123 schematics: pages 126, 127
tesys? d-line contactors and starters characteristics of auxiliary c ontacts, timers, and accessories 103 01/04 ? 2001-2004 schneider electric all rights reserved interface modul es for contactors environment conforming to standards meets the essential requirements of the lv & emc directives iec 60255-5 product certifications ul, csa protective treatment conforming to iec 60068 ?th? degree of protection conforming to vde 0106 protection against direct finger contact ip 2x ambient air temperature around the device storage c - 40 to + 80 (- 104 to + 176 f) operation c - 25 to + 55 (- 77 to + 131 f) permissible for operation at uc c - 25 to + 70 (- 77 to + 158 f) other characteristics module type la4dfbq la4dfb la4dfe la4dlb la4dle la4dwb with relay with relay with relay with relay + override solid state rated insulation voltage conforming to iec 60947-1 v 5250 rated operational voltage conforming to iec 60947-1 v 415 250 indication of input state by integral led which illuminates when the contactor coil is energized input signals control voltage (e1-e2) v dc 24 dc 24 dc 48 dc 24 dc 48 dc 24 permissible variation v 17 to 30 17 to 30 33 to 60 17 to 30 33 to 60 5 to 30 current consumption at 20 c (68 f) ma 25 25 15 25 15 8.5 for 5 v 15 for 24 v state ?0? guaranteed for u v < 2.4 < 2.4 < 4.8 < 2.4 < 4.8 < 2.4 i ma < 2 < 2< 1.3< 2< 1.3< 2 state ?1? guaranteed for u v 17 17 33 17 33 5 built-in protection against reverse polarity by diode of the input by diode electrical durability at 220/240 v in millions of oper ating cycles 3 10 10 3 3 20 maximum immunity time to micro-breaks ms 4 44441 power dissipated at 20 c (68 f) w 0.6 0.6 0.6 0.6 0.6 0.4 direct mounting without contactor with coil: ac 24 to 250 v ? lc1d40 to d150 ? ac 100 to 250 v ? ? lc1d40 to d115 ac 380 to 415 v lc1d40 to d150 ?? mounting with cabling adaptor lad-4bb with coil: ac 24 to 250 v ? lc1d09 to d38, dt20 to dt60 lc1d09 to d38, dt20 to dt60 ac 380 to 415 v lc1d09 to d38, dt20 to dt40 ?? total operating time at uc (of the contactor) operating times depend on the type of contactor electromagnet and its control mode. the closing time ?c? is measured from the moment the coil supply is switched on to initial contact of the main poles. the openi ng time ?o? is measured from the moment the coil supply is swit ched off to the moment the main poles separate. lc1d09 to d38, dt20 to dt60 lc1d40 to d65 lc1d80 and d95 with la4df, dl n.o. ms 20 to 30 28 to 34 28 to 43 n.c. ms 16 to 24 20 to 24 18 to 32 cabling phillips n 2 and ? 6 mm flexible or solid cable with or without cable end mm 2 min.: 1 x 1 (#12 awg) mm 2 min.: 2 x 2.5 (#12 awg) catalog number: page 111 dimensions: pages 122, 123 schematics: pages 126, 127
tesys? d-line contact ors and starters characteristics of auxiliary contacts, timers, and accessories ? 2001-2004 schneider electric all rights reserved 104 01/04 electronic serial timer modules for contactors environment module type la4dt (on-delay) conforming to standards meets the essential requirements of the lv & emc directives iec 60255-5 product certifications ul, csa protective treatment conforming to iec 60068 ?th? degree of protection conforming to vde 0106 protection against direct finger contact ip 2x ambient air temperature around the device storage c - 40 to + 80 (- 104 to + 176 f) operation c - 25 to + 55 (- 77 to + 131 f) for operation at uc c - 25 to + 70 (- 77 to + 158 f) rated insulation voltage (ui) conforming to iec 60947-1 v 250 cabling phillips n 2 and ? 6 mm flexible or solid cable with or without cable end mm 2 min.: 1 x 1 max.: 2 x 2.5 control circuit characteristics built-in protection on input by varistor suppression of contactor by varistor rated control circuit voltage (uc) v ac or dc 24 to 250 permissible variation 0.8 to 1.1 uc type of control by mechanical contact only time delay characteristics timing ranges s 0.1 to 2; 1.5 to 30; 25 to 500 repeat accuracy 0 to 40 c (104 f) 3% (10 ms minimum) reset time during the time delay period ms 150 after the time delay period ms 50 immunity to micro-breaks during the time delay period ms 10 after the time delay period ms 2 indication of time delay by led illuminates during time delay period switching characteristics (solid state type) maximum power dissipated w 2 leakage current ma < 5 residual voltage v 3.3 overvoltage protection 3 kv; 0.5 n ? m electrical durability in millions of operating cycles 30 operating diagrams la4dt ?on-delay? electronic timers u supply (a1-a2) time delay output contactor coil red led catalog number: page 111 dimensions: pages 122, 123 schematics: pages 126, 127 0 1 0 1 t
tesys? d-line contactors and starters characteristics of auxiliary c ontacts, timers, and accessories 105 01/04 ? 2001-2004 schneider electric all rights reserved control modules, coil suppressor modules and mechanical latch blocks for contactors environment conforming to standards iec 60947-5-1 product certifications ul, csa protective treatment conforming to iec 60068 ?th? degree of protection conforming to vde 0106 protection against direct finger contact ip 2x ambient air temperature around the device storage c - 40 to + 80 (- 104 to + 176 f) operation c - 25 to + 55 (- 77 to + 131 f) permissible for operation at uc c - 25 to + 70 (- 77 to + 158 f) ?auto - man - stop? control modules recommendation the auto - man selector switch must only be operated with the start - stop (?o? ?i?) switch in position ?o? rated insulation voltage conforming to iec 60947-5-1 v 250 rated operational voltage conforming to iec 60947-5-1 v 250 protection against electric shocks kv 2 built-in protection contactor coil suppression by varistor indication by integral led illuminates when the contactor coil is energized electrical durability in operating cycles 20,000 coil suppressor modules module type la4da lad4rc la4db lad4t la4dc la4de lad4v type of protection rc circuit bidirectional peak limiting diode diode varistor rated control circuit voltage (uc) v ac 24 to 415 ac or dc 24 to 72 dc 12 to 250 ac or dc 24 to 250 maximum peak voltage 3 uc 2 uc uc 2 uc natural rc frequency 24/48 v hz 400??? 50/127 v hz 200 110/240 v hz 100??? 380/415 v hz 150??? mechanical latch blocks mechanical latch block type la6dk10 lad6k10 la6dk20 for mounting on contactor lc1d40 to d65, lp1d65 lc1d09 to d38, dt20 to dt60 lc1d80 to d150 lp1d80 and lc1d115 certification ul, csa ul, csa rated insulation voltage conforming to iec 60947-5-1 v 690 690 rated control circuit voltage ac 50/60 hz and dc v 24 to 415 24 to 415 power required for unlatching ac va 25 25 dc w 30 30 maximum operating rate in operating cycles/hour 1200 1200 on-load factor 10% 10% mechanical durability at uc in millions of operating cycles 0.5 0.5 catalog number: pages 108, 110 - 112 dimensions: pages 122, 123 schematics: pages 126, 127
tesys? d-line contact ors and starters selection of auxiliary contact blocks ? 2001-2004 schneider electric all rights reserved 106 01/04 selection of auxiliary contact blocks aaa la1-dx, dy, dz lad-n lad-c lad-n lad-8n lc1d lad-r lad-t lad-s2 lad-n10, n01 (for lc1-d40 through d95 only) la6-dk or lad-6k q q the la6dk cannot be utilized with lc1d09 through d38 tesys contactors.
tesys? d-line contactors and starters selection of auxiliary contact blocks 107 01/04 ? 2001-2004 schneider electric all rights reserved f for lc1d40 through lc1d95 only. q device with 4 shield bonding terminals. k mount on left side only of lc k d09 through d38 with ac coils. not allowed on lc k d09 through d38 with dc coils. l see page 126 for actual markings. instantaneous auxiliary contact blocks for connection by screw clamp terminals for use in normal operating environments clip-on mounting number of contacts per block (see table below for maximum number of contacts) composition catalog number weight lb (kg) front 1 ???1? ladn10 f 0.04 (0.020) ????1 ladn01 f 0.04 (0.020) 2 ???11 ladn11 0.07 (0.030) ???2? ladn20 0.07 (0.030) ????2 ladn02 0.07 (0.030) 4 ???22 ladn22 0.11 (0.050) ???13 ladn13 0.11 (0.050) ???4? ladn40 0.11 (0.050) ????4 ladn04 0.11 (0.050) ???31 ladn31 0.11 (0.050) 4 includes one n.o. and one n.c. make before break ? ? ? 2 2 ladc22 0.11 (0.050) side 2 ???11 lad8n11 k 0.07 (0.030) ???2? lad8n20 k 0.07 (0.030) ????2 lad8n02 k 0.07 (0.030) for terminal referencing conforming to standard en 50012 l front, on 3p contactors & 4p contactors 20 to 60a 2 ???11 ladn11g 0.07 (0.030) 4 ???22 ladn22g 0.11 (0.050) front, on 4p contactors 80 to 200a 2 ???11 ladn11p 0.07 (0.030) 4 ???22 ladn22p 0.11 (0.050) with dust and damp protected terminals, for use in particularly harsh industrial environments front 2 ?2?? la1dx20 0.09 (0.040) 2???? la1dx02 0.09 (0.040) ?22?? la1dy20 q 0.09 (0.040) 4 ?2?2? la1dz40 0.11 (0.050) ?2?11 la1dz31 0.13 (0.060) instantaneous auxiliary contact blocks for connection by ring-tongue connectors this type of connection is not possible for blocks with dust and damp protected contacts. for all other instantaneous auxiliary contact blocks, add the digit 6 to the end of the references selected above. example: ladn10 becomes ladn106 . instantaneous auxiliary contact blocks for connection by spring terminals this type of connection is not possible for lad8, ladn with 1 contact or blocks with dust and damp protected contacts. for all other contact blocks, add the digit 3 to the end of the references selected above. example: ladn11 becomes ladn113 . instantaneous auxiliary contact blocks for connection by faston connectors this type of connection is not possible for lad8, ladn with 1 c ontact or blocks with dust and da mp protected contacts. for all other contact blocks, add the digit 9 to the end of the references selected above. example: ladn11 becomes ladn119 . maximum number of auxiliary contacts contactors instantaneous auxiliary contact blocks time delay front mounted side mounted front mounted type number of poles and size 1 contact 2 contacts 4 contacts ac 3p lc1d09 to d38 1 on left-hand side and ?1 or 1or 1 lc1d40 to d95 (50/60 hz) 1 on each side or 2 and 1 or 1 or 1 lc1d40 to d95 (50 or 60 hz) 1 on each side and 2 and 1 or 1 or 1 lc1d115 and d150 1 on left-hand side and ? 1 or 1 or 1 4p lc1dt20 to dt40 1 on left-hand side and ?1 or 1or 1 lc1d65 and d80 1 on each side or 1 or 1 or 1 or 1 lc1d115 1 on each side and 1 or 1 or 1 or 1 dc 3p lc1d09 to d38 ? ? 1 or 1 or 1 lc1d40 to d95 ? 1 or 1 or 1 or 1 lc1d115 and d150 1 on left-hand side and ? 1 or 1 or 1 4p lc1dt20 to dt40 1 on left-hand side or ?1 or 1or 1 lp1d65 and d80 ? 2 and 1 or 1 or 1 lc1d115 1 on each side ? and 1 or 1 or 1 lc (1) 3p lc1d09 to d38 ? ? 1 (2) ? ? 4p lc1dt20 to dt40 1 on left-hand side and ?1 or 1or 1 (1) lc: low consumption. (2) except ladn02. in order to mount on an lad8n on an lc1d40 to d95, a set of shims must be ordered separately, see page 114. characteristics: page 100-102 dimensions: pages 122, 123 schematics: pages 126, 127
tesys? d-line contact ors and starters selection of time-delay blocks, and mechanical-latch blocks ? 2001-2004 schneider electric all rights reserved 108 01/04 selection of time-delay blocks, and mechanical-latch blocks time delay auxiliary contact blocks for connection by screw clamp terminals maximum number of auxiliary contact blocks that can be attached per contactor, see page 107. sealing cover to be ordered separately, see page 114. ladt0 and ladr0: with extended scale from 0.1 to 0.6 s. lads2: with switching time of 40 ms 15 ms between opening of the n.c. contact and closing of the n.o. contact. clip-on mounting number of contacts time delay catalog number weight lb (kg) type setting range front 1 n.o. + 1 n.c. on-delay f 0.1 to 3 s ladt0 (0.13) 0.060 0.1 to 30 s ladt2 (0.13) 0.060 10 to 180 s ladt4 (0.13) 0.060 1 to 30 s lads2 (0.13) 0.060 off-delay f 0.1 to 3 s ladr0 (0.13) 0.060 0.1 to 30 s ladr2 (0.13) 0.060 10 to 180 s ladr4 (0.13) 0.060 f also fit pre-tesys contactors. time delay auxiliary contact blocks for connection by ring-tongue connectors add the digit 6 to the end of the references selected above. example: ladt0 becomes ladt06 . time delay auxiliary contact blocks for connection by spring terminals add the digit 3 to the end of the references selected above. example: ladt0 becomes ladt03 . time delay auxiliary contact blocks for connection by faston connectors add the digit 9 to the end of the references selected above. example: ladt0 becomes ladt09 . mechanical latch blocks (2) clip-on mounting unlatching control for use on contactor basic reference. complete with code indicating control voltage standard voltages (1) weight lb (kg) front manual or electric lc1d40 to d65 3p ac or dc lc1d65 4p ac lp1d65 4p dc la6dk10 ? b e f m q (0.15) 0.070 lc1d80 to d150 3p ac lc1d80 and d115 3p dc lp1d80 and lc1d115 4p c la6dk20 ? b e f m q (0.20) 0.090 lc1d09 to d38 ac or dc lc1dt20 to dt60 ac or dc lad6k10 ? b e f m q (0.15) 0.070 (1) standard control circuit voltages (for other vo ltages please consult your regional sales office). vdc 50/60 hz, 24 32/36 42/48 60/72 100 110/127 220/240 256/277 380/415 code bc e enkf mu q (2) the mechanical latching block must not be powered up at the same time as the contactor. the duration of the control signal f or the mechanical latching block and the contactor should be 100 ms. characteristics: pages 100 - 102 dimensions: pages 122, 123 schematics: pages 126, 127 seriplex ? module approvals file e114926 ccn nraq lr53531 class 2252 01 seriplex 1 block per contactor clip-on front mounting operates coils up to catalog number weight ? lb (kg.) contactor adaptor module f lc1d09 to lc1d80 277 vac la4spx 0.160 (0.072) lp1d09 to lp1d80 24 vdc f for more information, refer to seriplex catalog 8330ct9601. q attaches similarly to all other accessories. ladt k la6dk kk ladt k 3 la6dk kk la4spx q
tesys? d-line contactors and starters selection of low voltage ride through module 109 01/04 ? 2001-2004 schneider electric all rights reserved 1.9 (47) lad4bb e1 e2 a1 a2 ladlvr t e2 e1 a2 a2 a1 a1 1.3 (32) ladlvr t a1 a1 a2 a2 l1 l2 e1 14 13 e2 la9d941 ladlvrt*** lc1d09e32 lc1d40e80* do not connect 1.77 45 1.67 42.4 1.51 38.4 1.84 46.8 1.08 27.5 typical wiring scheme for 3-wire control dimensions contactors 40 a - 80 a contactors 32 a and less selection of low voltage ride through module semi f47 low voltage ride through module by ensuring semi f47 compliance of ac powered iec contactors and relays, the low voltage ride through modules can be used to increase the voltage sag immunity of semiconductor processing equipment. these modules make it possible for ac powered telemecanique contactors and relays to exceed the requirements of semi f47, both in the magnitude and duration of a voltage sag event ? even with accessories such as auxiliary contact blocks and pneumatic timers. more and more wafer fabs are insisting that front-end wafer processing equipment comply with semi f47. many of the contactors a nd pilot relays used on equipment, particularly in the emo circuit, are not able to meet the standard. as a result, equipment can drop out during a voltage sag of 50% in magnitude and 200ms in duration, causing equipment shutdown. the low voltage ride through modules can be used with telemecanique contactors from 9a through 80a, as well as the cad series of control relays. selection ladlvrt24v ladlvrt120v ladlvrt208v bracket fuse for use on lc1: d09b7, d12b7, d18b7, d25b7 for use on lc1: d09g7, d12g7, d18g7, d25g7 for use on lc1: d09le7, d12le7, d18le7, d25le7 lad4bb* la9d941 d32b7, d40b7, d50b7, d65b7, d80b7 d32g7, d40g7, d50g7, d65g7, d80b7 d32le7, d40l7, d50l7, d65l7, d80b7 - cadxxxb7 cadxxxg7 cadxxxle7 - * the low voltage ride through module can be used with all tesys control relays with 24 vac, 120 vac or 208 vac dual frequency coils. ** lad4bb must be used when the low voltage ride through module is being used with contactors 32 a and less, and tesys cad series of control relays. specifications continuous operating voltage range and line frequency 85?110% of the rated voltage at 47?63 hz max. installed accessories 1 front mount and 1 side mount auxiliary device for contactors 1 auxiliary device for tesys control relays dropout time 150 ms max. operation rate 20 operations/min. for lc1d09?lc1d32 30 operations/min. for lc1d40?lc1d80 max. mechanical and electrical durability 250 000 operations leakage current capability 6 ma maximum as per iec 61131 mtbf 100,000 hours standards semi f47-0999, culus, ce, ul 508 iec 60947-5-1 (control circuit devices and switching elements) iec 60068 (mechanical environmental testing) nsta (shipping and handling) iec 61000-4-2 electrostatic discharge iec 61000-4-3 electromagnetic field iec 61000-4-4 fast transient and burst iec 61000-4-5 surge immunity iec 61000-4-6 conducted rfi iec 60068-2-6 operational vibration iec 60068-2-27 operational shock pickup performance per ul508 and iec 60947 storage temperature -40 to +80 c (- 104 to + 176 f) operating temperature 0 to 40c (32 to 104 f) ambient surrounding ride through module relative humidity 5 to 95%, at 40c (104 f) non-condensing maximum operating altitude 3000 meters (9842.4 ft) 90 80 70 60 50 40 30 20 10 0 0.00 100.00 200.00 300.00 400.00 500.00 600.00 duration (msec) curves extend to 1000 ms must not drop out above this line semi ride through standard contactor must drop out contactor must ride through (initial condition = nominal voltage) must drop out below this line percent rated control v oltage
tesys? d-line contact ors and starters selection of electronic timers and interface modules ? 2001-2004 schneider electric all rights reserved 110 01/04 selection of electronic timers and interface modules **see cabling accessories page 114. la4-dt la4-df lc1-d09 to d38 (ac only) lc1dt20 to dt40 (ac only) la4-dl lad-4bb ** la4-dw la4-dm
tesys? d-line contactors and starters selection of electronic timers and interface modules 111 01/04 ? 2001-2004 schneider electric all rights reserved q electronic se rial timer modules (1) k 3-pole contactors lc1d40 to d150 and 4-pole contactors lc1d65 to d115: mounted directly across terminals a1 and a2 of contactor (screw mounting). on-delay type operational voltage time catalog number weight lb (kg) ac 24 to 250 v 100 to 250 v lc1 d09 to d38 (3p) and dt20 to dt60 (4p) lc1 d40 to d150 (3p) 0.1 to 2 s la4dt0u (2) 0.09 (0.040) 1.5 to 30 s la4dt2u (2) 0.09 (0.040) 25 to 500 s la4dt4u (2) 0.09 (0.040) interface modules k 3-pole contactors lc1d40 to d150 and 4-pole contactors lc1d65 to d115: mounted directly across terminals a1 and a2 of contactor ( screw mounting). relay interface operational voltage supply voltage e1-e2 (dc) catalog number weight lb (kg) ac 24 to 250 v ac 380 to 415 v ? lc1d09 to d150 (3p) and dt20 to dt60 (4p) 24 v la4dfbq (2) 0.12 (0.055) lc1d09 to d150 (3p) and dt20 to dt60 (4p) ?24 v la4dfb (2) 0.11 (0.050) 48 v la4dfe (2) 0.11 (0.050) relay interface with manual override switch (output forced ?on?) operational voltage supply voltage e1-e2 (dc) catalog number weight lb (kg) ac 24 to 250 v ac 100 to 250 v lc1d09 to d150 (3p) and dt20 to dt60 (4p) ?24 v la4dlb (2) 0.10 (0.045) 48 v la4dle (2) 0.10 (0.045) solid state interface lc1d09 to d38 (3p) and dt20 to dt60 (4p) lc1d40 to d115 (3p) 24 v la4dwb (2) 0.10 (0.045) auto-man-stop control modules for local override operation tests with two- position ?auto-man? switch and ?o-i? switch k 3-pole contactors lc1d40 to d150 and 4-pole contactors lc1d65 to d115: mounted directly across terminals a1 and a2 of contactor (screw mounting). operational voltage catalog number weight lb (kg) ac 24 to 100 v ac 100 to 250 v lc1d09 to d150 (3p) and dt20 to dt60 (4p) ? la4dmk (2) 0.09 (0.040) ? lc1d40 to d150 (3p) la4dmu 0.09 (0.040) (1) for 24 v operation, the contactor must be fitted with a 21 v coil (code z7). see pages 117. (2) mounting these accessories to tesys lc1d09 through d38 ac controlled and lc1dt20 through dt40 ac controlled contactors requi res the use of the lad4bb adaptor. this adapter can not be used on tesys contactors with dc coils. characteristics: pages 103 - 105 dimensions: pages 122, 123 schematics: pages 126, 127
tesys? d-line contact ors and starters selection of coil suppressor modules ? 2001-2004 schneider electric all rights reserved 112 01/04 selection of coil suppressor modules rc circuits (resistor-capacitor) k effective protection for circuits highly sensitive to ?high frequency? interference. for use only in cases where the voltage is virtually sinusoidal, i.e. less than 5% total harmonic distortion. k voltage limited to 3 uc maximum and oscillating frequency limited to 400 hz maximum. k slight increase in drop-out time (1.2 to 2 times the normal time). mounting for use with contactor (1) type catalog number weight lb (kg) rating v ac v dc clip-on (3) d09 to d38 (3p) and dt20 to dt40 24 to 48 ? lad4rce 0.03 (0.012) 110 to 250 ? lad4rcu 0.03 (0.012) screw mounting(4) d40 to d150 (3p) and d40 to d115 (4p) 24 to 48 ? la4da2e 0.04 (0.018) 50 to 127 ? la4da2g 0.04 (0.018) 110 to 250 ? la4da2u 0.04 (0.018) 380 to 415 ? la4da2n 0.04 (0.018) varistors (peak limiting) k protection provided by limiting the transient voltage to 2 uc max. k maximum reduction of transient voltage peaks. k slight increase in drop-out time (1.1 to 1.5 times the normal time). clip-on (3) d09 to d38 (3p) (2) dt20 to dt40 24 to 48 ? lad4ve 0.03 (0.012) 50 to 127 ? lad4vg 0.03 (0.012) 110 to 250 ? lad4vu 0.03 (0.012) screw connection to the contactor coil terminals d40 to d115 (3p) and d40 to d115 (4p) 24 to 48 ? la4de2e 0.04 (0.018) 50 to 127 ? la4de2g 0.04 (0.018) 110 to 250 ? la4de2u 0.04 (0.018) screw connection of wire to the contactor coil terminals d40 to d115 (3p) and d40 to d115 (4p) ? 24 to 48 la4de3e 0.04 (0.018) ? 50 to 127 la4de3g 0.04 (0.018) ? 110 to 250 la4de3u 0.04 (0.018) diodes k no over voltage or oscillating frequency. k increase in drop-out time (6 to 10 times the normal time). k polarized component. screw mounting (4) d40 to d95 (3p) d40 and d80 (4p) ? 24 to 250 la4dc3u 0.04 (0.018) bidirectional peak limiting diode k protection provided by limiting the transient voltage to 2 uc max. k maximum reduction of transient voltage peaks. clip-on (3) d09 to d38 (3p) (2) 24 ? lad4tb 0.03 (0.012) dt20 to dt40 72 ? lad4ts 0.03 (0.012) screw mounting (4) d40 to d95 (3p) 24 ? la4db2b 0.04 (0.018) d40 and d80 (4p) 72 ? la4db2s 0.04 (0.018) d40 to d95 (3p) ? 24 la4db3b 0.04 (0.018) d40 and d80 (4p) ? 72 la4db3s 0.04 (0.018) (1) for satisfactory protection, a suppressor module must be installed across the coil of each contactor. (2) from lc1d09 to d38 and lc1dt20 to dt40, dc and low consumption 3-pole contactors are fitted with built-in suppression as sta ndard. (3) clipping-on makes the electrical connection. the overall size of the contactor remains unchanged. (4) mounting at the top of the contactor on coil terminals a1 and a2. characteristics: pages 100 - 102 dimensions: pages 122, 123 schematics: pages 126, 127 lad4 la4d
tesys? d-line contactors and starters selection of accessories for contactors and reversing contactors 113 01/04 ? 2001-2004 schneider electric all rights reserved selection of accessories for contactors and reversing contactors accessories for main pole and control connections description for use on contactors sold in lots of catalog number weight lb (kg) ac dc connectors for cable, sizes (1 connector) 4-pole 10 mm 2 (8 awg) d09, d12, dt20, dt25 d09, d12, dt20, dt25 1 lad92560 0.67 (0.030) 3-pole 25 mm 2 (4 awg) d09 to d38 d09 to d38 1 la9d3260 0.09 (0.040) 4-pole 25 mm 2 (4 awg) dt32 to dt40 dt32 to dt40 1 lad96060 0.13 (0.060) connectors for cable, sizes (2 connectors) 3-pole 120 mm 2 (250 mcm) d115, d150 d115, d150 1 la9d115603b 1.2 (0.560) 4-pole 120 mm 2 (250 mcm) d115 d115 1 la9d115604 1.6 (0.740) connector for lug type terminals (2 connectors) 3-pole d115, d150 d115, d150 1 la9d115503b 0.66 (0.300) 4-pole d115 d115 1 la9d115504 0.80 (0.360) protective covers for lug type terminals 3-pole (1) d115, d150 d115, d150 1 la9d115703 0.55 (0.250) 4-pole (1) d115, d150 d115, d150 1 la9d115704 0.66 (0.300) links for parallel connection of 2 poles d09 to d38 d09 to d38 10 la9d2561 0.13 (0.060) dt20 & dt25 (4p) dt20 & dt25 (4p) 10 la9d1261 0.03 (0.012) dt32 to dt40 (4p) dt32 to dt40 (4p) 10 lad96061 0.13 (0.060) d40 to d65 d40 to d65 2 la9d40961 0.05 (0.021) d80, d95 d80 2 la9d80961 0.13 (0.060) 3 poles (star connection) d09 to d38 d09 to d38 10 lad9p3 (2) 0.01 (0.005) d80, d95 d80 1 la9d80962 0.18 (0.080) 4 poles dt20 to dt40 dt20 to dt40 2 la9d1263 0.05 (0.024) d40 to d65 d40 to d65 2 la9d40963 0.15 (0.070) d80, d95 d80 2 la9d80963 0.22 (0.100) staggered coil connection ? d40 to d80 10 la9d09966 0.01 (0.006) control circuit take-off from main pole d40 to d65 d40 to d65 10 la9d6567 0.02 (0.010) d80, d95 d80 10 la9d8067 0.02 (0.010) spreaders for increasing the pole pitch to 45 mm d115, d150 d115, d150 3 gv7ac03 0.4 (0.180) (1) for 3-pole contactors: 1 set of 6 covers, for 4-pole contactors: 1 set of 8 covers. (2) separate connecting bar for connecting 2 poles in parallel. dimensions: pages 122, 123 schematics: pages 126, 127 la9d3260 la9d11550  la9d11560  l a9d11570  la9d80962
tesys? d-line contact ors and starters selection of accessories for contactors and reversing contactors ? 2001-2004 schneider electric all rights reserved 114 01/04 sets of contacts and arc chambers description for use on contactors catalog number weight lb (kg) set of contacts 3-pole lc1d115 la5d1158031 0.60 (0.260) lc1d150 la5d150803 0.60 (0.260) 4-pole lc1d115004 la5d115804 0.72 (0.330) arc chambers 3-pole lc1d115 la5d11550 0.87 (0.395) lc1d150 la5d15050b 0.87 (0.395) 4-pole lc1d115004 la5d115450b 1.03 (0.470) cabling accessories for adapting existing wiring to a new product lc1d09 to d38 and lc1dt20 to dt60 ac only without coil suppression lad4bb 0.04 (0.019) with coil suppression ac 24 to 48 v lad4bbve 0.03 (0.014) ac 50 to 127 v lad4bbvg 0.03 (0.014) ac 110 to 250 v lad4bbvu 0.03 (0.014) set of 63 a busbars for paralleling of contactors 2 contactors lc1d09 to d18 or d25 to d38 gv2g245 0.08 (0.036) 4 contactors lc1d09 to d18 or d25 to d38 gv2g445 0.17 (0.077) terminal block for supply to: one or more gv2g busbar sets gv1g09 0.09 (0.040) protection accessories description application sold in lots of catalog number weight lb (kg) miniature fuse holder 5 x 20 with 4 a-250 v fuse 1 la9d941 0.05 (0.025) sealing cover for ladt, ladr 1 la9d901 0.01 (0.005) safety cover preventing access to the moving contact carrier lc1d09 to d38 and dt20 to dt60 1 lad9et1 0.06 (0.026) lc1d40 to d65 1 lad9et2 0.03 (0.012) lc1d80 and d95 1 lad9et3 0.008 (0.004) lc1d115 and d150 1 lad9et4 0.008 (0.004) marking accessories description application sold in lots of catalog number weight lb (kg) sheet of 80 blank labels self-adhesive, 8 x 33 (1) contactors (excluding 4-pole lc1-d65 to d115) ladn (4 contacts), la6dk 10 lad21 0.04 (0.020) sheet of 80 blank labels self-adhesive, 8 x 12 (1) ladn (2 contacts), ladt, ladr, lrd 10 lad22 0.04 (0.020) sheet of 80 blank labels for marking using plotter or 8 x 33 engraver contactors (excluding 4-pole lc1d65 to d115) lad (4 contacts), la6dk 10 lad23 0.11 (0.050) sheet of 112 blank labels for marking using plotter or 8 x 12 mm engraver all products 35 lad24 0.44 (0.200) label holder snap-in, 8 x 22 mm 4-pole contactors lc1d65 and d80, la6dk 100 la9d92 0.002 (0.001) legend holder snap-in, 8 x 22 mm lc1do9 to d38 lc1dt20 to d40 lad k n (4 contacts) lad k t, l a d k r 100 lad90 0.002 (0.001) bag of 300 blank labels self-adhesive, 7 x 21 mm on holder la9d92 1 la9d93 0.002 (0.001) ?sis label? labe l creation software multi-language version (en, fr, ge) q 1 xby2u 0.13 (0.060) q system requirement: 486 processor or better; windows 95, 98 or nt 4.0 or better. mounting accessories mounting plate for replacement of lc1f115 or f150 by lc1d115 or d150 1 la9d730 0.80 (0.360) set of shims for fitting side mounting blocks lad8n on lc1d40 to d95 1 la9d511 0.04 (0.020) (1) these legends are for sticking onto the safety cover of the contactors or add-on block, if fitted. gv2g245 gv1g09 la9d941 lad9et  xby1u
tesys? d-line contactors and starters d-line voltage code table 115 08/04 ? 2001-2004 schneider electric all rights reserved d-line voltage code table d-line voltage code voltage frequency d-line (see notes at end of table) lc1d09 - d38 lc2d09 - d38 notes d1, d3 lc1d40 - d95 lc2d40 - d95 note d1 lc1d115 - d150 note d1, d2, d4 5 low consump dc al - - 12 50/60 j7 - - 50 - j5 - dc jd jd - low consump dc jl - - wide range dc -jw- 20 50/60 - z7 - 50 - z5 - 60 - z6 - dc - - - low consump dc zl - - 24 50/60 b7 b7 b7 50 - b5 b5 60 - b6 b6 40-400 - - - dc bd bd bd low consump dc bl - - wide range dc -bw- 36 50/60 cc7 - - dc cd cd cd wide range dc -cw- 42 50/60 d7 d7 d7 50 - d5 d5 60 - - - 48 50/60 e7 e7 e7 50 - e5 e5 60 - e6 e6 40-400 - - - dc ed ed ed low consump dc el - - wide range dc -ew- 60 50/60 ee7 - - dc nd nd nd 72 dc sd sd sd low consump dc sl - - wide range dc -sw- 96 low consump dc dl - - 100 50/60 k7 k7 - dc - - - 110 50/60 f7 f7 f7 50 - f5 f5 60 - f6 f6 40-400 - - - dc fd fd fd low consump dc fl - - wide range dc -fw- 110/127 40-400 - - - 115 50/60 fe7 fe7 fe7 50 - fe5 fe5 40-400 - - - 120 50/60 g7 g7 g7 50 - - - 60 - g6 g6 40-400 - - - dc - - - low consump dc --- 125 dc gd gd gd 127 50/60 fc7 - fc7 60 - g5 fc5 40-400 - - - 155 dc pd - - 174 dc - - - 200 50/60 l7 l7 - dc - - - 200/208 50/60 - - - 60 - - - 40-400 - - - 208 50/60 le7 le7 le7 60 - l6 l6 40-400 - - - 220 50/60 m7 m7 m7 50 - - m5 60 - m6 m6 40-400 - - - dc md md md low consump dc ml - - wide range dc -mw- 220/230 50/60 - - - 50 - m5 - 60 - - - 40-400 - - - dc - - - 220/240 40-400 - - - dc - - - d-line voltage code (continued) voltage frequency d-line (see notes at end of table) lc1d09 - d38 lc2d09 - d38 notes d1, d3 lc1d40 - d95 lc2d40 - d95 note d1 lc1d115 - d150 note d1, d2, d4
tesys? d-line contact ors and starters d-line voltage code table ? 2001-2004 schneider electric all rights reserved 116 08/04 230 50/60 p7 p7 p7 50 u7 p5 p5 60 - - - 40-400 - - - dc - - - 230/240 50/60 - - - 240 50/60 u7 u7 u7 50 - u5 u5 60 - u6 u6 40-400 - - - dc - - - 250 dc ud ud ud low consump dc ul - - 256 50/60 - - - 50 - w5 - 277 50/60 w7 - ue7 50 - w6 w6 40-400 - - - 380 50/60 q7 q7 q7 50 - - q5 60 - q6 q6 40-400 - - - 380/400 50/60 - - - 50 - q5 - 60 - - - 40-400 - - - dc - - - 380/440 40-400 - - - 400 50/60 v7 v7 v7 50 - v5 v5 40-400 - - - 400/415 50/60 - - - 415 50/60 n7 n7 n7 50 - n5 n5 40-400 - - - 415-440 50 - - - 40-400 - - - 440 50/60 r7 r7 r7 50 - r5 r5 60 - r6 r6 40-400 - - - dc rd rd rd 440/460 dc - - - 460/480 60 - - - 480 50/60 t7 - t7 50 - - - 60 - t6 t6 40-400 - - - 500 50/60 s7 - s7 50 - s5 s5 40-400 - - - 575 50/60 sc7 - - 60 - s6 - d-line voltage code (continued) voltage frequency d-line (see notes at end of table) lc1d09 - d38 lc2d09 - d38 notes d1, d3 lc1d40 - d95 lc2d40 - d95 note d1 lc1d115 - d150 note d1, d2, d4 600 50/60 x7 - - 60 x6 x6 - 40-400 - - - 660 50 y5 y5 - 60 - - - 660/690 50/60 - - - notes: d1 for operating ranges refer to technical data section of the d-line contactors. ranges vary as a function of the current rating of the contactor and type of supply (ac/dc) d2 lc1-d150 contactors utilize dual frequen cy 50/60 hz. coils only. single frequency coils are not available. d3 lc1d09 -lc1d38 contactors with dc coil have integral suppression device (bi-directional diode) as standard. d4 d115 and d150 coils have integral suppression device fitted as standard. d-line voltage code (continued) voltage frequency d-line (see notes at end of table) lc1d09 - d38 lc2d09 - d38 notes d1, d3 lc1d40 - d95 lc2d40 - d95 note d1 lc1d115 - d150 note d1, d2, d4
tesys? d-line contactors and starters selection of ac coils 117 01/04 ? 2001-2004 schneider electric all rights reserved selection of ac coils ac coils for contactors lc1d09 to d3 8 3-pole and 4-pole lc1dt20 to dt40 specifications control circuit voltage uc average resistance at 20 c 10% inductance of closed ci rcuit catalog number (1) weight lb (kg) v ? h50/60 hz average consumption at 20 c (68 f): - inrush (cos ? = 0.75) 70 va, - sealed (cos ? = 0.3) 50 hz: 7 va, 60 hz: 7.5 va. operating range ( 60 c / 140 f): 50 hz: 0.8 to 1.1 uc, 60 hz: 0.85 to 1.1 uc. 12 6.3 0.26 lxd1j7 0.15 (0.070) 21 (2) 5.6 0.24 lxd1z7 0.15 (0.070) 24 6.19 0.26 lxd1b7 0.15 (0.070) 32 12.3 0.48 lxd1c7 0.15 (0.070) 36 12.83 lxd1cc7 0.15 (0.070) 42 19.15 0.77 lxd1d7 0.15 (0.070) 48 25 1 lxd1e7 0.15 (0.070) 60 34.6 ? lxd1ee7 0.15 (0.070) 100 100.4 ? lxd1k7 0.15 (0.070) 110 130 5.5 lxd1f7 0.15 (0.070) 115 129.8 ? lxd1fe7 0.15 (0.070) 120 159 6.7 lxd1g7 0.15 (0.070) 127 192.5 7.5 lxd1fc7 0.15 (0.070) 200 410.7 ? lxd1l7 0.15 (0.070) 208 417 16 lxd1le7 0.15 (0.070) 220 539 22 lxd1m7 0.15 (0.070) 230 595 21 lxd1p7 0.15 (0.070) 240 645 25 lxd1u7 0.15 (0.070) 277 781 30 lxd1w7 0.15 (0.070) 380 1580 60 lxd1q7 0.15 (0.070) 400 1810 64 lxd1v7 0.15 (0.070) 415 1938 74 lxd1n7 0.15 (0.070) 440 2242 79 lxd1r7 0.15 (0.070) 480 2300 85 lxd1t7 0.15 (0.070) 575 3432 119 lxd1sc7 0.15 (0.070) 600 3600 135 lxd1x7 0.15 (0.070) 690 5600 190 lxd1y7 0.15 (0.070) (1) the last two digits of the reference represent the voltage code. (2) voltage for special coils installed in contacto rs with serial timer modules, with 24 v supply. lxd1 k
tesys? d-line contact ors and starters selection of ac coils ? 2001-2004 schneider electric all rights reserved 118 01/04 ac coils for 3 or 4-pole contactors lc1d40, d50, d65, d80, d95 specifications control circuit voltage uc average resistance at 20 c 10% inductance of closed circuit catalog number (1) average resistance at 20 c 10% inductance of closed circuit catalog number (1) weight lb (kg) v ? h 50 hz w h 60 hz average consumption at 20 c (68 f): - inrush (cos ? = 0.75) 50 hz: 200 va, 60 hz: 220 va, - sealed (cos ? = 0.3) 50 hz: 20 va, 60 hz: 22 va. operating range ( 55 c / 131 f): 0.85 to 1.1 uc. 24 1.4 0.09 lx1d6b5 1.05 0.06 lx1d6b6 0.61 (0.280) 32 2.6 0.16 lx1d6c5 ?? ? 0.61 (0.280) 42 4.4 0.27 lx1d6d5 ?? ? 0.61 (0.280) 48 5.5 0.35 lx1d6e5 4.2 0.23 lx1d6e6 0.61 (0.280) 110 31 1.9 lx1d6f5 22 1.2 lx1d6f6 0.61 (0.280) 115 31 1.9 lx1d6fe5 ?? ? 0.61 (0.280) 120 ?? ? 28 1.5 lx1d6g6 0.61 (0.280) 127 41 2.4 lx1d6g5 ?? ? 0.61 (0.280) 208 ?? ? 86 4.3 lx1d6l6 0.61 (0.280) 220 ?? ? 98 4.8 lx1d6m6 0.61 (0.280) 220/230 127 7.5 lx1d6m5 ?? ? 0.61 (0.280) 230 133 8.1 lx1d6p5 ?? ? 0.61 (0.280) 240 152 8.7 lx1d6u5 120 5.7 lx1d6u6 0.61 (0.280) 256 166 10 lx1d6w5 ?? ? 0.61 (0.280) 277 ?? ? 157 8 lx1d6w6 0.61 (0.280) 380 ?? ? 300 14 lx1d6q6 0.61 (0.280) 380/400 381 22 lx1d6q5 ?? ? 0.61 (0.280) 400 411 25 lx1d6v5 ?? ? 0.61 (0.280) 415 463 26 lx1d6n5 ?? ? 0.61 (0.280) 440 513 30 lx1d6r5 392 19 lx1d6r6 0.61 (0.280) 480 ?? ? 480 23 lx1d6t6 0.61 (0.280) 500 668 38 lx1d6s5 ?? ? 0.61 (0.280) 575 ?? ? 675 33 lx1d6s6 0.61 (0.280) 600 ?? ? 775 36 lx1d6x6 0.61 (0.280) 660 1220 67 lx1d6y5 ?? ? 0.61 (0.280) specifications average consumption at 20 c (68 f): - inrush (cos ? = 0.75) 50/60 hz: 245 va at 50 hz, - sealed (cos ? = 0.3) 50/60 hz: 26 va at 50 hz. operating range ( 55 c / 131 f): 0.85 to 1.1 uc. 50/60 hz 24 ? ? ? 1.22 0.08 lx1d6b7 0.61 (0.280) 42 ???3.50.25 lx1d6d7 0.61 (0.280) 48 ???50.32 lx1d6e7 0.61 (0.280) 110 ???261.7 lx1d6f7 0.61 (0.280) 115 ????? lx1d6fe7 0.61 (0.280) 120 ???322 lx1d6g7 0.61 (0.280) 208 ???88.74.42 lc1d6le7 0.61 (0.280) 220/230 (2) ? ? ? 102 6.7 lx1d6m7 0.61 (0.280) 230 ? ? ? 115 7.7 lx1d6p7 0.61 (0.280) 230/240 (3) ? ? ? 131 8.3 lx1d6u7 0.61 (0.280) 380/400 (4) ? ? ? 310 20 lx1d6q7 0.61 (0.280) 400 ? ? ? 349 23 lx1d6v7 0.61 (0.280) 415 ? ? ? 390 24 lx1d6n7 0.61 (0.280) 440 ? ? ? 410 27 lx1d6r7 0.61 (0.280) (1) the last two digits of the reference represent the voltage code. (2) for use on 230 v 50 hz, apply a coefficient of 0.6 to the mechanical durability of the contactor (see page 82) . this coil can be used on 240 v at 60 hz. (3) this coil can be used on 220/240 v at 50 hz and on 240 v only at 60 hz. (4) for use on 400 v 50 hz, apply a coefficient of 0.6 to the mechanical durability of the contactor. lx1d6 k
tesys? d-line contactors and starters selection of ac coils 119 01/04 ? 2001-2004 schneider electric all rights reserved selection of ac coils ac coils for 3 or 4-pole contactors lc1d115 control circuit voltage uc average resistance at 20 c 10% inductance of closed circuit catalog number(1) average resistance at 20 c 10% inductance of closed circuit catalog number (1) weight lb (kg) v ? h50 hz ? h60 hzkg specifications average consumption at 20 c (68 f): - inrush (cos ? = 0.8) - 50 or 60 hz: 300 va, - sealed (cos ? = 0.3) - 50 or 60 hz: 22 va. operating range ( 55 c / 131f): 0.85 to 1.1 uc. 24 1.24 0.09 lx1d8b5 0.87 0.07 lx1d8b6 0.57 (0.260) 32 2.14 0.17 lx1d8c5 ?? ? 0.57 (0.260) 42 3.91 0.28 lx1d8d5 ?? ? 0.57 (0.260) 48 4.51 0.36 lx1d8e5 3.91 0.28 lx1d8e6 0.57 (0.260) 110 26.53 2.00 lx1d8f5 19.97 1.45 lx1d8f6 0.57 (0.260) 115 26.53 2.00 lx1d8fe5 ?? ? 0.57 (0.260) 120 ?? ? 24.02 1.70 lx1d8g6 0.57 (0.260) 127 32.75 2.44 lx1d8fc5 ?? ? 0.57 (0.260) 208 ?? ? 67.92 5.06 lx1d8l6 0.57 (0.260) 220 104.77 7.65 lx1d8m5 79.61 5.69 lx1d8m6 0.57 (0.260) 230 104.77 8.29 lx1d8p5 ?? ? 0.57 (0.260) 240 125.25 8.89 lx1d8u5 97.04 6.75 lx1d8u6 0.57 (0.260) 277 ?? ? 125.75 8.89 lx1d8w6 0.57 (0.260) 380 338.51 22.26 lx1d8q5 243.07 17.04 lx1d8q6 0.57 (0.260) 400 368.43 25.55 lx1d8v5 ?? ? 0.57 (0.260) 415 368.43 27.65 lx1d8n5 ?? ? 0.57 (0.260) 440 441.56 30.34 lx1d8r5 338.51 22.26 lx1d8r6 0.57 (0.260) 480 ?? ? 368.43 25.55 lx1d8t6 0.57 (0.260) 500 566.62 38.12 lx1d8s5 ?? ? 0.57 (0.260) for 3 or 4-pole contactors lc1d115, d150 specifications average consumption at 20 c (68 f): - inrush: cos ? = 0.9 - 280 to 350 va, - sealed: cos ? = 0.9 - 2 to 18 va. operating range ( 55 c / 131 f): 0.8 to 1.15 uc. coils with integral suppression device fitted as standard, class b. 50/60 hz 24 ? ? ? 147 3.03 lx1d8b7 0.64 (0.290) 32 ? ? ? 301 8.28 lx1d8c7 0.64 (0.290) 42 ? ? ? 498 13.32 lx1d8d7 0.64 (0.290) 48 ? ? ? 1061 24.19 lx1d8e7 0.64 (0.290) 110 ? ? ? 4377 109.69 lx1d8f7 0.64 (0.290) 115 ? ? ? 4377 109.69 lx1d8fe7 0.64 (0.290) 120 ? ? ? 4377 109.69 lx1d8g7 0.64 (0.290) 127 ? ? ? 6586 152.65 lx1d8fc7 0.64 (0.290) 208 ? ? ? 10 895 260.15 lx1d8le7 0.64 (0.290) 220 ? ? ? 9895 210.72 lx1d8m7 0.64 (0.290) 230 ? ? ? 9895 210.72 lx1d8p7 0.64 (0.290) 240 ? ? ? 9895 210.72 lx1d8u7 0.64 (0.290) 277 ? ? ? 21 988 533.17 lx1d8ue7 0.64 (0.290) 380 ? ? ? 21 011 482.42 lx1d8q7 0.64 (0.290) 400 ? ? ? 21 011 482.42 lx1d8v7 0.64 (0.290) 415 ? ? ? 21 011 482.42 lx1d8n7 0.64 (0.290) 440 ? ? ? 21 501 507.47 lx1d8r7 0.64 (0.290) 480 ? ? ? 32 249 938.41 lx1d8t7 0.64 (0.290) 500 ? ? ? 32 249 938.41 lx1d8s7 0.64 (0.290) (1) the last two characters of the reference represent the voltage code. lx1d8 kk
tesys? d-line contact ors and starters selection of dc coils ? 2001-2004 schneider electric all rights reserved 120 01/04 selection of dc coils dc coils for 3-pole contactors lc1d40 to d65 or 4-pole contactors lp1d65 control circuit voltage uc average resistan ce at 20 c 10% inducta nce of closed circuit catalog number (1) weight lb (kg) v ? h specifications average consumption: 22 w. operating range: 0.85 to 1.1 uc. 12 7.1 0.44 lx4d6jd 0.91 (0.415) 24 26.8 1.69 lx4d6bd 0.91 (0.415) 36 58 3.55 lx4d6cd 0.91 (0.415) 48 109 6.86 lx4d6ed 0.91 (0.415) 60 173 10.9 lx4d6nd 0.91 (0.415) 72 234 14.7 lx4d6sd 0.91 (0.415) 110 560 35.28 lx4d6fd 0.91 (0.415) 125 717 45.2 lx4d6gd 0.91 (0.415) 220 2255 142 lx4d6md 0.91 (0.415) 250 2940 185 lx4d6ud 0.91 (0.415) 440 9080 572 lx4d6rd 0.91 (0.415) for 3-pole contactors lc1d80 or 4-pole contactors lp1d80 specifications average consumption: 22 w. operating range: 0.85 to 1.1 uc. 12 6.6 0.46 lx4d7jd 1.50 (0.680) 24 27 1.89 lx4d7bd 1.50 (0.680) 36 57 4 lx4d7cd 1.50 (0.680) 48 107 7.5 lx4d7ed 1.50 (0.680) 60 170 11.9 lx4d7nd 1.50 (0.680) 72 230 16.1 lx4d7sd 1.50 (0.680) 110 564 39.5 lx4d7fd 1.50 (0.680) 125 718 50.3 lx4d7gd 1.50 (0.680) 220 2215 155 lx4d7md 1.50 (0.680) 250 2850 200 lx4d7ud 1.50 (0.680) 440 9195 640 lx4d7rd 1.50 (0.680) (1)1 the last two characters of the reference represent the voltage code. lx4d6 kk lx4d7 kk
tesys? d-line contactors and starters selection of dc coils 121 01/04 ? 2001-2004 schneider electric all rights reserved dc coils for 3 or 4-pole contactors lc1d115, d150 control circuit voltage uc average resistance at 20 c 10% inductance of closed circuit catalog number(1) weight lb (kg) v ? h specifications consumption: inrush 270 to 365 w, sealed 2.4 to 5.1 w. operating range: 0.7 to 1.2 uc. coils have integral suppression device as standard, class b. 24 147 3.03 lx4d8bd 0.66 (0.300) 48 1061 24.19 lx4d8ed 0.66 (0.300) 60 1673 38.44 lx4d8nd 0.66 (0.300) 72 2500 56.27 lx4d8sd 0.66 (0.300) 110 4377 109.69 lx4d8fd 0.66 (0.300) 125 6586 152.65 lx4d8gd 0.66 (0.300) 220 9895 210.72 lx4d8md 0.66 (0.300) 250 18 022 345.40 lx4d8ud 0.66 (0.300) 440 21 501 684.66 lx4d8rd 0.66 (0.300) (1) the last two characters of the reference represent the voltage code. wide range dc coils for 3-pole contactors lc1d40 to d65 or 4-pole contactors lp1 to d65 control circuit voltage uc average resistance at 20 c 10% inductance of closed circuit catalog number(1) weight lb (kg) v ? h specifications average consumption: 22 w. operating range: 0.75 to 1.2 uc. coils with ?th? treatment as standard. 12 6.8 0.45 lx4d6jw 0.91 (0.415) 24 30 1.9 lx4d6bw 0.91 (0.415) 36 53 3.5 lx4d6cw 0.91 (0.415) 48 110 7.2 lx4d6ew 0.91 (0.415) 72 215 14.2 lx4d6sw 0.91 (0.415) 110 580 38.3 lx4d6fw 0.91 (0.415) 220 2120 140 lx4d6mw 0.91 (0.415) for 3-pole contactors lc1d80 or 4-pole contactors lp1d80 specifications average consumption: 23 w. operating range: 0.75 to 1.2 uc. coils with ?th? treatment as standard. 12 6.2 0.49 lx4d7jw 1.50 (0.680) 24 23.5 1.75 lx4d7bw 1.50 (0.680) 36 51.9 4.18 lx4d7cw 1.50 (0.680) 48 94.2 7 lx4d7ew 1.50 (0.680) 72 204 15.7 lx4d7sw 1.50 (0.680) 110 483 36 lx4d7fw 1.50 (0.680) 220 1922 144 lx4d7mw 1.50 (0.680) (1) the last two characters of the reference represent the voltage code. lx4d8 k d lx4d6 kk
tesys? d-line contact ors and starters dimensions for type lc1d contactors ? 2001-2004 schneider electric all rights reserved 122 01/04 dimensions for type lc1d contactors d-line contactors ac control circuits x lc1d09 to d18 (3-pole) lc1d25 to d38 (3-pole) lc1dt20 to dt40 (4-pole) lc1 d09 to d093 to d099 to d25 to d253 dt20 dt203 dt32 to dt323 d18 d183 d189 d38 and d323 and dt25 and dt253 dt40 and dt403 b without add-on blocks 3.03 (77) 3.89 (99) 3.14 (80) 3.36 (85) 3.89 (99) 3.34 (85) 3.89 (99) 3.58 (91) 4.13 (105) b1 with lad4bb 3.70 (94) 4.21 (107) 3.75 (95.5) 3.85 (98) 4.21 (107) 3.85 (98) ? ? ? with la4d ? 2 4.33 (110) (1) 4.84 (123) (1) 4.30 (111.5) (1) 4.48 (114) (1) 4.84 (123) (1) 4.48 (114) ? ? ? with la4df, dt 4.68 (119) (1) 5.19 (132) (1) 4.76 (120.5) (1) 4.84 (123) (1) 5.19 (132) (1) 5.02 (129) ? ? ? with la4dr, dw, dl 4.96 (126) (1) 5.67 (139) (1) 5.0 (127.5) (1) 5.11 (130) (1) 5.47 (139) (1) 7.48 (190) ? ? ? c without cover or add-on blocks 3.30 (84) 3.30 (84) 3.30 (84) 3.54 (90) 3.54 (90) 3.54 (90) 3.54 (90) 3.85 (98) 3.85 (98) with cover, without add-on blocks 3.38 (86) 3.38 (86) 3.38 (86) 3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.93 (100) 3.93 (100) c1 with ladn or c (two or four contacts) 4.60 (117) 4.60 (117) 4.60 (117) 4.84 (123) 4.84 (123) 4.84 (123) 4.84 (123) 5.15 (131) 5.15 (13 1) c2 with la6dk10, lad6k10 5.07 (129) 5.07 (129) 5.07 (129) 5.31 (135) 5.31 (135) 5.31 (135) 5.31 (135) 5.62 (143) 5.62 (143) c3 with ladt, r, s 5.39 (137) 5.39 (137) 5.39 (137) 5.62 (143) 5.62 (143) 5.62 (143) 5.62 (143) 5.94 (151) 5.94 (151) with ladt, r, s and sealing cover 5.55 (141) 5.59 (141) 5.55 (141) 5.78 (147) 5.78 (147) 5.78 (147) 5.78 (147) 6.10 (155) 6.10 (155) (1) including lad4bb lc1d40 to d65 (3-pole) lc1d65004, d40008 and d65008 (4-pole) lc1d80 and d95 (3-pole) lc1d80004 and d80008 (4-pole) lc1 d40 to d65 d40008 d80 d95 d80004 d80008 d65004 d65008 a 2.95 (75) 3.34 (85) 3.34 (85) 3.34 (85) 96 96 b1 with la4d ? 2 5.31 (135) 5.31 (135) 5.31 (135) 5.31 (135) 5.31 (135) 5.31 (135) with la4db3 ? ? 5.31 (135) ? ? ? with la4df, dt 5.59 (142) 5.59 (142) 5.59 (142) 5.59 (142) 5.59 (142) 5.59 (142) with la4dm, dr, dw, dl 5.90 (150) 5.90 (150) 5.90 (150) 5.90 (150) 5.90 (150) 5.90 (150) c without cover or add-on blocks 4.72 (114) 4.92 (125) 4.92 (125) 4.92 (125) 4.92 (125) 5.51 (140) with cover, without add-on blocks 4.68 (119) ? 5.11 (130) 5.11 (130) ? ? c1 with ladn (one contact) 5.47 (139) 5.47 (139) 5.90 (150) 5.90 (150) 5.90 (150) 5.90 (150) with ladn or c (two or four contacts) 5.78 (147) 5.78 (147) 6.22 (158) 6.22 (158) 6.22 (158) 6.22 (158) c2 with la6dk 6.25 (159) 6.25 (159) 6.69 (170) 6.69 (170) 6.69 (170) 6.69 (170) c3 with ladt, r, s 6.57 (167) 6.57 (167) 7.00 (178) 7.00 (178) 7.00 (178) 7.00 (178) with ladt, r, s and sealing cover 6.73 (171) 6.73 (171) 7.16 (182) 7.16 (182) 7.16 (182) 7.16 (182) lc1d115 and d150 (3-pole) lc1d115004 (4-pole) lc1 d115 d115004 d115006 d150006 d1150046 d150 a 4.72 (120) 5.90 (150) 4.72 (120) 4.72 (120) 6.10 (155) b1 with la4da2 6.85 (174) 6.85 (174) 6.85 (174) 6.85 (174) 6.85 (174) with la4df, dt 7.28 (185) 7.28 (185) 7.28 (185) 7.28 (185) 7.28 (185) with la4dm, dr, dl 7.40 (188) 7.40 (188) 7.40 (188) 7.40 (188) 7.40 (188) with la4dw 7.40 (188) 7.40 (188) 7.40 (188) ? 7.40 (188) c without cover or add-on blocks 5.1?9 (132) 5.1?9 (132) 4.52 (115) 4.52 (115) 4.52 (115) with cover, without add-on blocks 5.35 (136) ? ? ? ? c1 with ladn or c (two or four contacts) 5.90 (150) 5.90 (150) 5.90 (150) 5.90 (150) 5.90 (150) c2 with la6dk20 6.10 (155) 6.10 (155) 6.10 (155) 6.10 (155) 6.10 (155) c3 with ladt, r, s 6.61 (168) 6.61 (168) 6.61 (168) 6.61 (168) 6.61 (168) with ladt, r, s and sealing cover 6.77 (172) 6.77 (172) 6.77 (172) 6.77 (172) 6.77 (172) selection: pages 142, 143 characteristics: pages 84, 85 schematics: pages 126, 127 b c c1 c2 c3 1.77 0.49 (lad-8) b1 1.73 la4 0.39 10 44 45 12.5 minimum electrical clearance b 1.77 (lad-8) b1 1.73 la4 c 0.39 c1 c2 c3 10 44 45 0.49 12.5 minimum electrical clearance b1 a 0.49 (lad-8) 0.49 (lad-8) c 0.47 c1 c2 c3 5.0 1.73 1.26 la4 12 127 12.5 12.5 32 44 minimum electrical clearance 0.47 5.0 b1 a 0.49 (lad-8) 0.49 (lad-8) 1.73 1.26 c c1 c2 c3 la4 12 127 12.5 12.5 32 44 minimum electrical clearance 6.22 c a c1 c2 c3 b1 lad-8 la4 0.39 158 10 minimum electrical clearance
tesys? d-line contactors and starters dimensions for type lc1d contactors 123 01/04 ? 2001-2004 schneider electric all rights reserved d-line contactors dc control circuit or low consumption lc1d09 to d18 (3-pole) lc1d25 to d38 (3-pole) lc1 d09 to d18 d093 to d183 d099 to d189 d25 to d38 d253 and d383 b 3.03 (77) 3.89 (99) 3.30 (80) 3.34 (85) 3.89 (99) c without cover or add-on blocks 3.66 (93) 3.66 (93) 3.66 (93) 3.89 (99) 3.89 (99) with cover, without add-on blocks 3.76 (95) 3.76 (95) 3.76 (95) 3.97 (101) 3.97 (101) c1 with ladn or c (two or four contacts) 4.96 (126) 4.96 (126) 4.96 (126) 5.19 (132) 5.19 (132) c2 with la6dk10 5.43 (138) 5.43 (138) 5.43 (138) 5.66 (144) 5.66 (144) c3 with ladt, r, s 5.76 (146) 5.76 (146) 5.76 (146) 5.98 (152) 5.98 (152) with ladt, r, s and sealing cover 5.90 (150) 5.76 (146) 5.76 (146) 6.14 (156) 6.14 (156) lc1dt20 to dt60 (4-pole) lc1 dt20 and dt25 d098 and d128 dt203 and dt253 d0983 and d1283 dt32 to dt40 d188 to d258 dt323 and dt403 d1883 and d2583 b 3.34 (85) 3.89 (99) 3.58 (91) 4.13 (105) c with cover 3.56 (90) 3.56 (90) 3.54 (98) 3.54 (98) c1 with ladn or c (two or four contacts) 4.84 (123) 4.84 (123) 5.15 (131) 5.15 (131) c2 with la6dk10 5.31 (135) 5.31 (135) 5.62 (143) 5.62 (143) c3 with ladt, r, s 5.62 (143) 5.62 (143) 5.94 (151) 5.94 (151) with ladt, r, s and sealing cover 5.78 (147) 5.78 (147) 6.10 (155) 6.10 (155) lc1d40 to d65 (3-pole lp1d65004, lp1d40008 to d65008 (4-pole) lc1d80 and d95 (3-pole) lp1d80004, lp1d80008 (4-pole) lc1 lp1d65004 lp1d40008 lc1 lp1 lp1 d40 to d65 and d65008 d80 and d95 d80004 d80008 c without cover or add-on blocks 6.73 (171) 6.73 (171) 7.46 (182) 7.40 (181) 7.40 (181) ? with cover, without add-on blocks 6.92 (176) ? ? 7.32 (186) ? 8.03 (204) c1 with ladn (1 contact) 7.71 (196) 7.71 (196) 7.71 (196) 8.03 (204) 8.03 (204) 8.26 (210) with ladn or c (2 or 4 contacts) 7.95 (202) 7.95 (202) 7.95 (202) 8.26 (210) 8.26 (210) 8.70 (221) c2 with la6dk10 8.38 (213) 8.38 (213) 8.38 (213) 8.70 (221) 8.70 (221) 9.01 (229) c3 with ladt, r, s 8.70 (221) 8.70 (221) 8.70 (221) 9.01 (229) 9.01 (229) 9.17 (233) selection: pages 92 characteristics: pages 80 - 87 schematics: pages 126, 127 c b 0.39 c1 c2 c3 1.77 10 45 minimum electrical clearance b c 0.39 c1 c2 c3 1.77 10 45 minimum electrical clearance c b 0.39 c1 c2 c3 1.77 45 10 minimum electrical clearance 3.35 c 0.47 c1 c2 c3 5.0 12 127 85 minimum electrical clearance 3.78 c 0.47 c1 c2 c3 5.0 12 127 96 minimum electrical clearance
tesys? d-line contact ors and starters mounting information for type lc1d and lp1d contactors ? 2001-2004 schneider electric all rights reserved 124 01/04 mounting information for type lc1d and lp1d contactors xx on mounting rail am1dp200, dr200 or am1de200 (width 35 mm) lc1d09 to d38, dt20 to dt60 on mounting rail am1dl200 or dl201 (width 75 mm) on mounting rail am1ed ??? or am1de200 (width 35 mm) lc1d40 to d95, lp1d40 to d80 ac control circuit lc1 d09 to d18 d25 to d38 dt20 and dt25 dt32 to dt40 lc1 d40 to d65 d80 and d95 c (am1dl200) (1) 5.35 (136) 5.78 (147) b 3.03 (77) 3.36 (85) 3.36 (85) 3.93 (100) c (am1dl201) (1) 4.96 (126) 5.39 (137) c (am1dp200 or dr200) (1) 3.46 (88) 3.70 (94) 3.70 (94) 4.29 (109) c (am1ed ??? or de200) (1) 4.96 (126) 5.39 (137) c (am1de200) (1) 3.77 (96) 4.01 (102) 4.01 (102) 4.60 (117) dc control circuit dc control circuit lc1 d40 to d65 d80 and d95 b 3.03 (77) 3.36 (85) 3.70 (94) 4.29 (109) c (am1dl200) (1) 7.59 (193) 7.99 (203) c (am1dp200 or dr200) (1) 3.81 (97) 4.05 (103) 4.05 (103) 4.64 (118) c (am1dl201) (1) 7.20 (183) 7.99 (203) c (am1de200) (1) 4.13 (105) 4.33 (110) 4.37 (111) 4.84 (123) lp1 d40 d65 d80 c (am1dl200) 7.40 (188) 7.40 (188) 7.78 (198) c (am1dl201) 7.00 (178) 7.00 (178) 7.78 (198) (1) with safety cover (1) with safety cover on two mounting rails dz5mb at 120 mm center lc1d115, d150 ac or dc control circuit lc1 d115 and d150 d1156 and d1506 c (am1dp200 or dr200) 134.5 117.5 c (am1de200 or ed kkk ) 142.5 125.5 on two mounting rails dz5mb at 120 mm center lc1d40 to d95, lp1d40 to d80 ac control circuit lc1 d40 to d65 d80 and d95 c with cover 4.70 (119) 5.11 (130) dc control circuit lc1 d40 to d65 d80 and d95 c with cover 6.92 (176) 7.32 (186) lp1 d40 and d65 d80 c 6.73 (171) 7.12 (181) selection: pages 88 characteristics: pages 80 - 87 schematics: pages 126, 127 c = b = 5.0 = = c 127 100 = = 158 c 110 120 40 c 15 dz5-me5
tesys? d-line contactors and starters mounting information for type lc1d and lp1d contactors 125 01/04 ? 2001-2004 schneider electric all rights reserved lc1d09 to d38 and lc1dt20 to dt60 on two mounting rails dz5mb control circuit: ac dc lc1 d09 to d18 d25 to d38 d09 to d18 d25 to d38 c with cover 3.38 (86) 3.62 (92) 3.76 (95) 3.97 (101) g 1.37 (35) 1.37 (35) 1.37 (35) 1.37 (35) h 2.36 (60) 2.36 (60) 2.36 (60) 2.36 (60) h1 2.75 (70) 2.75 (70) 2.75 (70) 2.75 (70) 4-pole contactors lc1 dt20 and dt25 dt32 to dt60 dt20 and dt25 dt32 to dt60 c 3.62 (92) 3.93 (100) 3.97 (101) 4.29 (109) g 5.31 (135) 1.57/1.96 (40/50) 1.37 (35) 1.37 (35) h 2.36 (60) 2.36 (60) 2.36 (60) 2.36 (60) h1 2.75 (70) 2.75 (70) 2.75 (70) 2.75 (70) lc1d09 to d38 and lc1dt20 to dt60 on pre-slotted mounting plate am1pa, pb, pc lc1d40 to d95, lp1d40 to d80 on pre-slotted mounting plate am1pa, pb, pc control circuit: ac dc lc1 d09 to d18 d25 to d38 d09 to d18 d25 to d38 c with cover 3.38 (86) 3.62 (92) 3.76 (95) 3.97 (101) g 1.37 (35) 1.37 (35) 1.37 (35) 1.37 (35) c with cover 3.38 (86) 3.62 (92) 3.74 (95) 3.97 (101) 4-pole contactors control circuit: ac dc lc1 dt20 and dt25 dt32 to dt60 dt20 and dt25 dt32 to dt60 lc1 d40 to d65 d80 and d95 d40 to d65 d80 and d95 c 3.14 (80) 3.66 (93) 4.64 (118) 5.19 (132) c with cover 4.68 (119) 5.11 (130) 6.92 (176) 7.32 (186) g 1.37 (35) 1.37 (35) 1.37 (35) 1.37 (35) lp1 ? ? d40 and d65 d80 h 2.36 (60) 2.36 (60) 2.36 (60) 2.36 (60) c without cover ? ? 6.73 (171) 7.12 (181) note: units with dc coils have round mounting holes only and are spaced at 70 mm. lc1d09 to d38 panel mounted lc1d40 to d95, lp1d40 to d80 panel mounted control circuit: ac dc lc1 d09 to d18 d25 to d38 d09 to d18 d25 to d38 c with cover 3.38 (86) 3.62 (92) 3.76 (95) 3.97 (101) control circuit: ac dc 4-pole contactors lc1 d40 to d65 d80 and d95 d4 to d65 d80 and d95 c with cover 4.68 (119) 5.11 (130) 6.92 (176) 7.92 (186) lc1 dt20 and dt25 dt32 to dt60 dt20 and dt25 dt32 to dt60 lp1 ? ? d40 and d65 d80 c with cover 3.54 (90) 3.85 (98) 3.54 (90) 3.85 (98) c without cover ? ? 6.73 (171) 7.12 (181) lc1d115, d150 panel mounted lc1 d115 d1156 d150 d1506 c 5.19 (132) 4.52 (115) 5.19 (132) 4.52 (115) g (3-pole) 3.77/4.33 (96/110) 3.77/4.33 (96/110) 3.77/4.33 (96/110) 3.77/4.33 (96/110) g (4-pole) 5.11/5.66 (130/144) 5.11/5.66 (130/144) ?? selection: pages 88 characteristics: pages 80 - 87 schematics: pages 126, 127 q units with dc coils have round mounting holes only and are spaced at 70 mm. c 0.6 h h1 dz5-me8 g 15 h af1-ea4 g c af1-ea6 1.58 4.33 c 40 110 2.36/2.76 = = 1.38 == 2xm4 c 35 60/70 2xm0.16 q c 1.57 == 3.94/4.33 == == == == 3x0.26 = = 40 3x6.5 100/110 130 = = 158 cg = =
tesys? d-line contact ors and starters schematics for type lc1d contactors ? 2001-2004 schneider electric all rights reserved 126 01/04 schematics for type lc1d contactors (1) items in brackets are for blocks mounted on right-hand side of contactor. 3-pole contactors ac magnetic 3-pole contactor with overload relay lc1d09 to d150 4-pole contactors lc1 and lp1 d12004 to d80004 lc1d115004 lc1 and lp1 d12008 to d25008 lc1 and lp1 d40008 to d80008 front mounting add-on contact blocks instantaneous auxiliary contacts one n.o. ladn10 (1) one n.c. ladn01 (1) one n.o. + 1 n.c. ladn11 two n.o. ladn20 two n.c. ladn02 two n.o. + two n.c. ladn22 one n.o. + three n.c. ladn13 four n.o. ladn40 four n.c. ladn04 two n.o. + two n.c. including one n.o. + one n.c. make before break ladc22 three n.o. + one n.c. ladn31 front mounting add-on contact bocks instantaneous auxiliary contacts conforming to standard en 50012 one n.o. + one n.c. ladn11g one n.o. + one n.c. ladn11p tw o n.o. + two n.c. ladn22g two n.o. + two n.c. ladn22p a1 a2 13/no 14 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 22 21/nc l1 l2 l3 t1 t2 t3 m 98 97 b a 13 14 96 95 a1 a2 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 7/l4 t4/8 a1 a2 1 2 r1 r2 r3 r4 3 4 a1 a2 r1 r2 r3 r4 1 2 3 4 43 no 44 43/no (94) (93) 42 41/nc (91) (92) 53/no 54 62 61/nc 63/no 64 53/no 54 52 51/nc 62 61/nc 72 71/nc 62 61/nc 83/no 84 53/no 54 72 71/nc 62 61/nc 53/no 54 82 81/nc 83/no 84 73/no 74 63/no 64 53/no 54 52 51/nc 62 61/nc 72 71/nc 82 81/nc 53/no 54 61/nc 62 87/no 88 75/nc 76 62 61/nc 83/no 84 73/no 74 53/no 54 32 31/nc 43/no 44 22 21/nc 13/no 14 32 31/nc 42 41/nc 63/no 64 53/no 54 32 31/nc 22 21/nc 43/no 44 13/no 14
tesys? d-line contactors and starters schematics for type lc1d contactors 127 01/04 ? 2001-2004 schneider electric all rights reserved front mounting add-on contact blocks dust and damp protected inst antaneous auxiliary contacts two n.o. (24-50 v) la1dx20 two n.c. (24-50 v) la1dx02 two n.o. (5-24 v) la1dy20 two n.o. protected (24-50 v) two n.o. standard la1dz40 two n.o. protected (24-50 v) + one n.o. + one n.c. standard la1dz31 front mounting add-on contact blocks time-delay auxiliary contacts on-delay one n.o. + one n.c. ladt off-delay one n.o. + one n.c. ladr on-delay n.c. with one n.o. break before make lads mechanical latch blocks la6dk10 and la6dk20 side mounting add-on contact blocks instantaneous au xiliary contacts one n.o. + one n.c. lad8n11 (1) two n.o. lad8n20 (1) two n.c. lad8n02 (1) (1) items in brackets are for blocks mounted on right-hand side of contactor electronic serial timer modules auto-man-stop modules on-delay la4dt ? ula4dm k (1) plc interface modules relay interface la4df ? la4dfbq relay interface with solid state override switch la4dl ? la4dwb ? 53/no 54 63/no 64 51/nc 52 61/nc 62 53/no 54 63/no 64 53/no 54 83/no 84 63/no 64 73/no 74 62 61/nc 53/no 54 83/no 84 73/no 74 55/nc 56 67/no 68 66 65/nc 57/no 58 67/no 68 55/nc 56 a1 a2 e1 e2 162 161/nc (171) (172) 153/no 154 (183) (184) 153/no 154 (184) (183) 163/no 164 (174) (173) 162 161/nc (171) (172) 151/nc 152 (181) (182) k a1 a2 a1 a2 t 0 k a1 a2 a2 b1 a1 (1) auto/man i/o (1) plc k a1 a2 e1 + e2 - k a1 a2 e1 + e2 - k a1 a2 e1 + e2 - k a1 a2 e1 + e2 -
tesys? d-line contact ors and starters dimensions for type lc2d contactors ? 2001-2004 schneider electric all rights reserved 128 01/04 dimensions for type lc2d contactors lc2d09 to d38 2 x lc1d09 to d38 lc2dt20 to dt60 2 x lc1dt20 to dt60 lc2 or 2 x lc1 abc (1) e1e2g d09 to d18 ac 3.54 (90) 3.03 (77) 3.38 (86) 0.15 (4) 0.05 (1.5) 3.14 (80) d093 to d183 ac 3.54 (90) 3.89 (99) 3.38 (86) ? ? 3.14 (80) d09 to d18 dc 3.54 (90) 3.03 (77) 3.74 (95) 0.15 (4) 0.05 (1.5) 3.14 (80) d093 to d183 dc 3.54 (90) 3.89 (99) 3.74 (95) ? ? 3.14 (80) d12004 ? 2.91 (74) 3.14 (80) ? 0.23 (6) 3.74 (95) d25 to d38 ac 3.54 (90) 3.34 (85) 3.62 (92) 0.35 (9) 0.19 (5) 3.14 (80) d253 to d383 ac 3.54 (90) 3.89 (99) 3.62 (92) ? ? 3.14 (80) d25 to d32 dc 3.54 (90) 3.34 (85) 3.97 (101) 0.35 (9) 0.19 (5) 3.14 (80) lc2 or 2 x lc1 ab c g d253 to d383 dc 3.54 (90) 3.89 (99) 3.97 (101) ? ? 3.14 (80) dt20 and dt25 3.54 (90) 3.34 (85) 3.54 (90) 3.14 (80) d25004 ? 3.30 (84) 3.66 (93) ? 0.22 (7) 4.37 (111) dt32 to dt60 3.54 (90) 3.58 (91) 3.85 (98) 3.14 (80) e1 and e2: including cabling. c, e2: including cabling. (1) with safety cover, without add-on block. lc2d40 to d65 2 x lc1d40 to d65 2 x lp1d40 and d65 lc2 or 2 x lc1 a b c e1 e2 g g1 d40 to d65 6.49 (165) 5.0 (127) 5.6 (142) 0.49 (5) ? 1.96 (50) 3.54 (90) d40004 7.16 (182) 5.0 (127) 5.2 (133) ? 0.78 (11) 2.24 (57) 3.81 (97) d65004 7.16 (182) 5.0 (127) 5.2 (133) ? 0.78 (11) 2.24 (57) 3.81 (97) lc2 or 2 x lc1 ab c e1e2gg1 d80 and d95 7.16 (182) 5.0 (127) 6.2 (158) 0.5 (13) ? 2.24 (57) 3.77 (96) d40 to d65 7.16 (182) 5.0 (127) 7.4 (190) 1.19 (5) 0.43 (11) 2.2 (57) 3.8 (97) d80004 8.14 (207) 5.0 (127) 6.2 (158) ? 1.78 (20) 2.79 (71) 4.37 (111) d80 and d95 8.14 (207) 11.0 (127) 8.4 (215) 0.51 (13) 0.78 (20) 3.7 (96) 4.3 (111) c, e1 and e2: including cabling. c, e1 and e2: including cabling. lc2d115 and d150 2 x lc1d115 and d150 lc2 or 2 x lc1 ac e1e2 g d115, d150 10.5 (266) 5.9 (148) 2.2 (56) 0.7 (18) 9.5/10.0 (242/256) d115004 13.1 (334) 5.9 (148) ? 2.4 (60) 12.2/12.7 (310/324) c, e1 and e2: including cabling. selection: pages 93 characteristics: pages 80, 87 schematics: pages 129 2xm0.16 g a = = 2.36/2.76 = = c be1 e2 60/70 2xm4 2xm0.16 g a = = 2.36/2.76 = = c b e2 60/70 2xm4 c b e1 e2 g1 = = 6x?0.26 1.57 a == g 1.57 3.94/4.33 0.31 .051 6x?6.5 40 40 13 8 100/110 c be1 e2 g1 = = 6x?6.5 1.57 a == g 1.57 100/110 6x?0.26 8 0.31 13 0.51 40 40 3.94/4.33 6.22 e1 e2 c g a = = 5.12 = = 158 130
tesys? d-line contactors and starters schematics for type lc2d contactors 129 01/04 ? 2001-2004 schneider electric all rights reserved schematics for type lc2d contactors xxx reversing contactors for motor contro l, horizontally mounted lc2d09 to d150 reversing contactors for motor control with integral electrical interlocking (lad9r1v) reversing contactor with overload relay changeover contactor pairs, horiz ontally mounted lc2dt20 to dt60 electrical interlocking of contactors using: mechanical interlock with integral electrical contacts la9d ??? 02 mechanical interlock without in tegral electrical contacts la9d ??? 78, lad9r1 low speed - high speed cabling kit 14 a1 a2 1 2 3 4 5 6 l1 l2 l3 1 2 3 4 5 6 u v w 13/no 14 13/no a1 a2 22 21/nc 22 21/nc 14 a1 a2 1 2 3 4 5 6 l1 l2 l3 1 2 3 4 5 6 u v w 13/no 14 13/no a1 a2 22 21/nc 22 21/nc l1 l2 l3 21 22 + + b a b a f r t1 t2 t3 21 22 + + 97 98 96 95 "c" a1 a2 1 2 3 4 5 6 1/l1 1/l2 1/l3 1 2 3 4 7 8 l1 l2 n a1 a2 5 6 l3 7 8 1n 2/l1 2/l2 2/l3 2n 01 02 01 02 a1 a2 a2 a1 a2 a2 ? km2 ? km1 a1 a2 ? km1 01 02 a1 a2 ? km2 01 02 a1 a2 ? km1 ? km2 a1 a2 ? km2 ? km1 14 a1 a2 1 2 3 4 5 6 1 2 3 4 l1 l2 l3 1 2 3 4 5 6 u v w 13/no 14 13/no a1 a2 a1 a2 22 21/nc 22 21/nc low speed high speed r1 r2 r3 r4 ls/hs lad-
tesys? d-line contact ors and starters lr2 and lr3d 3-pole bimetallic overload relays ? 2001-2004 schneider electric all rights reserved 130 01/04 reset stop 5 4 3.5 3 01 1 6 2 5 4 7 3 lr2 and lr3d 3-pole bimetallic overload relays description d-line 3-pole thermal overload relays are designed to protect ac circuits and motors against overloads, phase failure, long sta rting times and prolonged stalling of the motor. lrd01 to 35 lrd3322 to 4369 , lr2d 1 adjustment dial ir 2 test button operation of the test button allows: - checking of control circuit wiring, - simulation of relay tripping (actuates both the n.o. and n.c. contacts). 3 stop button. actuates the n.c. contact; does not affect the n.o. contact. 4 reset button 5 trip indicator 6 setting locked by sealing the cover. 7 selector for manual or automatic reset. relays lrd01 to lrd35 are supplied with the selector in the manual position, protecte d by a cover. deliberate action is required to move it to the automatic position. environment conforming to standards iec 60947-1, iec 60947-4-1, nf c 63-650, vde 0660, bs 4941 product certifications csa, ul, sichere trennung, ptb except lad4: ul, csa. degree of protection conforming to vde 0106 protection against direct finger contact ip 2x protective treatment conforming to iec 60068 ?th? ambient air temperature around the device storage c - 60 to + 70 (- 140 to + 158 f) normal operation, without derating (iec 60947-4-1) c - 20 to + 60 (- 68 to + 140 f) minimum and maximum operating temperatures (with derating) c - 40 to + 70 (- 104 to + 158 f) operating positions without derating in relation to normal, vertical mounting plane any position shock resistance permissible acceleration conforming to iec 60068-2-7 15 gn - 11 ms vibration resistance permissible acceleration conforming to iec 60068-2-6 6 gn dielectric strength at 50 hz conforming to iec 60255-5 kv 6 impulse withstand voltage conforming to iec 60801-5 kv 6 auxiliary contact characteristics conventional rated thermal current a 5 amps ac; 1 amp dc maximum consumption of operating coils of controlled contactors (occasional operating cycles of contact 95-96) ac supply v 24 48 110 220 380 600 va 100 200 400 600 600 600 dc supply v 24 48 110 220 440 ? w 100 100 50 45 25 ? short-circuit protection k by gg, bs or class cc fuse. max. rating or by gb2 circuit-breaker a 5 maximum connection to screw clamp terminals min - max c.s.a. flexible cable with cable end one or two conductors awg (mm 2 ) 18 - 14 (1 - 2.5) solid cable without cable end one or two conductors awg (mm 2 ) 18 - 14 (1 - 2.5) flexible cable without cable end one or two conductors awg (mm 2 ) 18 - 14 (1 - 2.5) solid cable without cable end one or two conductors awg (mm 2 ) 18 - 14 (1 - 2.5) tightening torque lb-in (n.m) 15 (1.7) k select short circuit protection to meet the national electrical code or other local codes and standards. catalog numbers: pages 134, 135 dimensions: pages 138 - 140 50 a 41 r e s e t test 98 97 95 96 no nc ma 37 46 1 5 3 4 2 6
tesys? d-line contactors and starters lr2 and lr3d 3-pole bimetallic overload relays 131 01/04 ? 2001-2004 schneider electric all rights reserved electrical characterist ics of power circuit relay type lrd 01 to 16 lr3 d01 to d16 lr2 d15 ?? lrd 21 to 35 lr3 d21 to d35 lr2 d25 ?? lrd 3322 to 33696 lr3 d3322 to d33696 lr2 d35 ?? lrd 4365 to 4369 tripping class to ul 508, iec 60947-4-1 10 20 10 20 10 20 10 rated insulation voltage (ui) conforming to iec 60947-4-1 v 690 690 1000 1000 conforming to ul, csa v 600 600 600 600 except lrd4369 rated impulse withstand voltage (uimp) kv 66 66 frequency limits of the operational current hz 0 to 400 0 to 400 0 to 400 0 to 400 setting range depending on model a 0.1 to 13 12 to 38 17 to 104 80 to 140 connection to scre w clamp terminals min - max c.s.a. flexible cable without cable end one conductor awg (mm 2 ) 14 - 8 (1.5 - 10) 14 - 8 (1.5 - 10) 10 - 2 (4 - 35) 10 - 1 (4 - 50) flexible cable with cable end one conductor awg (mm 2 ) 16 - 12 (1 - 4) 16 - 10 (1 - 6) except lrd21 : 16 - 12 (1 - 4) 10 - 2 (4 - 35) 10 - 2 (4 - 35) solid cable without cable end one conductor awg (mm 2 ) 16 - 10 (1 - 6) 14 - 8 (1.5 - 10) except lrd21 : 16 - 10 (1 - 6) 12 - 2 (4 - 35) 10 - 1 (4 - 50) tightening torque lb-in (n.m) 15.0 (1.7) 16.4 (1.85) 22.1 (2.5) 100 lb-in 100 lb-in connection to spring terminals min - max c.s.a. flexible cable without cable end one conductor awg (mm 2 ) 14 - 12 (1.5 - 4) ? 14 - 12 (1.5 - 4) ? ? ? ? solid cable without cable end one conductor awg (mm 2 ) 14 - 12 (1.5 - 4) ? 14 - 12 (1.5 - 4) ? ? ? ? operating characteristics temperature compensation c f - 20 to + 60 - 68 to + 140 - 30 to + 60 - 86 to + 140 - 30 to + 60 - 86 to + 140 - 20 to + 60 - 68 to + 140 tripping threshold conforming to iec 60947-4-1 a 1.14 0.06 in sensitivity to phase failure conforming to iec 60947-4-1 tripping current 30% of in on one phase, the others at in tripping curves average operating time related to multiples of the current setting 1 balanced operation, 3-phase, from cold state. 2 balanced operation, 2-phase, from cold state. 3 balanced operation, 3-phase, after a long period at the set current (hot state). catalog numbers: pages 134, 135 dimensions: pages 138 - 140 2 1 40 20 10 4 2 1 40 20 10 4 2 1 0.8 0.8 1 2 4 6 10 17 20 1 3 2 hours minutes seconds class 10 x times current setting (ir) 2 1 40 20 10 4 2 1 40 20 10 4 2 1 0.8 0.8 1 2 4 6 10 17 20 1 3 2 hours minutes seconds class 20 x times current setting (ir)
tesys? d-line contact ors and starters lr9d 3-pole solid-state overload relays ? 2001-2004 schneider electric all rights reserved 132 01/04 lr9d 3-pole solid-state overload relays description lr9d electronic thermal overload relays are designed for use with contactors lc1d115 and d150. in addition to the protection provided by model d thermal overload relays, (see page 130), they offer the following special fea tures: k protection against phase imbalance. k choice of starting class. k protection of unbalanced circuits. k protection of single-phase circuits. k alarm function to avoid tripping by load shedding. 1 setting dial ir 2 test button 3 stop button 4 reset button 5 trip indication 6 setting locked by sealing the cover 7 class 10/class 20 selector 8 selector for balanced load / unbalanced load lr9d5367 to d5569 lr9d67 and d69 environment conforming to standards iec 60947-4-1, 255-8, 255-17, vde 0660 and en 60947-4-1 product certifications ul 508, csa 22-2 degree of protection conformi ng to iec 60529 and vde 0106 ip 20 on front face with protective covers la9d11570 ? or d11560 ? protective treatment standard version ?th? ambient air temperature around the device (conforming to iec 60255-8) storage c - 40 to + 85 (- 104 to + 185 f) normal operation c - 20 to + 55 (1) (- 68 to + 131 f) maximum operating altitude without derating ft/m 6562 (2000) operating positions without derating in relation to normal, vertical mounting plane any position shock resistance permissible acceleration conforming to iec 60068-2-27 13 gn - 11 ms vibration resistance permissible acceleration conforming to iec 60068-2-6 2 gn - 5 to 300 hz dielectric strength at 50 hz conforming to iec 60255-5 kv 6 impulse withstand voltage conforming to iec 61000-4-5 kv 6 resistance to electrostatic discharge conforming to iec 61000-4-2 kv 8 resistance to radio-frequency conducted di sturbances conforming to iec 61000-4-3 and nf c 46-022 v/m 10 resistance to fast transient currents conforming to iec 61000-4-4 kv 2 electromagnetic compatibility draft en 50081-1 and 2, en 50082-2 v meets requirements electrical characteristi cs of auxiliary contacts conventional thermal current a 5 maximum consumption of operating coils of controlled contactors (occasional operating cycles of contact 95-96) ac supply v 24 48 110 220 380 600 va 100 200 400 600 600 600 dc supply v 24 48 110 220 440 ? w 100 100 50 45 25 ? short-circuit protection k by gg, bs or class cc fuse or by gb2 circuit- breaker a 5 cabling one or two conductors awg (mm 2 ) minimum c.s.a.: 16 ( 1) / maximum c.s.a.: 14 (2.5) flexible cable without cable end tightening torque lb-in (n.m) 11 (1.2) (1) for operation at 70 c (158 f), please consult your regional sales office. k select short circuit protection to meet the national electrical code or other local codes and standards. catalog numbers: pages 135 dimensions: pages 138 ir(a) 150 90 127 107 no 97 98 nc 95 96 2 3 1 4 5 6 alarm no 97 98 nc 95 96 1 7 8 2 3 4 6 5 ir(a) 150 90 127 107 + 24 v - / 103 104 10 20 class load
tesys? d-line contactors and starters lr9d 3-pole solid-state overload relays 133 01/04 ? 2001-2004 schneider electric all rights reserved electrical characterist ics of power circuit relay type lr9-d tripping class conforming to ul 508, iec 60947-4-1 10 or 20 rated insulation voltage (ui) conforming to iec 60947-4-1 1000 v conforming to ul, csa 600 v rated impulse withstand voltage (uimp) 8 kv frequency limits of the operational current 50-60 hz for other frequencies, consult your regional sales office. (1) setting range depending on model 60-150 a power circuit connections width of terminal lug 0.787 in (20 mm) clamping screw m8 tightening torque lb-ft 13 (18 nm) operating specifications temperature compensation -20 to +70 c (- 68 to + 158 f) tripping threshold conforming to iec 60947-4-1 alarm 1.05 0.06 in a tripping 1.12 0.06 in a sensitivity to phase failure conforming to iec 60947-4-1 tripping current 4 s 20% in the event of phase failure alarm circuit specifications rated supply voltage dc supply 24 vdc supply voltage limits 17 - 32 v current consumption no load less than or equal to 5 ma switching capacity 0 - 150 ma protection short-circuit and overload self-protected voltag e drop closed state less than or equal to 2.5 v cabling flexible cable without cable end 20 - 16 awg (0.5 - 1.5 mm 2 ) tightening torque 4.0 lb-in (0.45 nm) tripping curve lr9-d average operating time related to multiples of the current setting (1) for use of these relays with soft start units or variable speed controllers, please consult your regional sales office. catalog numbers: pages 135 dimensions: pages 138 1 cold state curve. 2 hot state curve. 1 000 100 10 1 0 1.12 2 3 4 5 6 7 8 9 10 11 12 1 2 t ripping time in seconds x the current setting (ir)
tesys? d-line contact ors and starters selection of 3-pole class 10 bimetallic overload relays ? 2001-2004 schneider electric all rights reserved 134 01/04 selection of 3-pole class 10 bimetallic overload relays differential (single phase sensitive) ther mal overload relays compensated relays with manual or automatic reset, with relay trip indicator, for ac or dc. short-circuit protection for north american applications by circuit breaker select in accordance with nec and local codes by fuses maximum 400% of motor fla relay setting range fuses to be used with selected relay for use with contactor lc1- catalog number weight lb. (kg) am gg bs88 aaaa class 10 with connection by screw clamp terminals 0.10 to 0.16 0.25 2 ? d09 to d38 (2) lrd01 0.27 (0.124) 0.16 to 0.25 0.5 2 ? d09 to d38 (2) lrd02 0.27 (0.124) 0.25 to 0.40 1 2 ? d09 to d38 (2) lrd03 0.27 (0.124) 0.40 to 0.63 1 2 ? d09 to d38 (2) lrd04 0.27 (0.124) 0.63 to 1 2 4 ? d09 to d38 (2) lrd05 0.27 (0.124) 1 to 1.6 2 4 6 d09 to d38 (2) lrd06 0.27 (0.124) 1.6 to 2.5 4 6 10 d09 to d38 (2) lrd07 0.27 (0.124) 2.5 to 4 6 10 16 d09 to d38 (2) lrd08 0.27 (0.124) 4 to 6 8 16 16 d09 to d38 (2) lrd10 0.27 (0.124) 5.5 to 8 12 20 20 d09 to d38 (2) lrd12 0.27 (0.124) 7 to 10 12 20 20 d09 to d38 (2) lrd14 0.27 (0.124) 9 to 13 16 25 25 d12 to d38 (2) lrd16 0.27 (0.124) 12 to 18 20 35 32 d18 to d38 (2) lrd21 0.27 (0.124) 16 to 24 25 50 50 d25 to d38 (2) lrd22 0.27 (0.124) 23 to 32 40 63 63 d25 to d38 (2) lrd32 0.27 (0.124) 30 to 38 50 80 80 d32 and d38 (2) lrd35 0.27 (0.124) 17 to 25 25 50 50 d40 to d95 lrd3322 1.12 (0.510) 23 to 32 40 63 63 d40 to d95 lrd3353 1.12 (0.510) 30 to 40 40 100 80 d40 to d95 lrd3355 1.12 (0.510) 37 to 50 63 100 100 d40 to d95 lrd3357 1.12 (0.510) 48 to 65 63 100 100 d50 to d95 lrd3359 1.12 (0.510) 55 to 70 80 125 125 d50 to d95 lrd3361 1.12 (0.510) 63 to 80 80 125 125 d65 to d95 lrd3363 1.12 (0.510) 80 to 104 100 160 160 d80 and d95 lrd3365 1.12 (0.510) 80 to 104 125 200 160 d115 and d150 lrd4365 1.98 (0.900) 95 to 120 125 200 200 d115 and d150 lrd4367 1.98 (0.900) 110 to 140 160 250 200 d150 lrd4369 1.98 (0.900) 80 to 104 100 160 160 d115 and d150 lrd33656 (1) 2.20 (1.000) 95 to 120 125 200 200 d115 and d150 lrd33676 (1) 2.20 (1.000) 110 to 140 160 250 200 d115 and d150 lrd33696 (1) 2.20 (1.000) class 10 with spring terminal connections (for direct mounting on the contactor only) 0.10 to 0.16 0.25 2 ? d09 to d38 (2) lrd013 6.31 (0.140) 0.16 to 0.25 0.5 2 ? d09 to d38 (2) lrd023 6.31 (0.140) 0.25 to 0.40 1 2 ? d09 to d38 (2) lrd033 6.31 (0.140) 0.40 to 0.63 1 2 ? d09 to d38 (2) lrd043 6.31 (0.140) 0.63 to 1 2 4 ? d09 to d38 (2) lrd053 6.31 (0.140) 1 to 1.6 2 4 6 d09 to d38 (2) lrd063 6.31 (0.140) 1.6 to 2.5 4 6 10 d09 to d38 (2) lrd073 6.31 (0.140) 2.5 to 4 6 10 16 d09 to d38 (2) lrd083 6.31 (0.140) 4 to 6 8 16 16 d09 to d38 (2) lrd103 6.31 (0.140) 5.5 to 8 12 20 20 d09 to d38 (2) lrd123 6.31 (0.140) 7 to 10 12 20 20 d09 to d38 (2) lrd143 6.31 (0.140) 9 to 13 16 25 25 d12 to d38 (2) lrd163 6.31 (0.140) 12 to 18 20 35 32 d18 to d38 (2) lrd213 6.31 (0.140) 16 to 24 25 50 50 d25 to d38 (2) lrd223 6.31 (0.140) class 10 with ring-tongue terminals for lrd01 through lrd35 (load side terminals only) select the appropriate overload relay with screw clamp terminals from the table above and add 6 to the end of the reference. example: lrd01 becomes lrd016 . thermal overload relays for use on single phase loads class 10 with connection by screw clamp terminals change the prefix in the references above from lrd (except lrd4 kkk ) to lr3d . example: lrd01 becomes lr3d01. thermal overload relays for use on 1000 v supplies class 10 with connection by screw clamp terminals for relays lrd-01 to lrd-35 only, for an operating voltage of 1000 v, and only for independent mounting, the reference becomes lrd33 a66 . example: lrd12 becomes lrd3312a66. order an la7d3064 terminal block separately; see page 137. (1) these are special separate mounted versions of the lrd43 overload relays for the lc1d115 and d150 contactors. part number in cludes overload relay, terminal block and 6 connectors (unit is not ul/csa approved). (2) when used with d25-d38 contactors, order spacer clip (part number w816366180111). see page 137. lrd08 lrd21 lrd33 lrd083
tesys? d-line contactors and starters selection of 3-pole class 20 bimetallic and class 10 solid-state overload relays 135 01/04 ? 2001-2004 schneider electric all rights reserved selection of 3-pole class 20 bimetallic and class 10 solid-state overload relays differential (single phase sensitive) thermal overload relays compensated relays with manual or automatic reset, with relay trip indicator, for ac or dc lr2-d1508 to 2553: independent mounting either by ordering a terminal block la7d1064 or la7d2064 , or by ordering the relay pre-assembled; in this case, add the suffix la7 to the reference. example: lr2d1508 becomes lr2d1508la7 . short-circuit protection for north american applications by circuit breaker select in accordance with nec and local codes by fuses maximum 400% of motor fla relay setting range fuses to be used with the selected relay for use with contactor catalog number weight lb. (kg) am gg bs88 lc1 aa a a class 20 for connection by screw clamp terminals 2.5 to 4 6 10 16 d09 to d38 (2) lrd1508 (3) 0.42 (0.190) 4 to 6 8 16 16 d09 to d38 (2) lrd1510 (3) 0.42 (0.190) 5.5 to 8 12 20 20 d09 to d38 (2) lrd1512 (3) 0.42 (0.190) 7 to 10 16 20 25 d09 to d38 (2) lrd1514 (3) 0.42 (0.190) 9 to 13 16 25 25 d12 to d38 (2) lrd1516 (3) 0.42 (0.190) 12 to 18 25 35 40 d18 to d38 (2) lrd1521 (3) 0.42 (0.190) 17 to 25 32 50 50 d25 and d38 (2) lrd1522 (3) 0.42 (0.190) 23 to 28 40 63 63 d25 and d38 (2) lrd1530 (3) 0.76 (0.345) 25 to 32 40 63 63 d25 and d38 (2) lrd1532 (3) 0.76 (0.345) 17 to 25 32 50 50 d40 to d95 lrd3522 1.18 (0.535) 23 to 32 40 63 63 d40 to d95 lr2d3553 1.18 (0.535) 30 to 40 50 100 80 d40 to d95 lr2d3555 1.18 (0.535) 37 to 50 63 100 100 d50 to d95 lr2d3557 1.18 (0.535) 48 to 65 80 125 100 d50 to d95 lr2d3559 1.18 (0.535) 55 to 70 100 125 125 d65 to d95 lr2d3561 1.18 (0.535) 63 to 80 100 160 125 d80 and d95 lr2d3563 1.18 (0.535) solid-state differential thermal overload relays compensated relays, with relay trip indicator, for ac or dc, for direct mounting on contactor or independent mounting (1). relay setting range fuses to be used with selected relay (4) for direct mounting beneath contactor lc1 catalog number weight lb. (kg) am gg aa a class 10 for connection using bars or connectors 60 to 100 100 160 d115 and d150 lr9d5367 1.95 (0.885) 90 to 150 160 250 d115 and d150 lr9d5369 1.95 (0.885) class 20 for connection using bars or connectors 60 to 100 125 160 d115 and d150 lr9d5567 1.95 (0.885) 90 to 150 200 250 d115 and d150 lr9d5569 1.95 (0.885) solid-state thermal over load relays for use with balanced /unbalanced loads (single phase) compensated relays, with separate outputs for alarm and tripping. relay setting range fuses to be used with selected relay (4) for direct mounting beneath contactor lc1 catalog number weight lb. (kg) am gg aa a class 10 or 20 selectable with connection using bars or connectors 60 to 100 100 160 d115 and d150 lr9d67 1.98 (0.900) 90 to 150 160 250 d115 and d150 lr9d69 1.98 (0.900) (1) power terminals can be protected against direct finger contact by the addition of shrouds and/or insulated terminal blocks, to be ordered separately (see page 113). (2) for use with d25-d38 contactors, order spacer clip (part number w816366180111). see page 137. (3) these overloads are available without single phase sensitivity. to order, change the lrd prefix to lr3d and add a1 to the en d of the number. example: lrd1508 becomes lr3d1508a1 (4) select short circuit protection to meet the national electrical code or other local codes and standards. other versions thermal overload relays for resistive circuits in category ac-1. please consult your regional sales office. lrd15 lr2d35
tesys? d-line contact ors and starters selection of overload relay accessories ? 2001-2004 schneider electric all rights reserved 136 01/04 selection of overload relay accessories dx1-ap26 la7-d901 la7-d2064 la7-d902 lad-703 la7-d03 la7-d03 dx1-ap25 la7-d1064 lad-7b10 la7-d3064 lr2-d15 lrd- lrd- lrd- lr2-d25 lrd-3 lr2-d35 la7-d1020 xb5-aa86102 la7-d1020 xb5-al84101 la7-d305 lad-7305 lrd-3 lr2-d lrd-3
tesys? d-line contactors and starters selection of overload relay accessories 137 01/04 ? 2001-2004 schneider electric all rights reserved accessories (to be ordered separately) description for use on: sold in lots of: catalog number weight lb. (kg) pre-wiring kit allowing direct connection of the n.c. contact of relay lrd01 to 35 or lr3d01 to d35 to the contactor lc1d09 to d18 10 lad7c1 0.002 (0.004) lc1d25 to d38 10 lad7c2 0.003 (0.007) separate mount kits terminal blocks (1) for separate mounting on 35 mm rail (am1dp200) or screw mounting; for mounting centers, see pages 138 to 140. lrd01 to 35 and lr3d01 to d35 1 lad7b10 0.100 (0.22) lrd15 kk 1 lad7b105 0.100 (0.22) lr2d15 kk 1 la7d1064 0.100 (0.22) lr2d25 kk 1 la7d2064 0.120 (0.26) lrd3 kkk , lr3d3 kkk , lr2d35 kk 1 la7d3064 (2) 0.370 (0.82) terminal block adapter for mounting a relay beneath an lc1d115 or d150 contactor lrd3 kkk , lr3d3 kkk , lrd35 kk 1 la7d3058 0.080 (0.18) mounting plates (3) for screw mounting on 110 mm center lrd01 to 35, lr3d01 to d35. lr2d15 kk 10 dx1ap25 0.065 (0.14) lr2d25 kk 10 dx1ap26 0.082 (0.18) lrd3 kkk , lr3d3 kkk , lr2d35 kk 1 la7d902 0.130 (0.29) marker holder snap in all relays except lrd01 to 35 and lr3d01 to d35 (4) 100 la7d903 0.001 (0.002) bag of 400 labels (blank, self-adhesive, 7 x 16 mm) ? 1 la9d91 0.001 (0.002) stop button locking device all relays except lrd01 to 35. lr3d01 to d35 and lr9d 10 la7d901 0.005 (0.01) remote stop or electrical reset device (5) lrd01 to 35 and lr3d01 to d35 1 lad703 ? (6) 0.090 (0.20) remote tripping or el ectrical reset device (5) all relays except lrd01 to 35 and lr3d01 to d35 1 la7d03 ? (6) 0.090 (0.20) block of insulated terminals lr9d 2 la9f103 0.560 (1.23) spacer mounting small overload relays to lc1d25 and lc1d32 10 w816366180111 0.050 (0.023) remote control ?reset? function by flexible cable (length = 0.5 m / 1.64 ft.) lrd01 to 35 and lr3d01 to d35 1 lad7305 0.075 (0.17) all relays except lrd01 to 35 and lr3d01 to d35 1 la7d305 0.075 (0.17) ?stop? and/or ?reset? functions the terminal protection shroud must be removed and the following three products must be ordered separately. adapter for door interlock mechanism all relays except lrd01 to 35 and lr3d01 to d35 1 la7d1020 0.005 (0.01) operating head for spring return push button stop all relays 1 xb5al84101 0.027 (0.06) reset all relays 1 xb5aa86102 0.027 (0.06) (1) terminal blocks are supplied with terminals protected against direct finger contact and screws in the open, ?ready-to-tighte n? position. (2) to order a terminal block (separate mount kit) with ring-tongue terminals, the catalog number becomes la7d30646 . (3) requires separate mount terminal block corresponding to the type of relay. (4) for lrd01 to 35 (see page 114). (5) the time for which the coil of remote tripping or electrical resetting device la7d03 or lad703 can remain energized depends on its rest time: 1 s pulse duration with 9 s rest time; 5 s pulse duration with 30 s rest time; 10 s pulse duration with 90 s rest time; maximum pulse du ration of 20 s with a rest time of 300 s. minimum pulse time: 200 ms. (6) reference to be completed by adding the code indicating control circuit voltage. standard control circuit voltages (for othe r voltages, please consult your regional sales office). volts 12 24 48 96 110 220/230 380/400 415/440 50/60 hz ? b e ? f m q n consumption, inrush and sealed: < 100 va dc j b e dd f m ? ? consumption, inrush and sealed: < 100 w. lad7c lad7b10 overload relay and spacer (w816366180111)
tesys? d-line contact ors and starters dimensions for 3-pole bi-metalic and solid-state overload relays ? 2001-2004 schneider electric all rights reserved 138 08/04 dimensions for 3-pole bi-metallic and solid-state overload relays d-line thermal overload relays lrd-01-35 lrd-013-353 direct mounting beneath contactors with screw direct mounting beneath contactors with spring terminal connections lc1 d09 - d18 d25 - d38 lc1 d093 - 383 b 4.84 (123) 5.39 (137) b 4.84 (123) c see pages 122, 123. c see pages 122, 123. lrd-3 direct mounting beneath contactors lc1-d40 to d95 and lp1-d40 to d80 am1 dl201 dl200 d 0.28 (7) 0.67 (17) bceg(3p)g(4p) ac control circuit: lc1d40 4.37 (111) 4.69 (119) 2.85 (72.4) 0.18 (4.5) 0.51 (13) lc1d50 4.37 (111) 4.69 (119) 2.85 (72.4) 0.18 (4.5) - lc1d65 4.37 (111) 4.69 (119) 2.85 (72.4) 0.18 (4.5) 0.51 (13) lc1d80 4.55 (115.5) 4.88 (124) 3.03 (76.9) 0.37 (9.5) 0.87 (22) lc1d95 4.55 (115.5) 4.88 (124) 3.03 (76.9) 0.37 (9.5) - dc control circuit: lc1d40, lp1d40 4.37 (111) 6.93 (176) 2.85 (72.4) 0.18 (4.5) 0.51(13) lc1d50 4.37 (111) 6.93 (176) 2.85 (72.4) 0.18 (4.5) - lc1d65, lp1d65 4.37 (111) 6.93 (176) 2.85 (72.4) 0.18 (4.5) 0.51(13) lc1d80, d95, lp1d80 4.55 (115.5) 7.06 (179.4) 3.03 (76.9) 0.37 (9.5) 0.87(22) lrd4 lr9d direct mounting beneath contactors lc1d115 and d150 direct mounting beneath contactors lc1d115 and d150 am1dl200 and dr200 am1de200 and ed am1dp200 and dr200 am1de200 and ed d 0.10 (2.5) 0.41 (10.5) d 0.10 (2.5) 0.41 (10.5) characteristics: pages 130 - 133 catalog number: pages 134, 135 dual dimensions: inches mm
tesys? d-line contactors and starters mounting information for bimetallic and solid-state overload relays 139 01/04 ? 2001-2004 schneider electric all rights reserved mounting information for bimetallic and solid-state overload relays d-line thermal overload relays lrd-01-35 independent mounting on 50 mm centers or on rail am1dp200 or de200 independent mounting on 110 mm centers remote tripping or electrical reset (1) can only be mounted on rh side of relay lrd-01 to 35 lrd15 independent mounting on 50 mm center s or on rail am1dp200 or de200 rem ote tripping or electrical reset am1dp200 am1de200 d 0.08 (2) 0.37 (9.5) (1) can be mounted on rh or lh side of relay lr2d15 lr2d25 independent mounting on 50 mm center s or on rail am1dp200 or de200 rem ote tripping or electrical reset am1dp200 am1de200 d 0.08 (2) 0.37 (9.5) (1) can be mounted on rh or lh side of relay lr2d25 characteristics: pages 130 - 133 catalog number: pages 134, 135 1.77 45 0.08 2 3.15 80 1.48 37.5 3.15 80 1.97 50 0.20 5 lad-7b10 1.38 35 0.39 10 0.24 6 .59 15 lad-7b10 4.33 110 = = 1.81 46 = = 2x?0.26 2x?6.5 dx1-ap25 3.54 90 4.92 125 dual dimensions: inches mm lad -7 03 (1) 1.26 32 3.86 98 1.48 43.5 d 3.11 79 la7-d1064 0.16 4 1.97/2.56 50/65 0.31 8 0.67 17 2x ?0.18 2x?4.5 1.38 35 = = 1.77 45 1.34 34 3.78 96 la7-d03(1) 3.86 98 1.71 43.5 d 3.54 90 la7-d2064 0.12 3 0.51 13 0.87 22 2x?0.18 2x?4.5 1.57 40 = = 2.17 55 1.97/2.56 50/65 1.14 29 3.78 96 la7-d03 (1)
tesys? d-line contact ors and starters mounting information for bimetallic and solid-state overload relays ? 2001-2004 schneider electric all rights reserved 140 01/04 d-line thermal overload relays lrd3 and lr2d35 lrd3, lr2d35 and lr9d independent mounting on 50 mm centers or on rail am1dp200 or de200 remote tripping or electrical reset am1dp200 am1de200 d 0.08 (2) 0.37 (9.5) (1) can be mounted on rh or lh side of relay lr23, lr2d35 or lr9d lr2d and lrd3 adapter for door interlock mechanism la7d1020 stop reset c: adjustable from 0.67 to 4.72 in. (17 to 120 mm) lrd, lr2d and lr9d ?reset? by flexible cable la7d305 and lad7305 mounting with cable straight mounting with cable bent c: up to 21.6in (550 mm) e: up to 0.79in (20 mm) e: up to.79in (20 mm) characteristics: pages 130 - 133 catalog number: pages 134, 135 4.76 121 3.94 100 2x0.18 la7-d3064 2.03 51,5 d 2.95/3.43 0.08 2 1.97 50 2.95 75 = = 0.93 23.5 1.26 32 2x4.5 75/87 4.69 119 0.83 21 la7-d03 (1) c 0.39 10 la7-d1020 c e m10x0.04 e m10x1
tesys? d-line contactors and starters capacitor-switching contactors (international applications only) 141 01/04 ? 2001-2004 schneider electric all rights reserved capacitor-switching contactors (international applications only) for switching 3-phase capaci tor banks used for power factor correction - selection (1) upper limit of temperature category conforming to iec 70. standard contactors capacitors, together with the circuits to which they are connected, form oscillatory circuits which can, at the moment of switc h-on, give rise to high transient currents (> 180 in) at high frequencies (1 to 15 khz). as a general rule, the peak current on energizing is lower when: - the mains inductances are high, - the line transformer ratings are low, - the transformer short-circuit voltage is high, - the ratio between the sum of the ratings of the capacitors already switched into the circuit and that of the capacitors to be switched in is small (for multiple step capacitor banks). in accordance with standards iec 60070, nf c 54-100, vde 0560, the switching contactor must be able to withstand a continuous c urrent of 1.43 times the rated current of the capacitor bank step being switched. the rated operational powers given in the tables opposite take this overload into account. short-circuit protection is normally provided by gl type hpc fuses rated at 1.7 to 2 in. contactor applications operating conditions capacitors are directly switched. the values of peak cu rrent at switch-on must not exce ed the values indicated opposite. an inductor may be inserted in each of the three phases supplying the capacitors to reduce the peak current, if necessary. indu ctance values are determined according to the selected operating temperature. power factor correction by a single-step capacitor bank the use of a choke inductor is unnecessary; the inductance of the mains supply is adequate to limit the peak to a value compati ble with the contactor characteristics. power factor correction by a multiple-step capacitor bank select a special contactor as defined on page 142. if a standard contactor is used, it is essential to insert a choke inductor in each of the three phases of each step. maximum operational power of contactors standard contactors maximum operating rate: 120 operating cycles/hour. electrical durability at maximu m load: 100,000 operating cycles. with choke inductors connected, where necessary. operational power at 50/60 hz maximum peak current contactor size ? 40 c / 104 f (1) ? 55 c / 131 f (1) 220 v 400 v 600 v 220 v 400 v 600 v 240 v 440 v 690 v 240 v 440 v 690 v kvar kvar kvar kvar kvar kvar a 6 11 15 6 11 15 560 lc1d09, d12 9 15 20 9 15 20 850 lc1d18 11 20 25 11 20 25 1600 lc1d25 14 25 30 14 25 30 1900 lc1d32, d38 17 30 37 17 30 37 2160 lc1d40 22 40 50 22 40 50 2160 lc1d50 22 40 50 22 40 50 3040 lc1d65 35 60 75 35 60 75 3040 lc1d80, d95 50 90 125 38 75 80 3100 lc1d115 60 110 135 40 85 90 3300 lc1d150 70 125 160 50 100 100 3500 lc1f185 80 140 190 60 110 110 4000 lc1f225 90 160 225 75 125 125 5000 lc1f265 100 190 275 85 140 165 6500 lc1f330 125 220 300 100 160 200 8000 lc1f400 180 300 400 125 220 300 10 000 lc1f500 250 400 600 190 350 500 12 000 lc1f630 250 400 600 190 350 500 14 200 lc1f800
tesys? d-line contact ors and starters capacitor-switching contactors (international applications only) ? 2001-2004 schneider electric all rights reserved 142 01/04 for switching 3-phase capacitor banks, used for power factor correction direct connection without choke inductors - references special contactors special contactors lc1d k k are designed for switching 3-phase, single or multiple-step capacitor banks; they conform to standards iec 60070 and 60831, nfc 54-100, vde 0560, ul and csa. contactor applications specification contactors fitted with a block of early make poles and damping resistors, limiting the value of the current on closing to 60 in max. this current limitation increases the life of all the components of the installation, in particular that of the fuses and capac itors. the patented design of the add-on block (no. 90 119-20) ensures safety and long life of the installation. operating conditions there is no need to us e choke inductors for either single or multiple-step capacitor banks. short-circuit protection must be provided by gi type fuses rated at 1.7 to 2 in. maximum operational power the power values given in the selection table below are for the following operating conditions. prospective peak current at switch-on lc1d ? k200 in maximum operating rate lc1dfk, dgk, dlk, dmk, dpk 240 operating cycles/hour lc1dtk, dwk 100 operating cycles/hour electrical durability at nominal load all contactor ratings 400 v 300,000 operating cycles 690 v 200,000 operating cycles operational power at 50/6 0 hz (1) instantaneous auxiliary contacts tightening torque on cable end basic reference. complete with code indicating control circuit voltag e (2) weight lb. (kg) ? 55 c / 131 f (3) 220 v 400 v 660 v 240 v 440 v 690 v kvar kvar kvar n.o. n.c. lb-in (n.m) 6.7 12.5 18 1 1 11 (1.2) lc1dfk11 ?? 0.94 (0.430) ? 2 11 (1.2) lc1dfk02 ?? 0.94 (0.430) 8.5 16.7 24 1 1 15 (1.7) lc1dgk11 ?? 0.99 (0.450) ? 2 15 (1.7) lc1dgk02 ?? 0.99 (0.450) 10 20 30 1 1 17 (1.9) lc1dlk11 ?? 1.3 (0.600) ? 2 17 (1.9) lc1dlk02 ?? 1.3 (0.600) 15 25 36 1 1 22 (2.5) lc1dmk11 ?? 1.4 (0.630) ? 2 22 (2.5) lc1dmk02 ?? 1.4 (0.630) 20 33.3 48 1 2 44 (5) lc1dpk12 ?? 2.9 (1.300) 25 40 58 1 2 44 (5) lc1dtk12 ?? 2.9 (1.300) 40 60 92 1 2 80 (9) lc1dwk12 ?? 3.6 (1.650) switching of multiple step capacitor banks (with equal or different power ratings). the correct contactor for each step is selected from the above table, according to the power rating of the step to be switched. example: 50 kvar 3-step capacitor bank. temperature 50 c (122 f) and u = 400 v or 440 v. one 25 kvar step: contactor lc1-dmk, one 15 kvar step: contactor lc1-dgk and one 10 kvar step: contactor lc1-dfk. (1) operational power of the contactor according to the schematic on page 143. (2) standard control circuit voltages. volts 24 42 48 110 115 220 230 240 380 400 415 440 50/60 hz b7 d7 e7 f7 fe7 m7 p7 u7 q7 v7 n7 r7 for other voltages between 24 and 440 v, please consult your regional sales office (3) the average temperature over a 24-hour period, in accordance with standards iec 60070 and 60831, is 45 c (113 f). lc1dfk11 ?? lc1dpk12 ??
tesys? d-line contactors and starters capacitor-switching contactors (international applications only) 143 01/04 ? 2001-2004 schneider electric all rights reserved for switching 3-phase capacitor banks, used for power factor correction dimensions, schematics - references zzz dimensions lc1dfk, dgk lc1dpk, dtk lc1 c type of mounting lc1 type of mounting dfk 117 lc1d12 see pages 124, 125 dpk lc1d40 see pages 124, 125 dgk 122 lc1d18 see pages 124, 125 dtk lc1d50 see pages 124, 125 lc1dlk, dmk lc1dwk lc1 c type of mounting lc1 type of mounting dlk 117 lc1d25 see pages 124, 125 dwk lc1d80 see pages 124, 125 dmk 122 lc1d32 see pages 124, 125 schematics lc1d ? k cabling (maximum permissible c.s.a.) r = pre-wired resistor connections contactor type lc1 dfk dgk dlk dmk dpk, dtk dwk number of conductors 1212121 21212 flexible cable with cable end awg (mm 2 ) 14 (2.5) 16 (1.5) 12 (4) 14 (2.5) 12 (4) 12 (4) 10 (6) 12 (4) 6 (16) 10 (6) 1 (50) 4 (25) solid cable without cable end awg (mm 2 ) 12 (4) 12 (4) 10 (6) 10 (6) 8 (10) 10 (6) 6 (16) 8 (10) 4 (25) 6 (16) 1 (50) 2 (35) 1.77 c 2.91 5.12 130 74 45 5.91 5.0 7.09 2.95 180 150 127 75 5.51 c 3.31 2.20 140 84 56 7.87 5.0 6.18 3.35 200 157 127 85 a1 a2 1/l1 2/t1 3/l2 4/t2 5/l3 6/t3 e r e r
tesys? d-line contact ors and starters plate-mounted starters lc4d (international applications only) ? 2001-2004 schneider electric all rights reserved 144 01/04 plate-mounted starters lc4d (international applications only) ac d.o.l. starters, plate mounted, for motor control 4 to 37 kw, (1), with isolating device, pre-assembled - references utilization category ac-3 operational current fuses to be fitted by the customer basic reference. complete with code indicating control circuit voltage (2) weight lb (kg) standard power ratings of 3-phase motors 50/60 hz 220 v 380 v 660 v 440 v size type am 230 v 400 v 415 v 440 v 500 v 690 v up to kw kw kw kw kw kw a a 2.2444 5.5? 9 10 x 38 12 lc4d09a ?? 1.9 (0.870) 3 5.5 5.5 5.5 7.5 ? 12 10 x 38 16 lc4d12a ?? 1.9 (0.870) 47.59910? 18 10 x 38 20 lc4d18a ?? 2.5 (1.150) 5.5 111111 15 ? 25 10 x 38 25 lc4d25a ?? 3.5 (1.580) 7.5 15 15 15 18.5 18.5 32 14 x 51 32 lc4d32a ?? 5.8 (2.630) 11 18.5 22 22 22 30 40 14 x 51 40 lc4d40 ?? 6.5 (2.930) 15 22 25 30 30 33 50 22 x 58 63 lc4d50 ?? 7.0 (3.200) 18.5 30 37 37 37 37 65 22 x 58 80 lc4d65 ?? 7.4 (3.340) 22 37 45 45 55 45 80 22 x 58 80 lc4d80 ?? 8.0 (3.650) specifications pre-wired power and control circuit connections. 3-pole isolating device (1) thermal overload relay to be ordered separately (see pages 134, 135). (2) standard control circuit voltages. volts 24 42 48 110 220 230 240 380 400 415 440 50/60 hz b7 d7 e7 f7 m7 p7 u7 q7 v7 n7 r7 for other voltages, please consult your regional sales office. lc4d09a ??
tesys? d-line contactors and starters plate-mounted starters lc4d (international applications only) 145 01/04 ? 2001-2004 schneider electric all rights reserved d.o.l. starters, plate mo unted, for motor control 4 to 37 kw, with isolating device, pre-assembled - dimensions, schematics z dimensions d.o.l. starters plate mounted, pre-assembled lc4d09 to d25a lc4d32a lc4 d09a to d18a d25a lc4 d32a b 8.58 (218) 8.70 (221) c1 without cover or add-on blocks 3.93 (100) c1 without cover or add-on blocks 3.70 (94) 3.93 (100) with cover, without add-on block 4.01 (102) with cover, without add-on block 3.77 (96) 4.01 (102) with ladn or c (two or four contacts) 5.23 (133) with ladn or c (two or four contacts) 5.0 (127) 5.23 (133) with la6dk10 5.70 (145) with la6dk10 5.47 (139) 5.70 (145) with ladt, r, s 6.02 (153) with ladt, r, s 5.78 (147) 6.02 (153) with ladt, r, s and sealing cover 6.18 (157) with ladt, r, s and sealing cover 5.94 (151) 6.18 (157) lc4-d40 to d80 lc4 d40 to d65 d80 a 11.0 (281) 12.2 (311) b 5.6 (143) 5.6 (143) c 5.1 (130) 5.5 (140) c1 without cover or add-on blocks 4.8 (124) 5.3 (135) with cover, without add-on block 5.2 (129) 5.5 (140) with la1-dn (one contact) 6.1 (149) 6.3 (160) with lad-n or c (two or four contacts) 6.4 (157) 6.6 (168) with la6-dk 6.6 (169) 7.0 (180) with lad-t, r, s 6.9 (177) 7.4 (188) with lad-t, r, s and sealing cover 7.12 (181) 7.5 (192) c2 3.9 (100) 7.0 (178) d.o.l. starters lc4-d09a to d80 6.81 b c1 3.94 119 2.17 2.80 3.39 = = = = 1.97 2.48 4.33 100 173 4.69 63 33 1.3 110 50 86 71 55 0.17 4.2 c1 1.42 4.88 4.33 3.46 3.54 6.50 = = 36 124 6.2 0.24 110 165 90 88 c c1 c2 b b1 g a = = = = 60 100/110 = = 2 4 6 - q1 2 4 1 3 - km1 1/l1 3/l2 5/l3 6 5
tesys? d-line contact ors and starters ac wye-delta starters lc3d (international applications only) ? 2001-2004 schneider electric all rights reserved 146 01/04 ac wye-delta starters lc3d (international applications only) 5.5 to 132 kw, (1), without isolatin g device, pre-assembled - references note: wiring methods differ from typical north american practice. contains ul listed, csa certified, ce marked components. assemblies are not ul listed or csa certified. standard power ratings of squirrel cage motors auxiliary contacts available on each contactor star delta mechanical interlock catalog number complete with code indicating control circuit voltage (2) weigh lb. (kg) line delta star km2 km3 km1 line voltage - delta connection 220/ 230 v 380/ 400 v 415 v 440 v kw kw kw kw plate mounted maximum operating rate: 30 starts/hour. maximum starting time: 30 seconds. 4 7.5 7.5 7.5 ? ? ? ? (3) ? 1 with lc3d09a ?? 3.4 (1.530) 5.5 11 11 11 ? ? ? ? (3) ? 1 with lc3d12a ?? 3.4 (1.530) 11 18.5 22 22 ? ? ? ? (3) ? 1 with lc3d18a ?? 3.8 (1.730) 15 25 30 30 ? ? ? ? (3) ? 1 with lc3d32a ?? 4.5 (2.030) 18.5 37 37 37 ? 1 1 ? (3) ? 1 without lc3d40 ?? 9.6 (4.360) with lc3d40 ?? a64 9.9 (4.500) 30 55 59 59 ? 1 1 ? (3) ? ? (3) without lc3d50 ?? 9.6 (4.360) with lc3d50 ?? a64 9.9 (4.500) 37 75 75 75 ? 1 1 ? (3) ? ? (3) without lc3d80 ?? 11.5 (5.200) with lc3d80 ?? a64 12.0 (5.400) 63 110 110 110 ? 1 1 ? (3) ? ? (3) without lc3d115 ?? (4) 26.0 (11.800) with lc3d115 ?? a64 (4) 26.7 (12.100) 75 132 132 147 ? 1 1 ? (3) ? 1 (3) without lc3d150 ?? (4) 26.7 (12.100) with lc3d150 ?? a64 (4) 26.7 (12.100) rail mounted (35 mm din rail) maximum operating rate: 12 starts/hour. maximum starting time: 30 seconds. 3 5.5 5.5 5.5 ? ? ? ? ? 1 with lc3k06 ?? 1.6 (0.740) 4 7.5 7.5 7.5 ? ? ? ? ? 1 with lc3k09 ?? 1.6 (0.740) maximum operating rate: 30 starts/hour. maximum starting time: 30 seconds. 4 7.5 7.5 7.5 ? ? ? ? (3) ? 1 with lc3d090a ?? 3.4 (1.530) 5.5 11 11 11 ? ? ? ? (3) ? 1 with lc3d120a ?? 3.4 (1.530) 11 18.5 22 22 ? ? ? ? (3) ? 1 with lc3d180a ?? 3.8 (1.730) 15 25 30 30 ? ? ? ? (3) ? 1 with lc3d320a ?? 4.5 (2.030) (1) protection must be provided by the addition of an overload relay, to be ordered separately. select appropriate overload rela y for setting at 0.58 of the full load rated motor current (see pages 134 and 135). (2) standard control circuit voltages volts ac 50/60 hz 24 36 42 48 110 220 230 240 380 400 415 440 wye-delta starters lc3k06 and k09 code b7 c7 d7 e7 f7 m7 p7 u7 ? v7 n7 r7 wye-delta starters lc3d09a to d150, lc3d090a to d320a code b7 ? d7 e7 f7 m7 p7 u7 q7 v7 n7 r7 for other voltages, please consult your regional sales office. (3) one auxiliary contact block type ladn can also be installed, see page 107. (4) these starters consist of contactors lc1d115 or d150 without connectors. lc3d32a kk
tesys? d-line contactors and starters ac wye-delta starters lc3d (international applications only) 147 01/04 ? 2001-2004 schneider electric all rights reserved wye-delta starting current this method of starting is applicable to motors on which all six stator terminals are accessible and whose delta connection voltage corresponds to the mains voltage. wye-delta starting should be used for motors starting on no-load or having a low load torque and gradual build-up: the starting torque in star connection is reduced to one third of the direct starting torque, i.e. about 50% of the rated torque; the starting current in star connection is about 1.8 to 2.6 times the rated current. the transition from wye to delta connection must occur when the machine has run up to speed. a too rapid build-up in load torque would cause the stabilized run-up speed to be too low and would therefore eliminate any advantage in this method of starting: this is the case with certain machines whose load torque depends on the machine speed (a characteristic of centrifugal machines, for example). all wye-delta starters are supplied with a special la2ds2 or la2kt2 k time delay relay which imposes a delay on the delta contactor during the transition period in order to allow the star contactor sufficient breaking time. for ratings d115 and d150, this function is performed by a time delay auxiliary contact block la2dt2 and a control relay. speed 1 starting in direct delta connection 2 starting in wye connection torque speed 1 starting in direct delta connection 2 starting in star connection 3 machine resistive torque (1) motor manufacturers generally specify machine load torques. example: maximum resistive torque on completion of star-delta start (expressed as a proportion of the rated torque). 0 1 2 3 4 5 6 7 0 0,25 0,50 0,75 1 1 2 0 0,5 0 0,25 0,50 0,75 1 1 2 3 (1) 1 1,5 2 2,5
tesys? d-line contact ors and starters ac wye-delta starter kits (international applications only) ? 2001-2004 schneider electric all rights reserved 148 01/04 ac wye-delta starter kits (international applications only) km2 km2 km2 km1 km 3 1c 1c 2 1a 1b a a a a 1d 1b a
tesys? d-line contactors and starters ac wye-delta starter kits (international applications only) 149 01/04 ? 2001-2004 schneider electric all rights reserved wye-delta starters, for motor control, 7.5 to 13 2 kw (1), without mech anical interlock, for customer assembly (on plate or on mounting rail) (2) - references starters for direct combination with circuit-breaker maximum operating rate: 30 starts/hour. maximum starting time: 30 seconds standard power ratings of squirrel cage motors (3) mains voltage-delta motor thermal- magnetic mcb catalog number complete with code indicating control circuit voltage (4) 400/415 v kw 440 v kw line delta star km2 km3 km1 7.5 7.5 gv2me20 lc1d09 ?? lc1d09 ?? lc1d09 ?? ?9 gv2me20 lc1d12 ?? lc1d12 ?? lc1d09 ?? 911 gv2me21 lc1d12 ?? lc1d12 ?? lc1d09 ?? 11 ? gv2me22 lc1d18 ?? lc1d18 ?? lc1d09 ?? 15 15 gv2me32 lc1d18 ?? lc1d18 ?? lc1d09 ?? separate parts description illustrati on item no. catalog number weight lb. (kg) mounting kit comprising: power circuit connections and 1 time delay contact block lads2 a lad912gv 0.29 (0.130) starters for mounting separate ly from upstream protection maximum operating rate : 30 starts/hour. maximum starting time: 30 seconds standard power ratings of squirrel cage motors (3) mains voltage-delta contactors (basic references to be completed with code indicating the voltage) (4) separate parts (see below) 220/230 v 380/400 v 415 v 440 v line delta star kw kw kw kw km2 km3 km1 component type 4 7.5 7.5 7.5 lc1d09 ?? lc1d09 ?? lc1d09 ?? d09 5.5 11 11 11 lc1d12 ?? lc1d12 ?? lc1d09 ?? d12 11 18.5 22 22 lc1d18 ?? lc1d18 ?? lc1d09 ?? d18 15 25 30 30 lc1d32 ?? lc1d32 ?? lc1d18 ?? d32 18.5 37 37 37 lc1d40 ?? lc1d40 ?? lc1d40 ?? d40 30 55 59 59 lc1d50 ?? lc1d50 ?? lc1d40 ?? d50 37 75 75 75 lc1d80 ?? lc1d80 ?? lc1d50 ?? d80 63 110 110 110 lc1d115 ?? lc1d115 ?? lc1d80 ?? d115 75 132 132 147 lc1d150 ?? lc1d150 ?? lc1d115 ?? d150 separate parts description illustration item no. for use on catalog number weight lb. (kg) mounting kit comprising: - 1 time delay contact block lads2 (d09 to d80) (3) - power circuit connections (d09 to d80) - screws and clamps for attaching contactors to the plate (d40 to d80) - terminal block (d09 to d32) 1 a 1 b 1 c 1 d d09 to d18 lad91217 0.40 (0.180) d32 lad93217 0.65 (0.310) d40 la9d4017 0.83 (0.380) d50 la9d5017 1.06 (0.480) d80 la9d8017 1.5 (0.680) equipment mounting plate 2 d09, d12, d18 la9d12974 0.33 (0.150) d32 la9d32974 0.40 (0.180) d40 and d50 la9d40973 0.66 (0.300) d80 la9d80973 0.66 (0.300) (1) protection must be provided by the addition of a thermal overload relay, to be ordered separately. select appropriate overlo ad relay for setting at 0.58 of the rated motor current, see pages 134 and 135. (2) for mounting, assembly and cabling: refer to installation instructions supplied with the equipment. (3) see comments on page 147. (4) see page 115.
tesys? d-line contact ors and starters ac wye-delta starter kits (international applications only) ? 2001-2004 schneider electric all rights reserved 150 01/04 wye-delta starters - dimensions, schematics dimensions for wye-delta starters on mounting rail am1-dp, pre-assembled lc3-d090a to d320a lc3 d090a to d180a d320a b 6.0 (153) 5.6 (137) c with lad-s 5.4 (139) 5.9 (145) with lad-s and sealing cover 5.8 (143) 5.8 (149) schematics lc3-k, lc3-d09a to d80 / lc3d090a to d320a lc3-k lc3-d (1) recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end) for lc3d50, d80 lc3-d115 and d150 (1) recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end) c b 2x?0.28 6.30 6.89 km2 km3 km1 2x?7 160 175 u1 v1 w1 u2 v2 w2 2 4 6 ? km2 1 2 3 4 5 6 ? km3 1 2 3 4 5 6 ? km1 1 2 3 4 5 6 u1 v1 w1 u2 v2 w2 1 3 5 2 4 6 l1 l2 l3 (1) lc3-d09a to d18a: mechanical interlock between km3 and km1 km2 : 1 (n) o t t i y l km3 : 5 ? km3 ? km2 ? km1 ? km1 54 53 a1 a2 a1 a2 a1 a2 a1 a2 ? km1 ? km3 21 22 22 21 15 16 95 96 ? km2 14 13 a1 a2 ? km1 13 14 21 22 22 21 ? km3 55 56 ? km2 53 54 ? km1 95 96 km3/5 o l 68 67 ? km2 a1 a2 ? km3 22 21 ? km1 a1 a2 ? km2 13 14 ? km2 (13) (14) km3/1 n u1 v1 w1 u2 v2 w2 2 4 6 ? km2 1 2 3 4 5 6 ? km3 1 2 3 4 5 6 ? km1 1 2 3 4 5 6 u1 v1 w1 u2 v2 w2 1 3 5 2 4 6 l1 l2 l3 (1) a1 a2 ? km1 13 14 21 22 162 161 ? km3 55 56 ? km2 184 183 ? km1 95 96 ? f1 ? f1 o l 153 154 ? km2 a1 a2 ? ka1 a1 a2 ? km2 153 154 ? km1 ? f2 171 67 68 ? km2 172 ? km1 13 14 a1 a2 ? km3 ? ka1 y l
tesys? d-line contactors and starters enclosed contactors and starters 151 01/04 ? 2001-2004 schneider electric all rights reserved enclosed contactors and starters horsepower ratings for north american applicat ions of d-line products in metal enclosures note: use of control circuit transformers requires insta-kit wiring. 1. control power transformer: select letter from below for primary voltage of cpt. 2. contactor/starter coil voltage: select coil voltage from table below. note: if control transformer is used, the only options available are 24 or 120 volts as the secondary of the transformer. 3. coil frequency: select: 7 = dual frequency coils (50/60 hz), 6 = 60 hz. note: for 9 to 32 a contactors, only dual frequency co ils are available. for 40 to 80 a contactors, the 24 v to 240 v coils are dual frequency only (50/60 hz.). the 480 v to 600 v coils are 60 hz. only. 4. overload relay type: select: 0 = no overload relay, 1 = trip class 10, 2 = trip class 20. 5. overload relay range: select code from page 152. note: if no overload relay is required, leave this portion of the catalog number blank. d-line enclosed full voltage starters are available in type 1 and type 12/3r enclosures through 50 hp at 460 vac. see pages 106 to 112 for a complete selection of d-line accessories. see page 155 for insta-kit accessories. e154118 ccn nldx ccn nldx7 lr23506 41 class 3211 04 enclosed full voltage non-reversing starters max. horsepower ratings (ac3) auxiliary contacts current rating of contactor catalog number weight kg (lb.) catalog number weight kg (lb.) 3 phase 200 v 230 v 460 v 575v n.o. n.c. type 1 type 12/3r 22 5 7 1 / 2 1 ... 9 le1d093a62(1)(2)(3)(4)(5) 3.1 (6.9) le1d093a72(1)(2)(3)(4)(5) 3.5 (7.7) 33 7 1 / 2 10 1 ... 12 le1d123a62(1)(2)(3)(4)(5) 3.1 (6.9) le1d123a72(1)(2)(3)(4)(5) 3.5 (7.7) 5 5 10 15 1 ... 18 le1d183a62(1)(2)(3)(4)(5) 3.1 (6.9) le1d183a72(1)(2)(3)(4)(5) 3.5 (7.7) 57 1 / 2 15 20 1 ... 25 le1d253a62(1)(2)(3)(4)(5) 3.3 (7.3) le1d253a72(1)(2)(3)(4)(5) 3.6 (8.1) 7 1 / 2 10 20 25 1 ... 32 le1d323a62(1)(2)(3)(4)(5) 3.3 (7.3) le1d323a72(1)(2)(3)(4)(5) 3.6 (8.1) 10 10 30 30 1 1 40 le1d403a62(1)(2)(3)(4)(5) 5.1 (11.4) le1d403a72(1)(2)(3)(4)(5) 5.5 (12.3) 10 15 30 40 1 1 50 le1d503a62(1)(2)(3)(4)(5) 5.1 (11.4) le1d503a72(1)(2)(3)(4)(5) 5.5 (12.3) 15 20 40 50 1 1 65 le1d653a62(1)(2)(3)(4)(5) 7.4 (16.5) le1d653a72(1)(2)(3)(4)(5) 7.8 (17.4) 20 20 50 60 1 1 80 le1d803a62(1)(2)(3)(4)(5) 7.6 (16.8) le1d803a72(1)(2)(3)(4)(5) 8.0 (17.8) enclosed full voltage reversing starters max. horsepower ratings (ac3) 3 phase auxiliary contacts current rating of contactor catalog number weight kg (lb.) catalog number weight kg (lb.) 200 v 230 v 460 v 575 v n.o. n.c. type 1 type 12/3r 225 7 1 / 2 2 2 9 le2d093a62(1)(2)(3)(4)(5) 4.5 (10) le2d093a72(1)(2)(3)(4)(5) 4.9 (10.8) 337 1 / 2 10 2 2 12 le2d123a62(1)(2)(3)(4)(5) 4.5 (10) le2d123a72(1)(2)(3)(4)(5) 4.9 (10.8) 5 5 10 15 2 2 18 le2d183a62(1)(2)(3)(4)(5) 4.5 (10) le2d183a72(1)(2)(3)(4)(5) 4.9 (10.8) 57 1 / 2 15 20 2 2 25 le2d253a62(1)(2)(3)(4)(5) 4.5 (10) le2d253a72(1)(2)(3)(4)(5) 4.9 (10.8) 7 1 / 2 10 20 25 2 2 32 le2d323a62(1)(2)(3)(4)(5) 4.5 (10) le2d323a72(1)(2)(3)(4)(5) 4.9 (10.8) 10 10 30 30 2 2 40 le2d403a62(1)(2)(3)(4)(5) 4.5 (10) le2d403a72(1)(2)(3)(4)(5) 4.9 (10.8) 10 15 30 40 2 2 50 le2d503a62(1)(2)(3)(4)(5) 4.5 (10) le2d503a72(1)(2)(3)(4)(5) 4.9 (10.8) 15 20 40 50 2 2 65 le2d653a62(1)(2)(3)(4)(5) 4.5 (10) le2d653a72(1)(2)(3)(4)(5) 4.9 (10.8) 20 20 50 60 2 2 80 le2d803a62(1)(2)(3)(4)(5) 4.5 (10) le2d803a72(1)(2)(3)(4)(5) 4.9 (10.8) control power transformer primary voltage code table voltage no transformer used 208 240 480 600 code o l m t x contactor coil voltage table voltage 24 120 208 240 480 600 ac bgl utx
tesys? d-line contact ors and starters enclosed iec non-combination starters ? 2001-2004 schneider electric all rights reserved 152 01/04 enclosed iec non-combination starters q available in class 10 only c available in class 20 only note: use of control circuit transf ormers requires insta-kit wiring. 1. control power transformer: select letter from below for primary voltage of cpt. 2. contactor/starter coil voltage: sele ct coil voltage from table below. note: if control transformer is used, the only options available are 24 or 120 volts as the secondary of the transformer. 3. coil frequency: select: 7 = dual frequency for all starter coil selections except for 480 v or 600 v coils, on 40 a - 80 a starters select 6, 60 hz only. 4. overload relay type: select: 0 = no overload relay, 1 = trip class 10, 2 = trip class 20. 5. overload relay range: select code from page 155. note: if no overload relay is required, leave this portion of the catalog number blank. enclosed starter overload relay selection table code range for use on contactors 01 0.1?0.16 lc1d09?d32 q 02 0.16?0.25 lc1d09?d32 q 03 0.25?0.40 lc1d09?d32 q 04 0.40?0.63 lc1d09?d32 q 05 0.63?1.0 lc1d09?d32 q 06 1.0?1.6 lc1d09?d32 q 07 1.6?2.5 lc1d09?d32 q 08 2.5?4 lc1d09?d32 10 4?6 lc1d09?d32 12 5.5?8 lc1d09?d32 14 7?10 lc1d09?d32 16 9?13 lc1d12?d32 21 12?18 lc1d18?d32 22 16?24 q 17-25 c lc1d25?d32 q lc1d40-80 c 30 23-28 lc1d25?d32 c 32 25-32 q 23?32 c lc1d25?d32 53 30?38 lc1d40?d80 55 30?40 lc1d40?d80 57 37?50 lc1d40?d80 59 48?65 lc1d40?d80 61 55?70 lc1d40?d80 63 63?80 lc1d40?80 control power transformer primary voltage code table voltage no transformer used 208 240 480 600 code o l m t x contactor coil voltage table voltage 24 120 208 240 480 600 ac bgl utx le2d093a62
tesys? d-line contactors and starters enclosed iec combination starters 153 01/04 ? 2001-2004 schneider electric all rights reserved enclosed iec combination starters horsepower ratings for nort h american applications of d-line products in metal enclosures with fusible disconnect switch or circuit breaker iec combination starters combine the requirements of motor overload and short circuit protection in one convenient compact package. all devices provide type 2 coordination through 30 hp at 460 v. devices are available in type 1 and type 12/3r enclosures. note: use tables and notes from page 152 to complete the catalog numbers. see pages 106 to 112 for a complete selection of d-line accessories. see page 155 for insta-kit accessories. e154118 ccn nldx ccn nldx7 lr23506 41 class 3211 04 enclosed full voltage non-reversi ng fusible combination starters max. horsepower ratings (ac3) fuse clip rating auxiliary contacts current rating of contactor catalog number weight kg (lb.) catalog number weight kg (lb.) 3 phase 200 v 230 v 460 v 575 v amperes ul class n.o. n.c. type 1 type 12/3r 2257 1 / 2 30 a cc 1 ... 9 le1d096b62(1)(2)(3)(4)(5) 8.1 (18) le1d096b72(1)(2)(3)(4)(5) 8.1 (18) 337 1 / 2 10 30 a cc 1 ... 12 le1d126b62(1)(2)(3)(4)(5) 8.1 (18) le1d126b72(1)(2)(3)(4)(5) 8.1 (18) 5 5 10 15 30 a j 1 ... 18 le1d186b62(1)(2)(3)(4)(5) 8.1 (18) le1d186b72(1)(2)(3)(4)(5) 8.1 (18) 57 1 / 2 15 20 30 a j 1 ... 25 le1d256b62(1)(2)(3)(4)(5) 8.1 (18) le1d256b72(1)(2)(3)(4)(5) 8.1 (18) 7 1 / 2 10 20 25 60 a j 1 ... 32 le1d326c62(1)(2)(3)(4)(5) 11.7 (26) le1d326c72(1)(2)(3)(4)(5) 11.7 (26) 10 10 30 30 60 a j 1 1 40 le1d406c62(1)(2)(3)(4)(5) 12.6 (28) le1d406c72(1)(2)(3)(4)(5) 12.6 (28) enclosed full voltage reversin g fusible combination starters max. horsepower ratings (ac3) fuse clip rating auxiliary contacts current rating of contactor catalog number weight kg (lb.) catalog number weight kg (lb.) 3 phase 200 v 230 v 460 v 575 v amperes ul class n.o. n.c. type 1 type 12/3r 2257 1 / 2 30 a cc 2 2 9 le2d096b62(1)(2)(3)(4)(5) 11.7 (26) le2d096b72(1)(2)(3)(4)(5) 11.7 (26) 337 1 / 2 10 30 a cc 2 2 12 le2d126b62(1)(2)(3)(4)(5) 11.7 (26) le2d126b72(1)(2)(3)(4)(5) 11.7 (26) 5 5 10 15 30 a j 2 2 18 le2d186b62(1)(2)(3)(4)(5) 11.7 (26) le2d186b72(1)(2)(3)(4)(5) 11.7 (26) 57 1 / 2 15 20 30 a j 2 2 25 le2d256b62(1)(2)(3)(4)(5) 11.7 (26) le2d256b72(1)(2)(3)(4)(5) 11.7 (26) 7 1 / 2 10 20 25 60 a j 2 2 32 le2d326c62(1)(2)(3)(4)(5) 12.2 (27) le2d326c72(1)(2)(3)(4)(5) 12.2 (27) 10 10 30 30 60 a j 2 2 40 le2d406c62(1)(2)(3)(4)(5) 14.0 (31) le2d406c72(1)(2)(3)(4)(5) 14.0 (31) enclosed full voltage non-reversing circuit breaker combination starters max. horsepower ratings (ac3) auxiliary contacts circuit breaker maximum current rating current rating of contactor catalog number weight kg (lb.) catalog number weight kg (lb.) 3 phase 200 v 230 v 460 v 575 v n.o. n.c. type 1 type 12/3r 2257 1 / 2 1 - 15 a 9 le1d097d62(1)(2)(3)(4)(5) 9.0 (20) le1d097d72(1)(2)(3)(4)(5) 9.0 (20) 337 1 / 2 10 1 - 15 a 12 le1d127d62(1)(2)(3)(4)(5) 9.0 (20) le1d127d72(1)(2)(3)(4)(5) 9.0 (20) 5 5 10 15 1 - 30 a 18 le1d187e62(1)(2)(3)(4)(5) 9.0 (20) le1d187e72(1)(2)(3)(4)(5) 9.0 (20) 57 1 / 2 15 20 1 - 30 a 25 le1d257e62(1)(2)(3)(4)(5) 9.0 (20) le1d257e72(1)(2)(3)(4)(5) 9.0 (20) 7 1 / 2 10 20 25 1 - 50 a 32 le1d327f62(1)(2)(3)(4)(5) 12.2 (27) le1d327f72(1)(2)(3)(4)(5) 12.2 (27) 10 10 30 30 1 1 50 a 40 le1d407f62(1)(2)(3)(4)(5) 13.0 (29) le1d407f72(1)(2)(3)(4)(5) 13.0 (29) enclosed full voltage reversing circuit breaker combination starters max. horsepower ratings (ac3) auxiliary contacts circuit breaker maximum current rating current rating of contactor catalog number weight kg (lb.) catalog number weight kg (lb.) 3 phase 200 v 230 v 460 v 575 v n.o. n.c. type 1 type 12/3r 2257 1 / 2 2 2 15 a 9 le2d097d62(1)(2)(3)(4)(5) 10.8 (24) le2d097d72(1)(2)(3)(4)(5) 10.8 (24) 337 1 / 2 10 2 2 15 a 12 le2d127d62(1)(2)(3)(4)(5) 10.8 (24) le2d127d72(1)(2)(3)(4)(5) 10.8 (24) 5 5 10 15 2 2 30 a 18 le2d187e62(1)(2)(3)(4)(5) 12.6 (28) le2d187e72(1)(2)(3)(4)(5) 12.6 (28) 57 1 / 2 15 20 2 2 30 a 25 le2d257e62(1)(2)(3)(4)(5) 12.6 (28) le2d257e72(1)(2)(3)(4)(5) 12.6 (28) 7 1 / 2 10 20 25 2 2 50 a 32 le2d327f62(1)(2)(3)(4)(5) 12.6 (28) le2d327f72(1)(2)(3)(4)(5) 12.6 (28) 10 10 30 30 2 2 50 a 40 le2d407f62(1)(2)(3)(4)(5) 14.4 (32) le2d407f72(1)(2)(3)(4)(5) 14.4 (32)
tesys? d-line contact ors and starters enclosed iec combination starters ? 2001-2004 schneider electric all rights reserved 154 01/04 q available in class 10 only c available in class 20 only note: use of control circuit transf ormers requires insta-kit wiring. 1. control power transformer: select letter from below for primary voltage of cpt. 2. contactor/starter coil voltage: sele ct coil voltage from table below. note: if control transformer is used, the only options available are 24 or 120 volts as the secondary of the transformer. 3. coil frequency: select: 7 = dual frequency for all starter coil selections except for 480 v or 600 v coils, on 40 a - 80 a starters select 6, 60 hz only. 4. overload relay type: select: 0 = no overload relay, 1 = trip class 10, 2 = trip class 20. 5. overload relay range: select code from page 155. note: if no overload relay is required, leave this portion of the catalog number blank. enclosed starter overload relay selection table code range for use on contactors 01 0.1?0.16 lc1d09?d32 q 02 0.16?0.25 lc1d09?d32 q 03 0.25?0.40 lc1d09?d32 q 04 0.40?0.63 lc1d09?d32 q 05 0.63?1.0 lc1d09?d32 q 06 1.0?1.6 lc1d09?d32 q 07 1.6?2.5 lc1d09?d32 q 08 2.5?4 lc1d09?d32 10 4?6 lc1d09?d32 12 5.5?8 lc1d09?d32 14 7?10 lc1d09?d32 16 9?13 lc1d12?d32 21 12?18 lc1d18?d32 22 16?24 lc1d25?d32 30 23-28 lc1d25?d32 c 32 23?32 lc1d25?d32 53 30?38 lc1d40?d80 55 30?40 lc1d40?d80 57 37?50 lc1d40?d80 59 48?65 lc1d40?d80 61 55?70 lc1d40?d80 control power transformer primary voltage code table voltage no transformer used 208 240 480 600 code o l m t x contactor coil voltage table voltage 24 120 208 240 480 600 ac bgl utx le1d406c72 le1d097d62
tesys? d-line contactors and starters enclosed iec combination starters 155 01/04 ? 2001-2004 schneider electric all rights reserved factory modifications and insta-kit selection add the factory modification code to the end of the catalog number created from pages 151 and 152. only one operator scheme (factory modification c ode or field-installable insta-kit option) can be used. only the combinations of operators and pilot lights shown below ca n be ordered. pilot lights will be at t he coil voltage indicated in the catalog number for the starter. q add these forms to the catalog number selected on pages 151 or 152. the numbers as shown are for use in nema 1 enclosures. for uses in nema 12/3r change the 6 to a 7 (ex a06u becomes a07u). the change does not apply to control power transformer forms or insta-kits. c pilot lights are wired such that the light is on when the contactor is energized. for non-led type pilot lights, a green lens i s installed on the unit when shipped. a red lens is included for use as applicable. f select insta-kit from table below. a complete the catalog number for the insta-kit by selecting the voltage code from the appropriate tables below. k 3-wire adapter required when start/stop pushbutton remote station is used in conjunction with start/stop local control or if lo cal pilot light only is used. 4-wire adapter required when for/rev/stop is required for both local and remote control. 5-wire adapter required when start/stop pushbutton with pilot light remote station or pilot light only remote is used with star t/stop pushbutton local control. 7-wire adapter required for remote control only applications. la9ff4tk all others e61239 ccn xptq ccn xptq7 e154118 ccn nldx ccn nldx7 lr23506 41 class 3211 04 description factory modification code q insta-kits (for field installation) control units only for-rev-stop push button a06l la9ca06lt start/stop push button a06g la9ca06gt i/o (start/stop) push button n/a n/a i/o push button (double touch) a06i la9ca06io emergency stop n/a n/a start / mushroom head stop push button a06x la9ca06xt hand-off-auto selector switch a06e la9ca06et on/off selector switch a06d la9ca06dt pilot lights only led pilot light, 24, 120 or 240 v a16s la9ca16st a green-red pilot light, 120 v c a06s la9ca06st green-red transformer pilot light, 120, 208/240, 480 or 600 v c a06f la9ca06ft a available combination of control units and pilot lights hand-off-auto selector switch, 120 v led pilot light a16u la9ca16ut a start/stop push button w/ 24, 120 or 240 v led pilot light a16v la9ca16vt a on/off selector w/ 24, 120 or 240 v led pilot light a16w la9ca16wt a start/stop push button w/ green-red transformer pilot light a06n la9ca06nt a start/stop push button w/green-red pilot light a06g la9ca06vt hand-off-auto selector switch w/green-red pilot light 120 v a06u la9ca06ut hand-off-auto selector switch w/green- red transformer pilot light a06j la9ca06jt a on/off selector w/green-red pilot light a06w la9ca06wt on/off selector w/green-red transformer pilot light a06h la9ca06ht a control power transformer standard va, 2 fuses in primary, 1 fuse in secondary a206p f 50 va extra, 2 fuses in primary, 1 fuse in secondary a207p f 100 va extra, 2 fuses in primary, 1 fuse in secondary a208p f local / remote adapter, 3-wire kC la9aadis3 local / remote adapter, 4-wire kC la9aadis4 local / remote adapter, 5-wire kC la9aadis5 local / remote adapter, 7-wire kCla9aadis7 total va insta-kit catalog number weight / kg (lb.) 50 la9tfd32 a 0.80 (1.75) 100 la9tfd80 a 1.45 (3.25) voltage codes for pilot lights voltage (vac) 24 120 208/240 480 600 code b g m t x voltage codes for control power transformers primary voltage 120 208 240 480 600 208 240 480 600 secondary voltage 24 120 code edcbal mt x l1 l2 pl m off on 1234a b olr 95 96 x1 x2 pl 61 62 x1 x2 on-off selector switch h-o-a selector switch l1 l2 m hand auto off pl x1 x2 34 34 95 96 61 62 pl x1 x2 remote by customer connection l1 l2 start stop 12 ab 34 m 95 96 13 14 olr start/stop
tesys? d-line contact ors and starters dimensions for enclosed combination and non-combination iec starters ? 2001-2004 schneider electric all rights reserved 156 01/04 dimensions for enclosed combination and non-combination iec starters combination starter dime nsions with rotary disconnect handle - type 1 type 12 7.5 191 0.6875 17 8 203 3 76 14 356 12.5 318 a a b c b 5 127 16.5 419 7.5 191 10 254 18 457 a a b c b r r provision for 1/4 in. screw / provisin para el tornillo de 1/4 / option pour vis de 6,3 mm (1/4 po) d09-25 (fvnr) d09-40 (fvr); d32-40 (fvnr) knockout schedule knockout conduit size, in. (mm) a 0.50 (12.7) b 1.00 (25.4); 1.25 (31.8) c 0.50 (12.7); 0.75 (19.05) dual dimensions: inches mm 7.75 197 provision for 1/4 in. screw / provisin para el tornillo de 1/4 / option pour vis de 6,3 mm (1/4 po) 19.625 498 5 127 18.875 479 7.75 197 18 457 14 356 15.625 397 14.875 378 8 203 3 76 10 254 r r d09-40 (fvr); d32-40 (fvnr) r .56 14 d d/2 provision for 1/4" screw c .75 19 fgh b e a .50 13 j k non-combination st arter dimensions type 1 type 12/3r non- reversing reversing a b c d e f g h j k d e d09-25 ... 6.77 172 10.04 255 6.25 158 5.38 136 9.00 228 1-1 1 / 4 25.4-31.7 1 / 2 - 3 / 4 12.7-19 ? 1- 1 / 4 25.4-6.3 1 / 2 - 3 / 4 12.7-19 5.38 13.6 11.37 288 d32-50 d09-32 8.66 220 10.83 275 7.21 183 7.25 184 9.75 247 1 1 / 4 -1 1 / 2 31.7-38.1 1 / 2 - 3 / 4 12.7-19 1-1 1 / 4 25.4-31.7 1- 1 / 4 25.4-6.3 1 / 2 - 3 / 4 12.7-19 5.38 13.6 12.15 308 d65-80 d40-80 10.63 270 13.98 355 7.21 183 9.22 234 12.94 328 1 1 / 4 -1 1 / 2 31.7-38.1 1 / 2 - 3 / 4 12.7-19 1-1 1 / 4 25.4-31.7 1-1 1 / 4 25.4-6.3 1 / 2 - 3 / 4 12.7-19 5.38 13.6 15.30 385 d09-25 (fvnr)
tesys? d-line contactors and starters schematics for enclosed iec non-combination starters 157 01/04 ? 2001-2004 schneider electric all rights reserved schematics for enclosed iec non-combination starters non-reversing, non-combination 3-phase starter reversing, non-combination 3-phase starter ol / sc reset brown yellow white plug-in connector plug-in connector jumper jumper reset ol / sc wire 4 wire 3
tesys? d-line contact ors and starters schematics for enclosed iec combination starters ? 2001-2004 schneider electric all rights reserved 158 01/04 schematics for enclosed iec combination starters non-reversing, combination 3-phase starter reversing, combination 3-phase starter ol / sc reset brown yellow white plug-in connector plug-in connector jumper jumper reset ol / sc wire 4 wire 3
tesys? d-line contactors and starters enclosed contactors le1d and le2d 159 01/04 ? 2001-2004 schneider electric all rights reserved international applications only enclosed contactors le1d (international applications only) d.o.l. ac starters for motor control (1 ) 2.2 to 45 kw, without isolator device non-reversing starters (1) protection must be provided by addition of an overload relay, to be ordered separately, see pages 134 and 135. (2) avoid placing this material in contact with harsh substanc es (detergents, chlorinated solvents, ketones, alcohol, aromatic hydrocarbons). (3) standard control circuit voltages. (4) selection according to the number of operating cycles, please consult your regional sales office. characteristics conforming to standards iec 60947-4-1 and iec 60439-1, vde 0660-102, en 60947 degree of protec tion to iec 60529 ip 659: le2k , ip 657: le p d09 to d35 and ip 557: le p d405 to d955 ambient air temperature for operation: - 5 to + 40 c (- 41 to + 104 f) operating positions identical to positions for contactors material poly carbonate (2): le2k and le p d09 to d35 . sheet steel: le p d405 to d955 standard power ratings of 3-phase motors 50/60 hz in category ac-3 (kw) maximum current i the up to catalog number, complete with control circuit voltage code (3) standard voltag e s weight lbs (kg) 220 230 v 380 400 v 415v 440 v 500 v 660 690 v 2.24445.55.5 9le1do9 f7 p7 v7 2.03 (0.92) 3 5.5 5.5 5.5 7.5 7.5 12 le1d12 f7 p7 v7 2.03 (0.92) 47.5991010 18 le1d18 f7 p7 v7 2.24 (1.015) 5.51111111515 25 le1d25 f7 p7 v7 2.24 (1.015) 7.515151518.518.5 35 le1d35 f7 p7 v7 9.53 (4.320) 11 18.5 22 22 22 30 40 le1d405 f7 p7 v7 10.63 (4.82) 15 22 25 30 30 33 50 le1d505 f7 p7 v7 10.69 (4.85) 18.5 30 37 37 37 37 65 le1d655 f7 p7 v7 10.69 (4.85) 22 37 45 45 55 45 80 le1d805 f7 p7 v7 11.33 (5.14) 25 45 45 45 55 45 95 le1d955 f7 p7 v7 12.0 (5.44) reversing starters 1.52.22.23 ? ? 6le2k065 f7 p7 v7 2.38 (1.08) 2.2444?? 9 le2k095 f7 p7 v7 2.38 (1.08) le2d09 f7 p7 v7 4.63 (2.100) ????5.55.5 9le2d09 f7 p7 v7 4.63 (2.100) 3 5.5 5.5 5.5 7.5 7.5 12 le2d12 f7 p7 v7 4.63 (2.100) 47.5991010 18 le2d18 f7 p7 v7 5.31 (2.410) 5.51111111515 25 le2d25 f7 p7 v7 5.66 (2.570 7.515151518.518.5 35 le2d35 f7 p7 v7 9.0 (4.100) 11 18.5 22 22 22 30 40 le2d405 f7 p7 v7 11.6 (5.270) 15 22 25 30 30 33 50 le2d505 f7 p7 v7 12.06 (5.470) 18.5 30 37 37 37 37 65 le2d655 f7 p7 v7 12.06 (5.470) 22 37 45 45 55 45 80 le2d805 f7 p7 v7 14.77 (6.700) 25 45 45 45 55 45 95 le2d955 f7 p7 v7 15.43 (7.000) volts ac 50/60 hz 24 42 48 110 115 220 230 240 380 400 415 440 le2k b7d7e7f7? m7p7u7q7v7n7r7 le1, le2d b7 d7 e7 f7 fe7 m7 p7 u7 q7 v7 n7 r7 for other voltages please consult your regional sales office. le1d12 le2d12
tesys? d-line contact ors and starters enclosed contactors le1d and le2d ? 2001-2004 schneider electric all rights reserved 160 01/04 d.o.l. ac starters for motor control (1) 2.2 to 45 kw without isolator device, non-reversing (1) see previous page. (2) example: le1d093f7a04 other versions: combination of 2 accessories, please consult your regional sales office. description standard versions comprise:  for non-reversing starters: 1 green start button ?i?, 1 red stop/reset button ?o?.  for reversing starters: ?le2k: 1 start button a , 1 start button e , 1 red stop/reset button. ? le2d09 to d35: 1 2-position spring return selector switch ?i?-?ii?, 1 red stop/reset button ?o?. ? le2d405 to d955: 1 blue reset button ?r?. forms (installed by telemecanique) description for use on suffix to be added to starter catalog number (2) no push buttons on cover le1d09 through d955 le2d09 through d955 a04 1 green start button ?i? 1 green start button ?ii? 1 red stop/reset button ?o? le2d405 through d955 a11 1 blue reset button ?r? le1d09 through d955 le2k06 and k09 le2d09 through d35 a05 1 3-position stay put selector switch (?i?-?o?-?ii?) (?i?: automatic start; ?o?: stop; ?ii?: manual start) 1 blue reset button ?r? le1d09 through d35 a09 1 2-position stay put selector switch (?o?-?i?) (?o?: stop; ?i?: manual start) 1 blue reset button ?r? le1d09 through d35 a13 1 3-position stay put selector switch ?o?-?i? with spring return to center position (?i?: manual start; ?o?: stop, stay put) 1 blue reset button ?r? le1d09 through d35 a35 1 neutral terminal fitted as standard on le1 and le2d18 to d955 starters ordered with 220 v (m7), 230 v (p7) or 240 v (u7) control circuit voltage. le1d09 through d955 le2k06 and k09 le2d09 through d955 a59 accessories (installed by the customer) description for use on catalog number weight lbs (kg) start pushbutton latching device for stay-put operation (start-stop) le1d405 through d955 la9d09907 0.13 (0.06) le1d12a04 le1d12a09 le1d12a13 le1d12a05 le1d12a35
tesys? d-line contactors and starters enclosed contactors with fused disconnect switch le2, le4, and le8 161 01/04 ? 2001-2004 schneider electric all rights reserved international applications only enclosed contactors with fused disconnect switch le4k/d (international application only) d.o.l. ac starters for motor control (1 ), 2.2 to 45 kw with isolator device non-reversing starters (1) protection must be provided by addition of an overload relay, to be ordered separately, see pages 134 and 135. (2) avoid placing this material in contact with harsh substanc es (detergents, chlorinated solvents, ketones, alcohol, aromatic hydrocarbons). (3) standard control circuit voltages. (4) selection according to dimensions and the number of ope rating cycles, please consult your regional sales office. (5) supplied with 3 cable entries. characteristics conforming to standards iec 60947-4-1 and iec 60439-1, vde 0660-102, en 60947 degree of protection to iec 529 ip 659: le p k , ip 657: le p d09 to d35 and ip 55: le p d406 to d806 ambient air temperature for operation: - 5 to + 40 c (- 41 to + 104 f) operating positions identical to positions for contactors material poly carbonate (2): le p k and le p d09 to d35 . sheet steel: le p d406 to d806 standard power ratings of 3-phase motors 50/60 hz in category ac-3 (kw) operational current (a) 440 v up to fuses to be fitted by the customer catalog number, complete with control circuit voltage code (3) weigh lbs (kg) 220 230 v 380 400 v 415v 440 v 500 v 660 690 v size type am a 1.5 2.2 2.2 3 - - 6 10 x 38 10 le4k065 3.19 (1.45) 2.2 4 4 4 - - 9 10 x 38 12 le4k095 3.19 (1.45) or le4d09 (4) 4.32 (1.96) 2.2 4 4 4 5.5 - 9 10 x 38 12 le4d09 4.32 (1.96) 3 5.5 5.5 5.5 7.5 - 12 10 x 38 16 le4d12 4.32 (1.96) 4 7.5 9 9 10 - 18 10 x 38 20 le4d18 4.85 (2.20) 5.511111115 - 25 10 x 3825 le4d25 4.85 (2.20) 7.5 15 15 15 18.5 18.5 35 14 x 51 32 le4d35 11.4 (5.19) 11 18.5 22 22 22 30 40 14 x 51 40 le4d406 12.7 (5.77) 15 22 25 30 30 33 50 22 x 58 63 le4d506 14.2 (6.44) 18.5 30 37 37 37 37 65 22 x 58 80 le4d656 14.7 (6.67) 22 37 45 45 55 45 80 22 x 58 80 le4d806 (5) 15.6 (7.10) reversing starters 1.5 2.2 2.2 3 - - 6 10 x 38 10 le8k065 3.52 (1.60) 2.2 4 4 4 - - 9 10 x 38 12 le8k095 3.52 (1.60) or le8d09 (4) 7.82 (3.55) - - - - 5.5 - 9 10 x 38 12 le8d09 7.82 (3.55) 3 5.5 5.5 5.5 7.5 - 12 10 x 38 16 le8d12 7.82 (3.55) 4 7.5 9 9 10 - 18 10 x 38 20 le8d18 8.16 (3.70) 5.511111115 - 25 10 x 3825 le8d25 10.3 (4.67) 7.5 15 15 15 18.5 18.5 35 14 x 51 32 le8d35 12.8 (5.80) 11 18.5 22 22 22 30 40 14 x 51 40 le2d406 31.24 (14.17) 15 22 25 30 30 33 50 22 x 58 63 le2d506 32.40 (14.17) 18.5 30 37 37 37 37 65 22 x 58 80 le2d656 32.56 (14.77) 22 37 45 45 55 45 80 22 x 58 80 le2d806 35.30 (16.00) volts ac 50/60 hz 24 42 48 110 115 220 230 240 380 400 415 440 lek b7 d7 e7 f7 ? m7 p7 u7 q7 v7 n7 r7 led b7 d7 e7 f7 fe7 m7 p7 u7 q7 v7 n7 r7 for other voltages please consult your regional sales office. le4d12 le8d12
tesys? d-line contact ors and starters enclosed reversing starters with fused disconnect switch le2, le4 and le8 ? 2001-2004 schneider electric all rights reserved 162 01/04 international applications only enclosed reversing starters with fused disconnect switch le2d (int?l app. only) d.o.l. ac starters for motor control (1) 2.2 to 45 kw with isolator device (1) see previous page. (2) example: le4d09f7a04 other versions: combination of 2 accessories, please consult your regional sales office. description standard versions comprise:  for non-reversing starters: ? le4k and le4d09 to d656: ?le4d806: 1 green start button ?i?, 1 red stop/reset button ?o?. no pushbuttons on cover.  for reversing starters: ?le8k: 1 start button a , 1 start button e , 1 red stop/reset button. ? le8d09 to d35: 1 2-position spring return selector switch ?i?-?ii?, 1 red stop/reset button ?o?. ? le2d406 to d806: no pushbuttons on cover protection power circuit control circuit le4 and le8k 1 3-pole isolating device none le4 and le8d09 to d35 1 3-pole isolating device + 1 additional pole la8d254 le4 and le2d406 to d806 1 3-pole isolating device + 1 circuit-breaker gb2cb08 forms (installed by telemecanique) description for use on suffix to be added to starter catalog number (2) no push buttons on cover le4d09 through d656 le8d09 through d35 a04 1 green start button ?i? 1 green start button ?ii? 1 red stop/reset button ?o? le2d406 through d806 a11 1 blue reset button ?r? le4d09 through d806 le8k06 and k09 le2d406 through d806 a05 1 neutral terminal fitted as standard on le4d18 to d806, le8d18 to d35 and le4d406 to d806 starters ordered with 220 v (m7), 230 v (p7) or 240 v (u7) control circuit voltage. le4k06 and k09 le4d09 through d806 le8k06 and k09 le8d09 through d35 le2d406 through d806 a59 accessories (installed by the customer) description for use on catalog number weight lbs (kg) start pushbutton latching device for stay-put operation (start-stop) le4d406 through d656 la9d09907 0.13 (0.06) le4d12a04 le4d12a05
tesys? d-line contactors and starters wye-delta starters le3d (international applications only) 163 01/04 ? 2001-2004 schneider electric all rights reserved wye-delta starters le3d (international applications only) wye-delta starters for motor control from 4 to 75 kw, without off-load is olator (1) - references (1) overload protection by thermal overload relay, to be ordered separately. select appropriate overload relay for setting at 0. 58 the full load rated motor current. (2) standard control circuit voltages (variable deliver y time, please consult your regional sales office). (4) selection according to size and number of operating cycles (see ac-3 curves, page 20). (5) example: le3-d095f7a04. (6) other voltages: for le3-k, please consult your regional sales office. other versions: combination of 2 accessories, please consult your regional sales office. selection standard power ratings of squirrel cage motors mains voltage - delta connection (kw) catalog number, complete with control circuit voltage code (2) normal control circuit voltage code weight lbs (kg) 220 v 380 v 415v 440 v maximum operating rate in starts/hour : le3-k: 12 and le3-d: 30. maximu m starting time: 30 seconds. (4) 3 5.5 5.5 5.5 le3k065 f7 m7 q7 3.22 (1.46) 4 7.5 7.5 7.5 le3k095 f7 m7 q7 3.22 (1.46) or le3d09 f7 m7 q7 8.05 (3.65) 5.5111111 le3d12 f7 m7 q7 8.05 (3.65) 11 18.5 22 22 le3d18 f7 m7 q7 8.27 (3.75) 15 25 30 30 le3d32 f7 m7 q7 11.38 (5.16) 18.5 37 37 37 le3d405 f7 m7 q7 17.99 (8.16) 30 55 59 59 le3d505 f7 m7 q7 17.97 (8.15) 37 75 75 75 le3d805 f7 m7 q7 30.87 (14.00) specifications enclosure le3d09 through d80 metal enclosure, ip 559 control (2 push buttons mounted on enclosure cover) le3d09 through d18 1 green start button ?i? 1 red stop/reset button ?o? no push buttons on cover le3d32 through d80 - connections le3k06 and k09 pre-wired power and control circuit connections a timer la2-ds2 imposes a delay of 40 ms 15 ms on the delta contactor at the moment of changeover to ensure that the star con tactor has sufficient breaking time. forms (installed by telemecanique) description for use on suff ix to be added to starter catalog number (5) no push buttons on cover le3d09 through d18 a04 1 blue reset button ?r? le3d09 through d80 a05 1 green start button ?i? 1 red stop/reset button ?o? le3d32 through d80 a06 1 neutral terminal fitted as standard on starters ordered with 240 v (u7) control circuit voltage. le3k06 and k09 le3d09 through d80 a59 mechanical interlock fitted as standard on starters le3k and le3d09 to d35 le3d405 to d150 a64 control circuit voltage codes le3-k (6) control voltag e 50/60 hz 12 24 36 42 48 110 127 220/ 230 230 230- 240 380/ 400 400 400/ 415 440 500 660/ 690 code j7 b7 c7 d7 e7 f7 fc7 m7 p7 u7 q7 v7 n7 r7 s7 y7 le3-d (6) control voltag e 50/60 hz 24 42 48 110 220/230 230 240 380/400 400 415 440 code b7 d7 e7 f7 m7 p7 u7 q7 v7 n7 r7 le3d12
tesys? d-line contact ors and starters wye-delta starters with fused disconnect switch le3d (international applications only) ? 2001-2004 schneider electric all rights reserved 164 01/04 wye-delta starters with fused disconnect switch le3d (international applications only) note: wiring methods differ from typical north american practice. contains ul listed, csa certified, and ce marked components. assemblies are not ul listed or csa certified. coil selection forms (installed by telemecanique) standard power ratings of squirrel cage motors mains voltages - delta connection fuses to be installed by customer catalog number c p weight 220 v 380 v 415 v 440 v size type am kw kw kw kw a kg (lb.) maximum operating rate: 30 starts/hour. maximum starting time: 30 seconds. 4 7.5 7.5 7.5 10 x 38 20 le6d09 ?? 3.900 (8.598) 5.5 11 11 11 10 x 38 25 le6d12 ?? 3.900 (8.598) 11 18.5 22 22 14 x 51 40 le6d18 ?? 4.850 (10.692) 15 25 30 30 22 x 58 63 le6d326 ?? 7.650 (16.865) 18.5 37 37 37 22 x 58 80 le3d406 ?? 16.90 (37.256) 30 55 59 59 22 x 58 125 le3d506 ?? 17.00 (37.478) 37 75 75 75 0 160 le3d806 ?? 27.50 (60.626) specifications enclosure le3d09 to le3d80 metal enclosure, degree of protection ip 559 control (2 pushbuttons on enclosure cover) le3d09 and le3d12 1 green start button ?l? 1 red stop/reset button ?o? no pushbuttons on cover le3d18 to le3d80 ? isolator with external operator le3d09 and le3d12 1 3-pole isolator + 1 additional pole la8d254 le3d18 to le3d80 1 3-pole isolator and 1 circuit breaker gb2-cb08 connections le3d09 to le3d80 pre-wired power and control circuit connections a timer la2ds2 imposes a delay of 40 ms 15 ms on the delta contactor at the moment of changeover to ensure that the star contactor has suff icient breaking time. c overload protection by means of bimetallic overload relay, to be ordered separately. select appropriate overload relay for setting at 0.58 of the full-load rated motor current. p complete catalog number with appropriate coil selection code below. 50/60 hz 24 42 48 110 220/230 230 240 380/400 400 415 440 voltage code b7 d7 e7 f7 m7 p7 u7 q7 v7 n7 r7 description for use on suffix to be added to starter catalog number k no pushbuttons on cover le3d09 to le3d12 a04 1 blue reset button ?r? le3d09 to le3d80 a05 1 green start button ?i? 1 red stop/reset button ?o? le3d18 to le3d80 a06 1 neutral terminal fitted as standard on starters ordered with 240 v (u7) control supply le3d09 to le3d80 a59 mechanical interlock fitted as standard on starters le6d09 to d18 le3d326 to d80 a64 k for example: le3d096f7a04 . le6d12 international applications only le6d12a04 le6d12a05
tesys? d-line contactors and starters spare parts and accessories (international applications only) 165 01/04 ? 2001-2004 schneider electric all rights reserved spare parts and accessories (international applications only) (1) remember to order mounting kit lad9091 or lad91810 , depending on the size. (2) remember to order mounting kit lad9092 . (3) sold in lots of 10. (4) le1, le2, le3, le4, le6 or le8. operating heads for start and stop/reset pushbuttons description for use on catalog number weight ? kg (lb.) flush green ?i? (1) le1d09 to d35 zb5aa331 0.018 (0.040) projecting red ?o? (1) le1d09 to d35 zb5al432 0.019 (0.042) mounting kit for head zb5al432 le1d09 and d12 lad9091 0.002 (0.004) le1d18 to d35 lad91810 0.003 (0.006) operating heads for reset pushbuttons flush blue ?r? (2) le1d09 to d35 zb5aa0 0.022 (0.048) zba639 (3) 0.001 (0.002) mounting kit for head zb5aa0 + zba639 le1d09 and d12 lad9092 0.002 (0.004) le1 or le2d18 to d35 lad91810 0.003 (0.006) le3, le6, le4 or le8d09 to d35 lad9t4 0.004 (0.008) operating heads for selector switches description for use on catalog number weight ? kg (lb.) 3 position stay put le1d09 to d35 zb5ad3 0.024 (0.053) 2 position stay put le1d09 to d35 zb5ad2 0.024 (0.053) 3 position spring return to center le1d09 to d35 zb5ad5 0.024 (0.053) contact blocks 1 n.o. spring return le1d09 to d35 zenl1111 0.010 (0.022) 1 n.c. spring return le1d09 to d35 zenl1121 0.010 (0.022) contact block support le1d09 and d12 lad90909 0.008 (0.017) le ? d18 to d35 (4) lad91809 0.014 (0.031) zb5aa331 zb5al432 lad9091 zb5ad zenl1111 lad91809
tesys? d-line contact ors and starters spare parts and accessories (international applications only) ? 2001-2004 schneider electric all rights reserved 166 01/04 empty enclosures for d.o.l. st arters without isolator device for use with push button operating head(s) or blanking plug(s) mounted on the cover catalog number weight kg (lb.) le1d09, d12 without de1ds1a04 0.300 (0.66) 1 flush blue head ?r? de1ds1a05 0.300 (0.66) 1 flush green head ?i? 1 projecting red head ?o? de1ds1 0.300 (0.66) 1 flush blue head ?r? 1 switch de1ds1a13 0.300 (0.66) le1d18 to d35 without de1ds2a04 0.500 (1.10) 1 flush blue head ?r? de1ds2a05 0.500 (1.10) 1 flush green head ?i? 1 projecting red head ?o? de1ds2 0.500 (1.10) 1 flush blue head ?r? 1 switch de1ds2a13 0.500 (1.10) de1ds1a13 de1ds1a04 de1ds1a05 de1ds1
tesys? d-line contactors and starters led dimensions (international applications only) 167 01/04 ? 2001-2004 schneider electric all rights reserved led dimensions (international applications only) enclosed d-line starters with out fused disconnect switch le1d09 and d12 le1d18 to d35 le2d09 to d35 le1d405 to d655 c1 c1 c1 le1d le2d standard version 5.05 (128.5) standard version 6.0 (153.5) 6.3 (160) standard version 6.33 (161) version a04 4.7 (120) version a04 5.7 (145) 5.7 (145) version a04 5.9 (150) version a05 5.05 (128.5) version a05 6.0 (153.5) 6.0 (153.5) version a05 6.33 (161) version a09 5.31 (135) version a09 6.3 (160) ? version a13 5.31 (135) version a13 6.3 (160) ? version a35 5.31 (135) version a35 6.3 (160) ? le2d095, le2d125, le2d185, le2d255 le1d805 and d955 le2d405 to d655 le2d805 and d955 c1 c1 le1d le2d standard version 6.9 (176) 6.9 (176) standard version 7.6 (194) version a04 6.5 (165) 6.5 (165) version a04 7.48 (190) version a05 6.9 (176) ? version a05 7.6 (194) version a11 ? 6.9 (176) knock-outs or blanking plugs for cable glands type of enclosure at top at bottom pg iso pg iso le1d09 and d12 2 x 13 or 2 x 16 2 x 20 i 2 x 13 or 2 x 16 2 x 20 i le1d18 to d35 and le2d09 to d35 2 x 16 or 2 x 21 2 x 20 i or 2 x 25 i 2 x 16 or 2 x 21 2 x 20 i or 2 x 25 i le2d405 1 x 13 and 1 x 21 1 x 20 i and 1 x 25 i 1 x 13 and 2 x 21 1 x 20 i and 2 x 25 i le1d405 to d655 and le2d505 and d655 1 x 13 and 1 x 29 1 x 20 i and 1 x 32 i 1 x 13 and 2 x 29 1 x 20 i and 2 x 32 i le1 or le2d805 and d955 1 x 13 and 1 x 36 1 x 20 i and 1 x 40 i 1 x 13 and 2 x 36 1 x 20 i and 2 x 40 i le2k 2 x 13 and 2 x 16 4 x 20 i 2 x 13 and 2 x 16 4 x 20 i (millimeters x 0.0394 = inches) c1 6.5 166 5.9 150 == = 3.4 88 = 0.08 x 0.21 c1 7.2 183 == 3.9 101 7.9 201 0.08 x 0.20 c1 12.2 312 = 7.12 181 = 4.13 105 7.67 195 == 0.15 x 0.3 5.74 146 4.72 120 3.3 84 6.88 175 5.9 150 6.49 165 0.74 (19) 0.15 x 0.20 dual dimensions: inches mm c1 12.0 307 = 10.1 257 = 4.49 165 6.49 165 == 0.15 x 0.3 11.29 287 c1 = 14.61 367 = 8.85 225 7.67 195 == 0.15 x 0.3
tesys? d-line contact ors and starters led dimensions (international applications only) ? 2001-2004 schneider electric all rights reserved 168 01/04 enclosed d-line starters wi th fused disconnect switch le4k06 and k09 le8k06 and k09 le4d09 to d35 le8d09 to d35 c1 c1 le4k le8k le4d le8d standard version 5.74 (146) 5.74 (146) standard version 6.90 (175.5) 7.16 (182) version a05 ? 5.47 (139) version a04 6.57 (167) 6.57 (167) version a05 6.90 (175.5) 6.90 (175.5) (1) for le8 only. le4d406 to d656 c1 standard version 7.91 (201) version a04 7.48 (190) version a05 7.91 (201) le2d406 to d806 le4d806 le2 a d406, d506, d656 11.8 (300) d806 15.7 (400) le4 a d806 15.7 (400) c1? le2d le4d standard version 8.58 (218) 8.58 (218) version a05 8.58 (218) 8.58 (218) version a11 ? 8.58 (218) (1) + 14 mm with blankink plugs knock-outs or blanking plugs for cable glands type of enclosure at top at bottom pg iso pg iso le4 and le8d09 to d35 2 x 13 or 2 x 16 or 2 x 21 or 2 x 29 2 x 20 i or 2 x 25 i or 2 x 32 i or 2 x 40 i 2 x 13 or 2 x 16 or 2 x 21 or 2 x 29 2 x 20 i or 2 x 25 i or 2 x 32 i or 2 x 40 i le2d09 to d35 1 x 16 or 2 x 21 2 x 20 i or 2 x 25 i 2 x 16 or 2 x 21 2 x 20 i or 2 x 25 i le2d406 and le4d406 1 x 13 and 1 x 21 1 x 20 i and 1 x 25 i 1 x 13 and 2 x 21 1 x 20 i and 2 x 25 i le1d506 to d656 and le4d506 and d656 1 x 13 and 1 x 29 1 x 20 i and 1 x 32 i 1 x 13 and 2 x 29 1 x 20 i and 2 x 32 i le2d806 and le4d806 1 x 13 and 1 x 36 1 x 20 i and 1 x 40 i 1 x 13 and 2 x 36 1 x 20 i and 2 x 40 i le4k, le8k 2 x 13 and 2 x 16 4 x 20 i 2 x 13 and 2 x 16 4 x 20 i (millimeters x 0.0394 = inches) c1 0.78 20 3.3 84 6.88 175 5.9 150 6.49 165 (1) 4.72 120 0.74 19 1.2 31 1.15 x 0.21 c1 13.7 348 12.9 330 == = 7.32 186 1.22 31 = 0.08 x 6.21 11.3 287 c1 = 14.4 367 = 14.4 31 8.85 225 7.67 195 = = 0.15 x 0.30 dual dimensions: inches mm 15.7 400 (1) 7.95 202 c1 = = 2.9 a-75 1.9 a-50 a 2.26 a+57.5 13.7 350 13.48 342.5 12.8 325 = = 4xm8x25 1.2 31
tesys? d-line contactors and starters lek dimensions (international applications only) 169 01/04 ? 2001-2004 schneider electric all rights reserved lek dimensions (international applications only) enclosed k-line starters with out fused disconnect switch le3k065, k095 le3d09 to d35 c1 standard version 6.90 (175.5) version a04 6.57 (167) version a05 6.90 (175.5) le3d405 to d505 dimensions shown in millimeters (millimeters x 0.0394 = inches) c1 standard version 7.48 (190) version a05 7.63 (194) version a06 7.63 (194) le3d805 to d150 le3 ab d805 15.7 (400) 15.7 (400) d1155 19.6 (500) 23.6 (600) d1505 19.6 (500) 23.6 9600) c1 le3d805 le3d115, d150 standard version 7.95 (202) 9.92 (252) version a05 8.58 (218) ? version a06 8.58 (218) 10.55 (268) (1) + 14 mm with blankink plugs knock-outs or blanking plugs for cable glands type of enclosure at top at bottom pg iso pg iso le3d09 to d35 2 x 13 or 2 x 16 or 2 x 21 or 2 x 29 2 x 20 i or 2 x 25 i or 2 x 32 i or 2 x 40 i 2 x 13 or 2 x 16 or 2 x 21 or 2 x 29 2 x 20 i or 2 x 25 i or 2 x 32 i or 2 x 40 i le3d405 1 x 29 1 x 32 i 1 x 29, 2 x 13 and 2 x 21 1 x 32 i, 2 x 20 i and 2 x 25 i le3d505 1 x 36 1 x 40 i 1 x 36, 2 x 13 and 2 x 29 1 x 40 i, 2 x 20 i and 2 x 32 i le3d805 1 x 36 1 x 40 i 2 x 13 and 3 x 36 2 x 20 i and 3 x 40 i le3k 2 x 13 and 2 x 16 4 x 20 i 2 x 13 and 2 x 16 4 x 20 i (millimeters x 0.0394 = inches) 3.3 84 6.88 175 5.90 150 5.74 146 4.72 120 6.49 165 0.74 (19) 0.15 x 0.20 c1 13.7 348 12.9 330 == = 7.32 186 = 0.07 x 0.21 11.29 287 c1 = 14.4 367 = 8.85 225 7.67 195 == 0.15 x 0.30 dual dimensions: inches mm b (1) c1 c1 + 0.61 15.5 = = a - 2.95 75 a - 1.96 50 a a + 2.26 57.5 b - 1.96 50 b + 2.26 57.5 b - 2.95 75 = = 0.15 x 0.31 x 0.98
tesys? d-line contact ors and starters lg1k and lg1d dimensions (international applications only) ? 2001-2004 schneider electric all rights reserved 170 01/04 starters without isolator le6d09 to d18 le3d326 c1 standard version 6.90 (175.5) version a04 6.57 (167) version a05 6.90 (175.5) le3d406 to d806 le3 abc1 d406, d506 15.7 (400) 19.6 (500) 8.58 (218) d806 19.6 (500) 27.5 (700) 10.6 (269) (1) + 14 mm with blankink plugs knock-outs or blanking plugs for cable glands type of enclosure at top at bottom pg iso pg iso le6d09 to d18 2 x 13 or 2 x 16 or 2 x 21 or 2 x 29 2 x 20 i or 2 x 25 i or 2 x 32 i or 2 x 40 i 2 x 13 or 2 x 16 or 2 x 21 or 2 x 29 2 x 20 i or 2 x 25 i or 2 x 32 i or 2 x 40 i le3d326 1 x 21 1 x 32 i 2 x 13, 2 x 16 and 1 x 21 2 x 20 i, 2 x 25 i and 1 x 32 i le3d406 1 x 29 1 x 32 i 2 x 13, 2 x 21 and 1 x 29 2 x 20 i, 2 x 25 i and 1 x 32 i le3d506 1 x 36 1 x 40 i 2 x 13, 2 x 29 and 1 x 36 1 x 40 i, 2 x 20 i and 2 x 32 i le3d806 1 x 36 1 x 40 i 2 x 13 and 3 x 36 2 x 20 i and 3 x 40 i (millimeters x 0.0394 = inches) c1 13.7 348 12.9 330 = = = 7.32 186 1.2 31 = 0.07 x 0.21 7.48 190 14.4 367 8.85 225 = = = 11.29 287 = 1.2 31 7.67 195 0.15 x 0.30 b (1) c1 = = a-2.9 75 a-1.96 50 a a+57.5 2.26 b-1.96 50 b+2.26 57.5 b-2.9 75 = = 4xm8x25 1.2 31 0.15 x 0.31 x 0.98 dual dimensions: inches mm
tesys? d-line contactors and starters le1k and le1d wiring diagrams (international applications only) 171 01/04 ? 2001-2004 schneider electric all rights reserved le1k and le1d wiring diagrams (international applications only) le1d09 to d955 le1d09 to d955 form a04 or a05 le2k06, k09 le2k06, k09 form a05 le2d09 to d955 le2d09 to d35 le2d405 to d955 le2d09 to d955 with forms a04 or a05 connections ab 220 v, 230 v, 240 v le2k, le1 and le2d09 and d12 l3 neutral le1 and le2d18 to d955 l3 neutral terminal 380 v, 400 v, 415 v, 440 v all products l3 l1 other voltages le1 and le2d09 to d35 terminal 1 terminal 2 le2k, le1 and le2d405 and d955 direct connection direct connection l1 l2 ? km1 u v w l3 b a a1 a2 ? km1 ? km1 o i 13 14 21 22 a o l ? km1 b a1 a2 ? km1 ? km1 ? km2 l1 l2 l3 u v w ? km2 a b ? km1 ? km2 ? km1 ? km2 ? km1 a1 a2 a1 a2 o b ? km2 ? km1 ? km2 ? km1 a1 a2 a1 a2 a r ? km1 ? km2 l1 l2 l3 u v w a1 a2 ? km1 ? km2 ? km2 a a1 a2 ? km2 ? km1 b ? km1 ? s1 ii i ? km2 a1 a2 ? km1 21 22 ? km2 a o a1 a2 ? km2 ? km1 b r l l l ? km1
tesys? d-line contact ors and starters le2k and le2d wiring diagrams (international applications only) ? 2001-2004 schneider electric all rights reserved 172 01/04 le2k and le2d wiring diagrams (international applications only) le6d09 to d18 le6d09 to d18 recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). le3d326 t0 d806 le3d326 to d806 recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). connections ab 220 v, 230 v, 240 v le6d09 and d12 l3 neutral le6d18 to le3d806 l3 neutral terminal 380 v, 400 v, 415 v, 440 v all products l3 l1 other voltages le6d09 to d18 terminal 1 terminal 2 le3d326 to d806 direct connection direct connection ? km2 1 2 3 4 5 6 ? km3 1 2 3 4 5 6 ? km1 1 2 3 4 5 6 u1 v1 w1 u2 v2 w2 1 3 5 2 4 6 ? q1 1/l1 2 3/l2 4 5/l3 6 u1 v1 w1 u2 v2 w2 2 4 6 a1 a2 ? km1 ? km3 ? km2 ? km1 l ? km2 a1 a2 ? km3 ? km1 a1 a2 ? km2 ? km2 b o a q1 q1 ? km2 1 2 3 4 5 6 ? km3 1 2 3 4 5 6 ? km1 1 2 3 4 5 6 u1 v1 w1 u2 v2 w2 1 3 5 2 4 6 ? q1 1/l1 2 3/l2 4 5/l3 6 u1 v1 w1 u2 v2 w2 2 4 6 a1 a2 ? km1 13 14 ? km3 ? km2 ? km1 l ? km2 a1 a2 ? km3 ? km1 a1 a2 ? km2 ? km2 b a q1 ? f1 21 22 ? s1
tesys? d-line contactors and starters le4k, le4d, le8k, and le2d dimensions (international applications only) 173 01/04 ? 2001-2004 schneider electric all rights reserved le3k065 and k095 le3k065 and k095 le3d09 to d805 le3d09 to d35 le3d405 to d805 note: in accordance with current installation regulations, short-circuit protection must be provided by fused or a circuit-breaker. le3d115 and d150 le3d115 and d150 connections ab 220 v, 230 v, 240 v ld09 and d12 l3 neutral le3d18 to d150 l3 neutral terminal 380 v, 400 v, 415 v, 440 v all products l3 l1 other voltages le3d09 to d35 terminal 1 terminal 2 le3k and le3d405 to d150 direct connection direct connection ? km2 ? km3 ? km1 l1 l2 l3 u1 v1 w1 u2 v2 w2 u1 v1 w1 u2 v2 w2 recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). a o ? km3 ? km2 ? km1 t t ? km1 i y l a1 a2 a1 a2 a1 a2 a1 a2 ? km1 ? km3 ? km2 b u1 v1 w1 u2 v2 w2 e km2 e km3 e km1 u1 v1 w1 u2 v2 w2 l1 l2 l3 recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). a1 a2 ? km1 ? km3 ? km2 ? km1 ? km2 a1 a2 ? km3 ? km1 a1 a2 ? km2 ? km2 b a o i y l a1 a2 ? km1 17 18 ? km3 ? km2 ? km1 ? km2 a1 a2 ? km3 ? km1 a1 a2 ? km2 ? km2 b a i y l u1 v1 w1 u2 v2 w2 e km2 e km3 e km1 u1 v1 w1 u2 v2 w2 l1 l2 l3 recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). 17 18 l a1 a2 ? km1 ? km3 ? km2 ? km1 ? km2 a1 a2 ? ka1 a1 a2 ? km2 ? km1 ? f2 ? km2 ? km1 a1 a2 ? km3 ? ka1 y l a b
tesys? d-line contact ors and starters lg1k, lg1d, lg7k, lg7d, and lg8k dimensions (international applications only) ? 2001-2004 schneider electric all rights reserved 174 01/04 lg1k, lg1d, lg7k, lg7d, and lg8k dimensions (international applications only) le4k06, k09 le4d09 to d806 le4k06, k09 le4d09 to d35 le4d406 to d656 le4d806 le4d09 to d656 with form a04 or a05 le8k06, k09 le8k06, k09 form a05 le8d09 to le2d806 le8d09 to d35 le2d406 to d806 connections ab 220 v, 230 v, 240 v le4 and le8k, le4 and le8d09 and d12 l3 neutral le4d18 to d806, le8d18 to d35 and le2d406 to d806 l3 neutral terminal 380 v, 400 v, 415 v, 440 v all products l3 l1 other voltages le4 and le8d09 to d35 terminal 1 terminal 2 le4 and le2d406 and d806 direct connection direct connection ? q1 ? km1 l1 l2 l3 u w v ? km1 o i ? km1 a1 a2 a b b a a1 a2 ? km1 ? km1 18 17 q1 q1 o i o l a1 a2 ? km1 ? km1 q1 ? f1 b a 13 14 21 22 o l ? km1 a2 a1 ? km1 q1 ? f1 b a ? q1 ? km1 ? km2 l1 l2 l3 u v w ? km2 ? km1 ? km2 ? km2 ? km1 a1 a2 ? q1 ? km1 a1 a2 a b o ? km2 ? km1 ? km2 ? km1 a1 a2 a1 a2 r a b ? q1 ? km1 ? km2 l1 l2 l3 u v w a1 a2 ? km1 ? km2 ? km2 a1 a2 ? km2 ? km1 ? km1 q1 q1 a b ? s1 ii i o a1 a2 ? km1 21 22 ? km2 ? km2 o a1 a2 ? km2 ? km1 13 14 l ? km1 13 14 l l q1 ? f1 a b
tesys? d-line contactors and starters cross-reference table 175 01/04 ? 2001-2004 schneider electric all rights reserved cross-reference table (1) coil voltages: codes to be added to the end of the new catalog numbers (2) coil voltages: codes to be added to the end of the new catalog numbers 3-pole ac contactors(1) connection for cables with or without cable end for ring terminal type for slip on connectors old catalog no. new catalog no. o ld catalog no. new catalog no. o ld catalog no. new catalog no. lc1d0900 lc1d09 lc1d09006 lc1d096 lc1d09009 lc1d099 lc1d0910 lc1d09 lc1d09106 lc1d096 lc1d09109 lc1d099 lc1d0901 lc1d09 lc1d09016 lc1d096 lc1d09019 lc1d099 lc1d1200 lc1d12 lc1d12006 lc1d126 lc1d12009 lc1d129 lc1d1210 lc1d12 lc1d12106 lc1d126 lc1d12109 lc1d129 lc1d1201 lc1d12 lc1d12016 lc1d126 lc1d12019 lc1d129 lc1d1800 lc1d18 lc1d18006 lc1d186 lc1d1810 lc1d18 lc1d18106 lc1d186 lc1d1801 lc1d18 lc1d18016 lc1d186 lc1d2500 lc1d25 lc1d25006 lc1d256 lc1d2510 lc1d25 lc1d25106 lc1d256 lc1d2501 lc1d25 lc1d25016 lc1d256 lc1d3200 lc1d32 lc1d32006 lc1d326 lc1d3210 lc1d32 lc1d32106 lc1d326 lc1d3201 lc1d32 lc1d32016 lc1d326 lc1d3810 lc1d38 lc1d38106 lc1d386 lc1d3801 lc1d38 lc1d38016 lc1d386 lc1d4011 lc1d40 lc1d40116 lc1d406 lc1d5011 lc1d50 lc1d50116 lc1d506 lc1d6511 lc1d65 lc1d65116 lc1d656 lc1d8011 lc1d80 lc1d80116 lc1d806 lc1d9511 lc1d95 lc1d95116 lc1d956 lc1d11500 lc1d115 lc1d115006 lc1d1156 lc1d15000 lc1d150 lc1d150006 lc1d1506 4-pole ac contactors (1) lc1d12004 lc1dt25 lc1d120046 lc1dt256 lc1d12008 lc1d128 lc1d120086 lc1d1286 lc1d25004 lc1dt40 lc1d250046 lc1dt406 lc1d25008 lc1d258 lc1d250086 lc1d2586 volts - 50/60 hz 24 48 220 230 380 400 voltage code b7 e7 m7 p7 q7 v7 3-pole dc contactors (2) lp1d0910 lc1d09 lp1d09106 lc1d096 lp1d09109 lc1d099 lp1d0901 lc1d09 lp1d09016 lc1d096 lp1d09019 lc1d099 lp1d1210 lc1d12 lp1d12106 lc1d126 lp1d12109 lc1d129 lp1d1201 lc1d12 lp1d12016 lc1d126 lp1d12019 lc1d129 lp1d1810 lc1d18 lp1d18106 lc1d186 lp1d1801 lc1d18 lp1d18016 lc1d186 lp1d2510 lc1d25 lp1d25106 lc1d256 lp1d2501 lc1d25 lp1d25016 lc1d256 lp1d3210 lc1d32 lp1d32106 lc1d326 lp1d3201 lc1d32 lp1d32016 lc1d326 lp1d4011 lc1d40 lp1d40116 lc1d406 lp1d5011 lc1d50 lp1d50116 lc1d506 lp1d6511 lc1d65 lp1d65116 lc1d656 lp1d8011 lc1d80 lp1d80116 lc1d806 lp1d11500 lc1d115 lc1d115006 lc1d1156 lp1d15000 lc1d150 lc1d150006 lc1d1506 4-pole dc contactors (2) lp1d12004 lc1dt25 lc1d120046 lc1dt256 lp1d12008 lc1d128 lc1d120086 lc1d1286 lp1d25004 lc1dt40 lc1d250046 lc1dt406 lp1d25008 lc1d258 lc1d250086 lc1d2586 volts dc 24 48 72 voltage code bd ed sd
tesys? d-line contact ors and starters cross-reference table ? 2001-2004 schneider electric all rights reserved 176 01/04 (1) coil voltages: codes to be added to the end of the new catalog numbers 3-pole contactors, low consumption (1) connection for cables with or without cable end for lugs or bars for faston connectors old catalog no. new catalog no. old catalog no. n ew catalog no. old catalog no. new catalog no. lp4d0910 lc1d09 lp4d0901 lc1d09 lp4d1210 lc1d12 lp4d1201 lc1d12 lp4d1810 lc1d18 lp4d1801 lc1d18 lp4d2500 lc1d25 3-pole reversing contactors, low consumption (1) lp5d0910 lc2d09 lp5d1210 lc2d12 lp5d1810 lc2d18 lp5d2500 lc2d25 low consumption volts 24 48 72 code bl el sl 3-pole reversing contactors, ac lc2d0901 lc2d09 lc2d09016 lc2d096 lc2d09019 lc2d099 lc2d1201 lc2d12 lc2d12016 lc2d126 lc2d12019 lc2d129 lc2d1801 lc2d18 lc2d18016 lc2d186 lc2d2501 lc2d25 lc2d25016 lc2d256 lc2d3201 lc2d32 lc2d32016 lc2d326 lc2d3801 lc2d38 lc2d38016 lc2d386 lc2d4011 lc2d40 lc2d115006 lc2d1156 lc2d5011 lc2d50 lc2d150006 lc2d1506 lc2d6511 lc2d65 lc2d8011 lc2d80 lc2d9511 lc2d95 lc2d11500 lc2d115 lc2d15000 lc2d150 4-pole changeover contactors, ac lc2d12004 lc2dt25 lc2d120046 lc2dt256 lc2d25004 lc2dt40 lc2d250046 lc2dt406 3-pole reversing contactors, dc lp2d0901 lc2d09 lp2d09016 lc2d0906 lp2d09109 lc2d099 lp2d1201 lc2d12 lp2d12016 lc2d126 lp2d12019 lc2d129 lp2d1801 lc2d18 lp2d18016 lc2d186 lp2d2501 lc2d25 lp2d25016 lc2d256 lp2d3201 lc2d32 lp2d32016 lc2d326 4-pole changeover contactors, dc lp2d12004 lc2dt25 lp2d120046 lc2dt256 lp2d25004 lc2dt40 lp2d250046 lc2dt406 contact blocks la1dn10 ladn10 la1dn11m la1dn11g la2dt0 ladt0 la1dn01 ladn01 la1dn11p ladn11p la2dt2 ladt2 la1dn11 ladn11 la1dn11g ladn11g la2dt4 ladt4 la1dn20 ladn20 la1dn22m ladn22g la2ds2 lads2 la1dn02 ladn02 la1dn13m ladn22g la3dr0 ladr0 la8dn11 lad8n11 la1dn31m ladn31g la3dr2 ladr2 la8dn20 lad8n20 la1dn22p ladn22p la3dr4 ladr4 la1dn22 ladn22 la1dn13p ladn31p la1dn13 ladn13 la1dn31p ladn31p la1dn40 ladn40 la1dn22g ladn22g la1dn04 ladn04 ln1dn11 ladn11 la1dn31 ladn31 la1dc22 ladc22
tesys? d-line contactors and starters cross-reference table 177 01/04 ? 2001-2004 schneider electric all rights reserved thermal overload relays for use with balanced loads for use with unbalanced (single phase) loads for use on 1000v supplies old catalog no. new catalog no. old catalog no. n ew catalog no. old catalog no. new catalog no. lr2d1301 lrd01 lr3d1301 lr3d01 lr2d3301a66 lrd3301a66 lr2d1302 lrd02 lr3d1302 lr3d02 lr2d3302a66 lrd3302a66 lr2d1303 lrd03 lr3d1303 lr3d03 lr2d3303a66 lrd3303a66 lr2d1304 lrd04 lr3d1304 lr3d04 lr2d3304a66 lrd3304a66 lr2d1305 lrd05 lr3d1305 lr3d05 lr2d3305a66 lrd3305a66 lr2d1306 lrd06 lr3d1306 lr3d06 lr2d3306a66 lrd3306a66 lr2d13x6 lrd06 lr3d13x6 lr3d06 lr2d33x6a66 lrd33x6a66 lr2d1307 lrd07 lr3d1307 lr3d07 lr2d3307a66 lrd3307a66 lr2d1308 lrd08 lr3d1308 lr3d08 lr2d3308a66 lrd3308a66 lr2d1310 lrd10 lr3d1310 lr3d10 lr2d3310a66 lrd3310a66 lr2d1312 lrd12 lr3d1312 lr3d12 lr2d3312a66 lrd3312a66 lr2d1314 lrd14 lr3d1314 lr3d14 lr2d3314a66 lrd3314a66 lr2d1316 lrd16 lr3d1316 lr3d16 lr2d3316a66 lrd3316a66 lr2d1321 lrd21 lr3d1321 lr3d21 lr2d3321a66 lrd3321a66 lr2d1322 lrd22 lr3d1322 lr3d22 lr2d3322a66 lrd3322a66 lr2d2353 lrd32 lr3d2353 lr3d32 lr2d2355 lrd35 lr3d2355 lr3d35 lr2d1508 lrd1508 lr2d1510 lrd1510 lr2d1512 lrd1512 lr2d1514 lrd1514 lr2d1516 lrd1516 lr2d1521 lrd1521 lr2d1522 lrd1522 lr2d2553 lrd1530 (1) or lrd1532 (1) lr2d3322 lrd3322 lr3d3322 lr3d3322 lr2d3353 lrd3353 lr3d3353 lr3d3353 lr2d3355 lrd3355 lr3d3355 lr3d3355 lr2d3357 lrd3357 lr3d3357 lr3d3357 lr2d3359 lrd3359 lr3d3359 lr3d3359 lr2d3361 lrd3361 lr3d3361 lr3d3361 lr2d3363 lrd3363 lr3d3363 lr3d3363 lr2d3365 lrd3365 lr3d3365 lr3d3365 lr2d4365 lrd4365 lr2d4367 lrd4367 lr2d4369 lrd4369 (1) depends on actual full load current.
tesys? d-line contact ors and starters ? 2001-2004 schneider electric all rights reserved 178 01/04
catalog 04 tesys ? f-line contactors, overload relays, and accessories file 8502 contents description page general information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 contactors characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 mechanical interlocks and power connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 auxiliary contacts and timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 accessories, and spare parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 f-line voltage code table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 replacement coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 dimensions and mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 solid state overload relays characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 dimensions and mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 wiring diagrams and special functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 cr1f/cr1b magnetic latching contactors characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 accessories ? selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 mechanical interlocks and power connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 coils and spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 dimensions and mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239 schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245 f-line
tesys? f-line contact ors and starters ? 2001-2004 schneider electric all rights reserved 180 01/04
tesys? f-line contactors and starters general information 181 01/04 ? 2001-2004 schneider electric all rights reserved general information the f-line contactors and overload relays offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps , compressors and overhead cranes. they offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry. contactor ratings f-line contactors and overload relays are available in the usa market for inductive motor applications up to 800 full load amps and resistive loads up to 1000 amps. they offer motor control and overload protection for motors rated up to 800 horsepower at 480 vac or 900 horsepower at 600 vac.  2 pole, 3 pole and 4 pole contactors and magnetic latching contactors  ac or dc operating coils  includes ul listing, csa certification and ce mark  both north american and international terminal markings  replacement parts available ? contact kits ? arc chambers ? operating coils  easily installed accessories ? auxiliary contact blocks with serrated wiping action ? front mount dust tight auxiliary contact blocks ? pneumatic time delay blocks  solid state overload relays class 10 or class 20 overload relays are available from 30 to 630 amperes. they are ambient compensated and include single phase sensitivity fo r phase unbalance and phase loss protection. they also include the following features: isolated n.c. trip contact, n.o. alarm contact, manual reset button, rotary dial for adjustable current settings with tamper resistant window, test trip button, momentary stop button and trip indicator.
tesys? f-line contact ors and starters characteristics ? 2001-2004 schneider electric all rights reserved 182 01/04 characteristics contactors type lc1f (115 to 800a) control circuit: ac or dc supply type lc1f115 lc1f150 lc1f185 lc1f225 lc1f265 environment rated insulation voltage (vi) conforming to iec 60947-4-1/iec 60947-4 v 1000 1000 1000 1000 1000 conforming to vde 0110 gr c v 1500 1500 1500 1500 1500 rated impulse withstand voltage (vimp) test with coil not connected to the power circuit kv88888 conforming to standards meets the essential requirements of the lv & emc directives iec 60947-4, nfc 63-110, vde 0660, bs 5424, jem 1038 approvals e164862 nldx lr 43364 3211 04 ase, csa, ul, bv, gl, lros, ussr, norsk veritas, rina degree of protection conforming to iec 60529 ip 20 front face with shrouds la9f conforming to vde 0106 protection against direct finger contact with shrouds la9f protective treatment standard version ?th? ambient air temperature around the device storage - 60 to + 80 c (- 76 to +176 f) operation - 5 to + 55 c (23 to + 131 f) for operation at 80 to 110% of nominal control voltage permissible at vc f - 40 to + 70 c (- 40 to + 158 f) for operation at nominal control voltage maximum operating altitude without derating 3000 m (9800 ft.) operating positions without derating 30 possible, in relation to normal vertical mounting plane shock resistance c 1/2 sine wave = 11 ms contactor open 9 gn 9 gn 7 gn 7 gn 6 gn contactor closed 13 gn 13 gn 15 gn 15 gn 15 gn vibration resistance c 5 to 300 hz contactor open 2 gn 2 gn 2 gn 2 gn 2 gn contactor closed 6 gn 6 gn 5 gn 5 gn 5 gn pole characteristics q number of poles 3 or 4 3 or 4 3 or 4 3 or 4 3 or 4 rated operational current (ie) (ve 440 v) in ac-3, q 55 c (131 f) a 115 150 185 225 265 in ac-1, q 40 c (104 f) a 200 250 275 315 350 rated operational voltage (ve) up to v 1000 1000 1000 1000 1000 frequency limits of the operational current p hz 16 2/3 to 200 16 2/3 to 200 16 2/3 to 200 16 2/3 to 200 16 2/3 to 200 conventional rated thermal current 40 c (104 f) a 200 250 275 315 350 rated maki ng capacity i rms to iec 60947-4-1 a 1400 1700 2100 2460 2940 rated breaking capacity i rms conforming to iec 60947-4-1 up to 440 v a 1300 1500 1800 2050 2450 500 v a 1100 1200 1600 1850 2200 660 to 690 v a 900 1100 1200 1350 1700 1000 v a 400 450 600 780 800 permissible short time rating from cold state, no current flowing for preceding 60 minutes 40 c (104 f) for 1 s a 1100 1200 1500 1800 2200 for 5 s a 1100 1200 1500 1800 2200 for 10 s a 1100 1200 1500 1800 2200 for 30 s a 640 700 920 1000 1230 for 1 min a 520 600 740 850 950 for 3 min a 400 450 500 560 620 for 10 min a 320 350 400 440 480 short-circuit protection by circuit breaker select in accordance with nec and local codes by fuses max 400% of motor fla average impeda nce per pole at ith and 50 hz m ? 0.40 0.40 0.36 0.36 0.32 power dissipation per pole for the above operational currents ac-3 w69121822 ac-1 w182526 3539 mechanical durability at nominal voltage millions of operations 10 10 10 10 10 maximum operating rate 55c (131f) ops/hr 2400 2400 2400 2400 2400 cabling cable size (min-max) awg #14 to 2/0 #6 to 3/0 #6 to 3/0 ? #6 to 300mcm lug dz2ff dz2fg dz2fg ? dz2fh tightening torque using dz2f ?? lug bolt lug to contactor lb.-in 89 160 160 ? 310 wire pressure screw lb.-in 120 200 200 ? 275 f in these conditions, for ratings f115 to f225, it is recommended to use lx9f coils. c in the least favorable direction, without change of contact state (coil at vc). q paralleling of poles must be carried out only in accordance with the fuse manufacturer's recommendations. p sine wave without interference, above these values, pl ease consult your local square d field sales office.
tesys? f-line contactors and starters characteristics 183 01/04 ? 2001-2004 schneider electric all rights reserved contactors type lc1f (115 to 800 a) control circuit: ac or dc supply type lc1f330 lc1f400 lc1f500 l c1f630 lc1f780 lc1f800 environment rated insulation voltage (vi) conforming to iec 60947-4-1/iec 60947-4 v 1000 1000 1000 1000 1000 1000 conforming to vde 0110 gr c v 1500 1500 1500 1500 1500 1500 rated impulse withstand voltage (vimp) test with coil not connected to the power circuit kv888888 conforming to standards meets the essential requirements of the lv & emc directives iec 60947-4, nfc 63-110, vde 0660, bs 5424, jem 1038 approvals e164862 nldx lr 43364 3211 04 ase, csa c22.2 no.14, ul 508, bv, gl, lros, ussr, norsk veritas, rina degree of protection conforming to iec 60529 ip 20 front face with shrouds la9f conforming to vde 0106 protection against direct finger contact with shrouds la9f protective treatment standard version ?th? ambient air temperature around the device storage - 60 to + 80c (- 76 to +176f) operation - 5 to + 55c (23 to + 131f) for operation at 80 to 110% of nominal control voltage permissible at vc - 40 to + 70c (- 40 to + 158f) for operation at nominal control voltage -5 to +55c (23-131 f) maximum operating altitude without derating 3000 m (9800 ft.) operating positions without derating 30 possible, in relation to normal vertical mounting plane shock resistance c 1/2 sine wave = 11 ms contactor open 6 gn 6 gn 9 gn 6 gn 5 gn 6 gn contactor closed 15 gn 15 gn 15 gn 15 gn 15 gn 15 gn vibration resistance c 5 to 300 hz contactor open 2 gn 1.5 gn 2 gn 2 gn 2.5 gn 2 gn contactor closed 5 gn 5 gn 4 gn 4 gn 5.5 gn 4 gn pole characteristics q number of poles 3 or 4 2, 3 or 4 2, 3 or 4 2, 3 or 4 3 or 4 3 rated operational current (ie) (ve 440 v) in ac-3, q 55 c (131 f) a 330 400 500 630 780 800 in ac-1, q 40 c (104 f) a 400 500 700 1000 1600 1000 rated operational voltage (ve) up to v 1000 1000 1000 1000 1000 1000 frequency limits of the operational current p hz 16 2/3 to 200 16 2/3 to 200 16 2/3 to 200 16 2/3 to 200 16 2/3 to 200 16 2/3 to 200 conventional rated thermal current 40 c (104 f) a 400 500 700 1000 1600 1000 rated making capacity i rms to iec 60947-4-1 a 3600 4500 5550 6740 8550 8200 rated breaking capacity i rms conforming to iec 60947-4-1 up to 440 v a 3000 4000 5000 6300 7100 7400 500 v a 2810 3500 4500 5400 6100 6200 660 to 690 v a 2350 3050 3560 4600 5200 5400 1000 v a 1150 1200 2500 3200 3800 3850 permissible short time rating from cold state, no current flowing for preceding 60 minutes 40 c (104 f) for 1 s a 2650 3600 4200 5050 6250 5100 for 5 s a 2650 3600 4200 5050 6250 5100 for 10 s a 2650 3600 4200 5050 6250 5100 for 30 s a 1800 2400 3200 4400 5600 4400 for 1 min a 1300 1700 2400 3400 4600 3400 for 3 min a 900 1200 1500 2200 3000 2200 for 10 min a 750 1000 1200 1600 2200 1600 short-circuit protection by circuit breaker select in accordance with nec and local codes by fuses max 400% of motor fla average impedance per pole at ith and 50 hz m ? 0.28 0.28 0.18 0.12 0.10 0.12 power dissipation per pole for the above operational currents ac-3 w314545486077 ac-1 w447088120250120 mechanical durability at nominal voltage millions of operations 10 10 10 5 5 5 maximum operating rate 55c (131f) ops/ hr 2400 2400 2400 1200 1200 1200 cabling cable size (min-max) awg #6 to 300mcm #4 to 500mcm 2 x #2 to 600mcm 3 x#2 to 600mcm 4 x1/0 to 750mcm 3 x#2 to 600mcm lug dz2fh dz2fj dz2fk dz2fl dz2fx dz2fl tightening torque using dz2f ?? lug bolt lug to contactor lb.-in 310 310 310 510 510 510 wire pressure screw lb.-in 275 500 500 500 500 500 c in the least favorable direction, without change of contact state (coil at vc). q paralleling of poles must be carried out only in acco rdance with the fuse manufacturer's recommendations. p sine wave without interference, above these values, please consult your local square d field sales office.
tesys? f-line contact ors and starters characteristics ? 2001-2004 schneider electric all rights reserved 184 01/04 contactors type lc1f (115 to 800 a) control circuit: ac supply type lc1f115 lc1f150 lc1f185 lc1f225 lc1f265 lc1f330 control circuit characteristics (lx1/lx8 type coils) rated control circuit voltage (vc) 50 or 60 hz v 24 to 1000 24 to 1000 24 to 1000 24 to 1000 48 to 1000 48 to 1000 control voltage limits ( 55 c [131 f]) 50 or 60 hz coils operational 0.85 to 1.1 vc 0.85 to 1.1 vc 0.85 to 1.1 vc 0.85 to 1.1 vc ? ? drop-out 0.35 to 0.55 vc 0.35 to 0.55 vc 0.35 to 0.55 vc 0.35 to 0.55 vc ? ? 40 to 400 hz coils operational ???? 0.85 to 1.1 vc 0.85 to 1.1 vc drop-out ???? 0.35 to 0.55 vc0.35 to 0.55 vc average consumption at 20 c (68 f) and at vc ac 50 hz inrush 50 hz coil va 550 550 805 805 ? ? 40 to 400 hz coilva???? 650650 power factor 0.3 0.3 0.3 0.3 0.9 0.9 ac 50 hz sealed 50 hz coil va 45 45 55 55 ? ? 40 to 400 hz coil va???? 1010 power factor 0.3 0.3 0.3 0.3 0.9 0.9 ac 60 hz inrush 60 hz coil va 660 660 970 970 ? ? 40 to 400 hz coilva???? 650650 power factor 0.3 0.3 0.3 0.3 0.9 0.9 ac 60 hz sealed 60 hz coil va 55 55 66 66 ? ? 40 to 400 hz coilva???? 1010 power factor 0.3 0.3 0.3 0.3 0.9 0.9 heat dissipation w 12 to 16 12 to 16 18 to 24 18 to 24 8 8 operating time c closing ?c? ms 23 to 35 23 to 35 20 to 35 20 to 35 40 to 65 40 to 65 opening ?o? ms 5 to 15 5 to 15 7 to 15 7 to 15 100 to 170 100 to 170 mechanical durability to vc in millions of operating cycles 10 10 10 10 10 10 maximum operating rate at ambient temperature 55 c (131 f) in operating cycles per hour 2400 2400 2400 2400 2400 2400 cabling min/max solid or stranded cable 1 or 2 conductors awg 16/12 16/12 16/12 16/12 16/12 16/12 min/max c.s.a. stranded cable without cable end 1 or 2 conductors mm 2 1/4 1/4 1/4 1/4 1/4 1/4 stranded cable with cable end 1 conductor mm 2 1/4 1/4 1/4 1/4 1/4 1/4 2 conductors mm 2 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 solid cable without cable end 1 or 2 conductors mm 2 1/4 1/4 1/4 1/4 1/4 1/4 tightening torque n ? m/lb-in 1.2/10 1.2/10 1.2/10 1.2/10 1.2/10 1.2/10 mechanical latching the la6dk mechanical latch blocks cannot be mounted on lc1f contactors, for similar operation use cr1f magnetic latching contactors (see page 226). c the closing time ?c? is measured from the moment the coil supply is switched on to initial contact of the main poles. the opening time ?o? is measured from the moment the coil supp ly is switched off to the moment the main poles separate.
tesys? f-line contactors and starters characteristics 185 01/04 ? 2001-2004 schneider electric all rights reserved contactors type lc1f (115 to 800 a) control circuit: ac supply type lc1f400 lc1f500 lc1f630 lc1f780 lc1f800 control circuit characteristics (lx1/lx8 type coils) rated control circuit voltage (vc) 50 or 60 hz v 48 to 1000 48 to 1000 48 to 1000 110 to 500 110 to 440 control voltage limits ( 55 c [131 f]) 50 or 60 hz coils operational????? drop-out ????? 40 to 400 hz coils operational 0.85 to 1.1 vc 0.85 to 1.1 vc 0.85 to 1.1 vc 0.85 to 1.1 vc 0.7 to 1.3 vc drop-out 0.3 to 0.5 vc 0.3 to 0.5 vc 0.25 to 0.5 vc 0.2 to 0.4 vc 0.3 to 0.5 vc average consumption at 20 c (68 f) and at vc ac 50 hz inrush 50 hz coilva????? 40 to 400 hz coil va 1075 1100 1650 2100 1300 power factor 0.9 0.9 0.9 0.9 ? ac 50 hz sealed 50 hz coilva????? 40 to 400 hz coil va 15 18 22 50 15 power factor 0.9 0.9 0.9 0.9 ? ac 60 hz inrush 60 hz coilva????? 40 to 400 hz coil va 1075 1100 1650 2100 1300 power factor 0.9 0.9 0.9 0.9 ? ac 60 hz sealed 60 hz coilva????? 40 to 400 hz coil va 15 18 22 50 15 power factor 0.9 0.9 0.9 0.9 ? heat dissipation w1418202 x 2225 operating time c closing ?c? ms 40 to 75 40 to 75 40 to 80 40 to 80 40 to 80 opening ?o? ms 100 to 170 100 to 170 100 to 200 130 to 230 20 to 40 mechanical durability to vc in millions of operating cycles 10 10 5 5 5 maximum operating rate at ambient temperature 55 c (131 f) in operating cycles per hour 2400 2400 1200 600 600 cabling min/max solid or stranded cable 1 or 2 conductors awg 16/12 16/12 16/12 16/12 16/12 min/max c.s.a. stranded cable without cable end 1 or 2 conductors mm 2 1/4 1/4 1/4 1/4 1/4 stranded cable with cable end 1 conductor mm 2 1/4 1/4 1/4 1/4 1/4 2 conductors mm 2 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 solid cable without cable end 1 or 2 conductors mm 2 1/4 1/4 1/4 1/4 1/4 tightening torque n ? m/lb-in 1.2/10 1.2/10 1.2/10 1.2/10 1.2/10 mechanical latching the la6dk mechanical latch blocks cannot be mounted on lc1f contactors, for similar operation use cr1f magnetic latching contactors (see page 226). c the closing time ?c? is measured from the moment the coil supply is switched on to initial contact of the main poles. the opening time ?o? is measured from the moment the coil supply is switched off to the moment the main poles separate.
tesys? f-line contact ors and starters characteristics ? 2001-2004 schneider electric all rights reserved 186 01/04 contactors type lc1f (115 to 800 a) control circuit: dc supply type lc1f115 lc1f150 lc1f185 lc1f225 lc1f265 lc1f330 control circuit characteristics (lx4/lx8 type coils) rated control circuit voltage (vc) dc v 24 to 460 24 to 460 24 to 460 24 to 460 24 to 460 24 to 460 control voltage limits ( 55 c [131 f]) operational 0.85 to 1.1 vc 0.85 to 1.1 vc 0.85 to 1.1 vc 0.85 to 1.1 vc 0.85 to 1.1 vc 0.85 to 1.1 vc drop-out 0.15 to 0.2 vc 0.15 to 0.2 vc 0.1 to 0.2 vc 0.15 to 0.2 vc 0.15 to 0.2 vc 0.15 to 0.2 vc average consumption at 20 c (68 f) and at vc dc inrush w 560 560 800 800 750 750 sealed w 4.5 4.5 5 5 5 5 average operating time c closing ?f? ms 30 to 40 30 to 40 30 to 40 30 to 40 40 to 50 40 to 50 opening ?o? ms 30 to 50 30 to 50 30 to 50 30 to 50 40 to 65 40 to 65 note: the arcing time depends on the circuit switched by the poles. for normal 3-phase applications, the arcing time is usually less than 10 ms. the load is isolated from the supply after a time equal to the sum of the opening time and the arcing time. mechanical durability at vc in millions of operat ing cycles 10 10 10 10 10 10 maximum operating rate at ambient temperature 55 c (131 f) in operating cycles/hour 2400 2400 2400 2400 2400 2400 cabling min/max solid or stranded cable 1 or 2 conductors awg 16/12 16/12 16/12 16/12 16/12 16/12 min/max c.s.a. stranded cable without cable end 1 conductor mm 2 1/4 1/4 1/4 1/4 1/4 1/4 2 conductors mm 2 1/4 1/4 1/4 1/4 1/4 1/4 stranded cable with cable end 1 conductor mm 2 1/4 1/4 1/4 1/4 1/4 1/4 2 conductors mm 2 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 solid cable without cable end 1 conductor mm 2 1/4 1/4 1/4 1/4 1/4 1/4 2 conductors mm 2 1/4 1/4 1/4 1/4 1/4 1/4 tightening torque nm /lb-in 1.2/10 1.2/10 1.2/10 1.2/10 1.2/10 1.2/10 mechanical latching the la6dk mechanical latch blocks cannot be mounted on lc1f contactors, for similar operation use cr1f magnetic latching contactors (see page 226). c operating times depend on the type of contactor electromagnet and its control mode. the closing time ?c? is measured from the moment the coil supply is switched on to initial contact of the main poles. the opening time ?o? is measured from the moment the coil su pply is switched off to the moment the main poles separate.
tesys? f-line contactors and starters characteristics 187 01/04 ? 2001-2004 schneider electric all rights reserved contactors type lc1f (115 to 800 a) control circuit: dc supply type lc1f400 lc1f500 lc1f 630 lc1f780 lc1f800 control circuit characteristics (lx4/lx8 type coils) rated control circuit voltage (vc) dc v 48 to 460 48 to 460 48 to 460 110 to 460 110 to 440 control voltage limits ( 55 c [131 f]) operational 0.85 to 1.1 vc 0.85 to 1.1 vc 0.85 to 1.1 vc 0.85 to 1.1 vc 0.7 to 1.3 vc drop-out 0.2 to 0.35 vc 0.2 to 0.35 vc 0.2 to 0.35 vc 0.2 to 0.4 vc 0.3 to 0.5 vc average consumption at 20 c (68 f) and at vc dc inrush w 1000 1100 1600 2 x 1000 1300 sealedw6692 x 2115 average operating time c closing ?f? ms 50 to 60 50 to 60 60 to 70 70 to 80 40 to 80 opening ?o? ms 45 to 60 45 to 60 40 to 50 100 to 130 20 to 40 note: the arcing time depends on the circuit switched by the poles. for normal 3-phase applications, the arcing time is usually less than 10 ms. the load is isolated from the supply after a time equal to the sum of the opening time and the arcing time. mechanical durability at vc in millions of op erating cycles 10 10 5 5 5 maximum operating rate at ambient temperature 55 c (131 f) in operating cycles/hour 2400 2400 1200 600 600 cabling min/max solid or stranded cable 1 or 2 conductors awg 16/12 16/12 16/12 16/12 16/12 min/max c.s.a. stranded cable without cable end 1 conductor mm 2 1/4 1/4 1/4 1/4 1/4 2 conductors mm 2 1/4 1/4 1/4 1/4 1/4 stranded cable with cable end 1 conductor mm 2 1/4 1/4 1/4 1/4 1/4 2 conductors mm 2 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 solid cable without cable end 1 conductor mm 2 1/4 1/4 1/4 1/4 1/4 2 conductors mm 2 1/4 1/4 1/4 1/4 1/4 tightening torque nm /lb-in 1.2/10 1.2/10 1.2/10 1.2/10 1.2/10 mechanical latching the la6dk mechanical latch blocks cannot be mounted on lc1f contactors, for similar operation use cr1f magnetic latching contactors (see page 226). c operating times depend on the type of contactor electromagnet and its control mode. the closing time ?c? is measured from the moment the coil supply is switched on to initial contact of the main poles. the opening time ?o? is measured from the moment the coil s upply is switched off to the moment the main poles separate.
tesys? f-line contact ors and starters selection ? contactors ? 2001-2004 schneider electric all rights reserved 188 01/04 selection - contactors control circuit: ac or dc kilowatt ratings for international applications 2-, 3-, and 4-pole contactors standard power ratings of 3-phase motors 50/60 hz in category ac-3 maximum current ( 40 c [104 f]) number of poles catalog number q p weight lb (kg) ac-3 ac-1 220 v 230 v 380 v 400 v 415 v 440 v 660 v 500 v 690 v 1000 v up to 400 v up to 400 v panel mount with screws c kw kw kw kw kw kw kw a a 30 55 59 59 75 80 65 115 200 3 lc1f115 ?? 7.56 (3.430) 4 lc1f1154 ?? 8.44 (3.830) 40 75 80 80 90 100 65 150 250 3 lc1f150 ?? 7.56 (3.430) 4 lc1f1504 ?? 8.44 (3.830) 55 90 100 100 110 110 100 185 275 3 lc1f185 ?? 10.2 (4.650) 4 lc1f1854 ?? 12.0 (5.450) 63 110 110 110 129 129 100 225 315 3 lc1f225 ?? 10.5 (4.750) 4 lc1f2254 ?? 12.2 (5.550) 75 132 140 140 160 160 147 265 350 3 lc1f265 ?? 16.4 (7.440) 4 lc1f2654 ?? 18.8 (8.540) 100 160 180 200 200 220 160 330 400 3 lc1f330 ?? 18.9 (8.600) 4 lc1f3304 ?? 20.9 (9.500) 110 200 220 250 257 280 185 400 500 2 lc1f4002 ?? 17.6 (8.000) 3 lc1f400 ?? 20.0 (9.100) 4 lc1f4004 ?? 22.5 (10.200) 147 250 280 295 355 335 335 500 700 2 lc1f5002 ?? 21.5 (9.750) 3 lc1f500 ?? 25.0 (11.350) 4 lc1f5004 ?? 28.5 (12.950) 200 335 375 400 400 450 450 630 1000 2 lc1f6302 ?? 34.2 (15.500) 3 lc1f630 ?? 41.0 (18.600) 4 lc1f6304 ?? 47.4 (21.500) 220 400 425 425 450 475 450 780 1600 3 lc1f780 ?? 87.1 (39.500) 4 lc1f7804 ?? 105.8 (48.000) 250 450 450 450 450 475 450 800 1000 3 lc1f800 ?? 41.3 (18.750) note: for auxiliary contact blocks and modules (see pages 195 to 196). c the power terminals may be protected by the addition of shrouds, to be ordered separately except lc1f780 . for power terminal lugs, see page 199. q use voltage codes on page 200 ?voltage codes table? to complete catalog number. p the following coil types include one normally open holding circuit contact incorporated in the design of the coil for 3-wire co ntrol applications: lx1ff, fg, fj, fk, fl, lx1fx0422 to fh3802. the following coil types require an additional la ? dn1 ? , ladn2 ? , ladn31, or ladn4. auxiliary contact block: lx1 f h0202 to 0362, lx1fh4402 to 10002, lx8f8 ? w, lx1fx, lx1fx, lx9ff, fg, lx9fh ??? 2, lx9fj, fk, fl, lx4ff, fg fh, fj, fk, fl. lc1f225 lc1f630
tesys? f-line contactors and starters selection ? contactors 189 01/04 ? 2001-2004 schneider electric all rights reserved control circuit: ac or dc horsepower ratings for north american applications 2-, 3-, and 4-pole contactors standard power ratings of 3-phase motors 50/60 hz in category ac-3 maximum current ( 40 c [104 f]) number of poles catalog number q p weight lb (kg) ac-3 ac-1 200 v 208 v 220 v 240 v 460 v 480 v 575 v 600 v panel mount with screws c hp hp hp hp a a 30 40 75 100 115 200 3 lc1f115 ?? 7.56 (3.430) 4 lc1f1154 ?? 8.44 (3.830) 40 50 100 125 150 250 3 lc1f150 ?? 7.56 (3.430) 4 lc1f1504 ?? 8.44 (3.830) 50 60 125 150 185 275 3 lc1f185 ?? 10.2 (4.650) 4 lc1f1854 ?? 12.0 (5.450) current rated 225 315 3 lc1f225 ?? 10.5 (4.750) 4 lc1f2254 ?? 12.2 (5.550) 60 75 150 175 265 350 3 lc1f265 ?? 16.4 (7.440) 4 lc1f2654 ?? 18.8 (8.540) 75 100 200 250 330 400 3 lc1f330 ?? 18.9 (8.600) 4 lc1f3304 ?? 20.9 (9.500) 100 125 250 300 400 500 2 lc1f4002 ?? 17.6 (8.000) 3 lc1f400 ?? 20.0 (9.100) 4 lc1f4004 ?? 22.5 (10.200) 150 200 400 500 500 700 2 lc1f5002 ?? 21.5 (9.750) 3 lc1f500 ?? 25.0 (11.350) 4 lc1f5004 ?? 28.5 (12.950) 250 300 600 800 630 1000 2 lc1f6302 ?? 34.2 (15.500) 3 lc1f630 ?? 41.0 (18.600) 4 lc1f6304 ?? 47.4 (21.500) current rated 780 1600 3 lc1f780 ?? 87.1 (39.500) 4 lc1f7804 ?? 105.8 (48.000) ? 450 800 900 800 1000 3 lc1f800 ?? 41.3 (18.750) note: for auxiliary contact blocks and modules (see pages 195 to 196). c the power terminals may be protected by the addition of shrouds, to be ordered separately except lc1f780 . for power terminal lugs, see page 199. q use voltage codes on page 200 ?voltage codes table? to complete catalog number. p the following coil types include one normally open holding circuit contact incorporated in the design of the coil for 3-wire co ntrol applications: lx1ff, fg, fj, fk, fl, lx1fx0422 to fh3802. the following coil types require an additional la ? dn1 ? , ladn2 ? , ladn31, or ladn4. auxiliary contact block: lx1 f h0202 to 0362, lx1fh4402 to 10002, lx8f8 ? w, lx1fx, lx1fx, lx9ff, fg, lx9fh ??? 2, lx9fj, fk, fl, lx4ff, fg fh, fj, fk, fl. lc1f225 lc1f630
tesys? f-line contact ors and starters mechanical interlocks and power connections ? 2001-2004 schneider electric all rights reserved 190 01/04 mechanical interlocks and power connections components for assembling 3- pole reversing contactors and changeover contactor pa irs, for customer assembly horizontally mounted mechanical interlocks sets of power connections reversers assembled using 2 contactors of identical rating, type: la9f ? 970 reversing contactors 3-pole changeover contactor pairs c la9f ??? 76 la9f ??? 82 lc1f115 lc1f150 lc1f185 lc1f225 lc1f265 lc1f330 lc1f400 lc1f500 lc1f630 lc1f800 vertically mounted mechanical interlocks reversers assembled using 2 contactors of identical rating, type: la9ff4f la9fg4g la9fh4h la9fj4j la9fk4k la9fl4l lc1f115 lc1f150 lc1f185 lc1f225 lc1f265 lc1f330 lc1f400 lc1f500 lc1f630 lc1f800 lc1f780 la9fx970 c for 4-pole changeover contactor pairs, see pages 193 and 194. a1 a1 a2 a2 1 2 3 4 5 6 1 2 3 4 5 6 l1 l2 l3 u v w a2 a2 a1 a1 1 2 3 4 5 6 3 4 5 6 1/l3 1/l2 1/l1 l2 1 2 l1 2/l1 2/l2 2/l3 l3
tesys? f-line contactors and starters mechanical interlocks and power connections 191 01/04 ? 2001-2004 schneider electric all rights reserved components for assembling 3-pole reversing contactors and changeover contactor pairs, for customer assembly. how to order: components are available for customer assembly of f- line reversing contactors and changeover contactors. for example the following components must be ordered to build a 75 hp @ 460 v reversing contactor with a 120 v/60 hz coil: quantity catalog number description 2 lc1f115g6 contactors 6 dz2ff1 lugs 2 la1dn ? 1 auxiliary contact block 1 la9ff976 power connections 1 la9ff970 mechanical interlock using 2 contactors of identical rating contactor type c set of power connections mechanical interlock catalog number weight lb (kg) kit catalog number weight lb (kg) for assembly of 3-pole reversing contactors for motor control horizontally mounted lc1f115 la9ff976 1.3 (0.600) la9ff970 0.13 (0.060) lc1f150 la9f15076 1.3 (0.600) la9ff970 0.13 (0.060) lc1f185 la9fg976 1.7 (0.780) la9fg970 0.13 (0.060) lc1f225 la9f22576 3.3 (1.500) la9fg970 0.13 (0.060) lc1f265 la9fh976 3.3 (1.500) la9fj970 0.31 (0.140) lc1f330 la9fj976 4.6 (2.100) la9fj970 0.31 (0.140) lc1f400 la9fj976 4.6 (2.100) la9fj970 0.31 (0.140) lc1f500 la9fk976 5.2 (2.350) la9fj970 0.31 (0.140) lc1f630 or f800 la9fl976 (8.4 3.800) la9fl970 0.33 (0.150) vertically mounted lc1f115 or f150 k ? la9ff4f 0.76 (0.345) lc1f185 k ? la9fg4g 0.77 (0.350) lc1f225 k ? la9fg4g 0.77 (0.350) lc1f265 or f330 k ? la9fh4h 2.34 (1.060) lc1f400 k ? la9fj4j 2.64 (1.200) lc1f500 k ? la9fk4k 2.64 (1.200) lc1f630 or f800 k ? la9fl4l 2.64 (1.220) lc1f780 q ? la9fx970 q 13.4 (6.100) for assembly of 3-pole changeover contactor pairs f horizontally mounted lc1f115 la9ff982 1.0 (0.460) la9ff970 0.13 (0.060) lc1f150 la9f15082 1.0 (0.460) la9ff970 0.13 (0.060) lc1f185 la9fg982 1.3 (0.610) la9fg970 0.13 (0.060) lc1f225 la9f22582 2.6 (1.200) la9fg970 0.13 (0.060) lc1f265 la9fh982 2.6 (1.200) la9fj970 0.31 (0.140) lc1f330 la9fj982 4.0 (1.800) la9fj970 0.31 (0.140) lc1f400 la9fj982 4.0 (1.800) la9fj970 0.31 (0.140) lc1f500 la9fk982 5.1 (2.300) la9fj970 0.31 (0.140) lc1f630 or f800 la9fl982 7.5 (3.400) la9fl970 0.33 (0.150) vertically mounted lc1f115 or f150 k ? la9ff4f 0.76 (0.345) lc1f185 k ? la9fg4g 0.77 (0.350) lc1f225 k ? la9fg4g 0.77 (0.350) lc1f265 or f330 k ? la9fh4h 2.34 (1.060) lc1f400 k ? la9fj4j 2.64 (1.200) lc1f500 k ? la9fk4k 2.64 (1.200) lc1f630 or f800 k ? la9fl4l 2.64 (1.220) lc1f780 p ? la9fx970 p 17.2 (7.800) c to order the 2 contactors: see pages 188 and 189. order 2 contact blocks la1dn ? 1 to obtain electrical interlocking between the 2 contactors: see pages 194 and 195. k all power connections are to be made by the customer, except for contactors type lc1f780 . q double mechanical interlock mechanism with 2 interlock connecting rods and 3 power connecting links. f for assembly of 4-pole changeover contactor pairs, see pages 192 and 193. p double mechanical interlock mechanism with 2 interlock connecting rods and 4 power connecting links.
tesys? f-line contact ors and starters mechanical interlocks and power connections ? 2001-2004 schneider electric all rights reserved 192 01/04 components for assembling 3- and 4-pole change over contactor pairs, for customer assembly horizontally mounted mechanical interlocks sets of power connections reversers assembled using 2 contactors of identical rating, type: la9f ? 970 4-pole changeover contactor pairs c la9f ??? 77 lc1f1154 lc1f1504 lc1f1854 lc1f2254 lc1f2654 lc1f3304 lc1f4004 lc1f5004 lc1f6304 vertically mounted mechanical interlocks reversers assembled using 2 contactors of identical rating, type: la9ff4f la9fg4g la9fh4h la9fj4j la9fk4k la9fl4l la9fx971 lc1f1154 lc1f1504 lc1f1854 lc1f2254 lc1f2654 lc1f3304 lc1f4004 lc1f5004 lc1f6304 reversers assembled using 2 contactors of different ratings, type: la9fg4f la9fh4f la9fj4f la9fk4f la9fl4f la9fh4g la9fj4g la9fk4g la9fl4g la9fj4h la9fk4h la9fl4k la9fk4j la9fl4j la9fl4k lc1f115 or f1154 lc1f150 or f1504 lc1f185 or f1854 lc1f225 or f2254 lc1f265 or f2654 lc1f330 or f3304 lc1f400 or f4004 lc1f500 or f5004 lc1f630 or f6304 lc1f800 reversers assembled using 3 contactors of identical or different ratings, type: la9f ? 4 ? 4 ? lc1f115 or f1154 lc1f150 or f1504 lc1f185 or f1854 lc1f225 or f2254 lc1f265 or f2654 lc1f330 or f3304 lc1f400 or f4004 lc1f500 or f5004 lc1f630 or f6304 lc1f800 warning: the contactor ratings must be in decreasing size from top to bottom (largest size at top and smallest size at bottom). c for 3-pole changeover contactor pairs, see pages 190 and 191. a1 a2 a1 a2 1 2 3 4 5 6 3 4 5 6 7 8 1n 1/l3 1/l2 l2 1 2 l1 7 8 1/l1 2/l1 2/l2 2/l3 2n l3 n
tesys? f-line contactors and starters mechanical interlocks and power connections 193 01/04 ? 2001-2004 schneider electric all rights reserved components for assembling 3 an d 4-pole changeover contactor pairs, for customer assembly for additional information see how to order on page 191 . using 2 contactors of identical rating for assembly of 4-pole changeover contactor pairs q contactor type c set of power connections mechanical interlock catalog number weight lb (kg) ki t catalog number weight lb (kg) horizontally mounted lc1f1154 la9ff977 1.0 (0.460) la9ff970 0.13 (0.060) lc1f1504 la9f15077 1.0 (0.460) la9ff970 0.13 (0.060) lc1f1854 la9fg977 1.3 (0.610) la9fg970 0.13 (0.060) lc1f2254 la9f22577 2.6 (1.200) la9fg970 0.13 (0.060) lc1f2654 la9fh977 2.6 (1.200) la9fj970 0.30 (0.140) lc1f3304 la9fj977 4.0 (1.800) la9fj970 0.30 (0.140) lc1f4004 la9fj977 4.0 (1.800) la9fj970 0.30 (0.140) lc1f5004 la9fk977 5.1 (2.300) la9fj970 0.30 (0.140) lc1f6304 la9fl977 7.5 (3.400) la9fl970 0.33 (0.150) vertically mounted lc1f1154 or f1504 k ? la9ff4f 0.76 (0.345) lc1f1854 k ? la9fg4g 0.77 (0.350) lc1f2254 k ? la9fg4g 0.77 (0.350) lc1f2654 or f3304 k ? la9fh4h 2.33 (1.060) lc1f4004 k ? la9fj4j 2.64 (1.200) lc1f5004 k ? la9fk4k 2.64 (1.200) lc1f6304 k ? la9fl4l 2.70 (1.220) lc1f7804 f ? la9fx971 17.2 (7.800) using 2 contactors of different ratings for assembly of 3 or 4-pole changeover contactor pairs contactor type c mechanical interlock kit catalog number weight lb (kg) vertically mounted at bottom at top lc1f115 or f1154 or lc1f150 or f1504 lc1f185 or f1854 la9fg4f 0.77 (0.350) lc1f225 or f2254 la9fg4f 0.77 (0.350) lc1f265 or f2654 la9fh4f 1.92 (0.870) lc1f330 or f3304 la9fh4f 1.92 0.870) lc1f400 or f4004 la9fj4f 2.05 (0.930) lc1f500 or f5004 la9fk4f 2.07 (0.940) lc1f630, f6304 or f800 la9fl4f 2.07 (0.940) lc1f185 or f1854 or lc1f225 or f2254 lc1f265 or f2654 la9fh4g 1.90 0.860) lc1f330 or f3304 la9fh4g 1.90 (0.860) lc1f400 or f4004 la9fj4g 2.07 (0.940) lc1f500 or f5004 la9fk4g 2.07 (0.940) lc1f630, f6304 or f800 la9fl4g 2.09 (0.950) lc1f265 or f2654 or lc1f330 or f3304 lc1f400 or f4004 la9fj4h 2.50 (1.130) lc1f500 or f5004 la9fk4h 2.50 (1.130) lc1f630, f6304 or f800 la9fl4h 2.51 (1.140) lc1f400 or f4004 lc1f500 or f5004 la9fk4j 2.64 (1.200) lc1f630, f6304 or f800 la9fl4j 2.70 (1.210) lc1f500 or f5004 lc1f630, f6304 or f800 la9fl4k 2.70 (1.210) q for assembly of 3-pole changeover contactor pairs, see pages 190 and 191. c to order the 2 contactors: see pages 188 and 189. order 2 contact blocks ladn ? 1 to obtain electrical interlocking between the 2 contactors: see pages 194 and 195. k all power connections are to be made by the customer, except for contactors type lc1f780 . f double mechanical interlock mechanism with 2 interlock connecting rods and 4 power connecting links. for assembly of reversers using 3 contactors, vertically mounted, see pages 191 and 192.
tesys? f-line contact ors and starters auxiliary cont acts and timers ? 2001-2004 schneider electric all rights reserved 194 01/04 auxiliary contacts and timers aaa la1dx, la1dy, la1dz ladr ladt lads ladn ladc ladn lc1f ladn10 ladn01
tesys? f-line contactors and starters auxiliary contacts and timers 195 01/04 ? 2001-2004 schneider electric all rights reserved contactors and reversing contactors type lc1f auxiliary contact blocks and interface module instantaneous auxili ary contact blocks for use in normal operating environments number of contacts max. number of blocks per contactor auxiliary contacts catalog number weight lb (kg) side clip-on mounting kf n.o. n.c. 1 1 ??1? ladn10 0.04 (0.020) ???1 ladn01 0.04 (0.020) 2 2 ??11 ladn11 0.07 (0.030) ??2? ladn20 0.07 (0.030) ???2 ladn02 0.07 (0.030) 4 2 ??22 ladn22 0.11 (0.050) ??13 ladn13 0.11 (0.050) ??4? ladn40 0.11 (0.050) ???4 ladn04 0.11 (0.050) ??31 ladn31 0.11 (0.050) ??22 c ladc22 0.11 (0.050) with terminal referencing conforming to standard en 50012 l 2 2 ??11 ladn11p 0.07 (0.030) ??11 ladn11g 0.07 (0.030) 4 2 ??22 ladn22p 0.11 (0.050) ??22 ladn22g 0.11 (0.050) l see page 216 for actual markings. instantaneous auxili ary contact blocks with dust and damp protected contacts for use in harsh industrial environments number of contacts max. number of blocks per contactor auxiliary contacts catalog number weight lb (kg) side clip-on mounting kf n.o. n.c. 2 2 2??? la1dx20 0.09 (0.040) 22 ?? la1dy20 0.09 (0.040) 4 2 2?2? la1dz40 0.11 (0.050) 2?11 la1dz31 0.11 (0.050) time delay auxiliary contacts number of contacts max. number of blocks per contactor time delay catalog number weight lb (kg) side clip-on mounting type range (s) 1 n.o. + 1 n.c. 2 ondelay 0.1 to 3 q ladt0 0.13 (0.060) 0.1 to 30 ladt2 0.13 (0.060) 10 to 180 ladt4 0.13 (0.060) 1 to 30 p lads2 0.13 (0.060) offdelay 0.1 to 3 q ladr0 0.13 (0.060) 0.1 to 30 ladr2 0.13 (0.060) 10 to 180 ladr4 0.13 (0.060) k sealed dust tight contacts. f ground terminal connections. c including 1 n.o. + 1 n.c. make before break. q with extended scale from 0.1 to 0.6 s. p with switching time of 40 ms 15 ms between opening of the n.c. contact and closing of the n.o. contact.
tesys? f-line contact ors and starters accessories and spare parts ? 2001-2004 schneider electric all rights reserved 196 08/04 accessories and spare parts contactors and reversing contactors type lc1f suppressor blocks and cabling accessories suppressor blocks type of suppressor specifi cations coil voltage range cat alog number weight lb (kg) rc (resistor-capacitor) used on ac only limits transients to 3x uc max. increases contactor drop out time 10 to 30 % 24 - 48 la4frce 0.07 (0.030) 50 - 110 la4frcf 0.07 (0.030) 127 - 240 la4frcp 0.07 (0.030) 265 - 415 la4frcv 0.07 (0.030) varistor used on ac or dc limits transients to 2 x uc max. 24 - 48 la4fve 0.07 (0.030) 50 - 110 la4fvf 0.07 (0.030) 127 - 240 la4fvp 0.07 (0.030) 265 - 415 la4fvv 0.07 (0.030) bi-directional diode used on ac or dc limits transients to 2.5 x uc max. 24 - 48 la4fte 0.07 (0.030) 50 - 110 la4ftf 0.07 (0.030) 127 - 240 la4ftp 0.07 (0.030) 265 - 415 la4ftv 0.07 (0.030) diode used on dc only no overvoltage polarity sensitive increases contactor drop out time 300-400% 24 - 48 la4fde 0.07 (0.030) 55 - 110 la4fdf 0.07 (0.030) 125 - 250 la4fdp 0.07 (0.030) 280 - 440 la4fdv 0.07 (0.030) mounting bracket (for 35mm din rail or pane l mounting) for suppressor block la9d09981 0.02 (0.010) cabling accessories links for parallel connection of poles (in pairs) for use on 4-pole contactors set of 4 links weight lb (kg) set catalog number lc1f1154 la9ff602 0.44 (0.200) lc1f1504, f1854 la9fg602 0.77 (0.350) lc1f2254, f2654, f3304, f4004 la9fh602 2.20 (1.000) lc1f5004 la9fk602 3.85 (1.750) lc1f6304 la9fl602 6.61 (3.000) links for ?star? connection of 3 poles lc1f115 la9ff601 0.08 (0.035) lc1f150, f185 la9fg601 0.11 (0.050) lc1f225, f265, f330, f400 la9fh601 0.26 (0.120) lc1f500 la9fk601 0.40 (0.180) lc1f630, f800 la9fl601 1.21 (0.550) control circuit voltage take-off from power terminals for use on contactors mounted on bolt size sold in lots of unit catalog number weight lb (kg) lc1f115 m6 10 dz3fa3 0.008 (0.004) lc1f150, f185 m8 10 dz3ga3 0.008 (0.004) lc1f225 to f500 m10 10 dz3ha3 0.013 (0.006) lc1f630, f800 m12 10 dz3ja3 0.019 (0.009) la9d09981 l a9f ? 601 d z3fa3 la9f ? 602 la9f980
tesys? f-line contactors and starters accessories and spare parts 197 01/04 ? 2001-2004 schneider electric all rights reserved contactors and reversing contactors type lc1f suppressor blocks an d cabling accessories right-angled connectors for contactors or thermal overload relays for use on connector set of 3 connectors contactors thermal overload relays width t ype set catalog number weight lb (kg) lc1f115 lr ? f5 ? 67, lr1f105, f125 0.59" (15 mm) rear la9ff981 0.13 (0.060) side la9ff979 0.53 (0.240) large s. area la9ff980 0.33 (0.150) lc1f150, f185 lr ? f5 ? 69, f5 ? 71 0.79" (20 mm) rear la9fg981 0.18 (0.080) side la9fg979 0.77 (0.350) large s. area la9fg980 0.44 (0.200) lc1f225, f265. f330, f400 lr ? f6 ? 73, f6 ? 75, f6 ? 77 0.98" (25 mm) rear la9fj981 0.95 (0.430) side la9fj979 1.65 (0.750) large s. area la9fj980 1.08 (0.490) lc1f500 lr ? f7 ? 79, f7 ? 81 1.18" (30 mm) rear la9fk981 1.06 (0.480) side la9fk979 2.03 (0.920) large s. area la9fk980 1.76 (0.800) lc1f630, f800 lr ? f8 ? 83, f8 ? 85 1.57" (40 mm) rear la9fl981 2.67 (1.210) side la9fl979 5.66 (2.570) large s. area la9fl980 7.03 (3.190) connection accessories for reversing contactors or star-delta contactors combined with a thermal overload relay for use on width of connector plates set of 3 bus bars contactors thermal overload relays set catalog number weight lb (kg) lc1f115 lr9f5357, f5363 f5367, f5369 0.59" (15 mm) la7f401 0.24 (0.110) lc1f150 and f185 lr9f5357, f5363 f5367, f5369 0.79" (20 mm) la7f402 0.24 (0.110) lc1f225 and f265 lr9f5371 0.98" (25 mm) la7f403 0.35 (0.160) lc1f330 and f400 lr9f7375 and f7379 0.98" (25 mm) la7f404 0.35 (0.160) lc1f400 lr9f7381 0.98" (25 mm) la7f404 0.35 (0.160) lc1f500 lr9f7375, f7379 f7381 1.18" (30 mm) la7f405 0.60 (0.270) lc1f630 lr9f7381 1.57" (40 mm) la7f406 1.30 (0.600) la9f ? 981 l a9f ? 979 la9f ? 980
tesys? f-line contact ors and starters accessories and spare parts ? 2001-2004 schneider electric all rights reserved 198 01/04 contactors and reversing contactors type lc1f cabling accessories and spare parts lug kits lugs can be ordered either individually (for 2-pole and 4-pole contactors) or in sets of 6 (for 3-pole contactors). mounting hardware is provided with the contactors, not the kits. single lug set of six lugs cable size awg range suitable for contactor lc1 ???? / cr1 ???? suitable for overload relay lr9 ????? q dz2ff1 dz2ff6 14 to 2/0 f115 none dz2fg1 dz2fg6 6 to 3/0 f150, f185 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 dz2fh1 dz2fh6 6 to 300 mcm f265, f330 lr9f ? 71 dz2fj1 dz2fj6 4 to 500 mcm f400 none dz2fk1 dz2fk6 2x2 to 600 mcm f500 f7 ? 75, f7 ? 79 dz2fl ? c dz2fl6 3x2 to 600 mcm f630, f800 f7 ? 81 dzf2fx1 dz2fx6 4x1/0 to 750 mcm f780 none insulated terminal blocks for use on 3-pole contactors cable size awg range set of 2 blocks set catalog number weight lb (kg) lc1f115, f150, f185 (provides ip20 touch-safe protection) #6 to 300 mcm la9f103 1.23 (0.560) power terminal protection shrouds these clear plastic protective shrouds are an effective means to meet international touch-safe requirements for power terminals . they are designed to be used with power cables that have been bolted to the terminal. note: the protection shrouds do not attach to contactors or overl oads utilizing dz2f lug kits. for use with 2-, 3-, and 4-pole contactors number of shrouds per set set catalog number weight lb (kg) lc1f115 6 la9f701 0.55 (0.250) lc1f150, f185 cr1f150, f185 6 la9f702 0.55 (0.250) lc1f225, f265, f330, f400 and f4002, f500 and f5002 cr1f265, f400 and f500 6 la9f703 0.55 (0.250) lc1f630, f6302 and f800 cr1f630 6 la9f704 0.55 (0.250) lc1f1154 8 la9f706 0.66 (0.300) lc1f1504 and f1854 8 la9f707 0.66 (0.300) lc1f2254, f2654, f3304, f4004, f5004 8 la9f708 0.66 (0.300) lc1f6304 8 la9f709 0.66 (0.300) q when direct mounting the lr9f to an lc1f or cr1f contactor, lugs of different sizes may be required. see page 220 for additional information. c for 3-pole f630 contactors, order dz2fl1 for l1 and t3, dz2fl2 for l2 and t2, and dz2pl3 for l3 and t1 terminals. for 4-pole f6304 contactors, order dz2fl1 for l1 and t4, dz2fl2 for l2, t2, l3 and t3, and dz2fl3 for l4 and t1 terminals. la9f103 la9f701 dz2f ??
tesys? f-line contactors and starters accessories and spare parts 199 01/04 ? 2001-2004 schneider electric all rights reserved contactors and reversing contactors type lc1f spare parts main contact sets per pole: 2 stationary contacts and 1 moving contact, 2 deflectors, 1 leaf spring, screws and washers for contactor type repla cement for catalog number weight lb (kg) 2-pole lc1f4002 2 poles la5f400802 3.00 (1.350) lc1f5002 2 poles la5f500802 4.30 (1.950) lc1f6302 2 poles la5f630802 10.3 (4.700) 3-pole lc1f115, f150 3 poles la5ff431 0.60 (0.270) lc1f185, f225 3 poles la5fg431 0.77 (0.350) lc1f265 3 poles la5fh431 1.45 (0.660) lc1f330, f400 3 poles la5f400803 4.40 (2.000) lc1f500 3 poles la5f500803 6.50 (2.950) lc1f630 3 poles la5f630803 13.4 (6.100) lc1f780 1 pole la5f780801 c 10.4 (4.700) 3 poles la5f780803 29.1 (13.200) lc1f800 3 poles la5f800803 13.4 (6.100) 4-pole lc1f1504, f1154 4 poles la5ff441 0.80 (0.360) lc1f1854, f2254 4 poles la5fg441 1.20 (0.465) lc1f2654 4 poles la5fh441 1.94 (0.880) lc1f3304, f4004 4 poles la5f400804 5.95 (2.700) lc1f5004 4 poles la5f500804 8.59 (3.900) lc1f6304 4 poles la5f630804 17.9 (8.150) lc1f7804 1 pole la5f780801 c 10.36 (4.700) 4 poles la5f780804 38.1 (17.300) arc chambers for contactor type repla cement for catalog number weight lb (kg) 2-pole lc1f4002 2 poles la5f400250 1.91 (0.870) lc1f5002 2 poles la5f500250 2.75 (1.250) lc1f6302 2 poles la5f630250 4.62 (2.100) 3-pole lc1f115 3 poles la5f11550 1.08 (0.490) lc1f150 3 poles la5f15050 1.08 (0.490) lc1f185 3 poles la5f18550 1.47 (0.670) lc1f225 3 poles la5f22550 1.47 (0.670) lc1f265 3 poles la5f26550 2.03 (0.920) lc1f330 3 poles la5f33050 2.90 (1.300) lc1f400 3 poles la5f40050 2.90 (1.300) lc1f500 3 poles la5f50050 4.08 (1.850) lc1f630 3 poles la5f63050 6.94 (3.150) lc1f780 1 pole la5f780150 c 4.63 (2.100) lc1f800 3 poles la5f80050 6.94 (3.150) 4-pole lc1f1154 4 poles la5f115450 1.45 (0.660) lc1f1504 4 poles la5f150450 1.45 (0.660) lc1f1854 4 poles la5f185450 2.00 (0.910) lc1f2254 4 poles la5f225450 2.20 (1.000) lc1f2654 4 poles la5f265450 2.70 (1.220) lc1f3304 4 poles la5f330450 3.83 (1.740) lc1f4004 4 poles la5f400450 f 3.83 (1.740) lc1f5004 4 poles la5f500450 f 5.51 (2.500) lc1f6304 4 poles la5f630450 q 9.26 (4.200) lc1f7804 1 pole la5f780150 c 9.63 (2.100) c comprising 2 identical items per pole. f comprising two 2-pole arc chambers. q comprising single-pole arc chambers. la5fg431 la5f40050
tesys? f-line contact ors and starters f-line voltage code table ? 2001-2004 schneider electric all rights reserved 200 01/04 f-line voltage code table f-line voltage code voltage frequency f-line (see notes at end of table) lc1f115 - f225 note f1, f2 lc1f265 - f400 note f1, f2 lc1f500 - f630 note f1, f2 lc1f780 note f1, f2 lc1f800 note f1, f2, f3 5low consump dc ----- 12 50/60 ----- 50----- dc----- low consump dc ----- wide range dc ----- 20 50/60----- 50----- 60----- dc----- low consump dc ----- 24 50/60----- 50b5---- 60b6---- 40-400 - b7 note f4 --- dc bd bd note f4 --- low consump dc ----- wide range dc ----- 36 50/60----- dc----- wide range dc ----- 42 50/60----- 50d5---- 60----- 48 50/60----- 50e5---- 60e6---- 40-400 e7 e7 e7 - - dc ed ed ed - - low consump dc ----- wide range dc ----- 60 50/60----- dc----- 72 dc----- low consump dc ----- wide range dc ----- 96 low consump dc ----- 100 50/60----- dc----- 110 50/60----- 50f5---- 60f6---- 40-400 f7 f7 f7 f7 - dc fd fd fd fd fw low consump dc ----- wide range dc ----- 110/127 40-400 - - - - fe7 115 50/60----- 50fe5---- 40-400 fe7 fe7 fe7 fe7 - 120 50/60----- 50----- 60g6---- 40-400 g7 g7 note f5 f7 f7 - dc----fw low consump dc ----- 125dc gdgdgdgd - 127 50/60----- 60g5---- 40-400 g7 g7 g7 g7 - 155dc----- 174dc----- 200 50/60----- dc----- 200/208 50/60----- 60 l6 - - - - 40-400 - l7 l7 l7 - 208 50/60----- 60----- 40-400 l7 - - - - f-line voltage code voltage frequency f-line (see notes at end of table) lc1f115 - f225 note f1, f2 lc1f265 - f400 note f1, f2 lc1f500 - f630 note f1, f2 lc1f780 note f1, f2 lc1f800 note f1, f2, f3
tesys? f-line contactors and starters f-line voltage code table 201 01/04 ? 2001-2004 schneider electric all rights reserved 220 50/60----- 50m5---- 60m6---- 40-400 m7 m7 m7 m7 - dc - mdmdmd - low consump dc ----- wide range dc ----- 220/230 50/60----- 50----- 60----- 40-400----- dcmd---- 220/240 40-400 - - - - p7 dc----mw 230 50/60----- 50p5---- 60----- 40-400 p7 p7 p7 p7 - dc----- 230/240 50/60 - - - - - 240 50/60----- 50u5---- 60u6---- 40-400 u7 u7 u7 u7 - dc----- 250 dc ud ud ud ud - low consump dc ----- 256 50/60----- 50----- 277 50/60----- 50w5---- 40-400 - w7 w7 w7 - 380 50/60----- 50q5---- 60q6---- 40-400 q7 q7 q7 q7 - 380/400 50/60----- 50----- 60----- 40-400----- dc----qw 380/440 40-400 - - - - v7 f-line voltage code voltage frequency f-line (see notes at end of table) lc1f115 - f225 note f1, f2 lc1f265 - f400 note f1, f2 lc1f500 - f630 note f1, f2 lc1f780 note f1, f2 lc1f800 note f1, f2, f3 400 50/60----- 50v5---- 40-400v7v7v7v7 - 400/415 50/60 - - - - - 415 50/60----- 50n5---- 40-400n7n7n7n7 - 415-440 50----- 40-400----- 440 50/60----- 50----- 60r6---- 40-400r7r7r7r7 - dc - rd rd rd - 440/460 dc rd - - - - 460/480 60 q5 - - - - 480 50/60----- 50----- 60 - - - n7 - 40-400 - s7, note f4 - - - 500 50/60----- 50s5---- 40-400s7s7s7s7 - 575 50/60----- 60----- 600 50/60----- 60----- 40-400 - - x7 - - 660 50----- 60y6---- 660/690 50/60 - - - - - f-line notes: f1 for operating ranges refer to technical data section of the f-line contactors. ranges vary as a function of the supply (ac/dc). f2 for non-stock voltage codes, order contactor and coil separately. see page 234 for coils. f3 built in surge suppressor included on lc1f800 coils. f4 for use with lc1f265 and lc1f330 only. f5 for lc1f400 contactor with 120 vac coil, use f7 code. f-line voltage code voltage frequency f-line (see notes at end of table) lc1f115 - f225 note f1, f2 lc1f265 - f400 note f1, f2 lc1f500 - f630 note f1, f2 lc1f780 note f1, f2 lc1f800 note f1, f2, f3
tesys? f-line contact ors and starters selection - coils ? 2001-2004 schneider electric all rights reserved 202 01/04 selection - coils contactors type lc1f coils for lc1f115 to f225, ac supply 50 to 60 hz maximum ambient air temperature: 55 c (131 f); above this, use an lx9f coil, see page 208 to 209. operating cycles/hour ( 55 c [131 f]): 2400. control circuit voltage average resistance at 20 c (68 f) 10% inductance of closed circuit voltage code catalog number weight lb (kg) vc 50 hz vc 60 hz vv ? h for contactors lc1f115 and lc1f150 24 ? 0.27 0.04 b5 lx1ff024 0.95 (0.430) 42 ? 0.94 0.13 ? lx1ff042 0.95 (0.430) ?48 0.78 0.11 e6 lx1ff040 0.95 (0.430) 48 ? 1.17 0.16 e5 lx1ff048 0.95 (0.430) ?110 4.55 0.59 f6 lx1ff092 0.95 (0.430) ?115/120 4.77 0.64 g6 lx1ff095 0.95 (0.430) 110/115 ? 6.38 0.86 f5 lx1ff110 0.95 (0.430) 127 ? 9.14 1.15 g5 lx1ff127 0.95 (0.430) ?200/208 14.5 1.87 l6 lx1ff162 0.95 (0.430) ?220 18.4 2.38 m6 lx1ff184 0.95 (0.430) ?230/240 18.9 2.5 u6 lx1ff187 0.95 (0.430) 220/230 265/277 28.1 3.44 m5 lx1ff220 0.95 (0.430) 240 ? 31.1 4.1 u5 lx1ff240 0.95 (0.430) ?380 57.2 7.05 q6 lx1ff316 0.95 (0.430) ?415 67.9 8.21 n6 lx1ff340 0.95 (0.430) ?440 72.6 9.21 r6 lx1ff360 0.95 (0.430) 380/400 460/480 86.9 10.3 q5 lx1ff380 0.95 (0.430) 415/440 ? 95.1 12 n5 lx1ff415 0.95 (0.430) 500 ? 141 17 s5 lx1ff500 0.95 (0.430) ?660 172 20.3 y6 lx1ff550 0.95 (0.430) 660 ? 254 28.9 y5 lx1ff660 0.95 (0.430) ?1000 414 48.9 ? lx1ff850 0.95 (0.430) 1000 ? 610 68.5 ? lx1ff1000 0.95 (0.430) specifications average consumption at 20 c (68 f): - inrush 50 hz: 550 va; 60 hz: 660 va. - sealed 50 hz: 45 va; 60 hz: 55 va, cos ? = 0.32. heat dissipation: 12 to 16 w operating time at vc: closing = 23 to 35 ms; opening = 5 to 15 ms for contactors lc1f185 and lc1f225 24 ? 0.18 0.03 b5 lx1fg024 1.21 (0.550) 42 ? 0.57 0.09 ?lx1fg042 1.21 (0.550) ?48 0.47 0.08 e6 lx1fg040 1.21 (0.550) 48 ? 0.71 0.12 e5 lx1fg048 1.21 (0.550) ?110 2.74 0.44 f6 lx1fg092 1.21 (0.550) ?115/120 2.87 0.49 g6 lx1fg095 1.21 (0.550) 110/115 ? 4.18 0.65 f5 lx1fg110 1.21 (0.550) 127 ? 5.35 0.86 g5 lx1fg127 1.21 (0.550) ?200/208 8.8 1.41 l6 lx1fg162 1.21 (0.550) ?220 11.1 1.8 m6 lx1fg184 1.21 (0.550) ?230/240 11.4 1.87 u6 lx1fg187 1.21 (0.550) 220/230 265/277 16.5 2.59 m5 lx1fg220 1.21 (0.550) 240 ? 20.1 3.09 u5 lx1fg240 1.21 (0.550) ?380 34 5.32 q6 lx1fg316 1.21 (0.550) ?415 40.8 6.2 n6 lx1fg340 1.21 (0.550) ?440 43.5 6.94 r6 lx1fg360 1.21 (0.550) 380/400 460/480 51.3 7.75 q5 lx1fg380 1.21 (0.550) 415/440 ? 62.3 9.06 n5 lx1fg415 1.21 (0.550) 500 ? 82.7 12.8 s5 lx1fg500 1.21 (0.550) ?660 103 15.3 y6 lx1fg550 1.21 (0.550) 660 ? 154 21.8 y5 lx1fg660 1.21 (0.550) ?1000 249 36.6 ?lx1fg850 1.21 (0.550) 1000 ? 370 51.6 ? lx1fg1000 1.21 (0.550) specifications average consumption at 20 c (68 f): - inrush 50 hz: 805 va; 60 hz: 970 va. - sealed 50 hz: 55 va; 60 hz: 66 va, cos ? = 0.34. heat dissipation: 18 to 24 w operating time at vc: closing = 20 to 35 ms; opening = 7 to 15 ms lx1ff ??? lx1fg ???
tesys? f-line contactors and starters selection - coils 203 01/04 ? 2001-2004 schneider electric all rights reserved contactors type lc1f coils for lc1f265 to f500, ac supply 40 to 400 hz low sealed consumption. operate on networks with harmonic numbers 7 operating cycles/hour ( 55 c [131 f]) 2400. control circuit voltage vc average resistance at 20 c (68 f) 10% inductance of closed circuit voltage code catalog number weight lb (kg) inrush sealed v ?? h for contactors lc1f265 and lc1f330 24 0.8 20 c b7 lx1fh0242 1.65 (0.750) 48 2.96 72 c e7 lx1fh0482 1.65 (0.750) 110/115 18.7 415 c f7 lx1fh1102 1.65 (0.750) 120/127 22.9 536 c g7 lx1fh1272 1.65 (0.750) 200/208 57.8 1285 c l7 lx1fh2002 1.65 (0.750) 220/230 71.6 1621 c m7 lx1fh2202 1.65 (0.750) 240 71.6 1621 c u7 lx1fh2402 1.65 (0.750) 277 114.3 2425 c w7 lx1fh2772 1.65 (0.750) 380/415 222 5075 c q7 lx1fh3802 1.65 (0.750) 480/500 345 7990 c s7 lx1fh5002 1.65 (0.750) 600/660 521 11 988 c x7 lx1fh6002 1.65 (0.750) 1000 1218 30 124 c ? lx1fh10002 1.65 (0.750) specifications average consumption at 20 c (68 f) for 50 or 60 hz and cos ? = 0.9: - inrush: 600 to 700 va. - sealed: 8 to 10 va. heat dissipation: 8 w operating time at vc: closing = 40 to 65 ms; opening = 100 to 170 ms for contactor lc1f400 48 1.6 29.5 0.18 e7 lx1fj048 2.20 (1.000) 110/120 9.8 230 1.35 f7 lx1fj110 2.20 (1.000) 127 12.8 280 1.75 g7 lx1fj127 2.20 (1.000) 200/208 30 815 4.1 l7 lx1fj200 2.20 (1.000) 220/230 37 1030 5.1 m7 lx1fj220 2.20 (1.000) 230/240 47.5 1320 6.4 u7 lx1fj240 2.20 (1.000) 265/277 61 1700 8.1 w7 lx1fj280 2.20 (1.000) 380/400 120 3310 15.8 q7 lx1fj380 2.20 (1.000) 415/480 145 4070 19.4 n7 lx1fj415 2.20 (1.000) 500 190 4980 25.5 s7 lx1fj500 2.20 (1.000) 550/600 243 6310 27.4 x7 lx1fj600 2.20 (1.000) 1000 720 19 420 84.6 ? lx1fj1000 2.20 (1.000) specifications average consumption at 20 c (68 f) for 50 or 60 hz and cos ? = 0.9: - inrush: 1000 to 1150 va. - sealed: 12 to 18 va. heat dissipation: 14 w operating time at vc: closing = 40 to 75 ms; opening = 100 to 170 ms for contactor lc1f500 48 1.9 33.5 0.19 e7 lx1fk048 2.53 (1.150) 110/120 9.55 260 1.25 f7 lx1fk110 2.53 (1.150) 127 11.5 315 1.5 g7 lx1fk127 2.53 (1.150) 200/208 29 735 3.75 l7 lx1fk200 2.53 (1.150) 220/230 35.5 915 4.55 m7 lx1fk220 2.53 (1.150) 230/240 44.5 1160 5.75 u7 lx1fk240 2.53 (1.150) 265/277 56.5 1490 7.3 w7 lx1fk280 2.53 (1.150) 380/400 112 2980 14.7 q7 lx1fk380 2.53 (1.150) 415/480 143 3730 18.4 n7 lx1fk415 2.53 (1.150) 500 172 4590 22.8 s7 lx1fk500 2.53 (1.150) 550/600 232 5660 23.9 x7 lx1fk600 2.53 (1.150) 1000 679 16 960 72 ? lx1fk1000 2.53 (1.150) specifications average consumption at 20 c (68 f) for 50 or 60 hz, cos ? = 0.9: - inrush: 1050 to 1150 va. - sealed: 16 to 20 va. heat dissipation: 18 w operating time at vc: closing = 40 to 75 ms; opening = 100 to 170 ms c please consult your local square d field sales office. lx1fh ??? 2 lx1fj ??? lx1fk ???
tesys? f-line contact ors and starters selection - coils ? 2001-2004 schneider electric all rights reserved 204 01/04 lx1fl ??? contactors type lc1f coils for lc1f630 to f800, ac supply 40 to 400 hz low sealed consumption. operate on networks with harmonic numbers 7. control circuit voltage vc average resistance at 20 c (68 f) 10% inductance of closed circuit voltage code catalog number weight lb (kg) inrush sealed v ?? h for contactor lc1f630 48 1.1 17.1 0.09 e7 lx1fl048 3.30 (1.500) 110/120 6.45 165 1.85 f7 lx1fl110 3.30 (1.500) 127 8.1 205 1.05 g7 lx1fl127 3.30 (1.500) 200/208 20.5 605 2.65 l7 lx1fl200 3.30 (1.500) 220/240 25.5 730 3.35 m7 lx1fl220 3.30 (1.500) 265/277 31 900 4.1 w7 lx1fl260 3.30 (1.500) 380/400 78 2360 10.5 q7 lx1fl380 3.30 (1.500) 415/480 96 2960 13 n7 lx1fl415 3.30 (1.500) 500 120 3660 16.5 s7 lx1fl500 3.30 (1.500) 550/600 155 4560 19.5 x7 lx1fl600 3.30 (1.500) 1000 474 12 880 56.2 ? lx1fl1000 3.30 (1.500) specifications average consumption at 20 c (68 f) for 50 or 60 hz, cos ? = 0.9: - inrush: 1500 to 1730 va. - sealed: 20 to 25 va. operating cycles/hour ( 55 c [131 f]): 1200. heat dissipation: 20 w operating time at vc: closing = 40 to 80 ms; opening = 100 to 200 ms for contactor lc1f780 replacement rectifier for use with lx1fx kkk coils: dr5tx5s . 110/120 4.95 q 230 q 0.21 f7 lx1fx110 c 6.61 (3.000) 127 6.1 q 280 q 0.26 g7 lx1fx127 c 6.61 (3.000) 200/208 15.5 q 750 q 0.66 l7 lx1fx200 c 6.61 (3.000) 220/240 19.5 q 920 q 0.82 m7 lx1fx220 c 6.61 (3.000) 265/277 29.8 q 1330 q 1.25 w7 lx1fx280 c 6.61 (3.000) 380 60.9 q 2780 q 2.3 q7 lx1fx380 c 6.61 (3.000) 415/480 74.3 q 3340 q 2.8 n7 lx1fx415 c 6.61 (3.000) 500 92 q 4180 q 3.5 s7 lx1fx500 c 6.61 (3.000) specifications average consumption at 20 c (68 f) for 50 or 60 hz, cos ? = 0.9: - inrush: 1900 to 2300 va. - sealed: 44 to 55 va. operating cycles/hour ( 55 c [131 f]): 600. heat dissipation: 2 x 22 w operating time at vc: closing = 40 to 80 ms; opening = 130 to 230 ms for contactor lc1f800 110/127 ? ? ? fw lx4f8fw t 3.64 (1.650) 220/240 ? ? ? mw lx4f8mw t 3.64 (1.650) 380/440 ? ? ? qw lx4f8qw t 3.64 (1.650) specifications operating cycles/hour ( 55 c [131 f]): 600. heat dissipation: 25 w operating time at vc: closing = 40 to 80 ms; opening = 20 to 40 ms c catalog number includes a set of 2 identical coils, to be connected in series. q value for the 2 coils in series. t coil circuit requires a separately mounted rectifier catalog number dr5 te4u.
tesys? f-line contactors and starters selection - coils 205 01/04 ? 2001-2004 schneider electric all rights reserved contactors type lc1f coils for lc1f115 to f400, dc supply low sealed consumption. operate on networks with harmonic numbers 7. operating cycles/hour ( 55 c [131 f]) 2400. control circuit voltage vc average resistance at 20 c (68 f) 10% inductance of closed circuit voltage code catalog number weight lb (kg) inrush sealed v ?? h for contactors lc1f115 and lc1f150 24 1.12 177 11 bd lx4ff024 0.95 (0.430) 48 4.52 715 42.7 ed lx4ff048 0.95 (0.430) 110 21.7 2940 179 fd lx4ff110 0.95 (0.430) 125 26.8 3560 223 gd lx4ff125 0.95 (0.430) 220/230 84 11 100 704 md lx4ff220 0.95 (0.430) 250 105 13 000 868 ud lx4ff250 0.95 (0.430) 440/460 301 48 200 4000 rd lx4ff440 0.95 (0.430) specifications average consumption: - inrush: 543 to 665 w. - sealed: 3.94 to 4.83 w. operating time at vc: closing = 30 to 40 ms; opening = 30 to 50 ms for contactors lc1f185 and lc1f225 24 0.79 169 14.9 bd lx4fg024 1.21 (0.550) 48 3.2 662 55.3 ed lx4fg048 1.21 (0.550) 110 14.9 2810 241 fd lx4fg110 1.21 (0.550) 125 19. 3320 289 gd lx4fg125 1.21 (0.550) 220/230 57.7 10 200 890 md lx4fg220 1.21 (0.550) 250 76. 12 400 1140 ud lx4fg250 1.21 (0.550) 440/460 223 39 700 4210 rd lx4fg440 1.21 (0.550) specifications average consumption: - inrush: 737 to 902 w. - sealed: 4.13 to 5.07 w. operating time at vc: closing = 30 to 40 ms; opening = 30 to 50 ms for contactors lc1f265 and lc1f330 24 0.9 192 26.3 bd lx4fh024 1.63 (0.740) 48 3.49 707 92.9 ed lx4fh048 1.63 (0.740) 110 16.8 3180 424 fd lx4fh110 1.63 (0.740) 125 20.8 3840 530 gd lx4fh125 1.63 (0.740) 220/230 65.7 11 500 1590 md lx4fh220 1.63 (0.740) 250 84 13 900 1910 ud lx4fh250 1.63 (0.740) 440/460 255 44 000 7570 rd lx4fh440 1.63 (0.740) specifications average consumption: - inrush: 655 to 803 w. - sealed: 3.68 to 4.53 w. operating time at vc: closing = 40 to 50 ms; opening = 40 to 65 ms for contactor lc1f400 48 2.5 558 56 ed lx4fj048 2.14 (0.970) 110 12.7 2660 270 fd lx4fj110 2.14 (0.970) 125 15.8 3130 330 gd lx4fj125 2.14 (0.970) 220 47 8820 910 md lx4fj220 2.14 (0.970) 250 61 10 500 1200 ud lx4fj250 2.14 (0.970) 440 236 33 750 4435 rd lx4fj440 2.14 (0.970) specifications average consumption: - inrush: 920 to 1140 w. - sealed: 4 to 7.5 w. operating time at vc: closing = 50 to 60 ms; opening = 45 to 60 ms lx4ff ??? lx4fh ???
tesys? f-line contact ors and starters selection - coils ? 2001-2004 schneider electric all rights reserved 206 01/04 lx4fk ??? contactors type lc1f coils for lc1f500 to f800, dc supply low sealed consumption. control circuit voltage vc average resistance at 20 c (68 f) 10% inductance of closed circuit voltage code catalog number weight lb (kg) inrush sealed v ?? h for contactor lc1f500 48 2.35 515 67 ed lx4fk048 2.40 (1.080) 110 11.5 2450 280 fd lx4fk110 2.40 (1.080) 125 15 2930 400 gd lx4fk125 2.40 (1.080) 220 44 8150 1080 md lx4fk220 2.40 (1.080) 250 56 9650 1350 ud lx4fk250 2.40 (1.080) 440 225 31 300 5270 rd lx4fk440 2.40 (1.080) specifications average consumption: - inrush: 990 to 1220 w. - sealed: 4.5 to 8 w. operating cycles/hour ( 55 c [131 f]): 2400 operating time at vc: closing = 50 to 60 ms; opening = 45 to 60 ms for contactor lc1f630 48 1.7 353 40.5 ed lx4fl048 3.21 (1.450) 110 8.1 1680 180 fd lx4fl110 3.21 (1.450) 125 10 2110 230 gd lx4fl125 3.21 (1.450) 220 31 5160 650 md lx4fl220 3.21 (1.450) 250 38 6080 815 ud lx4fl250 3.21 (1.450) 440 152 23 120 2910 rd lx4fl440 3.21 (1.450) specifications average consumption: - inrush: 1420 to 1920 w. - sealed: 6.5 to 72.5 w. operating cycles/hour ( 55 c [131 f]): 1200 operating time at vc: closing = 60 to 70 ms; opening = 40 to 50 ms for contactor lc1f780 110 6.1 q 280 q 0.26 fd lx4fx110 c 6.61 (3.000) 125 7.7 q 410 q 0.33 gd lx4fx125 c 6.61 (3.000) 220 24.6 q 1100 q 1 md lx4fx220 c 6.61 (3.000) 250 29.8 q 1330 q 1.25 ud lx4fx250 c 6.61 (3.000) 440 92 q 4180 q 3.5 rd lx4fx440 c 6.61 (3.000) specifications average consumption: - inrush: 1960 to 2420 w. - sealed: 42 to 52 w. operating cycles/hour ( 55 c [131 f]): 600 operating time at vc: closing = 70 to 80 ms; opening = 100 to 130 ms for contactor lc1f800 110/127 ??? fw lx4f8fw t 3.64 (1.650) 220/240 ??? mw lx4f8mw t 3.64 (1.650) 380/440 ??? qw lx4f8qw t 3.64 (1.650) specifications operating cycles/hour ( 55 c [131 f]): 600 heat dissipation: 25 w operating time at vc: closing = 40 to 80 ms; opening = 20 to 40 ms c catalog number includes a set of 2 identical coils, to be connected in series. q value of the 2 coils in series. t coil circuit requires a separately mounted rectifier catalog number dr5 te4u.
tesys? f-line contactors and starters selection - coils 207 01/04 ? 2001-2004 schneider electric all rights reserved lx9ff ??? lx9fg ??? contactors type lc1f coils for lc1f115 to f330 (specific applications c ) ac supply, 40 to 400 hz low sealed consumption. high tolerance to inrush voltage drops. immune to micro-breaks (mains supply or contact chain). operate on networks with harmonic numbers 7. control circuit voltage vc average resistance at 20 c (68 f) 10% inductance of closed circuit voltage code catalog number weight lb (kg) inrush sealed v ?? h for contactors lc1f115 and lc1f150 48 3.03 80.2 0.3 e7 lx9ff048 0.95 (0.430) 110/115 14.8 579 2.08 f7 lx9ff110 0.95 (0.430) 127 19 746 2.65 g7 lx9ff127 0.95 (0.430) 220/230 59.4 2190 7.7 m7 lx9ff220 0.95 (0.430) 240 73.5 2750 9.68 u7 lx9ff240 0.95 (0.430) 380/400 173 6540 23 q7 lx9ff380 0.95 (0.430) 415/440 218 8460 30 n7 lx9ff415 0.95 (0.430) 500 262 10 300 36 s7 lx9ff500 0.95 (0.430) specifications average consumption at 20 c (68 f): - inrush: 690 to 855 va. - sealed: 6.6 to 8.1 va. heat dissipation: 5.9 to 7.2 w. operating time at vc: closing = 35 ms; opening = 130 ms. operating cycles/hour ( 55 c [131 f]): < 2400. for contactors lc1f185 and lc1f225 48 2.2 60 0.23 e7 lx9fg048 1.21 (0.550) 110/115 10.4 411 1.46 f7 lx9fg110 1.21 (0.550) 127 13 520 1.85 g7 lx9fg127 1.21 (0.550) 220/230 42.1 1680 5.84 m7 lx9fg220 1.21 (0.550) 240 50.6 2060 7.22 u7 lx9fg240 1.21 (0.550) 380/400 128 4730 16.4 q7 lx9fg380 1.21 (0.550) 415/440 157 5930 20.6 n7 lx9fg415 1.21 (0.550) 500 194 7550 26.3 s7 lx9fg500 1.21 (0.550) specifications average consumption at 20 c (68 f): - inrush: 950 to 1180 va. - sealed: 8.9 to 10.9 va. heat dissipation: 8 to 9.8 w. operating time at vc: closing = 35 ms; opening = 130 ms. operating cycles/hour ( 55 c [131 f]): < 2400. for contactors lc1f265 and lc1f330 48 2.96 72 q ? lx9fh0482 1.65 (0.750) 110/115 18.7 415 q ? lx9fh1102 1.65 (0.750) 120/127 22.9 156 q ? lx9fh1272 1.65 (0.750) 220/230 71.6 1621 q ? lx9fh2202 1.65 (0.750) 380/415 222 5075 q ? lx9fh3802 1.65 (0.750) 500 345 7990 q ? lx9fh5002 1.65 (0.750) specifications average consumption at 20 c (68 f): - inrush: 560 to 660 va. - sealed: 8 to 10 va. heat dissipation: 8.4 to 10.4 w. operating time at vc: closing = 45 ms; opening = 25 ms. operating cycles/hour ( 55 c [131 f]): < 3600. c application examples:  hoisting (inching, high operating rate).  normal standby (distributed power supplies). these coils are specifically designed for use at high ambient temperature (mounting in mccs, non ventilated enclosures, etc.). q please consult your local square d field sales office.
tesys? f-line contact ors and starters selection - coils ? 2001-2004 schneider electric all rights reserved 208 01/04 lx9fk ??? lx9fj ??? lx9fl ??? contactors type lc1f coils for lc1f400 to f630 (specific applications) ac supply, 40 to 400 hz coils with short operating times (at vc): closing: opening: 60 ms 50 ms (c side); 20 ms (a side) coils for high operating rates ( 70 c [158 f]): 3600 operating cycles/hour 1800 for lc1f630 coils with low inrush consumption control circuit voltage vc average resistance at 20 c (68 f) 10% inductance of closed circuit rectifier coil inrush sealed catalog number c catalog number weight lb (kg) v ?? h for contactor lc1f400 48 4.03 43 0.22 dr5tf4v lx9fj917 2.14 (0.970) 110 25.7 246 1.3 dr5te4u lx9fj925 2.14 (0.970) 127 32.3 302 1.7 dr5te4u lx9fj926 2.14 (0.970) 220/230 99.5 919 5 dr5te4u lx9fj931 2.14 (0.970) 380/415 311 3011 15 dr5te4s lx9fj936 2.14 (0.970) 440 386 3690 19 dr5te4s lx9fj937 2.14 (0.970) 500 478 4380 23 dr5te4s lx9fj938 2.14 (0.970) specifications average consumption: - inrush: 500 va. - sealed: 23 va. heat dissipation: 11.4 to 13.9 w. for contactor lc1f500 48 3.73 30.7 0.18 dr5tf4v lx9fk917 2.38 (1.080) 110 24 204 1.1 dr5te4u lx9fk925 2.38 (1.080) 127 29.8 250 1.4 dr5te4u lx9fk926 2.38 (1.080) 220/230 89.9 770 4 dr5te4u lx9fk931 2.38 (1.080) 380/415 274 2075 12 dr5te4s lx9fk936 2.38 (1.080) 440 361 3060 16 dr5te4s lx9fk937 2.38 (1.080) 500 448 3750 19 dr5te4s lx9fk938 2.38 (1.080) specifications average consumption: - inrush: 550 va. - sealed: 31 va. heat dissipation: 15 to 18.3 w. for contactor lc1f630 48 2.81 20.8 0.17 dr5tf4v lx9fl917 3.20 (1.450) 110 13.5 114 0.77 dr5te4u lx9fl924 3.20 (1.450) 127 20.8 167 1.2 dr5te4u lx9fl926 3.20 (1.450) 220 52 425 2.9 dr5te4u lx9fl930 3.20 (1.450) 220/240 64.5 518 3.6 dr5te4u lx9fl931 3.20 (1.450) 380/400 163 1360 8.8 dr5te4s lx9fl935 3.20 (1.450) 415/440 204 1670 11 dr5te4s lx9fl936 3.20 (1.450) 500 312 2510 17 dr5te4s lx9fl938 3.20 (1.450) specifications average consumption: - inrush: 830 va. - sealed: 47 va. heat dissipation: 22.8 to 27.8 w. c rectifier to be ordered separately; weight of rectifier: 0.100 kg (0.22 lbs).
tesys? f-line contactors and starters selection - coils 209 01/04 ? 2001-2004 schneider electric all rights reserved lx9fk ??? lx9fj ??? lx9fl ??? contactors type lc1f coils for lc1f400 to f630 (specific applications) dc supply coils with short operating times (at vc): closing: opening: 60 ms 20 ms coils with high operating rates ( 70 c [158 f]): 3600 operating cycles/hour 1800 for lc1f630 coils with low inrush consumption control circuit voltage vc average resistance at 20 c (68 f) 10% inductance of closed circuit resistor coil inrush sealed quantity and catalog number c catalog number weight lb (kg) v ?? h for contactor lc1f400 48 5.11 99 0.27 1 x dr2sc0047 lx9fj918 2.14 (0.970) 110 32.3 632 1.7 1 x dr2sc0330 lx9fj926 2.14 (0.970) 125 39.4 760 2 1 x dr2sc0390 lx9fj927 2.14 (0.970) 220 123 2320 6.1 1 x dr2sc1200 lx9fj932 2.14 (0.970) 440/460 478 9080 23 1 x dr2sc4700 lx9fj938 2.14 (0.970) specifications average consumption: - inrush: 430 w. - sealed: 22 w. for contactor lc1f500 48 4.67 76.7 0.22 1 x dr2sc0039 lx9fk918 2.38 (1.080) 110 29.8 470 1.4 1 x dr2sc0220 lx9fk926 2.38 (1.080) 125 37.4 637 1.7 1 x dr2sc0330 lx9fk927 2.38 (1.080) 220 115 1935 5.1 1 x dr2sc1000 lx9fk932 2.38 (1.080) 440/460 448 7050 19 1 x dr2sc3300 lx9fk938 2.38 (1.080) specifications average consumption: - inrush: 470 w. - sealed: 29 w. for contactor lc1f630 48 3.43 52.9 0.20 2 x dr2sc0047 lx9fl918 3.20 (1.450) 110 17.2 272 0.98 2 x dr2sc0270 lx9fl925 3.20 (1.450) 125 20.8 333 1.2 2 x dr2sc0330 lx9fl926 3.20 (1.450) 220 64.5 1018 3.6 2 x dr2sc1000 lx9fl931 3.20 (1.450) 440/460 260 4010 14 2 x dr2sc3900 lx9fl937 3.20 (1.450) specifications average consumption: - inrush: 733 w. - sealed: 48 w. c resistors to be ordered separately, weight of resistor: 0.030 kg (0.06 lbs).
tesys? f-line contact ors and starters dimensions and mounting ? 2001-2004 schneider electric all rights reserved 210 01/04 dimensions and mounting contactors type lc1f dimensions dimensions shown in mm (mm x 0.0394 = inches ) lc1f115 to f330 x1 (mm) = minimum electrical clearance according to operating voltage and breaking capacity 200 to 500 v 600 to 1000 v lc1f115, lc1f150 10 15 lc1f185 10 15 lc1f225, lc1f265 10 15 lc1f330 10 15 q power terminal protection shroud (see page 198). f minimum distance required for coil removal. lc1- a b b1 b2 c f g g1 j j1 l m p q q1 s s1 y z f115 3p 163.5 162 137 265 171 131 106 80 106 120 107 147 37 29.5 60 20 26 44 13.5 4p 200.5 162 137 265 171 131 143 80 106 120 107 147 37 29.5 60 20 26 44 13.5 f150 3p 163.5 170 137 301 171 131 106 80 106 120 107 150 40 26 57.5 20 34 44 13.5 4p 200.5 170 137 301 171 131 143 80 106 120 107 150 40 26 55.5 20 34 44 13.5 f185 3p 168.5 174 137 305 181 130 111 80 106 120 113.5 154 40 29 59.5 20 34 44 13.5 4p 208.5 174 137 305 181 130 151 80 106 120 113.5 154 40 29 59.5 20 34 44 13.5 f225 3p 168.5 197 137 364 181 130 111 80 106 120 113.5 172 48 21 51.5 25 44.5 44 13.5 4p 208.5 197 137 364 181 130 151 80 106 120 113.5 172 48 17 47.5 25 44.5 44 13.5 f265 3p 201.5 203 145 375 213 147 142 96 106 120 141 178 48 39 66.5 25 44.5 38 21.5 4p 244.5 203 145 375 213 147 190 96 106 120 141 178 48 34 66.5 25 44.5 38 21.5 f330 3p 213 206 145 375 219 147 154.5 96 106 120 145 181 48 43 74 25 44.5 38 20.5 4p 261 206 145 375 219 147 202.5 96 106 120 145 181 48 43 74 25 44.5 38 20.5 f = minimum distance required for coil removal lc1f400 and f500 dimensions shown in mm mm x 0.0394 = inches x1 (mm) = minimum electrical clearance according to operating voltage and breaking capacity 200 to 500 v 600 to 1000 v lc1f400 15 20 lc1f500 15 20 q power terminal protection shroud (see page 198). f minimum distance required for coil removal. lc1- a b b2 c f g* g min g max g1 c g1 min g1 max jlmpqq1s f400 2p 213 206 375 219 119 80 66 102 170 156 192 19.5 145 181 48 69 96 25 3p 213 206 375 219 119 80 66 102 170 156 192 19.5 145 181 48 43 74 25 4p 261 206 375 219 119 80 66 150 170 156 240 67.5 145 181 48 43 74 25 f500 2p 233 238 400 232 141 80 66 120 170 156 210 39.5 146 208 55 76 102 30 3p 233 238 400 232 141 80 66 120 170 156 210 39.5 146 208 55 46 77 30 4p 288 238 400 232 141 140 66 175 230 156 265 34.5 146 208 55 46 77 30 c supplied. j j1 b1 = = g1 g z = = y 4x? 6.5 (1/4 inch mounting screws) l c = b = b 2 x1 x1 s1 q a ppq1 f m s f115 m6x25 f150 m8x25 f185 m8x25 f225 m10x35 f265 m10x35 f330 m10x35 g g1 23.5 j 120 = = 180 = = l c = b = b 2 209 56 x1 x1 q1 a p q p f m 44.5 s 6xm10x35 8x?8.5 (5/16 inch mounting screws)
tesys? f-line contactors and starters dimensions and mounting 211 01/04 ? 2001-2004 schneider electric all rights reserved contactors type lc1f dimensions dimensions shown in mm (mm x 0.0394 = inches ) lc1f630 and f800 a g supplied g min g max j1 q q1 x1 (mm) = minimum electrical clearance according to operating voltage and breaking capacity lc1f630 2p 309 180 100 195 68.5 102 127 voltage 200 to 500 v 690 to 1000 v 200 to 690 v 1000 v lc1f630 lc1f800 3p 309 180 100 195 68.5 60 89 lc1f630 20 30 ? ? lc1f630 4p 389 240 150 275 68.5 60 89 lc1f800 ?? 1020 lc1f780 x1 (mm) = min. electrical clearance according to operating voltage and breaking capacity voltage 200 to 500 v 690 to 1000 v x1 (mm) 30 35 c minimum distance required for coil removal. mounting holes of lc1f7804 mounting holes of lc1f780 180 = = j1 g 60.5 q1 a 80 80 q 264 181 64 40 6xm12x45 155 = 304 = 197 255 280 x1 464 72 x1 4x? 10.5 q power terminal protection shroud (see page 220). c minimum distance required for coil removal. 191 183 191 160 160 183 60 12xm12x45 26 = = 348 400 22 26 3p=702, 4p=862 x1 x1 = 280 = 434 165 255 102 240 90 190 240 180 127 127 8x10.5 (3/8 inch mounting screws) 132 240 90 240 180 127 127 6x10.5 (3/8 inch mounting screws)
tesys? f-line contact ors and starters dimensions and mounting ? 2001-2004 schneider electric all rights reserved 212 01/04 reversing contactors and changeover contactor pairs lc2f horizontally mounted dimensions shown in mm (mm x 0.0394 = inches ) for customer assembly, see pages 190 to 193. 2 x lc1f115 to lc1f330 2 x lc1f400, f500, f630, f800 x1 (mm) = minimum electrical clearance according to operational voltage and breaking capacity 200 to 500 v 660 to 1000 v 200 to 690 v 1000 v lc1f115, lc1f150 10 15 ? ? lc1f185 10 15 ? ? lc1f225, lc1f265 10 15 ? ? lc1f330 10 15 ? ? lc1f400 15 20 ? ? lc1f500 15 20 ? ? lc1f630 20 30 ? ? lc1f800 ??1020 2 x a b b1 c g g1 j j1 j2 j3 l p1 lc1f115 3p 345 162 137 171 ? 80 71 57 ? ? 107 77 4p 419 162 137 171 ? 80 108 75.5 ? ? 107 77 lc1f150 3p 345 170 137 171 ? 80 71 57 ? ? 107 71 4p 422 170 137 171 ? 80 111 75.5 ? ? 107 71 lc1f185 3p 357 174 137 181 ? 80 78 59.5 ? ? 113.5 78 4p 437 174 137 181 ? 80 118 79.5 ? ? 113.5 78 lc1f225 3p 357 197 137 181 ? 80 78 59.5 ? ? 113.5 62 4p 437 197 137 181 ? 80 118 79.5 ? ? 113.5 54 lc1f265 3p 425 203 145 213 ? 96 109 61.5 ? ? 141 100 4p 521 203 145 213 ? 96 157 85.5 ? ? 141 100 lc1f330 3p 447 206 145 219 ? 96 124 65.5 ? ? 145 107 4p 543 206 145 219 ? 96 172 89.5 ? ? 145 107 lc1f400 3p 446 206 209 219 80 170 157 64.5 67 19.5 145 107 4p 542 206 209 219 80 170 157 112.5 67 67.5 145 107 lc1f500 3p 485 238 209 232 80 170 156 84.5 66 39.5 146 112 4p 595 238 209 232 140 230 156 79.5 66 34.5 146 112 lc1f630 3p 636 304 280 255 180 ? 139 68.5 ? ? 155 137 4p 796 304 280 255 240 ? 139 88.5 ? ? 155 137 lc1f800 3p 636 304 280 255 180 ? 139 68,5 ? ? 155 137 c except lc1f630 and lc1f800 : 4 x ? 10.5. q except lc1f630 .and lc1f800 110/120 = = = g1 j1 3x?6. 5 = = g1 = j1 j 3x?6.5 a b p1 l c b b1 x1 x1 g g1 j3 120 = = 180 = = 8x?8.5 b g j1 j1 j2 j g1 j3 8x?8.5 p1 a
tesys? f-line contactors and starters dimensions and mounting 213 01/04 ? 2001-2004 schneider electric all rights reserved reversing contactors and changeover contactor pairs lc2f vertically mounted dimensions shown in mm (mm x 0.0394 = inches ) for customer assembly, with mechanical interlock (mi) la9f ??? . 2 x lc1 identical or different ratings ( lc1f115 to lc1f630 and lc1f800 ). see pages 190 to 193. assembly a assembly b assembly c assembly a (f800 in 3-pole only) assembly b (f800 in 3-pole only) mi g3h h1j1 mi g1g3g5h catalog # 3p4pminmaxminmax3p4p catalog # 3p4p3p4p3p4pminmax la9ff4f 0 0 200 310 80 190 137 155.5 la9fh4f 96 96 21 27 60 83 240 380 la9fg4f 3 4 210 300 90 180 139.5 159.5 la9fj4f 80 80 45 26 83 83 250 380 la9fg4g 0 0 220 310 100 190 139.5 159.5 la9fk4f 8014045268383270380 j2 j3 j4 la9fl4f 180 240 35 17 74 74 310 380 3p 4p 3p 4p 3p 4p la9fh4g 96 96 19 23 60 83 250 380 la9ff4f 137 155.5 48.5 67 48.5 67 la9fj4g 80 80 42 22 83 83 250 380 la9fg4f 137 155.5 53 73 54 69 la9fk4g 8014042228383270380 la9fg4g 139.5 159.5 53 73 53 73 la9fl4g 180 240 33 13 74 74 310 380 for customer assembly, mounting recommended on am1ec ??? uprights, 2 x lc1f780 h1 j1 j2 j4 min max 3p 4p 3p 4p 3p 4p la9fh4f 110 250 157.5 181.5 137 155.5 48.5 67 la9fj4f 80 210 144.5 192.5 137 155.5 48.5 67 la9fk4f 100 210 164.5 219.5 137 155.5 48.5 67 la9fl4f 140 210 248.5 328.5 137 155.5 48.5 67 la9fh4g 120 250 157.5 181.5 139.5 159.5 53 73 la9fj4g 90 220 144.5 192.5 139.5 159.5 53 73 la9fk4g 110 220 164.5 219.5 139.5 159.5 53 73 la9fl4g 150 220 248.5 328.5 139.5 159.5 53 73 assembly c (f800 in 3-pole only) mi g1 g2 g3 g4 g5 catalog # 3p4p3p4p3p4p3p4p3p4p la9fh4h 96 96 96 96 0 0 60 83 60 83 la9fj4h 80 80 96 96 23 0 60 83 83 83 la9fk4h 80 140 96 96 23 0 60 83 83 83 la9fl4h 180 240 96 96 14 9 p 60 83 74 74 la9fj4j 80 80 80 80 0 0 83 83 83 83 la9fk4j 8014080800 0 83838383 la9fl4j 180 240 80 80 9 p 9 p 83 83 74 74 la9fk4k 80 140 80 140 0 0 83 83 83 83 la9fl4k 180 240 80 140 9 p 9 p 83 83 74 74 la9fl4l 180 240 180 240 0 0 74 74 74 74 hh1j1j2 min max min max 3p 4p 3p 4p la9fh4h 250 380 130 260 157.5 181.5 157.5 181.5 la9fj4h 260 380 110 230 144.5 192.5 157.5 181.5 la9fk4h 280 380 130 230 164.5 219.5 157.5 181.5 la9fl4h 330 380 170 220 248.5 328.5 157.5 181.5 la9fj4j 260 380 60 200 144.5 192.5 144.5 192.5 la9fk4j 280 380 100 200 164.5 219.5 144.5 192.5 la9fl4j 325 380 140 195 248.5 329.5 144.5 192.5 la9fk4k 300 380 120 200 164.5 329.5 164.5 219.5 la9fl4k 345 380 160 195 248.5 328.5 164.5 219.5 la9fl4l 380 380 200 200 248.5 328.5 248.5 328.5 p in this case, g4 is greater than g5 120 120 h1 80 j4 j2 j1 g3 == == ( q ) 80 j3 h = = f330 f265 180 h1 120 } f400 f500 f630 f800 180 } g1 g5 12. 5 j1 g3 80 j4 = = ? h 9 j2 f330 f265 h1 120 } f400 f500 f630 180 } f330 f265 120 } f400 f500 f630 180 } j1 g3 ? g2 g4 j2 12,5 9 = = ? g1 g5 12.5 h c mechanical interlock shaft. q 4 x ?6.5 for lc1f115 to lc1f225 f for assembly of contactors of different ratings only. p mechanical interlock guide bracket. t 4 x ?8.5 for lc1f400, lc1f500 or 4 x ?10.5 for lc1f630, lc1f800. k 4 x ?6.5 for lc1f265. 250 x1 = 180 = 180 420 1034 191 160 160 191 702 (lc f780), 862 (lc1f7804) x1 x1 and mounting holes, see page 211.
tesys? f-line contact ors and starters dimensions and mounting ? 2001-2004 schneider electric all rights reserved 214 01/04 contactors type lc1f mounting dimensions shown in mm (mm x 0.0394 = inches ) lc1f115 to lc1f330 on panel on pre-slotted mounting plate am1pa , am1pb , am1pc on rails dz5mb on 120 mm center lc1f115, lc1f150 lc1f185, lc1f225 lc1 f265 lc1 f330 lc1f115, lc1f150 lc1f185, lc1f225 lc1 f265 lc1 f330 lc1f115, lc1f150 lc1f185, lc1f225 lc1 f265 lc1 f330 c q 3p 171 181 213 219 c q 3p 171 181 213 219 c q 3p 171 181 213 219 4p 171 181 213 219 4p 171 181 213 219 4p 171 181 213 219 g 3p 80 80 96 96 g 3p 80 80 96 96 g 3p 80 80 96 96 4p 80 80 96 96 4p 80 80 96 96 4p 80 80 96 96 j 3p 26.5 29 44.5 44.5 4p 45 49 68.5 68.5 j1 3p 57 59.5 61.5 61.5 4p 75.5 79.5 85.5 85.5 c power terminal protection shroud (see page 198) q see x1, minimum electrical clearance on pages 210 and 211. lc1f lc1f115 to lc1f330 lc1f400 to lc1f800 on 2 notched rails am1-ec ??? lc1f115, lc1f150 lc1f185, lc1f225 lc1f265 lc1f330 lc1f400 lc1f500 lc1f630 lc1f780 lc1f800 c 3p 165 p 176 207 213 219 232 255 255 255 4p 165 p 176 207 213 219 232 255 255 ? g (m6) 3p80809696????? 4p80809696????? g1 (? 8.5) 3p????8080??? 4p????80140??? g2 (? 10.5) 3p??????180see page 211 4p??????2401/129? f af1cd ??? and af1va ???. k this am1ec200 upright is required when g2 or g3 is greater than 700 mm. p add 6 mm with timer block on lc1f . c af1ea6 110 g 3x?6.5 c j g = j1 = 110 = = dz5mf5 c g 110 120 15 c 25 120 ?10.5 am1ec200 af1cd081 + af1vc820 am1ec200 af1cd061+ af1va618 af1-cd061 af1-va618 m6 la9-f100 af1cd101+ af1vc10 af1cd081+ af1vc820 ?8.5 m6 am1ec200 110 35 180 g = = g af1va618 m6 g1 g2 g3
tesys? f-line contactors and starters dimensions and mounting 215 01/04 ? 2001-2004 schneider electric all rights reserved contactors type lc1f cabling accessories dimensions shown in mm (mm x 0.0394 = inches ) paralleling links (set of 4) la9ff, fg, fh602 la9fk, la9fl602 la9ff602 la9fg602 la9fh602 la9fk602 la9fl602 a 25 30 40 50 60 b 45 55 60 85 100 b1 30 35 40 55 65 c 4581010 g ???2226 h 37.5 45 52.5 70 85 h1 12.5 15 15 14 17 h2 ???2226 ?1 6.5 9 11 11 13 ?2 11 11 13 11 14 bars for 3-pole star connection la9f ? 601 la9ff601 la9fg601 la9fh601 la9fk601 la9fl601 a 89 100 121 140 200 b 15 20 20 30 40 c 33558 ? 6.5 x 8.5 8.5 x 10.5 10.5 x 13 11 13 brackets la9f ? 981 (set of 3) for back connection la9ff981 la9fg981 la9fj981 la9fk981 la9fl981 a 15 20 25 30 40 b 18 23 29 35 48 b1 33458 c 42 45 55 52 86 g 24 26 32.5 26 45 h 10.5 13 16.5 20 28 ? 6.5 9 11 11 13 brackets la9f ? 979 (set of 3) for side connection la9ff979 la9fg979 la9fj979 la9fk979 la9fl979 a 15 20 25 30 40 b 54 58 63.5 68 117 b1 556610 c 80 92 120 120 130 g 24 28 37 37 37.5 g1 20 22 29 29 35 h 36 39 41 42 76 ? 6.5 9 11 11 13 wide range brackets la9f ? 980 (set of 3) la9ff980 la9fg980 la9fj980 la9fk980 la9fl980 a 35 40 50 60 100 b 70.5 82.5 98.5 114 154 b1 40 45 55 65 85 c 29 29 33 33 43 c1 335510 g 18 20 25 29 53 h 18 20 22 26 40 h1 10 12 14 17 20 h2 60.5 72.5 84.5 97 132 ? 6.5 9 11 11 13 c ?7 x 10 ?9 x 12 ?11 x 14 ?12.5 x 15 ?12.5 x 15 a = 1 2 b = h1 b1 h c a = 1 2 b = h1 b1 h c g h2 b = = c a c g b1 a h b b1 h b c g1 g g a h1 a =g = c c1 b h b1 h2 ?
tesys? f-line contact ors and starters schematics ? 2001-2004 schneider electric all rights reserved 216 01/04 schematics contactors type lc1f schematics 2-, 3-, and 4-pole contactors lc1f115 to lc1f630 (coil lx1f ac) lc1f115 to lc1f630 (coil lx4f dc) lc1f115 to lc1f265 (coil lx9f ac) lc1f800 (coil lx8f ac/dc) lc1f780, 3- and 4-poles ac or dc front-mounting contact blocks instantaneous auxiliary contacts 1 n.o. la1dn10 c 1 n.c. la1dn01 c 1 n.o. + 1 n.c. la1dn11 2 n.o. la1dn20 2 n.c. la1dn02 2 n.o. + 2 n.c. la1dn22 1 n.o. + 3 n.c. la1dn13 4 n.o. la1dn40 4 n.c. la1dn04 2 n.o. + 2 n.c. including 1 n.o. + 1 n.c. make before break la1dc22 3 n.o. + 1 n.c. la1dn31 c items in brackets are for blocks mounted on right-hand side of contactor. front-mounting contact blocks instantaneous auxiliary contacts with terminal referencing confo rming to standard en 50012 (r eferences: pages 218 and 219) 1 n.o. + 1 n.c. la1dn11p 1 n.o. + 1 n.c. la1dn11g 1 n.o. + 1 n.c. la1dn11m 2 n.o. + 2 n.c. la1dn22p 2 n.o. + 2 n.c. la1dn22g 2 n.o. + 2 n.c. la1dn22m front-mounting contact blocks dust and damp protected inst antaneous auxiliary contacts 2 n.o. (24-50 v) la1dx20 2 n.o. (5-24 v) la1dy20 2 n.o. protected (24-50 v) + 2 n.o. standard la1dz40 2 n.o. protected (24-50 v) + 1 n.o. + 1 n.c. standard la1dz31 front-mounting contact blocks time delay auxiliary contacts ondelay 1 n.o. + 1 n.c. la2dt ? off delay 1 n.o. + 1 n.c. la3dr ? on delay n.c. contact with n.o. break before make contact la2ds ? interface module standard ac coils la4fwb lx1ff,fg, fj to lx1fl lx1fh0422 to lx1fh3802 lx1fh0202 to lx1fh0362 lx1fh4402 to lx1fh10002 lx8f8 ? w (ac / dc) lx1fx rectifier supplied and attached to the contactor special ac coils dc coils lx9ff, lx9fg lx9fh ??? 2 lx9fj, lx9fk, lx9fl lx4ff, fg, fh, fj, fk, fl, fx c a2 03 04 1/l 1 t 1/2 3/l 2 t 2/4 5/l 3 t 3/6 7/l 4 t 4/8 a1 a1 a2 1/l 1 t 1/2 3/l 2 t 2/4 5/l 3 t 3/6 7/l 4 t 4/8 1/l 1 t 1/2 3/l 2 t 2/4 5/l 3 t 3/6 7/l 4 t 4/8 a2 a1 43/no 44 (94) (93) 62 61/nc 53/no 54 (92) (91) 42 41/nc 53/no 54 63/no 64 62 61/nc 51/nc 52 72 71/nc 62 51/nc 53/no 54 83/no 84 53/no 54 63/no 64 73/no 74 83/no 84 72 71/nc 62 61/nc 82 81/nc 52 51/nc 76 75/nc 62 61/nc 53/no 54 87/no 88 62 61/nc 53/no 54 84 83/no 73/no 74 72 71/nc 62 61/nc 53/no 54 82 81/nc 22 21/nc 13/no 14 32 31/nc 43/no 44 22 21/nc 33/no 34 22 21/nc 32 31/nc 13/no 14 43/no 44 32 31/nc 42 41/nc 63/no 64 53/no 54 22 21/nc 32 31/nc 53/no 54 43/no 44 62 61/nc 53/no 54 83/no 84 73/no 74 53/no 54 83/no 84 63/no 64 73/no 74 53/no 54 63/no 64 53/no 54 63/no 64 55/nc 56 67/no 68 66 65/nc 57/no 58 67/no 68 55/nc 56 b2 a1 ? e2 e1 + k a1 a2 a2 a1 a2 a1 03 a2 a1 a2 a1 a2 a1 a2 a1 + ? a2 a1 a2 a1 b2 b1 a2 a1 a1 b1 a2/b2 a2 a1 + ? 01 a2 a1 a2 a1 f breaking on ac side drop-out time 50 ms q breaking on dc side drop-out time 20 ms c 2 coils in series
tesys? f-line contactors and starters schematics 217 01/04 ? 2001-2004 schneider electric all rights reserved reversing contactors and changeover contactors reversing contactors for motor control, horizontally mounted reversing contactors for motor control, vertically mounted 2 x lc1f 2 x lc1f dashed lines indicate suggested customer wiring to electrically interlock coils using quantity of 2 la1dn ? 1 auxiliary contact blocks. changeover contactor pairs for distribution, horizontally mounted changeover cont actor pairs for distribution, vertically mounte d 2 x lc1f 2 x lc1f electrical interlocking of reversers with: mechanical interlock la9f ??? without integrated electrical contacts note: must use quantity of 2 la1dn ? 1 auxiliary contact blocks to provide electrical interlocking of coils. see diagram with dashed lines above. a1 a2 1 2 3 4 5 6 l1 l2 l3 1 2 3 4 5 6 u v w a1 a2 a1 a2 e1 1 2 3 4 1/l1 1/l2 1 2 3 4 5 6 1/l3 5 6 a1 a2 e1 l3 l2 l1 a1 a2 1 2 3 4 5 6 1n 1/l3 1/l2 1 2 3 4 7 8 l1 l2 n a1 a2 5 6 l3 7 8 1/l1 2/l1 2/l2 2/l3 2n a1 a2 e1 1 2 3 4 7 8 1/l1 1/l2 1n 1 2 3 4 7 8 2/l1 2/l2 2n 5 6 1/l3 5 6 2/l3 a1 a2 e1 l3 l2 l1 n a1 a2 e km2 e km1 a1 a2 e km1 e km2
tesys? f-line contact ors and starters lr9f solid state overload relays - characteristics ? 2001-2004 schneider electric all rights reserved 218 08/04 lr9f solid state overload relays - characteristics introduction the lr9f solid state overload relay provides the accu rate, repeatable protection of a solid state device, while still maintaining the ease of installation of a traditional overload relay. the lr9f provides protection against:  motor overload  failure or phase unbalance of 30% or greater  prolonged starting times  locked rotor conditions the lr9f overload relays have 8 current ranges, spanning 30 amps up to 630 amps. they are available in class 10 trip or class 20 trip models. the device is manually reset via a clearly labeled button on the front face. a separate attach ment is available for remote reset or test tripping of the relay. all units incorporate both a normally open and normally closed contact for control circuit wiring. the lr9f is designed to directly mount on the load si de of a lc1f contactor, minimizing space and wiring time. lugs for the lr9f are ordered separately (see page 220 for selection). for lr9f relays up to 185 amps, an interposing touch-safe terminal block may be ordered in place of lugs, making power wiring even easier. lr9f tripping curve average operating times depending on multiples of the current setting class 10 class 20 1. trip current adjustment dial 2. stop button 3. test button 4. reset button 5. trip indicator 6. clip-on legend 7. transparent cover with sealing provisions lr9 f5369 electronic motor protection ir(a) 150 90 125 105 stop tripped test reset no 97 98 nc 95 96 1 3 2 4 6 7 5 1 1000 100 10 1 0 1,12 2 3 4 5 6 7 8 9 10 11 12 1 2 1 cold state curve 2 hot state curve tripping time in seconds x times current setting (ir) 1 0 1,12 2 3 4 5 6 7 8 9 1000 100 10 1 1 2 x times current setting (ir) tripping time in seconds
tesys? f-line contactors and starters lr9f solid state overload relays - characteristics 219 01/04 ? 2001-2004 schneider electric all rights reserved environment power circuit characteristics auxiliary contact characteristics conforming to standards meets the essential requirements of lv & emc directives. iec 60947-1, 60947-4-1, 255-8, and vde 0660en 60947-1. 60947-4-1 approvals ul508; csa 22-2, no.14; ptb pending degree of protection conforming to vde 0106 ip 20 - protection against direct finger contact with la9f103 insulated terminal blocks or la9f7/la7f7 shrouds protective treatment standard version "th" ambient air temperature around the device (conforming to iec 60255-8) storage ? 40 to + 85 c ( ? 40 to +185 f) normal operation ? 20 to + 55 c (-4 to +131 f) maximum operating altitude without derating m 2000 operating positions without derating in relation to normal vertical mounting plane all positions shock resistance permissible acceleration conforming to iec 60068-2-7 13 g - 11 ms vibration resistance permissible acceleration conforming to iec 60068-2-6 2 g dielectric strength at 50 hz conforming to iec 60255-5 kv 6 impulse withstand voltage conforming to iec 60801-5 kv 4 resistance to electrostatic discharges conforming to iec 60801-2 kv 8 (in air) 6 (in indirect mode) resistance to radio-frequency conducted di sturbances conforming to iec 60801-3 and nf c 46-022 v/m 10 resistance to fast transient currents conforming to iec 60801-4 kv 2 electromagnetic compatibility en50081-1 & 2, en50082-2 meets test requirements relay type lr9f f5 ? 57 f5 ? 63 f5 ? 67 f5 ? 69 f5 ? 71 f7 ? 75 f7 ? 79 f7 ? 81 rated insulation voltage (vi) conforming to iec 60947-4 v 1000 rated operational voltage (ve) conforming to vde 0110 gr c v 1000 rated impulse withstand voltage (vimp) conforming to iec 60947-1 kv 8 rated operational current (ie) a 30 to 630 frequency limits of the operating current hz 50/60 power circuit connections width of terminal lug mm (in) 20 (0.78) 25 (0.98) 25 (0.98) 30 (1.18) 40 (1.57) 40 (1.57) clamping screw m6 m8 m10 m10 m10 m12 tightening torque ib ? in 90 160 310 310 310 515 n ? m101835353558 rated thermal current a5 control circuit connections stranded cable without cable end minimum maximum 1 conductor mm 2 1 x 0.75 1 x 4.0 2 conductors 2 x 1.0 2 x 2.5 1 conductor awg 1 x 18 2 x 12 2 conductors 2 x 16 2 x 14 stranded cable with cable end 1 conductor mm 2 1 x 0.75 1 x 2.5 2 conductors 2 x 1.0 2 x 1.5 solid cable 1 conductor mm 2 1 x 0.75 1 x 2.5 2 conductors 2 x 1.0 2 x 1.0 tightening torque ib ? in 11 n ? m1.2 maximum sealed consumption of coils on controlled contactors ac control v 2448110220380600 va 100 200 400 600 600 600 dc control v 2448110220440? w 100 100 50 45 25 ? ei64353 nkcr lr43364 3211 03
tesys? f-line contact ors and starters lr9f solid state overload relays - selection ? 2001-2004 schneider electric all rights reserved 220 08/04 lr9f solid state overload relays - selection three-phase overload relays c lug kits lugs can be ordered either individually or in sets of six. in some cases the lr9f overload relay mounted directly on the bottom of lc1f contactor will require a different size lug than the contactor itself. refer to the table below to select the appropriate size lug fo r your choice of contactor and overload. if all 6 lugs (three for line side of contactor, three for load side of overload relay) are the same, square d offers a pre-packaged set of six lugs. if the two sizes are different, order 3 of each size lug. mounting hardware (screws, washers, nuts) are provided with the co ntactors and overload relays, not with the lugs. a customer to obtain from local supplier. insulated terminal blocks for contactors lc1f115, lc1f150, and lc1f185, an available touch-safe terminal block may be used in place of lugs for power connections current setting range amps for direct mounting to contactor lc1 ???? /cr1f ???? class 10 trip q catalog number class 20 trip q catalog number 30 to 50 f115 to f185 lr9f5357 lr9f5557 48 to 80 f115 to f185 lr9f5363 lr9f5563 60 to 100 f115 to f185 lr9f5367 lr9f5567 90 to 150 f115 to f185 lr9f5369 lr9f5569 132 to 220 f185 f , f265 lr9f5371 lr9f5571 200 to 330 f265 to f500 lr9f7375 lr9f7575 300 to 500 f265 to f500 lr9f7379 lr9f7579 380 to 630 f400 to f630 lr9f7381 lr9f7581 c when mounting overload relays lr9f5 ? 57 to lr9f5 ? 71 directly beneath the contactor it is recommended that the relays be additionally supported by a mounting plate. for sizes lr9f5 ? 75 to lr9f7 ? 81 use of the supporting mounting plate is mandatory. see page 221 for selection table. q iec standard 60947-4 specifies the following trip times when the overload relay senses 7.2 times the setting current: class 10: between 4 and 10 seconds class 20: between 6 and 20 seconds f interconnection kit la7f407 is required to mount an lr9f ? 71 to an lcif185 . overload relay directly mounted to contactor lc1 ???? cable size awg range lug catalog number line side (of co ntactor) load side (of overload) line side (of contactor) load side (of overload) lr9f5 ? 57 to f5 ? 69 f115 14 to 2/0 6 to 3/0 3 ea. dz2ff1 3 ea. dz2fg1 lr9f5 ? 57 to f5 ? 71 f150 or f185 6 to 3/0 1 ea. dz2fg6 lr9f5 ? 71 f265 6 to 300 mcm 1 ea. dz2fh6 lr9f7 ? 75 to f7 ? 79 f265 or f330 6 to 300 mcm 4 to 500 mcm 3 ea. dz2fh1 a lr9f7 ? 75 to f7 ? 81 f400 4 to 500 mcm 4 to 500 mcm 3 ea. dz2fj1 a lr9f7 ? 75 to f7 ? 81 f500 2 x 2 to 600 mcm 4 to 500 mcm 3 ea. dz2fk1 a lr9f7 ? 81 f630 3 x 2 to 600 mcm 4 to 500 mcm dz2fl1 dz2fl2 dz2fl3 a insulated terminal block cable size awg range suitable for contactor lc1 ???? /cr1 ???? suitable for overload relay lr9 ????? la9f103 #6 to 300 mcm f115, f150, f185 5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 lr9f53 ??? lr9f73 ??? lr9f73 ??? dz2f ??
tesys? f-line contactors and starters lr9f solid state overload relays - accessories 221 01/04 ? 2001-2004 schneider electric all rights reserved lr9f solid state overload relays - accessories lr9f solid state overload relays - accessories mounting plate for overload relay provides overload relay support when mounted directly to f-line contactor for use with relays: catalog number lr9f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 and f5 ? 71 la7f901 lr9f7 ? 75, f7 ? 79 and f7 ? 81 la7f902 power terminal protection shrouds, single-pole these clear plastic protection shrouds are an effective means to meet international touch-safe requirements for power terminals. they are designed to be used with power cables that have been bolted to the terminal. note: the protection shrouds do no t attach to contactors or overl oad relays utilizing dz2f lug kits. for use with relays catalog number lr9f5 ? 57 la9f701 lr9f5 ? 63, f5 ? 67, f5 ? 69 la9f702 lr9f5 ? 71 la9f705 lr9f7 ? 75, f7 ? 79, f7 ? 81 la9f703 power terminal protection shrouds, 3-poles for use with relays catalog number lr9f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 la7f701 lr9f5 ? 71 la7f702 lr9f7 ? 75, f7 ? 79, f7 ? 81 la7f703 connection accessories required (for mounting overload relays beneath reversing contactors) application set of 3 bars catalog number for relays for contactor lr9f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 lc1f115 la7f401 lr9f5 ? 57, f5 ? 63 lc1f150 and f185 la7f402 lr9f5 ? 71 lc1f185 la7f407 lr9f5 ? 71 lc1f265 la7f403 lr9f7 ? 75, f7 ? 79 lc1f265 to f400 la7f404 lr9f7 ? 81 lc1f400 la7f404 lr9f7 ? 75, f7 ? 79, f7 ? 81 lc1f500 la7f405 lr9f7 ? 81 lc1f630 la7f406 marking accessories description sold in units of: catalog number marker holder, snap-in 100 la7d903 control accessories description sold in lots of catalog number remote electrical reset snap-on module c 1 la7d03 ? q remote reset function control by flexible cable (length = 0.5 m / 0.02") 1 la7d305 locking device for ?stop? button 10 la7d901 remote stop and/or reset function control adaptor for door mounted operator 1 la7d1020 rod (snap-off end to obtain required length, between 17 and 120 mm) 1 za2bz13 operating head for spring return pushbutton 1 za2ba8602 standard control circuit voltages volts 12 24 48 96 110 220/230 380/400 415/440 ac 50/60 hz ? b e ? f m q n consumption, inrush and sealed: < 100 va dc j beddfm? ? consumption, inrush and sealed: < 100 w c part number to be completed by adding coil voltage code. q the time for which the coil of remote electrical reset device la7d03 can remain energized depends on its rest time: 1 s pulse duration with 9 s rest time; 5 s pulse duration with 30 s rest time; 10 s pulse duration with 90 s rest time: maximum pulse duration of 20 s with rest time of 300 s. minimum impulse time: 200 ms. la7f90 ? la9f70 ? la7f70 ?
tesys? f-line contact ors and starters lr9f solid state overload relays - dimensions ? 2001-2004 schneider electric all rights reserved 222 01/04 lr9f solid state overload relays - dimensions ccc common side view lr9f5 ? 71 lr9f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 common side view lr9f7 ? 75, f7 ? 79, f7 ? 81 lr9f7 ? 81 (for mounting beneath lc1f630) p1 p2 lr9f7 ? 75 48 48 lr9f7 ? 79, f7 ? 81 55 55 c terminal shroud la9f70 ?. 120mm 60mm 50mm 50mm 71mm 5.5mm 56.8mm 123.5mm = 4.8" 3mm 46.8mm 3mm 44.8mm 76mm 25mm 48mm 101mm 115mm ? 11 4x?5.5 2.2" 1.8" 1.7 " 1.8" 48mm 1.8" .098" 4.5" 1.9" 1.9" 4.7" 1.2" 2.3" 2.7" .011" .011" 3.9" 2.9" q 6.5 x 13.5 for lr9f5 ? 57 and 8.5 x 13.5 for lr9f5 ? 63 , f5 ? 67 , f5 ? 69 . 76mm 40mm 40mm 96mm 50mm 50mm 60mm 71mm 5.5mm 4x ? 5.5 115mm 20mm 3.7" 3" 1.9" 1.9" 1.5" 1.5" .21" 2.3" 2.8" 4.5" .78" 108.8mm 14mm 30mm p2 p1 151.3mm ?11 51.5mm 51.5mm 66mm 66mm 4x? 5.5 70mm 22.1mm 6mm 82mm 136.8mm 25mm 42.2mm 127.6mm 6mm 44.8mm 5" 4.2" 1.6" .2" 1.7" 2.7" .8" .5" 1.1" .2" 3.2" 5.3" 2" 2" 2.5" 2.5" 5.9" c terminal shroud la9f70 ?. 188.8mm 20mm 200mm 80mm 80mm 193mm 228.8mm 76.5mm 76.5mm 62.1mm ?13 40mm 40mm 7.8" 3.1" 3.1" 1.5" 1.5" 3" 3" 7.5" 9" 7.4" 2.4" .7"
tesys? f-line contactors and starters lr9f solid state overload relays - mounting 223 01/04 ? 2001-2004 schneider electric all rights reserved lr9f solid state overload relays - mounting direct mounting beneath contactor lc1f lc1 contactors with lr9 relays b h1 h2 h3 f115 f5 k 57, f5 k 63, f5 k 67, f5 k 69 240 30 76 120 f150 f5 k 57, f5 k 63, f5 k 67, f5 k 69 246 30 76 120 f185 f5 k 57, f5 k 63, f5 k 67, f5 k 69 250 30 76 120 f225 f5 k 71 273 40 76 120 f7 k 75, f7 k 79 308 50 108.8 120 f265 f5 k 71 279 40 76 120 f7 k 75, f7 k 79 314 60 108.8 120 f330 f7 k 75, f7 k 79 317 60 108.8 120 f400 f7 k 75, f7 k 79, f7 k 81 317 60 108.8 180 f500 f7 k 75, f7 k 79, f7 k 81 346 70 108.8 180 f630 f7 k 81 510 110 108.8 180 direct mounting beneath reversing contactors or star-delta contactors lc1 contactors with lr9 relays b h4 h2 h3 f115 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 279 60 76 120 f150 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 283 60 76 120 f185 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 285 60 76 120 f225 f5 ? 71 319 80 76 120 f7 ? 75, f7 ? 79 360 100 108.8 120 f265 f5 ? 71 332 90 76 120 f7 ? 75, f7 ? 79 363 100 108.8 120 f330 f7 ? 75, f7 ? 79 364 100 108.8 120 f400 f7 ? 75, f7 ? 79, f7 ? 81 364 100 108.8 180 f500 f7 ? 75, f7 ? 79, f7 ? 81 390 110 108.8 180 f630 f7 ? 81 509 120 108.8 180 c relay mounting plate, see page 221. h2 b h3 h1 145 (la7f901) 180 (la7f902) 50 (la7f901) 57 (la7f902) la7f90 ? overload relay mounting plate dimensions shown in mm mm x.0394 = in la7f40 ? bus bar h2 b h4 h3
tesys? f-line contact ors and starters lr9f solid state overload relays - wiring diagrams ? 2001-2004 schneider electric all rights reserved 224 01/04 lr9f solid state overload relays - wiring diagrams wiring diagram lr9f setting the special functions of lr9f thermal overload relays setting the relay 2: stop function   the stop function is obtained by pressing the red ?stop? button (2) .  pressing the ?stop? button actuates the n.c. contact, but does not affect the n.o. contact.  the ?stop? button can be locked by installing a ?u? clip (catalog number la7d901 ). 3: test function  lift the transparent cover (7) to gain access to the settings and controls.  adjust relay by turning dial (1), which is graduated directly in amperes.  the setting can be locked by sealing of the cover (7) .  the test function is activated by pressing the red ?test? button (3) with a screwdriver.  pressing the ?test? button simulates tripping of the relay and actuates both n.o. and n.c. contacts, and also actuates the trip indicator (5) . 95 97 6/t3 4/t2 2/t1 96 98 5/l3 3/l2 1/l1 m a 13 14 km km1 1 2 3 4 5 6 m 3 l1 l2 l3 km a1 a2 112 % n manual reset specialized circuit test reset overload tripped setting current lr9 f5369 protection lectronique moteur electronic motor protection ir(a) 150 90 125 105 stop tripped test reset no 97 98 nc 95 96 1 3 2 4 6 7 5 test re tripped stop test reset tripped stop test trip indicator
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? characteristics 225 01/04 ? 2001-2004 schneider electric all rights reserved magnetic latching contactors - characteristics magnetic latching contactors of both block and bar mounted types include a special electromagnet which enables them to remain in the ?on? po sition when the coil is no longer energized. the special properties of magnetic latching contac tors make them suitable for a large number of applications: properties  retention of the sequence memory in automatic cont rol equipment in the event of a control circuit failure.  energy saving, since the source of supply to th e coil does not need to supply current when the contactor is latched in the closed state.  change of state from ?closed? to ?o pen? by current signal through the coil.  unaffected by line interference.  utilization of contactors beyond their breakin g capacity as operations are performed off load.  contactors are silent in the latched position. applications  refineries, power stations, excitation circuits.  contactors remaining in the closed state for long periods. example: refineries, power supplies, low voltage distribution.  selective opening control.  no unwanted opening and closing of the main power poles.  current carrying at voltages up to 1000 volts. operation of the electromagnet cr1f contactors cr1f magnetic latching contactors include a double coil with 3 terminals comprising a latching winding and an unlatching winding. the 2 windings have a common point which can necessitate special wiring precautions when the latchi ng supply is separate from the unlatching supply. the power supplies may be ac or dc. for dc operat ion, the polarities indica ted must be complied with. operating precautions:  the 2 windings must not be energized simultaneously,  a winding must not be energized continuously,  supply to the coils must be via momentary contacts. manual opening: if the control voltage is not pr esent, the contactor can be unlatched manually. cr1b contactors cr1b magnetic latching contactors included a single coil, supplied with dc or ac through a rectifier. latching is obtained by direct supply of the coil in one direction of current flow. unlatching is obtained by a reverse current, adjusted by resistors. lc1d contactors for applications using smaller contactor sizes than th ose described in the following pages, it is possible to obtain the same function by the addition of a mechanical latching block type la6dk , which can be mounted on lc1d contactors (information on d-line contactors starts on page 79).
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? characteristics ? 2001-2004 schneider electric all rights reserved 226 01/04 type cr1f150 cr1f185 cr1f265 cr1f400 cr1f500 cr1f630 cr1bl cr1bm cr1bp cr1br environment rated insulation voltage (vi) conforming to iec 60947-4-1, bs 775, 60947-4 v 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 conforming to vde 0110 grc v 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 conforming to standards meets the essential requirements of the lv & emc directives iec 60947-4, nfc 63-110, vde 0660, bs 5424, jem 1038 approvals e164862 nldx p lr43364 3211 04 p ase, csa, ul, bv, gl, lros, ussr, norsk veritas, rina degree of protection conforming to iec 60529 ip 20 front face with shrouds la9f conforming to vde 0106 protection against direct finger contact with shrouds la9f protective treatment standard version ?th? ?tc? special version ? ?th? ambient air temperature around the device storage -60 to +80 c (-76 to +176 f) for operation at vc -15 to +70 c (5 to +158 f) -15 to +60c (5 to +158f) maximum opera ting altitude without derating 3000m (9800 ft.) operating positions without derating 5 in relation to normal vertical mounting position 30 in relation to normal vertical mounting position pole characteristics number of poles 3 or 4 3 or 4 3 or 4 3 or 4 3 or 4 3 or 4 1, 2, 3 or 4 1, 2, 3 or 4 1, 2, 3 or 4 1, 2, 3 or 4 rated operational current (ie) (ve 440 v) ac-3, q 40 c (104 f) a 150 185 265 400 500 630 750 1000 1500 1800 ac-1, q 40 c (104 f) a 250 275 350 500 700 1000 800 1250 2000 2750 ac-4, q 40 c (104 f) a 138 170 245 370 460 560 700 800 1250 1500 rated operational current (ve) up to v 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 frequency limits (sine wave) of the operational current hz 25 to 200 25 to 200 25 to 200 25 to 200 25 to 200 25 to 200 50 to 60 50 to 60 50 to 60 50 to 60 rated maki ng capacity i rms a 1700 2100 2940 4500 5500 6740 10 000 10 000 15 000 18 000 rated breaki ng capacity i rms 220 to 440 v a 1500 1800 2450 4000 5000 6300 10 000 10 000 15 000 18 000 500 v a 1200 1600 2200 3500 4500 5400 9000 9000 12 000 15 000 660/690 v a 1100 1200 1700 3000 3560 4600 8000 8000 9000 11 000 1000 v a 450 600 800 1200 2500 3200 4000 4000 5000 6000 permissible short time rating from cold state, no current flowing for preceding 60 minutes at q 40 c (104 f) for 1 s a 1200 1500 2200 3600 4200 5050 9600 9600 12 000 15 000 for 5 s a 1200 1500 2200 3600 4200 5050 9600 9600 12 000 15 000 for 10 s a 1200 1500 2200 3600 4200 5050 7000 8000 9600 12 000 for 30 s a 700 920 1230 2400 3200 4400 4800 5200 6400 8000 for 1 min a 600 740 950 1700 2400 3400 3500 3800 5200 6300 for 3 min a 450 500 620 1200 1500 2200 2100 2400 3600 4400 for 10 min a 350 400 480 1000 1200 1600 1200 1800 2800 3600 short-circuit protection by fuses q 440 v k motor circuit ac-3 (type am) a 160 200 315 400 500 630 800 1200 800 x 2 f 1000 x 2 f ac-1 circuit (type gi, bs 88) a 250 315 400 500 800 1000 800 1200 1000 x 2 f 1200 x 2 f average impeda nce per pole at ith and 50 hz m ? 0.45 0.36 0.32 0.28 0.18 0.12 0.18 0.18 0.13 0.09 power dissipated per pole for the above operational currents ac-3 w 6 12 22 45 45 48 88 180 290 360 ac-1 w1826397088120115280520680 cabling cable size (min - max) awg #6 to 3/0 #6 to 3/0 #6 to 300mcm #4 to 500mcm 2 x #2 to 600mcm 3 x #2 to 600mcm ???? lug dz2 fg dz2 fg dz2 fh dz2 fj dz2 fk dz2 fl ? ? ? ? tightening torque using dz2f ?? lug bolt lug to contactor lb-in 160 160 310 310 310 510 ? ? ? ? wire pressure screw lb-in 200 200 275 500 500 500 ? ? ? ? bus bar connections number of bars ??????2234 bar c.s.a. mm in ?????? 50 x 5 1.9 x 0.2 80 x 5 3.1 x 0.2 100 x 5 3.9 x 0.2 100 x 10 3.9 x 0.2 bolt diameter ??????4 x ? 84 x ? 104 x ? 104 x ? 10 tightening torque lb-in ? ? ? ? ? ? 185 310 310 310 p cr1f150 to cr1f630 only. cr1b contactors are not ul listed or csa certified. f paralleling of poles must be carried out only in accordance with the fuse manufacturer's recommendations. k select short circuit protection to meet the national electrical code or other local codes and standards.
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? characteristics 227 01/04 ? 2001-2004 schneider electric all rights reserved type cr1f150 cr1f185 cr1f265 cr1f400 cr1f500 cr1f630 cr1bl cr1bm cr1bp cr1br control circuit characteristics rated control circuit voltage (vc) ac 50 or 60 hz v 48 to 415 110 to 500 ac 400 hz v 48 to 220 110 to 500 dc v 48 to 220 110 to 500 dc low consumption v 48 to 220 ? control voltage limits ac and dc energization 0.85 to 1.1 vc de-energization 0.85 to 1.1 vc max. operating rate at ambient temperature 40 c (104 f) in operating cycles/hour 600 120 mechanical durability in millions of operating cycles 1 average consumption energization 1-pole va??????650650650650 50/60 hz 2-pole va??????1100110011001100 3-pole va 1100 1600 1650 1450 1650 2100 1650 1650 1650 1650 4-pole va 1100 1600 1650 1450 1650 2100 1850 1850 1850 1850 de-energization 1-pole va??????110110110110 2-pole va??????125125125125 3-pole va 7.3 8 9 12 9.5 8 165 165 165 165 4-pole va 7.3 8 9 12 9.5 8 175 175 175 175 400 hz and dc energization 1-pole va??????600600600600 2-pole va??????1000100010001000 3-pole va 1260 1750 1800 1600 1800 2300 1500 1500 1500 1500 4-pole va 1260 1750 1800 1600 1800 2300 1700 1700 1700 1700 de-energization 1-pole va??????100100100100 2-pole va??????115115115115 3-pole va 10 11 12 16 13 11 150 150 150 150 4-pole va 10 11 12 16 13 11 160 160 160 160 dc low consumption energization 3/4-pole w 500 500 500 500 550 620 ? ? ? ? de-energization 3/4-pole w 15 20 40 70 60 45 ? ? ? ? average operating time at vc q energization ms 35 to 40 35 to 40 45 to 50 40 to 75 40 to 80 40 to 80 100 to 150 100 to 150 100 to 150 100 to 150 de-energization ms 50 to 100 50 to 100 50 to 100 50 to 100 50 to 100 50 to 100 20 to 40 20 to 40 20 to 40 20 to 40 q the closing time is measured from the moment the coil supply is switched on to initial contact of the main poles. the opening t ime is measured from the moment the coil supply is switched off to the moment the main poles separate. note: the arcing time depends on the circuit switched by the poles. for normal 3-phase applications the arcing time is usually l ess than 10 ms. the load is isolated from the supply after a time equal to the sum of the opening time and the arcing time. auxiliary contact characteristics type la1d for contactors cr1f z c4gm for contactors cr1b conventional rated thermal current a10 20 rated insulation voltage (vi) conforming to iec 60947-5-1 v 660 conforming to vde 0110 grc v 750 cabling flexible or solid conductor with or without cable end mm 2 1 x 1 min/2 x 2.5 max (1 - #16 min / 2 - # 14 max) 2 min/4 max (# 14 min / # 10 max) operational power of contact s la1d for contactors cr1f ac supply electrical durability (valid for up to 2400 operating cycles/h) on an inductive load such as the coil of an electromagnet (power factor = 0.7) = 10 times the breaking current (power factor = 0.4). dc supply electrical durability (valid for up to 1200 operating cycles/h) on an inductive load such as the coil of an electromagnet without economy resistor, the time constant increasing with the load. v 48 110/127 220/230 380/400 600 v 48 110 220 440 600 1 million operating cycles va 300 400 480 500 500 w 90 75 68 61 58 occasional making capacity va 2600 7000 13 000 15 000 9000 w 700 400 260 220 170 operational power of contact s zc4gm for contactors cr1b ac supply electrical durability (valid for up to 2400 operating cycles/h) on an inductive load such as the coil of an electromagnet (power factor = 0.7) = 10 times the breaking current (power factor = 0.4). dc supply electrical durability (valid for up to 1200 op erating cycles/h) on an inductive load such as the coil of an electromagnet without economy resistor, the time constant increasing with the load. v 110/127 220 380 415/440 500 v 110 120 440 500 1 million operating cycles va 2000 4000 4000 4000 3500 w 250 250 230 200 occasional making capacity va 14000 23000 35000 45000 35000 w 1600 800 400 360
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? characteristics ? 2001-2004 schneider electric all rights reserved 228 01/04 for utilization category ac-1 and according to required electrical durability maximum operational curr ent (on-load factor 0.95) increase in operational current by paralleling of poles apply the following multiplying factors to the current va lues given above; these factors take into account the often unbalanced current distribution between poles:  2 poles in parallel: k = 1.6  3 poles in parallel: k = 2.25  4 poles in parallel: k = 2.8 electrical durability (ve 440 v) note: for 660 v, multiply the nu mber of operating cycles by 0.8. example ve = 220 v, ie = 200 a, q = 40 c (104 f), ic = ie = 200 a. 600,000 operating cycles required. the above selection curves show the contactor rating needed: cr1f400 . maximum operating rate: 120 operating cycles/hour contactor size cr1 f150 cr1 f185 cr1 f265 cr1 f400 cr1 f500 cr1 f630 cr1 bl cr1 bm cr1 bp cr1 br cable c.s.a. mm 2 120 (250 mcm) 150 (300 mcm) 185 (350 mcm) ??????? number of bars ???2222234 bar c.s.a. mm in ??? 30 x 5 1.18 x 0.2 40 x 5 1.57 x 0.2 60 x 5 2.36 x 0.2 50 x 5 1.96 x 0.2 80 x 5 3.14 x 0.2 100 x 5 3.93 x 0.2 100 x 5 3.93 x 0.2 operational current in category ac-1 at ambient temperature 40 c (104 f) a 250 275 350 500 700 1000 800 1250 2000 2750 55 c (131 f) a 250 275 300 430 580 850 700 1100 1750 2400 70 c (158 f) a 170 180 250 340 500 700 600 900 1500 2000 0.01 80 60 100 250 275 400 350 500 600 700 800 1000 1250 2000 2750 4000 0.02 0.04 0.06 0.08 0.1 0.2 0.4 0.6 0.8 1 cr1-f150 cr1-f185 cr1-f265 cr1-f400 cr1-f500 cr1-f630 cr1-bl, bm cr1-bp cr1-br millions of operating cycles current broken in a
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? characteristics 229 01/04 ? 2001-2004 schneider electric all rights reserved for switching the primari es of 3-phase transformers international applications only (not ul listed or csa certified for transformer switching) operating conditions maximum ambient temperature: 55 c (131 f) maximum operational voltage: 1000 v, 50 to 60 hz when a transformer is switched on, there is genera lly an initial current surge which reaches its peak value almost instantaneously and then decreases in a largely exponential manner to quickly reach its steady state value. the value of this current depends on:  the characteristics of the magnetic circuit and of the windings (cross sectional area of the core, rated inductance, number of turns, size of the windings).  the performance of the magnetic laminations us ed (residual induction and saturation inductance).  the magnetic state of the circuit and the instantaneo us value of the ac mains voltage at the moment of switch-on. the inrush current at the moment of switch-on can re ach 20 to 40 times the rated current for the various kva power ratings in the tables below. this value is independent of the ?no-load? or ?on-load? state of the transformer (the tables are based on 30 in). the peak magnetizing current of the tr ansformer must be lower than the values given in the tables below. contactor selection maximum operating rate: 120 operating cycles /hour contactor size cr1f150 cr1f185 cr1f265 cr1f400 cr1f500 cr1f630 maximum permissible closing current peak a 1700 2800 3500 5500 6800 9000 maximum operational power in kva c 220 to 230 v 25 40 50 75 100 140 380 to 400 v 50 75 90 130 170 225 415 to 440 v 55 80 100 140 190 250 500 v 65 95 110 170 225 280 660 v 80 120 140 200 270 315 1000 v 100 150 200 250 375 470 contactor size cr1bl cr1bm cr1bp cr1br maximum permissible closing current peak a 18 000 18 000 24 000 30 000 maximum operational power in kva c 220 to 230 v 230 230 300 380 380 to 400 v 400 400 530 660 415 to 440 v 450 450 560 700 500 v 480 480 600 750 660 v 600 600 800 950 1000 v 700 700 1000 1200 c maximum operational power corresponding to a current peak at switch-on of 30 in.
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? ac or dc ? selection ? 2001-2004 schneider electric all rights reserved 230 01/04 magnetic latching contactors - ac or dc - selection maximum thermal current in category ac-1 rated operational current in category ac-3 power poles auxiliary contacts catalog number p weight lb (kg) a a n.o. n.o. n.c. 250 150 3?? cr1f150 ? 0.14 (3.500) 4?? cr1f1504 ? 0.15 (3.800) 275 185 3?? cr1f185 ? 0.18 (4.600) 4?? cr1f1854 ? 0.21 (5.400) 350 265 3?? cr1f265 ? 0.29 (7.400) 4?? cr1f2654 ? 0.33 (8.500) 500 400 3?? cr1f400 ? 0.36 (9.100) 4?? cr1f4004 ? 0.40 (10.200) 700 500 3?? cr1f500 ? 0.44 (11.300) 4?? cr1f5004 ? 0.51 (12.900) 1000 630 3?? cr1f630 ? 0.73 (18.600) 4?? cr1f6304 ? 0.84 (21.500) 800 750 1 12 cr1bl31 ? 12 1.26 (32.000) 21 cr1bl31 ? 21 1.26 (32.000) 3? cr1bl31 ? 30 1.26 (32.000) 2 12 cr1bl32 ? 12 1.77 (45.000) 21 cr1bl32 ? 21 1.77 (45.000) 3? cr1bl32 ? 30 1.77 (45.000) 3 12 cr1bl33 ? 12 2.30 (58.000) 21 cr1bl33 ? 21 2.30 (58.000) 3? cr1bl33 ? 30 2.30 (58.000) 4 12 cr1bl34 ? 12 2.83 (72.000) 21 cr1bl34 ? 21 2.83 (72.000) 3? cr1bl34 ? 30 2.83 (72.000) 1250 1000 1 12 cr1bm31 ? 12 1.22 (31.000) 21 cr1bm31 ? 21 1.22 (31.000) 3? cr1bm31 ? 30 1.22 (31.000) 2 12 cr1bm32 ? 12 1.73 (44.000) 21 cr1bm32 ? 21 1.73 (44.000) 3? cr1bm32 ? 30 1.73 (44.000) 3 12 cr1bm33 ? 12 2.24 (57.000) 21 cr1bm33 ? 21 2.24 (57.000) 3? cr1bm33 ? 30 2.24 (57.000) 4 12 cr1bm34 ? 12 2.79 (71.000) 21 cr1bm34 ? 21 2.79 (71.000) 3? cr1bm34 ? 30 2.79 (71.000) 2000 1500 1 12 cr1bp31 ? 12 1.61 (41.000) 21 cr1bp31 ? 21 1.61 (41.000) 3? cr1bp31 ? 30 1.61 (41.000) 2 12 cr1bp32 ? 12 2.55 (65.000) 21 cr1bp32 ? 21 2.55 (65.000) 3? cr1bp32 ? 30 2.55 (65.000) 3 12 cr1bp33 ? 12 3.70 (94.000) 21 cr1bp33 ? 21 3.70 (94.000) 3? cr1bp33 ? 30 3.70 (94.000) 4 12 cr1bp34 ? 12 4.72 (120.000) 21 cr1bp34 ? 21 4.72 (120.000) 3? cr1bp34 ? 30 4.72 (120.000) 2750 1800 1 12 cr1br31 ? 12 2.05 (52.000) 21 cr1br31 ? 21 2.05 (52.000) 3? cr1br31 ? 30 2.05 (52.000) 2 12 cr1br32 ? 12 3.34 (85.000) 21 cr1br32 ? 21 3.34 (85.000) 3? cr1br32 ? 30 3.34 (85.000) 3 12 cr1br33 ? 12 5.07 (129.000) 21 cr1br33 ? 21 5.07 (129.000) 3? cr1br33 ? 30 5.07 (129.000) 4 12 cr1br34 ? 12 6.29 (160.000) 21 cr1br34 ? 21 6.29 (160.000) 3? cr1br34 ? 30 6.29 (160.000) p for standard control circuit voltages, see page 231. cr1f1854 ? cr1f500 cr1bp33
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? accessories ? selection 231 01/04 ? 2001-2004 schneider electric all rights reserved magnetic latching contactors - accessories - selection lug kits lugs can be ordered either individually (for 2- and 4-pole contactors) or in sets of 6 (for 3-pole contactors). mounting hard ware is provided with the contactors, not the kits. for contactors cr1f description number of contacts or shrouds for use on catalog number weight lb (kg) instantaneous auxiliary contacts 1 to 9 cr1f la1d c 1.27 (0.580) time delay auxiliary contacts 2 to 4 cr1f la ? d c 1.27 (0.580) insulated terminal blocks provides ip20 touch-safe protection set of 2 blocks cr1f150 and cr1f185 awg cable size #6 to 300mcm la9f103 0.66 (0.300) c for selection, see pages 194 through 197. single lug set of six lugs cable size awg range suitable for contactor lc1 ???? / cr1 ???? suitable for overload relay lr9 ????? q dz2ff1 dz2ff6 14 to 2/0 f115 none dz2fg1 dz2fg6 6 to 3/0 f150, f185 f5 ? 57, f5 ? 63, f5 ? 67, f5 ? 69 dz2fh1 dz2fh6 6 to 300 mcm f265, f330 lr9f ? 71 dz3fj1 dz3fj6 4 to 500 mcm f400 none dz2fk1 dz2fk6 2 x 2 to 600 mcm f500 f7 ? 75, f7 ? 79 dz2fl ? f dz2fl6 3 x 2 to 600 mcm f630, f800 f7 ? 81 dzf2fx dz2fx6 4 x 1/0 to 750 mcm f780 none q when direct mounting the lr9f to an lc1f or cr1f contactor, lugs of different sizes may be required. see page 220 for additional information. f for 3-pole f630 contactors, order dz2fl1 for l1 and t3, dz2fl2 for l2 and t2 and dz2pl3 for l3 and t1 terminals. for 4-pole f6304 contactors, order dz2fl1 for l1 and t4, dz2fl2 for l2, t2, l3 and t3 and dz2fl3 for l4 and t1 terminals. description application catalog number mechanical interlock and power connections for assembly of reversing contactors and changeover contactor pairs see pages 190 to 193. for contactors cr1b description application catal og number weight lb (kg) mechanical interlock with mounting accessories p for vertical assembly of reversing contactors and changeover contactor pairs ez2lb0601 3.44 (1.560) kit containing 2 bar mounting brackets for mounting on 120 or 150 mm center (4.72" or 5.91") la9b103 3.57 (1.620) p positive mechanical interlocking between two vertically-mounted contactors with identical or different ratings. connecting rods and cranks assembled on right-hand side, crank pins on the pole side. vertical mounting center distance between the two contactors: 600 mm (23.62"). coil selection volts 48 110 125 127 220 230 240 250 380 400 415 440 500 for contactors cr1f ac 50/60 hz e7 f7 ? g7 m7 m7 u7 ? q7 q7 n7 ? ? ac 400 hz e7f7?g7m7m7??????? dc e7f7?g7m7m7??????? dc low consumption ez7 fz7 ? gz7 mz7 ? ? ? ? ? ? ? ? for contactors cr1b ac 50 to 400 hz f ? g m m u ? q v n r s dc fdgd?md?udvcd???rdsd la1dn22 la ? dt, ds la9f103 ez2lb0601 dz2f ??
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? mechanical interlocks and power connections ? 2001-2004 schneider electric all rights reserved 232 01/04 magnetic latching contactors - mechanical interlocks and power connections components for assembling reversing contactors and c hangeover pairs cr1f horizontally or vertically mounted horizontally mounted mechanical interlocks sets of power connections reversers assembled using 2 contactors of identical rating type: cr1f150 cr1f185 cr1f265 cr1f400 cr1f500 cr1f630 la9f ? 970 reversing contactors la9f ? 976 3 or 4-pole changeover contactor pairs la9f ? 977 or la9f ? 982 vertically mounted mechanical interlocks reversers assembled using 2 contactors of identical rating type: cr1f150 cr1f185 cr1f265 cr1f400 cr1f500 cr1f630 la9ff4f la9fg4g assembly a la9fh4h la9fj4j la9fk4k la9fl4l assembly c reversers assembled using 2 contactors of different ratings type: cr1f150 cr1f185 cr1f265 cr1f400 cr1f500 cr1f630 la9fg4f assembly a la9fh4f la9fj4f la9fk4f la9fl4f la9fh4g la9fj4g la9fk4g la9fl4g assembly b la9fj4h la9fk4h la9fl4h la9fk4j la9fl4j la9fk4k assembly c reversers assembled using 3 contactors of identical or different ratings la9f ? 4 ? 4 ? warning: the contactor ratings must be in descending order from top to bottom. a1 e1 a2 a1 a2 e1 1 2 3 4 5 6 1 2 3 4 5 6 l1 l2 l3 u v w a1 e1 a2 a1 a2 e1 1 2 3 4 5 6 3 4 5 6 7 8 1n 1/l3 1/l2 l2 1 2 l1 7 8 1/l1 2/l1 2/l2 2/l3 2n l3 n f150 f185 f265 f400 f500 f630 f150 f185 f265 f400 f500 f630 f185 f265 f400 f150 f500 f630 cr1-f500 cr1-f265 cr1-f185 a b c
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? mechanical interlocks and power connections 233 01/04 ? 2001-2004 schneider electric all rights reserved components for assembling reversing contactors and changeover pairs cr1f reversers assembled using 2 co ntactors of identical rating contactor type set of power connections mechanical interlock catalog number weight lb (kg) ki t catalog number weight lb (kg) for assembly of 3-pole reversing contactors for motor control c horizontally mounted cr1f150 la9ff976 0.02 (0.600) la9ff970 0.13 (0.060) cr1f185 la9fg976 0.03 (0.780) la9fg970 0.13 (0.060) cr1f265 la9fh976 0.05 (1.500) la9fj970 0.31 (0.140) cr1f400 la9fj976 0.08 (2.100) la9fj970 0.31 (0.140) cr1f500 la9fk976 0.09 (2.350) la9fj970 0.31 (0.140) cr1f630 la9fl976 0.15 (3.800) la9fl970 0.33 (0.150) vertically mounted cr1f150 k la9ff4f 0.76 (0.345) cr1f185 k la9fg4g 0.77 (0.350) cr1f265 k la9fh4h 2.33 (1.060) cr1f400 k la9fj4j 2.64 (1.200) cr1f500 k la9fk4k 2.64 (1.200) cr1f630 k la9fl4l 2.68 (1.220) for assembly of 4-pole changeover contactor pairs for distribution horizontally mounted cr1f1504 la9ff977 0.01 (0.460) la9ff970 0.13 (0.060) cr1f1854 la9fg977 0.02 (0.610) la9fg970 0.13 (0.060) cr1f2654 la9fh977 0.04 (1.200) la9fj970 0.31 (0.140) cr1f4004 la9fj977 0.07 (1.800) la9fj970 0.31 (0.140) cr1f5004 la9fk977 0.09 (2.300) la9fj970 0.31 (0.140) cr1f6304 la9fl977 0.13 (3.400) la9fl970 0.33 (0.150) vertically mounted cr1f1504 k la9ff4f 0.76 (0.345) cr1f1854 k la9fg4g 0.77 (0.350) cr1f2654 k la9fh4h 2.33 (1.060) cr1f4004 k la9fj4j 2.64 (1.200) cr1f5004 k la9fk4k 2.64 (1.200) cr1f6304 k la9fl4l 2.68 (1.220) reversers assembled using 2 contactors of different ratings for assembly of 3 or 4-pole changeover contactor pairs for distribution contactor type (vertically-mounted) q set of power connections mechanical interlock catalog number kit catalog number weight (kg) (kg x 2.2 = lbs) at bottom at top cr1f150 or f1504 cr1f185 or f1854 la9fg4f 0.77 (0.350) cr1f265 or f2654 la9fh4f 1.92 (0.870) cr1f400 or f4004 la9fj4f 2.05 (0.930) cr1f500 or f5004 la9fk4f 2.07 (0.940) cr1f630 or f6304 la9fl4f 2.07 (0.940) cr1f185 or f1854 cr1f265 or f2654 la9fh4g 1.89 (0.860) cr1f400 or f4004 la9fj4g 2.07 (0.940) cr1f500 or f5004 la9fk4g 2.07 (0.940) cr1f630 or f6304 la9fl4g 2.09 (0.950) cr1f265 or f2654 cr1f400 or f4004 la9fj4h 2.49 (1.130) cr1f500 or f5004 la9fk4h 2.49 (1.130) cr1f630 or f6304 la9fl4h 2.51 (1.140) cr1f400 or f4004 cr1f500 or f5004 la9fk4j 2.64 (1.200) cr1f630 or f6304 la9fl4j 2.66 (1.210) cr1f500 or f5004 cr1f630 or f6304 la9fl4k 2.66 (1.210) for assembly of 3 or 4-pole reversing contactors using 3 contactors (vertically mounted) of identical or different rating mechanical interlock kit catalog number f the contactor ratings must be in descending order from top to bottom la9f ? 4 ? 4 ? c a 3-pole reversing contactor for motor control can be converted into a 3-pole changeover contactor pair by removing the upper c onnecting links. k all power connections to be made by the customer. q with identical or different number of poles. power connections to be made by the customer. f complete the catalog number by replacing the first dot with the code for the upper contactor, the second dot with the code for the middle contactor, and the third dot with the code for the lower contactor; see the table below for the codes for the contactors. contactors cr1f150 cr1f185 cr1f265 cr1f400 cr1f500 cr1f630 code f g h j k l for example, mechanical interlock for reversing contactor made up of 3 different contactors: cr1f500 top, cr1f265 middle, and c r1f185 lower: la9f ? 4 ? 4 ? becomes la9fk4h4g .
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? coils for contactors cr1f ? 2001-2004 schneider electric all rights reserved 234 01/04 magnetic latching contactors - coils for contactors cr1f standard coils usual voltages resistance of winding at 20 c (68 f) catalog number voltage code weight lb (kg) 50 to 400 hz or dc 50 hz, 60 hz la tching unlatching vv ?? for contactors cr1f150 48 ? 1.98 230.8 lx0ff005 e7 0.97 (0.440) 110 ? 9.35 1453 lx0ff006 f7 0.97 (0.440) 127 ? 11.61 1788 lx0ff007 g7 0.97 (0.440) 208 ? 23.50 4098 lx0ff020 l7 0.97 (0.440) 220/230 ? 37.55 5139 lx0ff008 m7 0.97 (0.440) ? 240 45.16 6544 lx0ff009 u7 0.97 (0.440) ? 380/400 114.10 12447 lx0ff010 q7 0.97 (0.440) ? 415 139.50 16717 lx0ff011 n7 0.97 (0.440) for contactors cr1f185 48 ? 1.42 220 lx0fg005 e7 1.23 (0.560) 110 ? 6.92 1339 lx0fg006 f7 1.23 (0.560) 127 ? 8.45 1676 lx0fg007 g7 1.23 (0.560) 208 ? 21.30 3169 lx0fg020 l7 1.23 (0.560) 220/230 ? 26.27 4729 lx0fg008 m7 1.23 (0.560) ? 240 32.95 4729 lx0fg009 u7 1.23 (0.560) ? 380/400 82.29 11885 lx0fg010 q7 1.23 (0.560) ? 415 102.30 14305 lx0fg011 n7 1.23 (0.560) for contactors cr1f265 48 ? 1.34 183.4 lx0fh005 e7 1.71 (0.780) 110 ? 6.90 1031 lx0fh006 f7 1.71 (0.780) 127 ? 8.56 1325 lx0fh007 g7 1.71 (0.780) 208 ? 20.20 2654 lx0fh020 l7 1.71 (0.780) 220/230 ? 25.77 4090 lx0fh008 m7 1.71 (0.780) ? 240 33.03 5002 lx0fh009 u7 1.71 (0.780) ? 380/400 78.39 11803 lx0fh010 q7 1.71 (0.780) ? 415 102.9 15006 lx0fh011 n7 1.71 (0.780) for contactors cr1f400 48 ? 1.32 90.5 lx0fj005 e7 2.47 (1.120) 110 ? 8.09 813 lx0fj006 f7 2.47 (1.120) 127 ? 9.79 1027 lx0fj007 g7 2.47 (1.120) 208 ? 24.40 2643 lx0fj020 l7 2.47 (1.120) 220/230 ? 30.14 3309 lx0fj008 m7 2.47 (1.120) ? 240 37.02 4074 lx0fj009 u7 2.47 (1.120) ? 380/400 94.80 9380 lx0fj010 q7 2.47 (1.120) ? 415 121.10 11 763 lx0fj011 n7 2.47 (1.120) for contactors cr1f500 48 ? 1.57 166 lx0fk005 e7 2.70 (1.220) 110 ? 7.53 916 lx0fk006 f7 2.70 (1.220) 127 ? 9.56 1159 lx0fk007 g7 2.70 (1.220) 208 ? 23.60 2981 lx0fk020 l7 2.70 (1.220) 220/230 ? 28.81 3733 lx0fk008 m7 2.70 (1.220) ? 240 35.67 4595 lx0fk009 u7 2.70 (1.220) ? 380/400 89.56 10 570 lx0fk010 q7 2.70 (1.220) ? 415 112.06 13 256 lx0fk011 n7 2.70 (1.220) for contactors cr1f630 48 ? 0.87 204 lx0fl005 e7 3.21 (1.460) 110 ? 5.20 1423 lx0fl006 f7 3.21 (1.460) 127 ? 6.45 1830 lx0fl007 g7 3.21 (1.460) 208 ? 20.20 2961 lx0fl020 l7 3.21 (1.460) 220/230 ? 25.36 4603 lx0fl008 m7 3.21 (1.460) ? 240 25.36 5658 lx0fl009 u7 3.21 (1.460) ? 380/400 60.95 10 676 lx0fl010 q7 3.21 (1.460) ? 415 77.97 13 003 lx0fl011 n7 3.21 (1.460) lx0ff009 lx0fh009
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? coils for contactors cr1f 235 01/04 ? 2001-2004 schneider electric all rights reserved special coils coils with two windings with common point, allowing the use of two separate power sources for latching and unlatching. for contactors coil voltages at 50 hz, 60 hz, 400 hz or dc resistance of winding at = 20 c (68 f) catalog number voltage code weight lb (kg) latching unlatching latching unlatching vv ?? cr1f150 220 24 29.5 39.5 lx0ff224 mb7 0.01 (0.440) cr1f185 220 24 26.5 19 lx0fg224 mb7 0.02 (0.560) cr1f265 220 24 26 29.5 lx0fh224 mb7 0.03 (0.780) cr1f400 220 24 30 23 lx0fj224 mb7 0.04 (1.120) cr1f500 220 24 29 26 lx0fk224 mb7 0.05 (1.220) cr1f630 220 24 26 41 lx0fl224 mb7 0.06 (1.460) coils with low-inrush consumption usual voltages dc resistance of winding at = 20 c (68 f) catalog number voltage code weight lb (kg) latching unlatching v ?? for contactors cr1f150 48 4.56 140.56 lx0ff055 ez7 0.01 (0.440) 110 22.37 706.44 lx0ff056 fz7 0.01 (0.440) 127 35.54 1086.36 lx0ff057 gz7 0.01 (0.440) 220 89.85 3342.51 lx0ff058 mz7 0.01 (0.440) for contactors cr1f185 48 5.19 106.54 lx0fg055 ez7 0.02 (0.570) 110 25.50 536.26 lx0fg056 fz7 0.02 (0.570) 127 32.75 732.64 lx0fg057 gz7 0.02 (0.570) 220 102.44 2378.62 lx0fg058 mz7 0.02 (0.570) for contactors cr1f265 48 5.19 74.26 lx0fh055 ez7 0.03 (0.800) 110 25 364.61 lx0fh056 fz7 0.03 (0.800) 127 30.98 458.45 lx0fh057 gz7 0.03 (0.800) 220 97.89 1344.46 lx0fh058 mz7 0.03 (0.800) for contactors cr1f400 48 5.05 36.36 lx0fj055 ez7 0.04 (1.150) 110 25.39 171.49 lx0fj056 fz7 0.04 (1.150) 127 31.86 221.20 lx0fj057 gz7 0.04 (1.150) 220 98.19 648.79 lx0fj058 mz7 0.04 (1.150) for contactors cr1f500 48 4.42 41 lx0fk055 ez7 0.05 (1.270) 110 22.74 193.36 lx0fk056 fz7 0.05 (1.270) 127 28.25 313.60 lx0fk057 gz7 0.05 (1.270) 220 85.12 918.68 lx0fk058 mz7 0.05 (1.270) for contactors cr1f630 48 3.94 59.17 lx0fl055 ez7 0.06 (1.500) 110 19.36 365.33 lx0fl056 fz7 0.06 (1.500) 127 25.39 452.27 lx0fl057 gz7 0.06 (1.500) 220 74.44 1071.43 lx0fl058 mz7 0.06 (1.500) lx0ff020
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? coils for contactors cr1b ? 2001-2004 schneider electric all rights reserved 236 01/04 magnetic latching contactors - coils for contactors cr1b coils with ?tc? treatment f usual voltages resistance at = 20 c (68 f) catalog number weight lb (kg) dc ac 50 to 400 hz vv ? for contactors cr1b ? 31 ? 110 to 120 19.7 wb1kb140 2.47 (1.120) 110 to 125 ? 25.2 wb1kb134 2.47 (1.120) ? 220 to 240 77.2 wb1kb136 2.47 (1.120) 220 ? 94 wb1kb139 2.47 (1.120) 250 ? 128 wb1kb125 2.47 (1.120) ? 380 to 400 197 wb1kb126 2.47 (1.120) ? 415 to 440 257 wb1kb138 2.47 (1.120) for contactors cr1b ? 32 ?1109.6 wb1kb133 2.47 (1.120) 110 120 to 127 11.4 wb1kb121 2.47 (1.120) 125 ? 19.7 wb1kb140 2.47 (1.120) ? 220/230 32.5 wb1kb124 2.47 (1.120) 220 240 49.7 wb1kb122 2.47 (1.120) 250 ? 77.2 wb1kb136 2.47 (1.120) ? 380 to 400 128 wb1kb125 2.47 (1.120) ? 415 to 440 160 wb1kb137 2.47 (1.120) for contactors cr1b ? 33 ?1107.2 wb1kb123 2.47 (1.120) 110 120 to 127 9.6 wb1kb133 2.47 (1.120) 125 ? 11.4 wb1kb121 2.47 (1.120) 220 240 32.5 wb1kb124 2.47 (1.120) 250 ? 61 wb1kb135 2.47 (1.120) ? 380 to 415 94 wb1kb139 2.47 (1.120) ? 440 128 wb1kb125 2.47 (1.120) for contactors cr1b k 34 ?1105.8 wb1kb132 2.47 (1.120) 110 120 to 127 7.2 wb1kb123 2.47 (1.120) 125 ? 11.4 wb1kb121 2.47 (1.120) ? 220/230 25.2 wb1kb134 2.47 (1.120) ? 240 32.5 wb1kb124 2.47 (1.120) 250 ? 49.7 wb1kb122 2.47 (1.120) ? 380 77.2 wb1kb136 2.47 (1.120) ? 400 to 440 94 wb1kb139 2.47 (1.120) coils with ?th? treatment p add suffix th to the above catalog numbers; for example, wb1kb140th . f ?tc? treatment is standard environmental protection equivalent to tropicalization. p ?th? treatment is improved environmental protection equivalent to fungus-proof and insect-proof. see page 10 for additional information regarding protective treatments. wb1kb ???
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? coils for contactors cr1b 237 01/04 ? 2001-2004 schneider electric all rights reserved accessories for use with coils coils (?tc? or ?th?) additional resistors c automatic coil cut-out contact q rectifier f r1 catalog number r2 catalog number no. catalog number catalog number ?? for contactors cr1b ? 31 wb1kb140 68 dr2sc0068 47 dr2sc0047 2 zc4gm2 or zc4gm8 dr5te1u wb1kb134 68 dr2sc0068 68 dr2sc0068 2 zc4gm2 or zc4gm8 ? wb1kb136 220 dr2sc0220 180 dr2sc0180 2 zc4gm2 or zc4gm8 dr5te1u wb1kb139 270 dr2sc0270 220 dr2sc0220 2 zc4gm2 or zc4gm8 ? wb1kb125 330 dr2sc0330 270 dr2sc0270 3 zc4gm2 or zc4gm8 ? wb1kb126 470 dr2sc0470 470 dr2sc0470 3 zc4gm2 or zc4gm8 dr5te1s wb1kb138 1000 dr2sc1000 470 dr2sc0470 3 zc4gm2 or zc4gm8 dr5te1s for contactors cr1b ? 32 wb1kb133 10 dr2sc0010 33 dr2sc0033 1 pr4fb0011 dr5te1u wb1kb121 47 dr2sc0047 39 dr2sc0039 1 pr4fb0010 dr5te1u wb1kb140 100 dr2sc0100 47 dr2sc0047 1 pr4fb0009 ? wb1kb124 120 dr2sc0120 120 dr2sc0120 1 pr4fb0007 dr5te1u wb1kb122 220 dr2sc0220 150 dr2sc0150 1 pr4fb0007 dr5te1u wb1kb136 330 dr2sc0330 220 dr2sc0220 1 pr4fb0006 ? wb1kb125 470 dr2sc0470 470 dr2sc0470 1 pr4fb0005 dr5te1s wb1kb137 680 dr2sc0680 560 dr2sc0560 1 pr4fb0004 dr5te1s for contactors cr1b ? 33 wb1kb123 39 dr2sc0039 27 dr2sc0027 1 pr4fb0012 dr5te1u wb1kb133 47 dr2sc0047 39 dr2sc0039 1 pr4fb0011 dr5te1u wb1kb121 56 dr2sc0056 47 dr2sc0047 1 pr4fb0010 ? wb1kb124 180 dr2sc0180 120 dr2sc0120 1 pr4fb0008 dr5te1u wb1kb135 270 dr2sc0270 270 dr2sc0270 1 pr4fb0006 ? wb1kb139 470 dr2sc0470 390 dr2sc0390 1 pr4fb0005 dr5te1s wb1kb125 680 dr2sc0680 470 dr2sc0470 1 pr4fb0004 dr5te1s for contactors cr1b ? 34 wb1kb132 33 dr2sc0033 27 dr2sc0027 1 pr4fb0014 dr5te1u wb1kb123 47 dr2sc0047 33 dr2sc0033 1 pr4fb0012 dr5te1u wb1kb121 56 dr2sc0056 56 dr2sc0056 1 pr4fb0010 ? wb1kb134 150 dr2sc0150 120 dr2sc0120 1 pr4fb0008 dr5te1u wb1kb124 180 dr2sc0180 150 dr2sc0150 1 pr4fb0007 dr5te1u wb1kb122 270 dr2sc0270 220 dr2sc0220 1 pr4fb0007 ? wb1kb136 390 dr2sc0390 390 dr2sc0390 1 pr4fb0006 dr5te1s wb1kb139 560 dr2sc0560 470 dr2sc0470 1 pr4fb0005 dr5te1s c weight of resistors dr2sc ???? : 0.030 kg (0.07 lbs). q weight of automatic coil cut-out contacts: zc4gm ? : 0.030 kg (0.07 lbs) and pr4fb00 ?? : 0.600 kg (1.32 lbs). f weight of rectifier dr5te1 ? : 0.100 kg (0.22 lbs). the rectifier is for use on ac only. dr2sc0220 zc4gm2 pr4fb0014 dr5te1u
cr1f/cr1b contacto rs and accessories magnetic latching contactors ? accessories and replacement parts ? 2001-2004 schneider electric all rights reserved 238 01/04 for contactors cr1f description for contactors ca talog number weight lb (kg) sets of contacts for 3 or 4 poles f 3-pole cr1f150 la5ff431 0.59 (0.270) cr1f185 la5fg431 0.77 (0.350) cr1f265 la5fh431 1.45 (0.660) cr1f400 la5f400803 1.45 (0.660) cr1f500 la5f500803 1.45 (0.660) cr1f630 la5f630803 1.45 (0.660) 4-pole cr1f1504 la5ff441 0.79 (0.360) cr1f1854 la5fg441 1.02 (0.465) cr1f2654 la5fh441 1.94 (0.880) cr1f4004 la5f400804 1.02 (0.465) cr1f5004 la5f500804 1.02 (0.465) cr1f6304 la5f630804 1.02 (0.465) arc chambers 3-pole cr1f150 la5f15050 1.08 (0.490) cr1f185 la5f18550 1.47 (0.670) cr1f265 la5f26550 2.02 (0.920) cr1f400 la5f40050 2.86 1.300) cr1f500 la5f50050 4.07 (1.850) cr1f630 la5f63050 6.94 (3.150) 4-pole cr1f1504 la5f150450 1.45 (0.660) cr1f1854 la5f185450 2.00 (0.910) cr1f2654 la5f265450 2.68 (1.220) cr1f4004 la5f400450 3.83 1.740) cr1f5004 la5f500450 5.51 (2.500) cr1f6304 la5f630450 9.25 (4.200) f set containing the following (per pole): 2 fixed contacts, 1 moving contact , 2 deflectors, 1 back-plate, clamping screws and w ashers. for contactors cr1b description for contactors number of sets required per pole unit catalog number of set weight lb (kg) set of contacts (1 moving contact, 1 fixed contact) cr1bl 1 pa1l b80 0.92 (0.420) cr1bm 1 pa1l b80 0.92 (0.420) cr1bp 2 pa1l b80 0.92 (0.420) cr1br 3 pa1l b80 0.92 (0.420) description for contacto rs composition catalog number weight lb (kg) moving contact only (for one finger) all ratings ? pa1l b75 0.48 (0.220) fixed contact only (for one finger) all ratings ? pa1l b76 0.44 (0.200) blow-out horn only (for one finger) all ratings ? pa1l b89 0.26 (0.120) arc chambers (for a single pole) cr1bl ? pa1l b50 8.15 (3.700) cr1bm ? pa1l b50 8.15 (3.700) cr1bp ? pa1p b5 0 13.6 (6.200) cr1br ? pa1r b50 18.7 (8.500) auxiliary contact blocks all ratings 1 n.o. contact normal zc4gm1 0.06 (0.030) all ratings 1 n.c. contact normal zc4gm2 0.06 (0.030) all ratings 1 n.o. contact gold flashed zc4gm9 0.06 (0.030) all ratings 1 n.c. contact gold flashed zc4gm8 0.06 (0.030) n.c. pole for automatic cut-out coil all ratings ? pr4fb00 ?? c 1.32 (0.600) set of moving and fixed contacts for n.c. pole all ratings ? pv1fa80 0.07 (0.035) arc chamber for n.c. pole all ratings ? pn1fb50 0.48 (0.220) electromagnet all ratings ? et1kb50 23.3 (10.600) description for contactors no. of parts required catal og number weight lb (kg) return springs for moving part of electromagnet cr1b (1 pole) 1 dv1rt292 0.11 (0.050) cr1b (2, 3 or 4 poles) 2 dv1rt292 0.11 (0.050) n.o. pole springs cr1bl, bm or bp 1 per pole dv1rc201 0.04 (0.020) cr1br 1 per pole dv1rc155 0.04 (0.020) c select complete catalog number from page 259. la5fg431 la5f40050 pr4fb00 ?? pa1lb80 (palb76 + pa1lb75 ) zc4gm1 pa1lb89 pa1lb 50
cr1f/cr1b contacto rs and accessories magnetic latching contactors type cr1f ? dimensions 239 01/04 ? 2001-2004 schneider electric all rights reserved magnetic latching contactors type cr1f - dimensions dimensions shown in millimeters (mm x .0394 = inches) cr1f150 to cr1f500 common side view cr1f150, cr1f185, cr1f265 cr1f400, cr1f500 cr1f150 cr1f185 cr1f265 cr1f400 cr1f500 3 pole 4 pole 3 pole 4 pole 3 pole 4 pole 3 pole 4 pole 3 pole 4 pole a 163.5 201.5 168.5 208.5 201.5 244.5 a 213 261 233 288 b 170 170 174 174 203 203 g min 66 66 66 66 b1 137 137 137 137 145 145 b 206 206 238 238 b2 301 301 305 305 370 370 b2 375 375 400 400 c 171 171 181 181 213 213 c 219 219 232 232 f 131 131 130 130 147 147 f 146 146 150 150 g 106 143 111 151 142 190 g supplied 80 80 80 140 g1 80 80 80 80 96 96 g max 102 150 120 175 j 106 106 106 106 106 106 g1 supplied 170 170 170 230 j1 120 120 120 120 120 120 g1 min 156 156 156 156 l 107 107 113.5 113.5 141 141 g1 max 192 240 210 265 m 150 150 154 154 178 178 j1 12 60 32 27 p 40 40 40 40 48 48 l 145 145 146 146 q 26 26 29 29 39 34 m 181 181 208 208 q1 57.5 55.5 59.5 59.5 66.5 66.5 p 48 48 55 55 s 20 20 20 20 25 25 q 43 43 47 47 s1 27 27 34 34 38 38 q1 74 74 77 77 y 44 44 38.5 30.5 30.5 21.5 s 25 25 30 30 z 13.5 13.5 13.5 13.5 15.5 15.5 f = minimum distance required for coil removal f = minimum distance required for coil removal x1: minimum electrical clearance according to operational voltage and breaking capacity x1: minimum electrical clearance according to operational voltage and breaking capacity voltage in v 200 to 500 660 to 1000 voltage in v 200 to 500 660 to 1000 cr1f150 10 15 cr1f400 15 20 cr1f185 10 15 cr1f500 15 20 cr1f265 10 15 cr1f630 cr1f630 3 p 4 p a 309 389 g supplied 180 240 g min 100 150 g max 195 275 j1 61 81 q 60 60 q1 89 89 x1: minimum electrical clearance according to operational voltage and breaking capacity voltage in v x1 200 to 500 20 690 to 1000 30 j j1 b1 = = g1 g z = = y 3x?6.5 (1/4 inch mounting screws) l c = b = b 2 x1 x1 s1 q a ppq1 f m s f150 m8x25 f185 m8x25 f265 m10x35 c power terminal protection shroud . q1 a p q p f m 44.5 s 6xm10x35 g g1 23.5 j 120 = = 180 = = 8x8.5 (5/16 inch mounting screws) 155 = 304 = 197 255 280 x1 464 72 x1 180 = = j1 g 60.5 4x?10.5 (3/8 inch mounting screws) q1 a 80 80 q 264 181 64 40 6xm12x45 c power terminal protection shroud . q minimum distance required for coil removal.
cr1f/cr1b contacto rs and accessories magnetic latching contactors type cr1f ? mounting ? 2001-2004 schneider electric all rights reserved 240 01/04 magnetic latching contactors type cr1f - mounting dimensions shown in millimeters (mm x.0394 = inches) cr1f150 to f265 on panel on pre-slotted mounting plate am1pa , am1pb , am1pc on rails dz5mb at 120 mm mounting center c power terminal protection shroud. cr1f150 cr1f185 cr1f265 cr1f150 cr1f185 cr1f265 cr1f150 cr1f185 cr1f265 c 3p 171 181 213 c 3p 171 181 213 c 3p 171 181 213 4p 171 181 213 4p 171 181 213 4p 171 181 213 g 3p 80 80 96 g 3p 80 80 96 g 3p 80 80 96 4p 80 80 96 4p 80 80 96 4p 80 80 96 j 3p 26.5 29 44.5 4p 45 49 68.5 j1 3p 57 59.5 61.5 4p 75.5 79.5 85.5 cr1f150 to f650 on 2 notched uprights am1ec ??? q af1cd ??? or af1va ??? . f this upright am1ec200 is required when g2 or g3 is greater than 700 mm. cr1f150 cr1f185 cr1f265 cr1f400 cr1f500 cr1f630 c 3p 171 181 213 213 226 250 4p 171 181 213 213 226 250 g (m6) 3p 80 80 96 ? ? ? 4p 80 80 96 ? ? ? g1 (? 8.5) 3p ???8080? 4p ???80140? g2 (? 10.5) 3p ?????180 4p ?????240 3x 6.5 c j g = j1 = 110 = = c af1ea6 110 g dz5mf5 c g 110 120 15 c 25 120 ?10.5 am1ec200 af1cd081 + af1vc820 am1ec200 af1cd061+ af1va618 af1cd061 af1va618 m6 la9f100 af1cd101+ af1vc10 af1cd081+ af1vc820 ?8.5 m6 am1ec200 110 35 180 g == g af1va618 m6 g1 g2 g3
cr1f/cr1b contacto rs and accessories magnetic latching contactors type cr1f ? mounting 241 01/04 ? 2001-2004 schneider electric all rights reserved dimensions shown in millimeters (mm x .0394 = inches) reversing contactors 2 x cr1f150 to cr1f265 horizontally mounted reversing contactors 2 x cr1f400 to cr1f630 c except f630: 4 x ? 10.5. q except f630. 2 x cr1- a b g j j1 p1 2 x cr1- a b g g1 j j1 j2 j3 p1 f150 3p 345 170 80 71 57 71 f400 3p 446 206 80 170 157 64.5 67 19.5 107 4p 422 170 80 111 75.5 71 4p 542 206 80 170 157 112.5 67 67.5 107 f185 3p 357 174 80 78 59.5 78 f500 3p 485 238 80 170 156 84.5 66 39.5 112 4p 437 174 80 118 79.5 78 4p 595 238 140 230 156 79.5 66 34.5 112 f265 3p 425 203 96 109 61.5 100 f630 3p 636 304 180 ? 139 68.5 ? ? 137 4p 521 203 96 157 85.5 100 4p 796 304 240 ? 139 88.5 ? ? 137 110/120 = = = g1 j1 3x6.5 = = g1 = j1 j 3x6.5 a b p1 g g1 j3 120 = = 180 = = 8x?8.5 b g j1 j1 j2 j g1 j3 8x?8.5 p1 a
cr1f/cr1b contacto rs and accessories magnetic latching contactors type cr1f ? mounting ? 2001-2004 schneider electric all rights reserved 242 01/04 dimensions shown in millim eters (mm x .0394 = inches) changeover contactor pairs vertically mounted with mechanical interlock la9f ??? 2 contactors cr1f of identical or different ratings ( cr1f150 to cr1f630 ), see page 240. assembly a assembly b assembly c c mechanical interlock shaft. q for assembly of contactors with different ratings only. f 3 x ? 6.5 mm for cr1f150 to f265. p 3 x ? 6.5 mm for cr1f265. k mechanical interlock guide bracket. w 4 x ? 8.5 mm for cr1f400, f500 or 4 x ? 10.5 mm. assembly type ab c la9- ff4f fg4f fg4g fh4f fj4f fk4f fl4 f fh4g fj4g fk4g fl4g fh4h fj4h fk4h fl4h fj4j fk4j fl4 j fk4k fl4k fl4l g1 3p ? ? ? 96 80 80 180 96 80 80 180 96 80 80 180 80 80 180 80 180 180 4p ? ? ? 96 80 140 240 96 80 140 240 96 80 140 240 80 140 240 140 240 240 g2 3p??? ???????? 969696968080808080180 4p??? ???????? 96969696808080140140240 g3 3p 0 3 0 21 45 45 35 19 42 42 33 0 23 23 14 0 0 9 t 09 t 0 4p040 2726261723222213 0009 t 009 t 09 t 0 g4 3p??? ???????? 60606060838383838374 4p??? ???????? 83838383838383838374 g5 3p ? ? ? 60 83 83 74 60 83 83 74 60 83 83 74 83 83 74 83 74 74 4p ? ? ? 83 83 83 74 83 83 83 74 83 83 83 74 83 83 74 83 74 74 h min 200 210 220 240 250 270 310 250 250 270 310 250 260 280 330 260 280 325 300 345 380 max 310 300 310 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 h1 min 80 90 100 110 80 100 140 120 90 110 150 130 110 130 170 60 100 140 120 160 200 max 190 180 190 250 210 210 210 250 220 220 220 260 230 230 220 200 200 195 200 195 200 j1 3p 133 134 134 149.5 137 157 241 149.5 137 157 241 149.5 137 157 24 137 157 241 157 244 241 4p 145 146 146 164.5 185 212 321 164.5 185 212 321 164.5 185 212 321 185 212 321 212 321 321 j2 3p 133 133 134 183 133 183 133 134 134 134 134 142.5 149.5 149.5 149.5 137 137 137 157 157 241 4p 145 145 146 145 145 145 145 146 146 146 146 164.5 164.5 164.5 164.5 185 185 185 212 212 312 j3 3p48.55353 ???????? ?????????? 4p677373 ???????? ?????????? j4 3p48.55453 48.548.548.548.553535353 ?????????? 4p676973 6767676773737373 ?????????? t in this case g4 is larger than g5. f330 f265 h1 120 } f400 f500 f630 180 } f330 f265 120 } f400 f500 f630 180 } j1 g3 ? g2 g4 j2 12.5 9 = = ? g1 g5 12.5 h = = f330 f265 180 h1 120 } f400 f500 f630 180 } g1 g5 12.5 j1 g3 80 j4 = = ? h 9 j2 120 120 h1 80 j4 j2 j1 g3 == == 80 j3 h
cr1f/cr1b contacto rs and accessories magnetic latching contactors type cr1f ? mounting 243 01/04 ? 2001-2004 schneider electric all rights reserved dimensions shown in millimeters (mm x .0394 = inches) common side view single-pole, 2-pole, or 3-pole contactors 4-pole contactors cr1bl cr1bm cr1bp cr1br number of poles1234 1234 1234 1234 a 50 50 50 50 63 63 63 63 100 100 100 100 125 125 125 125 b 59 59 59 59 55 55 55 55 55 55 55 55 50 50 50 50 c 16 16 16 16 20 20 20 20 20 20 20 20 25 25 25 25 l 345 445 540 760 345 445 540 760 385 540 760 1065 445 635 885 1065 m 285 385 480 ? 285 385 480 ? 325 480 700 ? 385 575 825 ? m1 ???308???308???455???455 m2 ???392???392???550???550 n 121 121 121 121 125 125 125 125 125 125 125 125 130 130 130 130 p 100 100 100 100 100 100 100 100 150 150 150 150 195 195 195 195 q1 100 100 100 100 100 100 100 100 110 110 110 110 123 123 123 123 r 122 122 122 122 157 157 157 157 173 173 173 173 173 173 173 173 s 10 10 10 10 17 17 17 17 20 20 20 20 20 20 20 20 t 30 30 30 30 30 30 30 30 60 60 60 60 60 60 60 60 ? 9 9 9 9 11 11 11 11 11 11 11 11 11 11 11 11 electrical safety clearance values x1 and x2 are given for a breaking capacity of 10 in (3-phase ac current). 3-phase ac voltage cr1bl cr1bm cr1bp cr1br 380-415-440 v x1 100 100 150 200 x2 150 150 200 250 500 v x1 100 100 150 200 x2 150 150 220 250 600 v x1 150 150 200 200 x2 200 200 250 250 1000 v x1 200 200 200 250 x2 250 250 250 300 mechanical interlock for assembly of vertically mounted reversing contactors ez2lb0601 a t s t 260 r 290 185 n 85 cb c 365 44 p p q1 30 15 30 m l 15 350 350 p 30 15 30 m1 l p q1 51 m2 15 x2 x1 a = (ee112) 488 e = 600
cr1f/cr1b contacto rs and accessories magnetic latching contactors type cr1b ? adjustment characteristics ? 2001-2004 schneider electric all rights reserved 244 01/04 ac or dc supply with economy resi stor (and rectifier on ac supply) magnetic latching contactors type cr1b - adjustment characteristics complete pole adjustment of pick-up travel and pull-in travel n.o. pole adjustment n.c. automatic coil cut-out pole adjustment contactor type cr1bl cr1bm cr1bp cr1br electromagnet ( eb5kb50 ) pick-up travel (e) mm f 30 30 30 30 pull-in travel (e) mm f 10 10 10 10 coil wb1kb pull-in voltage v 0.75 vc 0.75 vc 0.75 vc ? drop-out voltage v 0.3 to 0.5 0.3 to 0.5 0.3 to 0.5 0.3 to 0.5 n.o. power pole (pa1) application force (f) to contact per pole dan / lb 30/67 30/67 30/67 c 30/67 q n.c. automatic coil cut-out pole (pr4) application force (f) dan / lb 0.9/2 0.9/2 0.9/2 0.9/2 opening gap (b) with electromagnet closed mm f 3.5 0.5 3.5 0.5 3.5 0.5 3.5 0.5 f millimeters x 0.394 = inches. c each pole has 2 contacts: the force must be applied evenly to each of these contacts. q each pole has 3 contacts: the force must be applied evenly to each of these contacts. e e moving circuit coil moving circuit return spring f moving contactct pull-in gap adjustment adjustment of application force pole spring fixed contact b f 1 2 3 4 5 fixed contact moving contact opening gap adjustment adjustment of application force pole s p rin g
cr1f/cr1b contacto rs and accessories magnetic latching contactors type cr1f ? schematics 245 01/04 ? 2001-2004 schneider electric all rights reserved magnetic latching contactors type cr1f - schematics nnn contactors type cr1f 3-pole cr1f ?? 33 4-pole cr1f ?? 34 front mounting add-on contact blocks - instantaneou s auxiliary contacts (references: pages 16 and 17) 1 n.o. la1dn10 1 n.c. la1dn01 1 n.o. + 1 n.c. la1dn11 2 n.o. la1dn20 2 n.c. la1dn02 2 n.o. + 2 n.c. la1dn22 1 n.o. + 3 n.c. la1dn13 4 n.o. la1dn40 4 n.c. la1dn04 2 n.o. + 2 n.c. of which 1 n.o. + 1 n.c. make-before-break la1dc22 3 n.o. + 1 n.c. la1dn31 front mounting add-on contact blocks - instantaneous auxiliary contacts conforming to standard en 50012 (references: pages 218 to 219) 1 n.o. + 1 n.c. la1dn11p 1 n.o. + 1 n.c. la1dn11g 1 n.o. + 1 n.c. la1dn11m 2 n.o. + 2 n.c. la1dn22p 2 n.o. + 2 n.c. la1dn22g 2 n.o. + 2 n.c. la1dn22m front mounting add-on contact blocks - dust and damp protected instantaneous auxiliary contacts (references: pages 218 to 219) 2 n.o. (24-50 v) la1dx20 2 n.o. (5-24 v) la1dy20 2 n.o. protected (24-50 v) 2 n.o. standard la1dz40 2 n.o. protected (24-50 v) + 1 n.o. + 1 n.c. standard la1dz31 front mounting add-on contact blocks - time delay auxiliary contacts (references: pages 218 to 219) ondelay 1 n.o. + 1 n.c. la2dt ? offdelay 1 n.o. + 1 n.c. la3dr ? n.c. ondelay + la2ds ? break-before-make n.o. contact 3-pole reversing contactors 2 x cr1f150 to cr1f630 4-pole reversing contactors 2 x cr1f1504 to cr1f6304 horizontally mounted vertically mounted contactors using 2 contactors of identical or different rating a1 a2 e1 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 a1 a2 e1 1/l1 t1/2 3/l2 t2/4 5/l3 t3/6 7/l4 t4/8 items in brackets refer to block mounted on right-hand side of contactor. 43 no 44 43/no (94) (93) items in brackets refer to block mounted on right-hand side of contactor. 42 41/nc (91) (92) 53/no 54 62 61/nc 63/no 64 53/no 54 52 51/nc 62 61/nc 72 71/nc 62 61/nc 83/no 84 53/no 54 72 71/nc 62 61/nc 53/no 54 82 81/nc 83/no 84 73/no 74 63/no 64 53/no 54 52 51/nc 62 61/nc 72 71/nc 82 81/nc 53/no 54 61/nc 62 87/no 88 75/nc 76 62 61/nc 83/no 84 73/no 74 53/no 54 22 21/nc 13/no 14 32 31/nc 43/no 44 22 21/nc 33/no 34 22 21/nc 32 31/nc 13/no 14 43/no 44 32 31/nc 42 41/nc 63/no 64 53/no 54 22 21/nc 32 31/nc 53/no 54 43/no 44 53/no 54 63/no 64 53/no 54 63/no 64 53/no 54 83/no 84 63/no 64 73/no 74 62 61/nc 53/no 54 83/no 84 73/no 74 55/nc 56 67/no 68 66 65/nc 57/no 58 67/no 68 55/nc 56 a1 a2 e1 a1 a2 e1 1 2 3 4 5 6 l1 l2 l3 1 2 3 4 5 6 u v w a1 a2 e1 a1 a2 e1 1 2 3 4 5 6 1n 1/l3 1/l2 1 2 3 4 5 6 l1 l2 l3 7 8 1/l1 2/l1 2/l2 2/l3 7 8 n 2n a1 a2 e1 1 2 3 4 1/l1 1/l2 1 2 3 4 2/l1 2/l2 5 6 1/l3 5 6 2/l3 a1 a2 e1 l3 l2 l1 a1 a2 e1 1 2 3 4 7 8 1/l1 1/l2 1n 1 2 3 4 7 8 2/l1 2/l2 2n 5 6 1/l3 5 6 2/l3 a1 a2 e1 l3 l2 l1 n
cr1f/cr1b contacto rs and accessories magnetic latching contactors type cr1f ? schematics ? 2001-2004 schneider electric all rights reserved 246 01/04 contactors type cr1b cr1b ? 31 ? 12 cr1b ? 31 ? 21 cr1b ? 31 ? 30 cr1b ? 32 ? 12 cr1b ? 32 ? 21 cr1b ? 32 ? 30 cr1b ? 33 ? 12 cr1b ? 33 ? 21 cr1b ? 33 ? 30 cr1b ? 34 ? 12 cr1b ? 34 ? 21 cr1b ? 34 ? 30 wiring schematics contactors cr1f and cr1b with thermal overload relay contactors cr1f contactors cr1b q : automatic coil cut-out contact zc4gm or pr4fb00 ?? s1: latching pushbutton s2: unlatching pushbutton coils for contactors cr1f pushbutton control schematic of internal circuit switch control warning: terminal a2 is common to both windings in all cases. a1 a2 a1 a2 a1 a2 a1 a2 a1 a2 a1 a2 a1 a2 a1 a2 a1 a2 a1 a2 a1 a2 a1 a2 2 4 6 l1 l2 l3 1 3 5 e km1 u w m 3 ac v 1 3 5 2 4 6 e f1 13 14 e km1 95 96 e f1 13 14 e s1 97 98 13 14 e s2 a1 e1 a2 e km1 e km1:1 e km1:5 96 95 13 14 2 13 14 km1 a1 a2 r1 97 98 r2 f1 21 km1 km1:1 km1:5 21 22 s2 ac ac dc dc a1 a2 cr1 e1 dc( ? )/ac dc(+)/ac ? a1 ? e1 ? a2 a1 a2 cr1 e1 cr1 dc( ? )/ac dc(+)/ac
catalog number index 247 01/04 ? 2001-2004 schneider electric all rights reserved a ab1g . . . . . . . . . . . . . . . . . . . . . . . 56, 72 ab1r . . . . . . . . . . . . . . . . . . . . . . . 56, 72 am1dp200 . . . . . . . . . . . . . . . . . . 56, 72 am1ed200 . . . . . . . . . . . . . . . . . . 56, 72 c cr1bl31 . . . . . . . . . . . . . . . . . . . . . . 230 cr1bl32 . . . . . . . . . . . . . . . . . . . . . . 230 cr1bl33 . . . . . . . . . . . . . . . . . . . . . . 230 cr1bl34 . . . . . . . . . . . . . . . . . . . . . . 230 cr1bm31 . . . . . . . . . . . . . . . . . . . . . 230 cr1bm32 . . . . . . . . . . . . . . . . . . . . . 230 cr1bm33 . . . . . . . . . . . . . . . . . . . . . 230 cr1bm34 . . . . . . . . . . . . . . . . . . . . . 230 cr1bp31 . . . . . . . . . . . . . . . . . . . . . 230 cr1bp32 . . . . . . . . . . . . . . . . . . . . . 230 cr1bp33 . . . . . . . . . . . . . . . . . . . . . 230 cr1bp34 . . . . . . . . . . . . . . . . . . . . . 230 cr1br31 . . . . . . . . . . . . . . . . . . . . . 230 cr1br32 . . . . . . . . . . . . . . . . . . . . . 230 cr1br33 . . . . . . . . . . . . . . . . . . . . . 230 cr1br34 . . . . . . . . . . . . . . . . . . . . . 230 cr1f150 . . . . . . . . . . . . . . . . . . . . . . 230 cr1f1504 . . . . . . . . . . . . . . . . . . . . . 230 cr1f185 . . . . . . . . . . . . . . . . . . 230, 233 cr1f1854 . . . . . . . . . . . . . . . . . 230, 233 cr1f265 . . . . . . . . . . . . . . . . . . 230, 233 cr1f2654 . . . . . . . . . . . . . . . . . 230, 233 cr1f400 . . . . . . . . . . . . . . . . . . 230, 233 cr1f4004 . . . . . . . . . . . . . . . . . 230, 233 cr1f500 . . . . . . . . . . . . . . . . . . 230, 233 cr1f5004 . . . . . . . . . . . . . . . . . 230, 233 cr1f630 . . . . . . . . . . . . . . . . . . 230, 233 cr1f6304 . . . . . . . . . . . . . . . . . 230, 233 d de1ds1 . . . . . . . . . . . . . . . . . . . . . . . 166 de1ds1a04. . . . . . . . . . . . . . . . . . . . 166 de1ds1a05. . . . . . . . . . . . . . . . . . . . 166 de1ds1a13. . . . . . . . . . . . . . . . . . . . 166 de1ds2 . . . . . . . . . . . . . . . . . . . . . . . 166 de1ds2a04. . . . . . . . . . . . . . . . . . . . 166 de1ds2a05. . . . . . . . . . . . . . . . . . . . 166 de1ds2a13. . . . . . . . . . . . . . . . . . . . 166 dr2sc0010 . . . . . . . . . . . . . . . . . . . 237 dr2sc0027 . . . . . . . . . . . . . . . . . . . 237 dr2sc0033 . . . . . . . . . . . . . . . . . . . 237 dr2sc0039 . . . . . . . . . . . . . . . 209, 237 dr2sc0047 . . . . . . . . . . . . . . . 209, 237 dr2sc0056 . . . . . . . . . . . . . . . . . . . 237 dr2sc0068 . . . . . . . . . . . . . . . . . . . 237 dr2sc0100 . . . . . . . . . . . . . . . . . . . 237 dr2sc0120 . . . . . . . . . . . . . . . . . . . 237 dr2sc0150 . . . . . . . . . . . . . . . . . . . 237 dr2sc0180 . . . . . . . . . . . . . . . . . . . 237 dr2sc0220 . . . . . . . . . . . . . . . 209, 237 dr2sc0270 . . . . . . . . . . . . . . . 209, 237 dr2sc0330 . . . . . . . . . . . . . . . 209, 237 dr2sc0390 . . . . . . . . . . . . . . . 209, 237 dr2sc0470 . . . . . . . . . . . . . . . . . . . 237 dr2sc0560 . . . . . . . . . . . . . . . . . . . 237 dr2sc0680 . . . . . . . . . . . . . . . . . . . 237 dr2sc1000 . . . . . . . . . . . . . . . 209, 237 dr2sc1200 . . . . . . . . . . . . . . . . . . . 209 dr2sc3300 . . . . . . . . . . . . . . . . . . . 209 dr2sc3900 . . . . . . . . . . . . . . . . . . . 209 dr2sc4700 . . . . . . . . . . . . . . . . . . . 209 dr5te1s . . . . . . . . . . . . . . . . . . . . . 237 dr5te1u . . . . . . . . . . . . . . . . . . . . . 237 dv1rc155 . . . . . . . . . . . . . . . . . . . . 238 dv1rc201 . . . . . . . . . . . . . . . . . . . . 238 dv1rt292 . . . . . . . . . . . . . . . . . . . . . 238 dx1ap25 . . . . . . . . . . . 56, 72, 134, 137 dx1ap26 . . . . . . . . . . . . . . . . . . . . . . .134 dz2ff1 . . . . . . . . . . . . . . . . . . . 198, 220 dz2ff6 . . . . . . . . . . . . . . . . . . . . . . . 198 dz2fg1 . . . . . . . . . . . . . . . . . . . . . . 198 dz2fg6 . . . . . . . . . . . . . . . . . . 198, 220 dz2fh1 . . . . . . . . . . . . . . . . . . . 198, 220 dz2fh6 . . . . . . . . . . . . . . . . . . . 198, 220 dz2fj1 . . . . . . . . . . . . . . . . . . . 198, 220 dz2fj6 . . . . . . . . . . . . . . . . . . . . . . . 198 dz2fk1 . . . . . . . . . . . . . . . . . . . 198, 220 dz2fk6 . . . . . . . . . . . . . . . . . . . . . . . 198 dz2fl . . . . . . . . . . . . . . . . . . . . . . . . 198 dz2fl1 . . . . . . . . . . . . . . . . . . . . . . . 220 dz2fl2 . . . . . . . . . . . . . . . . . . . . . . . 220 dz2fl3 . . . . . . . . . . . . . . . . . . . . . . . 220 dz2fl6 . . . . . . . . . . . . . . . . . . . . . . . 198 dz2fx6 . . . . . . . . . . . . . . . . . . . . . . . 198 dz3fa3 . . . . . . . . . . . . . . . . . . . . . . . 196 dz3ga3 . . . . . . . . . . . . . . . . . . . . . . 196 dz3ha3 . . . . . . . . . . . . . . . . . . . . . . . 196 dz3ja3 . . . . . . . . . . . . . . . . . . . . . . . 196 dzf2fx1 . . . . . . . . . . . . . . . . . . . . . . 198 e et1kb50 . . . . . . . . . . . . . . . . . . . . . . 238 ez2lb0601 . . . . . . . . . . . . . . . . . . . . 231 g gv1g09 . . . . . . . . . . . . . . . . . . . . . . . . 114 gv2g245 . . . . . . . . . . . . . . . . . . . . . . . 114 gv2g445 . . . . . . . . . . . . . . . . . . . . . . . 114 gv2me01 . . . . . . . . . . . . . . . . . . . . . 177 gv2me02 . . . . . . . . . . . . . . . . . . . . . 177 gv2me03 . . . . . . . . . . . . . . . . . . . . . 177 gv2me04 . . . . . . . . . . . . . . . . . . . . . 177 gv2me05 . . . . . . . . . . . . . . . . . . . . . 177 gv2me06 . . . . . . . . . . . . . . . . . . . . . 177 gv2me07 . . . . . . . . . . . . . . . . . . . . . 177 gv2me08 . . . . . . . . . . . . . . . . . . . . . 177 gv2me10 . . . . . . . . . . . . . . . . . . . . . 177 gv2me14 . . . . . . . . . . . . . . . . . . . . . 177 gv2me16 . . . . . . . . . . . . . . . . . . . . . 177 gv2me20 . . . . . . . . . . . . . . . . . . . . . 177 gv2me21 . . . . . . . . . . . . . . . . . . . . . 177 gv2me22 . . . . . . . . . . . . . . . . . . . . . 177 gv2me32 . . . . . . . . . . . . . . . . . . . . . 177 gv3a01 . . . . . . . . . . . . . . . . . . . . . . . 177 gv3a02 . . . . . . . . . . . . . . . . . . . . . . . 177 gv3a03 . . . . . . . . . . . . . . . . . . . . . . . 177 gv3a05 . . . . . . . . . . . . . . . . . . . . . . . 177 gv3a06 . . . . . . . . . . . . . . . . . . . . . . . 177 gv3a08 . . . . . . . . . . . . . . . . . . . . . . . 177 gv3a09 . . . . . . . . . . . . . . . . . . . . . . . 177 gv3a7 . . . . . . . . . . . . . . . . . . . . . . . . 177 gv3me06 . . . . . . . . . . . . . . . . . . . . . 177 l la . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 la1d . . . . . . . . . . . . . . . . . . . . . . . . . 231 la1dn11g . . . . . . . . . . . . . . . . . . . . 176 la1dx02 . . . . . . . . . . . . . . . . . . . . . . 107 la1dx20 . . . . . . . . . . 107, 195, 216, 245 la1dy20 . . . . . . . . . . 107, 195, 216, 245 la1dz31 . . . . . . . . . . 107, 195, 216, 245 la1dz40 . . . . . . . . . . 107, 195, 216, 245 la1kn02 . . . . . . . . . . . . . . . . . . . . 55, 72 la1kn023 . . . . . . . . . . . . . . . . . . . 55, 72 la1kn027 . . . . . . . . . . . . . . . . . . . 55, 72 la1kn02m . . . . . . . . . . . . . . . . . . 55, 72 la1kn04 . . . . . . . . . . . . . . . . . . . . . . . 55 la1kn043 . . . . . . . . . . . . . . . . . . . . . . 55 la1kn047 . . . . . . . . . . . . . . . . . . . . . . 55 la1kn11 . . . . . . . . . . . . . . . . . . . . 55, 72 la1kn113 . . . . . . . . . . . . . . . . . . . 55, 72 la1kn117 . . . . . . . . . . . . . . . . . . . 55, 72 la1kn11m . . . . . . . . . . . . . . . . . . 55, 72 la1kn11p . . . . . . . . . . . . . . . . . . . 55, 72 la1kn13 . . . . . . . . . . . . . . . . . . . . . . . 55 la1kn133 . . . . . . . . . . . . . . . . . . . . . . 55 la1kn137 . . . . . . . . . . . . . . . . . . . . . . 55 la1kn13m . . . . . . . . . . . . . . . . . . . . . 55 la1kn20 . . . . . . . . . . . . . . . . . . . . 55, 72 la1kn203 . . . . . . . . . . . . . . . . . . . 55, 72 la1kn207 . . . . . . . . . . . . . . . . . . . 55, 72 la1kn22 . . . . . . . . . . . . . . . . . . . . . . . 55 la1kn223 . . . . . . . . . . . . . . . . . . . . . . 55 la1kn227 . . . . . . . . . . . . . . . . . . . . . . 55 la1kn22m . . . . . . . . . . . . . . . . . . . . . 55 la1kn22p . . . . . . . . . . . . . . . . . . . . . . 55 la1kn31 . . . . . . . . . . . . . . . . . . . . . . . 55 la1kn313 . . . . . . . . . . . . . . . . . . . . . . 55 la1kn317 . . . . . . . . . . . . . . . . . . . . . . 55 la1kn31m . . . . . . . . . . . . . . . . . . . . . 55 la1kn40 . . . . . . . . . . . . . . . . . . . . . . . 55 la1kn403 . . . . . . . . . . . . . . . . . . . . . . 55 la1kn407 . . . . . . . . . . . . . . . . . . . . . . 55 la2kt2e . . . . . . . . . . . . . . . . . . . . 55, 72 la2kt2u . . . . . . . . . . . . . . . . . . . . 55, 72 la4da2e . . . . . . . . . . . . . . . . . . . . . . . 112 la4da2g . . . . . . . . . . . . . . . . . . . . . . . 112 la4da2u . . . . . . . . . . . . . . . . . . . . . . . 112 la4da2n . . . . . . . . . . . . . . . . . . . . . . . 112 la4db2b . . . . . . . . . . . . . . . . . . . . . . . 112 la4db2s . . . . . . . . . . . . . . . . . . . . . . . 112 la4db3b . . . . . . . . . . . . . . . . . . . . . . . 112 la4db3s . . . . . . . . . . . . . . . . . . . . . . . 112 la4dc1u . . . . . . . . . . . . . . . . . . . . . . . 112 la4dc3u . . . . . . . . . . . . . . . . . . . . . . . 112 la4de2e . . . . . . . . . . . . . . . . . . . . . . . 112 la4de2g . . . . . . . . . . . . . . . . . . . . . . . 112 la4de2u . . . . . . . . . . . . . . . . . . . . . . . 112 la4de3e . . . . . . . . . . . . . . . . . . . . . . . 112 la4de3g . . . . . . . . . . . . . . . . . . . . . . . 112 la4de3u . . . . . . . . . . . . . . . . . . . . . . 112 lad4rce . . . . . . . . . . . . . . . . . . . . . . 112 lad4rcu . . . . . . . . . . . . . . . . . . . . . . 112 lad4tb. . . . . . . . . . . . . . . . . . . . . . . . 112 lad4ts. . . . . . . . . . . . . . . . . . . . . . . . 112 lad4ve . . . . . . . . . . . . . . . . . . . . . . . 112 lad4vg . . . . . . . . . . . . . . . . . . . . . . . 112 lad4vu . . . . . . . . . . . . . . . . . . . . . . . 112 la4dfbq . . . . . . . . . . . . . . . . . . . . . . 111 la4dfb. . . . . . . . . . . . . . . . . . . . . . . . 111 la4dfe. . . . . . . . . . . . . . . . . . . . . . . . 111 la4dlb . . . . . . . . . . . . . . . . . . . . . . . . 111 la4dle . . . . . . . . . . . . . . . . . . . . . . . . 111 la4dmk . . . . . . . . . . . . . . . . . . . . . . . 111 la4dmu . . . . . . . . . . . . . . . . . . . . . . . 111 la4dt0u . . . . . . . . . . . . . . . . . . . . . . 111 la4dt2u . . . . . . . . . . . . . . . . . . . . . . 111 la4dt4u . . . . . . . . . . . . . . . . . . . . . . 111 la4dwb . . . . . . . . . . . . . . . . . . . . . . . 111 la4frce . . . . . . . . . . . . . . . . . . . . . . 196 la4frcf . . . . . . . . . . . . . . . . . . . . . . 196 la4frcp . . . . . . . . . . . . . . . . . . . . . . 196 la4frcv . . . . . . . . . . . . . . . . . . . . . . 196 la4frve . . . . . . . . . . . . . . . . . . . . . . 196 la4frvf. . . . . . . . . . . . . . . . . . . . . . . 196 la4frvp . . . . . . . . . . . . . . . . . . . . . . 196 la4frvv . . . . . . . . . . . . . . . . . . . . . . 196 la4fte . . . . . . . . . . . . . . . . . . . . . . . . 196 la4ftf . . . . . . . . . . . . . . . . . . . . . . . . 196 la4ftp . . . . . . . . . . . . . . . . . . . . . . . . 196 la4ftv . . . . . . . . . . . . . . . . . . . . . . . . 196 la4fde. . . . . . . . . . . . . . . . . . . . . . . . 196 la4fdf . . . . . . . . . . . . . . . . . . . . . . . . 196 la4fdp. . . . . . . . . . . . . . . . . . . . . . . . 196 la4fdv . . . . . . . . . . . . . . . . . . . . . . . . 196 la4ka1u . . . . . . . . . . . . . . . . . . . . . . . 56 la4kc1b . . . . . . . . . . . . . . . . . . . . . . . 56 la4kc1e . . . . . . . . . . . . . . . . . . . . . . . 56 la4ke1b . . . . . . . . . . . . . . . . . . . . . . . 56 la4ke1e . . . . . . . . . . . . . . . . . . . . . . . 56 la4ke1fc . . . . . . . . . . . . . . . . . . . . . . 56 la4ke1ug . . . . . . . . . . . . . . . . . . . . . . 56 la4spx. . . . . . . . . . . . . . . . . . . . . . . . 108 la5d1158031 . . . . . . . . . . . . . . . . . . . 114 la5d150803 . . . . . . . . . . . . . . . . . . . . 114 la5d115804 . . . . . . . . . . . . . . . . . . . . 114 la5d11550 . . . . . . . . . . . . . . . . . . . . . 114 la5d15050b . . . . . . . . . . . . . . . . . . . . 114 la5d115450b . . . . . . . . . . . . . . . . . . . 114 la5f115450 . . . . . . . . . . . . . . . . . . . . 199 la5f11550 . . . . . . . . . . . . . . . . . . . . . 199 la5f150450 . . . . . . . . . . . . . . . . 199, 238 la5f15050 . . . . . . . . . . . . . . . . . 199, 238 la5f185450 . . . . . . . . . . . . . . . . 199, 238 la5f18550 . . . . . . . . . . . . . . . . . 199, 238 la5f225450 . . . . . . . . . . . . . . . . . . . . 199 la5f22550 . . . . . . . . . . . . . . . . . . . . . 199 la5f265450 . . . . . . . . . . . . . . . . 199, 238 la5f26550 . . . . . . . . . . . . . . . . . 199, 238 la5f330450 . . . . . . . . . . . . . . . . . . . . 199 la5f33050 . . . . . . . . . . . . . . . . . . . . . 199 la5f400250 . . . . . . . . . . . . . . . . . . . . 199 la5f400450 . . . . . . . . . . . . . . . . 199, 238 la5f40050 . . . . . . . . . . . . . . . . . 199, 238 la5f400802 . . . . . . . . . . . . . . . . . . . . 199 la5f400803 . . . . . . . . . . . . . . . . 199, 238 la5f400804 . . . . . . . . . . . . . . . . 199, 238 la5f500250 . . . . . . . . . . . . . . . . . . . . 199 la5f500450 . . . . . . . . . . . . . . . . 199, 238 la5f50050 . . . . . . . . . . . . . . . . . 199, 238 la5f500802 . . . . . . . . . . . . . . . . . . . . 199 la5f500803 . . . . . . . . . . . . . . . . 199, 238 la5f500804 . . . . . . . . . . . . . . . . 199, 238 la5f630250 . . . . . . . . . . . . . . . . . . . . 199 la5f630450 . . . . . . . . . . . . . . . . 199, 238 la5f63050 . . . . . . . . . . . . . . . . . 199, 238 la5f630802 . . . . . . . . . . . . . . . . . . . . 199 la5f630803 . . . . . . . . . . . . . . . . 199, 238 la5f630804 . . . . . . . . . . . . . . . . 199, 238 la5f780150 . . . . . . . . . . . . . . . . . . . . 199 la5f780801 . . . . . . . . . . . . . . . . . . . . 199 la5f780803 . . . . . . . . . . . . . . . . . . . . 199 la5f780804 . . . . . . . . . . . . . . . . . . . . 199 la5f80050 . . . . . . . . . . . . . . . . . . . . . 199 la5f800803 . . . . . . . . . . . . . . . . . . . . 199 la5ff431 . . . . . . . . . . . . . . . . . 199, 238 la5ff441 . . . . . . . . . . . . . . . . . 199, 238 la5fg431 . . . . . . . . . . . . . . . . . 199, 238 la5fg441 . . . . . . . . . . . . . . . . . 199, 238 la5fh431 . . . . . . . . . . . . . . . . . 199, 238 la5fh441 . . . . . . . . . . . . . . . . . 199, 238 la6dk10 . . . . . . . . . . . . . . . . . . . . . . .108 la6dk20 . . . . . . . . . . . . . . . . . . . . . . .108 la7d03 . . . . . . . . . . . . . . . . . . . .137, 221 la7d1020 . . . . . . . . . . . . . . . . . .137, 221 la7d1064 . . . . . . . . . . . . . . . . . . . . . . 137 la7d2064 . . . . . . . . . . . . . . . . . . . . . . 137 la7d305 . . . . . . . . . . . . . . . . . . .137, 221 la7d3064 . . . . . . . . . . . . . . . . . . . . . .137 la7d3058 . . . . . . . . . . . . . . . . . . . . . .137 la7d901 . . . . . . . . . . . . . . . . . . .137, 221 la7d902 . . . . . . . . . . . . . . . . . . . . . . .137 la7d903 . . . . . . . . . . . . . . . . . . .137, 221 la7f401 . . . . . . . . . . . . . . . . . . .197, 221 la7f402 . . . . . . . . . . . . . . . . . . .197, 221 la7f403 . . . . . . . . . . . . . . . . . . .197, 221 la7f404 . . . . . . . . . . . . . . . . . . .197, 221 la7f405 . . . . . . . . . . . . . . . . . . .197, 221 la7f406 . . . . . . . . . . . . . . . . . . .197, 221 la7f407 . . . . . . . . . . . . . . . . . . . . . . .221 la7f701 . . . . . . . . . . . . . . . . . . . . . . .221 la7f702 . . . . . . . . . . . . . . . . . . . . . . .221 la7f703 . . . . . . . . . . . . . . . . . . . . . . .221 la7f901 . . . . . . . . . . . . . . . . . . . . . . .221 la7f902 . . . . . . . . . . . . . . . . . . . . . . .221 la7k0064 . . . . . . . . . . . . . . . . . . . . . . .63 la9aadis3 . . . . . . . . . . . . . . . . . . . . .155 la9aadis4 . . . . . . . . . . . . . . . . . . . . .155 la9aadis5 . . . . . . . . . . . . . . . . . . . . .155 la9aadis7 . . . . . . . . . . . . . . . . . . . . .155 la9b103 . . . . . . . . . . . . . . . . . . . . . . .231 la9ca06dt. . . . . . . . . . . . . . . . . . . . .155 la9ca06et. . . . . . . . . . . . . . . . . . . . .155 la9ca06ft . . . . . . . . . . . . . . . . . . . . .155 la9ca06gt . . . . . . . . . . . . . . . . . . . .155 la9ca06ht. . . . . . . . . . . . . . . . . . . . .155 la9ca06io . . . . . . . . . . . . . . . . . . . . .155 la9ca06jt . . . . . . . . . . . . . . . . . . . . .155 la9ca06lt . . . . . . . . . . . . . . . . . . . . .155 la9ca06nt. . . . . . . . . . . . . . . . . . . . .155 la9ca06st. . . . . . . . . . . . . . . . . . . . .155 la9ca06ut. . . . . . . . . . . . . . . . . . . . .155 la9ca06vt. . . . . . . . . . . . . . . . . . . . .155 la9ca06wt . . . . . . . . . . . . . . . . . . . .155 la9ca16st. . . . . . . . . . . . . . . . . . . . .155 la9ca16ut. . . . . . . . . . . . . . . . . . . . .155 la9ca16vt. . . . . . . . . . . . . . . . . . . . .155 la9ca16wt . . . . . . . . . . . . . . . . . . . .155 la9d09907 . . . . . . . . . . . . . . . . . . . . .160 la9d09966 . . . . . . . . . . . . . . . . . . . . . 113 la9d09980 . . . . . . . . . . . . . . . . . . . . .196 la9d09981 . . . . . . . . . . . . . . . . . . . . .196 la9d91 . . . . . . . . . . . . . . . . . . . . . . . .137 la9d11502 . . . . . . . . . . . . . . . . . . . . . .98 la9d115503b . . . . . . . . . . . . . . . . . . . 113 la9d115504 . . . . . . . . . . . . . . . . . . . . 113 la9d115603b . . . . . . . . . . . . . . . . . . . 113 la9d115604 . . . . . . . . . . . . . . . . . . . . 113 la9d115703 . . . . . . . . . . . . . . . . . . . . 113 la9d11569 . . . . . . . . . . . . . . . . . . . . . .98 la9d115704 . . . . . . . . . . . . . . . . . . . .113 la9d1260 . . . . . . . . . . . . . . . . . . . . . . 113 la9d1261 . . . . . . . . . . . . . . . . . . . . . . 113 la9d1263 . . . . . . . . . . . . . . . . . . . . . . 113 la9d12974 . . . . . . . . . . . . . . . . . . . . .149 la9d2561 . . . . . . . . . . . . . . . . . . . . . .113 la9d11569 . . . . . . . . . . . . . . . . . . . . . .98 la9d3260 . . . . . . . . . . . . . . . . . . . . . .113 la9d32974 . . . . . . . . . . . . . . . . . . . . .149 la9d4002 . . . . . . . . . . . . . . . . . . . . . . .98 la9d40961 . . . . . . . . . . . . . . . . . . . . . 113 la9d40963 . . . . . . . . . . . . . . . . . . . . . 113 la9d4017 . . . . . . . . . . . . . . . . . . . . . .149 la9d40961 . . . . . . . . . . . . . . . . . . . . . 113 la9d40963 . . . . . . . . . . . . . . . . . . . . . 113 la9d40973 . . . . . . . . . . . . . . . . . . . . .149 la9d5017 . . . . . . . . . . . . . . . . . . . . . .149 la9d50978 . . . . . . . . . . . . . . . . . . . . . .98 la9d511 . . . . . . . . . . . . . . . . . . . . . . .114 la9d6567 . . . . . . . . . . . . . . . . . . . . . . 113 la9d6569 . . . . . . . . . . . . . . . . . . . . . . .98 la9d730 . . . . . . . . . . . . . . . . . . . . . . .114 la9d8002 . . . . . . . . . . . . . . . . . . . . . . .98 la9d8017 . . . . . . . . . . . . . . . . . . . . . .149 la9d8067 . . . . . . . . . . . . . . . . . . . . . .113 la9d8069 . . . . . . . . . . . . . . . . . . . . . . .98 la9d80961 . . . . . . . . . . . . . . . . . . . . . 113 la9d80962 . . . . . . . . . . . . . . . . . . . . . 113 la9d80963 . . . . . . . . . . . . . . . . . . . . . 113 la9d80973 . . . . . . . . . . . . . . . . . . . . .149 la9d80978 . . . . . . . . . . . . . . . . . . . . . .98 la9d90 . . . . . . . . . . . . . . . . . . . . . .56, 72
catalog number index ? 2001-2004 schneider electric all rights reserved 248 01/04 la9d901. . . . . . . . . . . . . . . . . . . . . . . .114 la9d92 . . . . . . . . . . . . . . . . . . . . . . . .114 la9d93. . . . . . . . . . . . . . . . . . . . . . . . .114 la9d941 . . . . . . . . . . . . . . . . . . . . . . .114 la9d973 . . . . . . . . . . . . . . . . . . . . 56, 72 la9d9pvgv . . . . . . . . . . . . . . . . . . . . 98 la9e01 . . . . . . . . . . . . . . . . . . . . . 56, 72 la9e02 . . . . . . . . . . . . . . . . . . . . . 56, 72 la9f . . . . . . . . . . . . . . . . . . . . . . . . . 233 la9f103 . . . . . . . . . . . . . . 137, 198, 231 la9f15076 . . . . . . . . . . . . . . . . . . . . 191 la9f15077 . . . . . . . . . . . . . . . . . . . . 193 la9f15082 . . . . . . . . . . . . . . . . . . . . 191 la9f22576 . . . . . . . . . . . . . . . . . . . . 191 la9f22577 . . . . . . . . . . . . . . . . . . . . 193 la9f22582 . . . . . . . . . . . . . . . . . . . . 191 la9f701 . . . . . . . . . . . . . . . . . . 198, 221 la9f702 . . . . . . . . . . . . . . . . . . 198, 221 la9f703 . . . . . . . . . . . . . . . . . . 198, 221 la9f704 . . . . . . . . . . . . . . . . . . . . . . 198 la9f705 . . . . . . . . . . . . . . . . . . . . . . 221 la9f706 . . . . . . . . . . . . . . . . . . . . . . 198 la9f707 . . . . . . . . . . . . . . . . . . . . . . 198 la9f708 . . . . . . . . . . . . . . . . . . . . . . 198 la9f709 . . . . . . . . . . . . . . . . . . . . . . 198 la9f980 . . . . . . . . . . . . . . . . . . . . . . 196 la9ff4f . . . . . . . . . . . . . . 191, 193, 233 la9ff601 . . . . . . . . . . . . . . . . . . . . . 196 la9ff602 . . . . . . . . . . . . . . . . . . . . . 196 la9ff970 . . . . . . . . . . . . . 191, 193, 233 la9ff976 . . . . . . . . . . . . . . . . . 191, 233 la9ff977 . . . . . . . . . . . . . . . . . 193, 233 la9ff979 . . . . . . . . . . . . . . . . . . . . . 197 la9ff980 . . . . . . . . . . . . . . . . . . . . . 197 la9ff981 . . . . . . . . . . . . . . . . . . . . . 197 la9ff982 . . . . . . . . . . . . . . . . . . . . . 191 la9fg4f . . . . . . . . . . . . . . . . . . 193, 233 la9fg4g . . . . . . . . . . . . . 191, 193, 233 la9fg601 . . . . . . . . . . . . . . . . . . . . . 196 la9fg602 . . . . . . . . . . . . . . . . . . . . . 196 la9fg970 . . . . . . . . . . . . . 191, 193, 233 la9fg976 . . . . . . . . . . . . . . . . . 191, 233 la9fg977 . . . . . . . . . . . . . . . . . 193, 233 la9fg979 . . . . . . . . . . . . . . . . . . . . . 197 la9fg980 . . . . . . . . . . . . . . . . . . . . . 197 la9fg981 . . . . . . . . . . . . . . . . . . . . . 197 la9fg982 . . . . . . . . . . . . . . . . . . . . . 193 la9fh4f . . . . . . . . . . . . . . . . . . 193, 233 la9fh4g . . . . . . . . . . . . . . . . . . 193, 233 la9fh4h . . . . . . . . . . . . . . 191, 193, 233 la9fh601 . . . . . . . . . . . . . . . . . . . . . 196 la9fh602 . . . . . . . . . . . . . . . . . . . . . 196 la9fh976 . . . . . . . . . . . . . . . . . 191, 233 la9fh977 . . . . . . . . . . . . . . . . . 193, 233 la9fh982 . . . . . . . . . . . . . . . . . . . . . 191 la9fj4f . . . . . . . . . . . . . . . . . . 193, 233 la9fj4g . . . . . . . . . . . . . . . . . . 193, 233 la9fj4h . . . . . . . . . . . . . . . . . . 193, 233 la9fj4j . . . . . . . . . . . . . . 191, 193, 233 la9fj970 . . . . . . . . . . . . . 191, 193, 233 la9fj976 . . . . . . . . . . . . . . . . . 191, 233 la9fj977 . . . . . . . . . . . . . . . . . 193, 233 la9fj979 . . . . . . . . . . . . . . . . . . . . . 197 la9fj980 . . . . . . . . . . . . . . . . . . . . . 197 la9fj981 . . . . . . . . . . . . . . . . . . . . . 197 la9fj982 . . . . . . . . . . . . . . . . . . . . . 191 la9fk4f . . . . . . . . . . . . . . . . . . 193, 233 la9fk4g . . . . . . . . . . . . . . . . . . 193, 233 la9fk4h . . . . . . . . . . . . . . . . . . 193, 233 la9fk4j . . . . . . . . . . . . . . . . . . 193, 233 la9fk4k . . . . . . . . . . . . . . 191, 193, 233 la9fk601 . . . . . . . . . . . . . . . . . . . . . 196 la9fk602 . . . . . . . . . . . . . . . . . . . . . 196 la9fk976 . . . . . . . . . . . . . . . . . 191, 233 la9fk977 . . . . . . . . . . . . . . . . . 193, 233 la9fk979 . . . . . . . . . . . . . . . . . . . . . 197 la9fk980 . . . . . . . . . . . . . . . . . . . . . 197 la9fk981 . . . . . . . . . . . . . . . . . . . . . 197 la9fk982 . . . . . . . . . . . . . . . . . . . . . 191 la9fl4f . . . . . . . . . . . . . . . . . . 193, 233 la9fl4g . . . . . . . . . . . . . . . . . . 193, 233 la9fl4h . . . . . . . . . . . . . . . . . . 193, 233 la9fl4j . . . . . . . . . . . . . . . . . . 193, 233 la9fl4k . . . . . . . . . . . . . . . . . . 193, 233 la9fl4l . . . . . . . . . . . . . . 191, 193, 233 la9fl601 . . . . . . . . . . . . . . . . . . . . . 196 la9fl602 . . . . . . . . . . . . . . . . . . . . . 196 la9fl970 . . . . . . . . . . . . . 191, 193, 233 la9fl976 . . . . . . . . . . . . . . . . . 191, 233 la9fl977 . . . . . . . . . . . . . . . . . 193, 233 la9fl979 . . . . . . . . . . . . . . . . . . . . . 197 la9fl980 . . . . . . . . . . . . . . . . . . . . . . 197 la9fl981 . . . . . . . . . . . . . . . . . . . . . . 197 la9fl982 . . . . . . . . . . . . . . . . . . . . . . 191 la9fx970 . . . . . . . . . . . . . . . . . . . . . 191 la9fx971u . . . . . . . . . . . . . . . . . . . . 193 la9k0969 . . . . . . . . . . . . . . . . . . . . 56, 72 la9k0970 . . . . . . . . . . . . . . . . . . . . 56, 72 la9p5152 . . . . . . . . . . . . . . . . . . . . . . 114 la9td32 . . . . . . . . . . . . . . . . . . . . . . . 155 la9td80 . . . . . . . . . . . . . . . . . . . . . . . 155 lad21 . . . . . . . . . . . . . . . . . . . . . . . . . 114 lad22 . . . . . . . . . . . . . . . . . . . . . . . . . 114 lad23 . . . . . . . . . . . . . . . . . . . . . . . . . 114 lad24 . . . . . . . . . . . . . . . . . . . . . . . . . 114 lad3pvpg . . . . . . . . . . . . . . . . . . . . . 98 lad4 . . . . . . . . . . . . . . . . . . . . . . . . . . 112 lad4bb. . . . . . . . . . . . . . . . 109, 111, 114 lad4bbve . . . . . . . . . . . . . . . . . . . . . 114 lad4bbvg . . . . . . . . . . . . . . . . . . . . . 114 lad4bbvu . . . . . . . . . . . . . . . . . . . . . 114 lad6k10 . . . . . . . . . . . . . . . . . . . . . . . 108 lad8n11 . . . . . . . . . . . . . . . . . . 107, 176 lad8n20 . . . . . . . . . . . . . . . . . . 107, 176 lad8n02. . . . . . . . . . . . . . . . . . . . . . . 107 lad7c. . . . . . . . . . . . . . . . . . . . . . . . . 137 lad7c2. . . . . . . . . . . . . . . . . . . . . . . . 137 lad7b10 . . . . . . . . . . . . . . . . . . . . . . . 137 lad7b105 . . . . . . . . . . . . . . . . . . . . . 137 lad7305 . . . . . . . . . . . . . . . . . . . . . 137 lad703 . . . . . . . . . . . . . . . . . . . . . . . 137 lad8 . . . . . . . . . . . . . . . . . . . . . . . . . 100 lad9091 . . . . . . . . . . . . . . . . . . . . . . 165 lad9092 . . . . . . . . . . . . . . . . . . . . . . 165 lad91217 . . . . . . . . . . . . . . . . . . . . . 149 lad912gvq . . . . . . . . . . . . . . . . . . . . 149 lad91810 . . . . . . . . . . . . . . . . . . . . . . 165 lad93217 . . . . . . . . . . . . . . . . . . . . . 149 lad96060 . . . . . . . . . . . . . . . . . . . . . . 113 lad9p3 . . . . . . . . . . . . . . . . . . . . . . . . 113 lad9ect1 . . . . . . . . . . . . . . . . . . . . . 114 lad9et1 . . . . . . . . . . . . . . . . . . . . . . 114 lad9et2. . . . . . . . . . . . . . . . . . . . . . . 114 lad9et3. . . . . . . . . . . . . . . . . . . . . . . 114 lad9et4. . . . . . . . . . . . . . . . . . . . . . . 114 lad9r1 . . . . . . . . . . . . . . . . . . . . . . . . 98 lad9r1v . . . . . . . . . . . . . . . . . . . . . . . 98 lad9t4 . . . . . . . . . . . . . . . . . . . . . . . . 165 lad9v1 . . . . . . . . . . . . . . . . . . . . . . . . 98 lad9v10 . . . . . . . . . . . . . . . . . . . . . . . 98 lad9v11 . . . . . . . . . . . . . . . . . . . . . . . 98 lad9v12 . . . . . . . . . . . . . . . . . . . . . . . 98 lad9v13 . . . . . . . . . . . . . . . . . . . . . . . 98 lad9v2 . . . . . . . . . . . . . . . . . . . . . . . . 98 lad9v5 . . . . . . . . . . . . . . . . . . . . . . . . 98 lad9v6 . . . . . . . . . . . . . . . . . . . . . . . . 98 ladc22 . . . . . . . . . . . . . . . 107, 176, 195 ladlvrt. . . . . . . . . . . . . . . . . . . . . . . 109 ladn01 . . . . . . . . . . . . . . . 107, 176, 195 ladn02 . . . . . . . . . . . . . . . 107, 176, 195 ladn04 . . . . . . . . . . . . . . . 107, 176, 195 ladn10 . . . . . . . . . . . . . . . 107, 176, 195 ladn11 . . . . . . . . . . . . . . . 107, 176, 195 ladn11g . . . . . . . . . . . . . . 107, 176, 195 ladn11p . . . . . . . . . . . . . . 107, 176, 195 ladn13 . . . . . . . . . . . . . . . 107, 176, 195 ladn20 . . . . . . . . . . . . . . . 107, 176, 195 ladn22 . . . . . . . . . . . . . . . 107, 176, 195 ladn22g . . . . . . . . . . . . . . 107, 176, 195 ladn22p . . . . . . . . . . . . . . 107, 176, 195 ladn31 . . . . . . . . . . . . . . . 107, 176, 195 ladn31g . . . . . . . . . . . . . . . . . . . . . . 176 ladn31p . . . . . . . . . . . . . . . . . . . . . . 176 ladn40 . . . . . . . . . . . . . . . 107, 176, 195 ladr0 . . . . . . . . . . . . . . . . 108, 176, 195 ladr2 . . . . . . . . . . . . . . . . 108, 176, 195 ladr4 . . . . . . . . . . . . . . . . 108, 176, 195 lads2 . . . . . . . . . . . . . . . . 108, 176, 195 ladt0 . . . . . . . . . . . . . . . . 108, 176, 195 ladt2 . . . . . . . . . . . . . . . . 108, 176, 195 ladt4 . . . . . . . . . . . . . . . . 108, 176, 195 lc1d09 . . . . . . . . . 88, 91, 149, 175, 176 lc1d093 . . . . . . . . . . . . . . . . . . . . 89, 91 lc1d096 . . . . . . . . . . . . . . . . 90, 92, 175 lc1d098 . . . . . . . . . . . . . . . . . . . . . . . 91 lc1d0983 . . . . . . . . . . . . . . . . . . . . . . 91 lc1d0986 . . . . . . . . . . . . . . . . . . . . . . 92 lc1d099 . . . . . . . . . . . . . . . . . . . . . . 175 lc1d115 . . . . . . . . . . . . 88, 91, 149, 175 lc1d115004 . . . . . . . . . . . . . . . . . . . . 91 lc1d1150046 . . . . . . . . . . . . . . . . . . . 92 lc1d1156 . . . . . . . . . . . . . . . 90, 92, 175 lc1d12 . . . . . . . . . 88, 91, 149, 175, 176 lc1d123 . . . . . . . . . . . . . . . . . . . . 89, 91 lc1d126 . . . . . . . . . . . . . . . . 90, 92, 175 lc1d128 . . . . . . . . . . . . . . . . . . . 91, 175 lc1d1283 . . . . . . . . . . . . . . . . . . . . . . 91 lc1d1286 . . . . . . . . . . . . . . . . . . . . . . 92 lc1d129 . . . . . . . . . . . . . . . . . . . . . . 175 lc1d150 . . . . . . . . . . . . 88, 91, 149, 175 lc1d1506 . . . . . . . . . . . . . . . 90, 92, 175 lc1d18 . . . . . . . . . 88, 91, 149, 175, 176 lc1d183 . . . . . . . . . . . . . . . . . . . . 89, 91 lc1d186 . . . . . . . . . . . . . . . . 90, 92, 175 lc1d25 . . . . . . . . . . . . . 88, 91, 175, 176 lc1d253 . . . . . . . . . . . . . . . . . . . . 89, 91 lc1d256 . . . . . . . . . . . . . . . . 90, 92, 175 lc1d258 . . . . . . . . . . . . . . . . . . . 91, 175 lc1d2583 . . . . . . . . . . . . . . . . . . . . . . 91 lc1d2586 . . . . . . . . . . . . . . . . . . 92, 175 lc1d32 . . . . . . . . . . . . . 88, 91, 149, 175 lc1d323 . . . . . . . . . . . . . . . . . . . . . . . 89 lc1d326 . . . . . . . . . . . . . . . . 90, 92, 175 lc1d38 . . . . . . . . . . . . . . . . . 88, 91, 175 lc1d383 . . . . . . . . . . . . . . . . . . . . . . . 89 lc1d386 . . . . . . . . . . . . . . . . 90, 92, 175 lc1d40 . . . . . . . . . . . . . 88, 91, 149, 175 lc1d40004 . . . . . . . . . . . . . . . . . . . . . 91 lc1d400046 . . . . . . . . . . . . . . . . . . . . 92 lc1d40008 . . . . . . . . . . . . . . . . . . . . . 91 lc1d400086 . . . . . . . . . . . . . . . . . . . . 92 lc1d406 . . . . . . . . . . . . . . . . 90, 92, 175 lc1d50 . . . . . . . . . . . . . 88, 91, 149, 175 lc1d506 . . . . . . . . . . . . . . . . . . . 90, 175 lc1d6le7 . . . . . . . . . . . . . . . . . . . . . 118 lc1d65 . . . . . . . . . . . . . . . . . 88, 91, 175 lc1d65004 . . . . . . . . . . . . . . . . . . . . . 91 lc1d800046 . . . . . . . . . . . . . . . . . . . . 92 lc1d65008 . . . . . . . . . . . . . . . . . . . . . 91 lc1d800086 . . . . . . . . . . . . . . . . . . . . 92 lc1d806 . . . . . . . . . . . . . . . . 90, 92, 175 lc1d80 . . . . . . . . . . . . . 88, 91, 149, 175 lc1d80004 . . . . . . . . . . . . . . . . . . . . . 91 lc1d800046 . . . . . . . . . . . . . . . . . . . . 92 lc1d80008 . . . . . . . . . . . . . . . . . . . . . 91 lc1d800086 . . . . . . . . . . . . . . . . . . . . 92 lc1d806 . . . . . . . . . . . . . . . . 90, 92, 175 lc1d95 . . . . . . . . . . . . . . 88, 91, 92, 175 lc1d956 . . . . . . . . . . . . . . . . . . . 90, 175 lc1dfk02 . . . . . . . . . . . . . . . . . . . . 142 lc1dfk11 . . . . . . . . . . . . . . . . . . . . 142 lc1dgk02 . . . . . . . . . . . . . . . . . . . . 142 lc1dgk11 . . . . . . . . . . . . . . . . . . . . 142 lc1dlk02 . . . . . . . . . . . . . . . . . . . . . 142 lc1dlk11 . . . . . . . . . . . . . . . . . . . . . 142 lc1dmk02 . . . . . . . . . . . . . . . . . . . . 142 lc1dmk11 . . . . . . . . . . . . . . . . . . . . 142 lc1dpk12 . . . . . . . . . . . . . . . . . . . . 142 lc1dt188 . . . . . . . . . . . . . . . . . . . . . . 91 lc1dt1886 . . . . . . . . . . . . . . . . . . . . . 92 lc1dt20 . . . . . . . . . . . . . . . . . . . . . . . 91 lc1dt203 . . . . . . . . . . . . . . . . . . . . . . 91 lc1dt206 . . . . . . . . . . . . . . . . . . . . . . 92 lc1dt25 . . . . . . . . . . . . . . . . . . . 91, 175 lc1dt253 . . . . . . . . . . . . . . . . . . . . . . 91 lc1dt256 . . . . . . . . . . . . . . . . . . 92, 175 lc1dt2583 . . . . . . . . . . . . . . . . . . . . . 91 lc1dt32 . . . . . . . . . . . . . . . . . . . . . . . 91 lc1dt323 . . . . . . . . . . . . . . . . . . . . . . 91 lc1dt326 . . . . . . . . . . . . . . . . . . . . . . 92 lc1dt40 . . . . . . . . . . . . . . . . . . . 91, 175 lc1dt403 . . . . . . . . . . . . . . . . . . . . . . 91 lc1dt406 . . . . . . . . . . . . . . . . . . 92, 175 lc1dtk12 . . . . . . . . . . . . . . . . . . . . 142 lc1dwk12 . . . . . . . . . . . . . . . . . . . . 142 lc1f115 . . . . . . . . . . . . . . . . . . 188, 189 lc1f1154 . . . . . . . . . . . . . . . . . 188, 189 lc1f150 . . . . . . . . . . . . . . . . . . 188, 189 lc1f1504 . . . . . . . . . . . . . . . . . 188, 189 lc1f185 . . . . . . . . . . . . . . . . . . 188, 189 lc1f1854 . . . . . . . . . . . . . . . . . 188, 189 lc1f225 . . . . . . . . . . . . . . . . . . 188, 189 lc1f2254 . . . . . . . . . . . . . . . . . 188, 189 lc1f265 . . . . . . . . . . . . . . . . . . 188, 189 lc1f2654 . . . . . . . . . . . . . . . . . 188, 189 lc1f330 . . . . . . . . . . . . . . . . . . 188, 189 lc1f3304 . . . . . . . . . . . . . . . . . 188, 189 lc1f400 . . . . . . . . . . . . . . . . . . 188, 189 lc1f4002 . . . . . . . . . . . . . . . . . 188, 189 lc1f4004 . . . . . . . . . . . . . . . . . 188, 189 lc1f500 . . . . . . . . . . . . . . . . . . 188, 189 lc1f5002 . . . . . . . . . . . . . . . . . 188, 189 lc1f5004 . . . . . . . . . . . . . . . . . 188, 189 lc1f630 . . . . . . . . . . . . . . . . . . 188, 189 lc1f6302 . . . . . . . . . . . . . . . . . 188, 189 lc1f6304 . . . . . . . . . . . . . . . . . 188, 189 lc1f780 . . . . . . . . . . . . . . . . . . 188, 189 lc1f7804 . . . . . . . . . . . . . . . . . 188, 189 lc1f800 . . . . . . . . . . . . . . . . . . 188, 189 lc1k0601 . . . . . . . . . . . . . . . . . . . . . . 43 lc1k06013 . . . . . . . . . . . . . . . . . . . . . 43 lc1k06015 . . . . . . . . . . . . . . . . . . . . . 43 lc1k06017 . . . . . . . . . . . . . . . . . . . . . 43 lc1k0610 . . . . . . . . . . . . . . . . . . . . . . 43 lc1k06103 . . . . . . . . . . . . . . . . . . . . . 43 lc1k06105 . . . . . . . . . . . . . . . . . . . . . 43 lc1k06107 . . . . . . . . . . . . . . . . . . . . . 43 lc1k09004 . . . . . . . . . . . . . . . . . . . . . 46 lc1k090043 . . . . . . . . . . . . . . . . . 46, 47 lc1k090045 . . . . . . . . . . . . . . . . . . . . 46 lc1k090047 . . . . . . . . . . . . . . . . . . . . 46 lc1k09008 . . . . . . . . . . . . . . . . . . . . . 46 lc1k090083 . . . . . . . . . . . . . . . . . 46, 47 lc1k090085 . . . . . . . . . . . . . . . . . . . . 46 lc1k090087 . . . . . . . . . . . . . . . . . . . . 46 lc1k0901 . . . . . . . . . . . . . . . . . . . 43, 46 lc1k09013 . . . . . . . . . . . . . . . 43, 46, 47 lc1k09015 . . . . . . . . . . . . . . . . . . 43, 46 lc1k09017 . . . . . . . . . . . . . . . . . . 43, 46 lc1k0910 . . . . . . . . . . . . . . . . . . . 43, 46 lc1k09103 . . . . . . . . . . . . . . . 43, 46, 47 lc1k09105 . . . . . . . . . . . . . . . . . . 43, 46 lc1k09107 . . . . . . . . . . . . . . . . . . 43, 46 lc1k1201 . . . . . . . . . . . . . . . . . . . . . . 43 lc1k12013 . . . . . . . . . . . . . . . . . . . . . 43 lc1k12015 . . . . . . . . . . . . . . . . . . . . . 43 lc1k12017 . . . . . . . . . . . . . . . . . . . . . 43 lc1k1210 . . . . . . . . . . . . . . . . . . . . . . 43 lc1k12103 . . . . . . . . . . . . . . . . . . . . . 43 lc1k12105 . . . . . . . . . . . . . . . . . . . . . 43 lc1k12107 . . . . . . . . . . . . . . . . . . . . . 43 lc1k1601 . . . . . . . . . . . . . . . . . . . . . . 43 lc1k16013 . . . . . . . . . . . . . . . . . . . . . 43 lc1k16015 . . . . . . . . . . . . . . . . . . . . . 43 lc1k16017 . . . . . . . . . . . . . . . . . . . . . 43 lc1k1610 . . . . . . . . . . . . . . . . . . . . . . 43 lc1k16103 . . . . . . . . . . . . . . . . . . . . . 43 lc1k16105 . . . . . . . . . . . . . . . . . . . . . 43 lc1k16107 . . . . . . . . . . . . . . . . . . . . . 43 lc2d09 . . . . . . . . . . . . . . . . . . . . 93, 176 lc2d0906 . . . . . . . . . . . . . . . . . . . . . 176 lc2d093 . . . . . . . . . . . . . . . . . . . . . . . 94 lc2d096 . . . . . . . . . . . . . . . . . . . 95, 176 lc2d099 . . . . . . . . . . . . . . . . . . . . . . 176 lc2d115 . . . . . . . . . . . . . . . . . . . . . . 176 lc2d11500 . . . . . . . . . . . . . . . . . . . . . 93 lc2d115004 . . . . . . . . . . . . . . . . . . . . 96 lc2d115004622 . . . . . . . . . . . . . . . . . . 97 lc2d1156 . . . . . . . . . . . . . . . . . . 95, 176 lc2d12 . . . . . . . . . . . . . . . . . . . . 93, 176 lc2d123 . . . . . . . . . . . . . . . . . . . . . . . 94 lc2d126 . . . . . . . . . . . . . . . . . . . 95, 176 lc2d129 . . . . . . . . . . . . . . . . . . . . . . 176 lc2d150 . . . . . . . . . . . . . . . . . . . . . . 176 lc2d15000 . . . . . . . . . . . . . . . . . . . . . 93 lc2d1506 . . . . . . . . . . . . . . . . . . 95, 176 lc2d18 . . . . . . . . . . . . . . . . . . . . 93, 176 lc2d183 . . . . . . . . . . . . . . . . . . . . . . . 94 lc2d186 . . . . . . . . . . . . . . . . . . . 95, 176 lc2d25 . . . . . . . . . . . . . . . . . . . . 93, 176 lc2d253 . . . . . . . . . . . . . . . . . . . . . . . 94 lc2d256 . . . . . . . . . . . . . . . . . . . 95, 176 lc2d32 . . . . . . . . . . . . . . . . . . . . 93, 176 lc2d323 . . . . . . . . . . . . . . . . . . . . . . . 94 lc2d326 . . . . . . . . . . . . . . . . . . . 95, 176 lc2d38 . . . . . . . . . . . . . . . . . . . . 93, 176 lc2d383 . . . . . . . . . . . . . . . . . . . . . . . 94 lc2d386 . . . . . . . . . . . . . . . . . . . 95, 176 lc2d40 . . . . . . . . . . . . . . . . . . . . 93, 176 lc2d50 . . . . . . . . . . . . . . . . . . . . 93, 176 lc2d65 . . . . . . . . . . . . . . . . . . . . 93, 176 lc2d65004 . . . . . . . . . . . . . . . . . . . . . 96 lc2d650046 . . . . . . . . . . . . . . . . . . . . 97 lc2d80 . . . . . . . . . . . . . . . . . . . . 93, 176 lc2d80004 . . . . . . . . . . . . . . . . . . . . . 96 lc2d800046 . . . . . . . . . . . . . . . . . . . . 97 lc2d95 . . . . . . . . . . . . . . . . . . . . 93, 176 lc2dt20 . . . . . . . . . . . . . . . . . . . . 96, 97 lc2dt25 . . . . . . . . . . . . . . . . 96, 97, 176 lc2dt256 . . . . . . . . . . . . . . . . . . . . . 176 lc2dt32 . . . . . . . . . . . . . . . . . . . . 96, 97 lc2dt40 . . . . . . . . . . . . . . . . 96, 97, 176 lc2dt406 . . . . . . . . . . . . . . . . . . . . . 176 lc2dt60 . . . . . . . . . . . . . . . . . . . . 96, 97
catalog number index 249 01/04 ? 2001-2004 schneider electric all rights reserved lc2k0601 . . . . . . . . . . . . . . . . . . . . . . 48 lc2k06013 . . . . . . . . . . . . . . . . . . . . . 48 lc2k06015 . . . . . . . . . . . . . . . . . . . . . 48 lc2k06017 . . . . . . . . . . . . . . . . . . . . . 48 lc2k0610 . . . . . . . . . . . . . . . . . . . . . . 48 lc2k06103 . . . . . . . . . . . . . . . . . . . . . 48 lc2k06105 . . . . . . . . . . . . . . . . . . . . . 48 lc2k06107 . . . . . . . . . . . . . . . . . . . . . 48 lc2k09004 . . . . . . . . . . . . . . . . . . . . . 51 lc2k090043 . . . . . . . . . . . . . . . . . . . . 51 lc2k090045 . . . . . . . . . . . . . . . . . . . . 51 lc2k090047 . . . . . . . . . . . . . . . . . . . . 51 lc2k0901 . . . . . . . . . . . . . . . . . . . 48, 51 lc2k09013 . . . . . . . . . . . . . . . . . . 48, 51 lc2k09015 . . . . . . . . . . . . . . . . . . 48, 51 lc2k09017 . . . . . . . . . . . . . . . . . . 48, 51 lc2k0910 . . . . . . . . . . . . . . . . . . . 48, 51 lc2k09103 . . . . . . . . . . . . . . . . . . 48, 51 lc2k09105 . . . . . . . . . . . . . . . . . . 48, 51 lc2k09107 . . . . . . . . . . . . . . . . . . 48, 51 lc2k1201 . . . . . . . . . . . . . . . . . . . . . . 48 lc2k12013 . . . . . . . . . . . . . . . . . . . . . 48 lc2k12015 . . . . . . . . . . . . . . . . . . . . . 48 lc2k12017 . . . . . . . . . . . . . . . . . . . . . 48 lc2k1210 . . . . . . . . . . . . . . . . . . . . . . 48 lc2k12103 . . . . . . . . . . . . . . . . . . . . . 48 lc2k12105 . . . . . . . . . . . . . . . . . . . . . 48 lc2k12107 . . . . . . . . . . . . . . . . . . . . . 48 lc2k1601 . . . . . . . . . . . . . . . . . . . . . . 48 lc2k16013 . . . . . . . . . . . . . . . . . . . . . 48 lc2k16015 . . . . . . . . . . . . . . . . . . . . . 48 lc2k16017 . . . . . . . . . . . . . . . . . . . . . 48 lc2k1610 . . . . . . . . . . . . . . . . . . . . . . 48 lc2k16103 . . . . . . . . . . . . . . . . . . . . . 48 lc2k16105 . . . . . . . . . . . . . . . . . . . . . 48 lc2k16107 . . . . . . . . . . . . . . . . . . . . . 48 lc3d090a . . . . . . . . . . . . . . . . . . . . . 146 lc3d09a . . . . . . . . . . . . . . . . . . . . . . 146 lc3d115 . . . . . . . . . . . . . . . . . . . . . . 146 lc3d120a . . . . . . . . . . . . . . . . . . . . . 146 lc3d12a . . . . . . . . . . . . . . . . . . . . . . 146 lc3d150 . . . . . . . . . . . . . . . . . . . . . . 146 lc3d180a . . . . . . . . . . . . . . . . . . . . . 146 lc3d18a . . . . . . . . . . . . . . . . . . . . . . 146 lc3d320a . . . . . . . . . . . . . . . . . . . . . 146 lc3d32a . . . . . . . . . . . . . . . . . . . . . . 146 lc3d40 . . . . . . . . . . . . . . . . . . . . . . . 146 lc3d50 . . . . . . . . . . . . . . . . . . . . . . . 146 lc3d80 . . . . . . . . . . . . . . . . . . . . . . . 146 lc3k06 . . . . . . . . . . . . . . . . . . . . . . . 146 lc3k09 . . . . . . . . . . . . . . . . . . . . . . . 146 lc4d09a . . . . . . . . . . . . . . . . . . . . . . 144 lc4d12a . . . . . . . . . . . . . . . . . . . . . . 144 lc4d18a . . . . . . . . . . . . . . . . . . . . . . 144 lc4d25a . . . . . . . . . . . . . . . . . . . . . . 144 lc4d32a . . . . . . . . . . . . . . . . . . . . . . 144 lc4d40 . . . . . . . . . . . . . . . . . . . . . . . 144 lc4d50 . . . . . . . . . . . . . . . . . . . . . . . 144 lc4d65 . . . . . . . . . . . . . . . . . . . . . . . 144 lc4d80 . . . . . . . . . . . . . . . . . . . . . . . 144 lc7k0601 . . . . . . . . . . . . . . . . . . . . . . 44 lc7k06015 . . . . . . . . . . . . . . . . . . . . . 44 lc7k06017 . . . . . . . . . . . . . . . . . . . . . 44 lc7k0610 . . . . . . . . . . . . . . . . . . . . . . 44 lc7k06105 . . . . . . . . . . . . . . . . . . . . . 44 lc7k06107 . . . . . . . . . . . . . . . . . . . . . 44 lc7k09004 . . . . . . . . . . . . . . . . . . . . . 46 lc7k090045 . . . . . . . . . . . . . . . . . . . . 46 lc7k090047 . . . . . . . . . . . . . . . . . . . . 46 lc7k09008 . . . . . . . . . . . . . . . . . . . . . 46 lc7k090085 . . . . . . . . . . . . . . . . . . . . 46 lc7k090087 . . . . . . . . . . . . . . . . . . . . 46 lc7k0901 . . . . . . . . . . . . . . . . . . . 44, 46 lc7k09015 . . . . . . . . . . . . . . . . . . 44, 46 lc7k09017 . . . . . . . . . . . . . . . . . . 44, 46 lc7k0910 . . . . . . . . . . . . . . . . . . . 44, 46 lc7k09105 . . . . . . . . . . . . . . . . . . 44, 46 lc7k09107 . . . . . . . . . . . . . . . . . . 44, 46 lc7k1201 . . . . . . . . . . . . . . . . . . . . . . 44 lc7k12015 . . . . . . . . . . . . . . . . . . . . . 44 lc7k12017 . . . . . . . . . . . . . . . . . . . . . 44 lc7k1210 . . . . . . . . . . . . . . . . . . . . . . 44 lc7k12105 . . . . . . . . . . . . . . . . . . . . . 44 lc7k12107 . . . . . . . . . . . . . . . . . . . . . 44 lc8k0601 . . . . . . . . . . . . . . . . . . . . . . 49 lc8k06015 . . . . . . . . . . . . . . . . . . . . . 49 lc8k06017 . . . . . . . . . . . . . . . . . . . . . 49 lc8k0610 . . . . . . . . . . . . . . . . . . . . . . 49 lc8k06105 . . . . . . . . . . . . . . . . . . . . . 49 lc8k06107 . . . . . . . . . . . . . . . . . . . . . 49 lc8k09004 . . . . . . . . . . . . . . . . . . . . . 51 lc8k090045 . . . . . . . . . . . . . . . . . . . . 51 lc8k090047 . . . . . . . . . . . . . . . . . . . . 51 lc8k0901 . . . . . . . . . . . . . . . . . . . 49, 51 lc8k09015 . . . . . . . . . . . . . . . . . . 49, 51 lc8k09017 . . . . . . . . . . . . . . . . . . 49, 51 lc8k0910 . . . . . . . . . . . . . . . . . . . 49, 51 lc8k09105 . . . . . . . . . . . . . . . . . . 49, 51 lc8k09107 . . . . . . . . . . . . . . . . . . 49, 51 lc8k1201 . . . . . . . . . . . . . . . . . . . . . . 49 lc8k12015 . . . . . . . . . . . . . . . . . . . . . 49 lc8k12017 . . . . . . . . . . . . . . . . . . . . . 49 lc8k1210 . . . . . . . . . . . . . . . . . . . . . . 49 lc8k12105 . . . . . . . . . . . . . . . . . . . . . 49 lc8k12107 . . . . . . . . . . . . . . . . . . . . . 49 le1d09. . . . . . . . . . . . . . . . . . . . . . . . 159 le1d093a6 . . . . . . . . . . . . . . . . . . . . 151 le1d093a7 . . . . . . . . . . . . . . . . . . . . 151 le1d096b6 . . . . . . . . . . . . . . . . . . . . 153 le1d096b7 . . . . . . . . . . . . . . . . . . . . 153 le1d097d6 . . . . . . . . . . . . . . . . . . . . 153 le1d097d7 . . . . . . . . . . . . . . . . . . . . 153 le1d12. . . . . . . . . . . . . . . . . . . . . . . . 159 le1d123a6 . . . . . . . . . . . . . . . . . . . . 151 le1d126b6 . . . . . . . . . . . . . . . . . . . . 153 le1d126b7 . . . . . . . . . . . . . . . . . . . . 153 le1d127d6 . . . . . . . . . . . . . . . . . . . . 153 le1d127d7 . . . . . . . . . . . . . . . . . . . . 153 le1d18. . . . . . . . . . . . . . . . . . . . . . . . 159 le1d183a6 . . . . . . . . . . . . . . . . . . . . 151 le1d183a7 . . . . . . . . . . . . . . . . . . . . 151 le1d186b7 . . . . . . . . . . . . . . . . . . . . 153 le1d187e6 . . . . . . . . . . . . . . . . . . . . 153 le1d187e7 . . . . . . . . . . . . . . . . . . . . 153 le1d25. . . . . . . . . . . . . . . . . . . . . . . . 159 le1d253a6 . . . . . . . . . . . . . . . . . . . . 151 le1d253a7 . . . . . . . . . . . . . . . . . . . . 151 le1d256b6 . . . . . . . . . . . . . . . . . . . . 153 le1d256b7 . . . . . . . . . . . . . . . . . . . . 153 le1d257e7 . . . . . . . . . . . . . . . . . . . . 153 le1d323a6 . . . . . . . . . . . . . . . . . . . . 151 le1d323a7 . . . . . . . . . . . . . . . . . . . . 151 le1d326c6 . . . . . . . . . . . . . . . . . . . . 153 le1d326c7 . . . . . . . . . . . . . . . . . . . . 153 le1d327f6. . . . . . . . . . . . . . . . . . . . . 153 le1d327f7. . . . . . . . . . . . . . . . . . . . . 153 le1d35. . . . . . . . . . . . . . . . . . . . . . . . 159 le1d403a6 . . . . . . . . . . . . . . . . . . . . 151 le1d403a7 . . . . . . . . . . . . . . . . . . . . 151 le1d405 . . . . . . . . . . . . . . . . . . . . . . 159 le1d406c6 . . . . . . . . . . . . . . . . . . . . 153 le1d406c7 . . . . . . . . . . . . . . . . . . . . 153 le1d407f6. . . . . . . . . . . . . . . . . . . . . 153 le1d407f7. . . . . . . . . . . . . . . . . . . . . 153 le1d503a6 . . . . . . . . . . . . . . . . . . . . 151 le1d503a7 . . . . . . . . . . . . . . . . . . . . 151 le1d505 . . . . . . . . . . . . . . . . . . . . . . 159 le1d653a6 . . . . . . . . . . . . . . . . . . . . 151 le1d653a7 . . . . . . . . . . . . . . . . . . . . 151 le1d655 . . . . . . . . . . . . . . . . . . . . . . 159 le1d803a6 . . . . . . . . . . . . . . . . . . . . 151 le1d803a7 . . . . . . . . . . . . . . . . . . . . 151 le1d805 . . . . . . . . . . . . . . . . . . . . . . 159 le1d955 . . . . . . . . . . . . . . . . . . . . . . 159 le2d09. . . . . . . . . . . . . . . . . . . . . . . . 159 le2d093a6 . . . . . . . . . . . . . . . . . . . . 151 le2d093a7 . . . . . . . . . . . . . . . . . . . . 151 le2d096 . . . . . . . . . . . . . . . . . . . . . . 162 le2d096b6 . . . . . . . . . . . . . . . . . . . . 153 le2d096b7 . . . . . . . . . . . . . . . . . . . . 153 le2d097d6 . . . . . . . . . . . . . . . . . . . . 153 le2d097d7 . . . . . . . . . . . . . . . . . . . . 153 le2d12. . . . . . . . . . . . . . . . . . . . . . . . 159 le2d123a6 . . . . . . . . . . . . . . . . . . . . 151 le2d123a7 . . . . . . . . . . . . . . . . . . . . 151 le2d126 . . . . . . . . . . . . . . . . . . . . . . 162 le2d126b6 . . . . . . . . . . . . . . . . . . . . 153 le2d126b7 . . . . . . . . . . . . . . . . . . . . 153 le2d127d6 . . . . . . . . . . . . . . . . . . . . 153 le2d127d7 . . . . . . . . . . . . . . . . . . . . 153 le2d18. . . . . . . . . . . . . . . . . . . . . . . . 159 le2d183a6 . . . . . . . . . . . . . . . . . . . . 151 le2d183a7 . . . . . . . . . . . . . . . . . . . . 151 le3d18. . . . . . . . . . . . . . . . . . . . . . . . 163 le2d186 . . . . . . . . . . . . . . . . . . . . . . 162 le2d186b6 . . . . . . . . . . . . . . . . . . . . 153 le2d186b7 . . . . . . . . . . . . . . . . . . . . 153 le2d187e6 . . . . . . . . . . . . . . . . . . . . 153 le2d187e7 . . . . . . . . . . . . . . . . . . . . 153 le2d25. . . . . . . . . . . . . . . . . . . . . . . . 159 le2d253a6 . . . . . . . . . . . . . . . . . . . . 151 le2d253a7 . . . . . . . . . . . . . . . . . . . . 151 le2d256 . . . . . . . . . . . . . . . . . . . . . . 162 le2d256b6 . . . . . . . . . . . . . . . . . . . . . 153 le2d256b7 . . . . . . . . . . . . . . . . . . . . . 153 le2d257e6 . . . . . . . . . . . . . . . . . . . . . 153 le2d257e7 . . . . . . . . . . . . . . . . . . . . . 153 le2d323a6 . . . . . . . . . . . . . . . . . . . . . 151 le2d323a7 . . . . . . . . . . . . . . . . . . . . . 151 le2d326 . . . . . . . . . . . . . . . . . . . . . . 162 le2d326c6. . . . . . . . . . . . . . . . . . . . . 153 le2d326c7. . . . . . . . . . . . . . . . . . . . . 153 le2d327f6 . . . . . . . . . . . . . . . . . . . . . 153 le2d327f7 . . . . . . . . . . . . . . . . . . . . . 153 le2d35 . . . . . . . . . . . . . . . . . . . . . . . . 159 le2d403a6 . . . . . . . . . . . . . . . . . . . . . 151 le2d403a7 . . . . . . . . . . . . . . . . . . . . . 151 le2d406 . . . . . . . . . . . . . . . . . . 159, 162 le2d406c6. . . . . . . . . . . . . . . . . . . . . 153 le2d406c7. . . . . . . . . . . . . . . . . . . . . 153 le2d407f6 . . . . . . . . . . . . . . . . . . . . . 153 le2d407f7 . . . . . . . . . . . . . . . . . . . . . 153 le2d503a6 . . . . . . . . . . . . . . . . . . . . . 151 le2d503a7 . . . . . . . . . . . . . . . . . . . . . 151 le2d506 . . . . . . . . . . . . . . . . . . 159, 162 le2d653a6 . . . . . . . . . . . . . . . . . . . . . 151 le2d653a7 . . . . . . . . . . . . . . . . . . . . . 151 le2d656 . . . . . . . . . . . . . . . . . . . . . . . 159 le2d803a6 . . . . . . . . . . . . . . . . . . . . . 151 le2d803a7 . . . . . . . . . . . . . . . . . . . . . 151 le2d805 . . . . . . . . . . . . . . . . . . . . . . . 159 le2d806 . . . . . . . . . . . . . . . . . . . . . . . 159 le2d655 . . . . . . . . . . . . . . . . . . . . . . 161 le2d656 . . . . . . . . . . . . . . . . . . . . . . 162 le2d805 . . . . . . . . . . . . . . . . . . . . . . 163 le2d806 . . . . . . . . . . . . . . . . . . . . . . 162 le2d955 . . . . . . . . . . . . . . . . . . . . . . 159 le2k065 . . . . . . . . . . . . . . . . . . . . . . 159 le2k095 . . . . . . . . . . . . . . . . . . . . . . 159 le3d09 . . . . . . . . . . . . . . . . . . . . . . . 163 le3d12 . . . . . . . . . . . . . . . . . . . . . . . 163 le3d32 . . . . . . . . . . . . . . . . . . . . . . . . 163 le3d405 . . . . . . . . . . . . . . . . . . . . . . . 163 le3d406 . . . . . . . . . . . . . . . . . . . . . . 164 le3d505 . . . . . . . . . . . . . . . . . . . . . . . 163 le3d506 . . . . . . . . . . . . . . . . . . . . . . 164 le3d805 . . . . . . . . . . . . . . . . . . . . . . . 163 le3d806 . . . . . . . . . . . . . . . . . . . . . . 164 le3k065 . . . . . . . . . . . . . . . . . . . . . . 163 le3k095 . . . . . . . . . . . . . . . . . . . . . . 163 le4k065 . . . . . . . . . . . . . . . . . . . . . . . 159 le4k095 . . . . . . . . . . . . . . . . . . . . . . . 159 le4d09 . . . . . . . . . . . . . . . . . . . . . . . . 159 le4d09 . . . . . . . . . . . . . . . . . . . . . . . . 159 le4d12 . . . . . . . . . . . . . . . . . . . . . . . . 159 le4d18 . . . . . . . . . . . . . . . . . . . . . . . . 159 le4d25 . . . . . . . . . . . . . . . . . . . . . . . . 159 le4d35 . . . . . . . . . . . . . . . . . . . . . . . . 159 le4d406 . . . . . . . . . . . . . . . . . . . . . . . 159 le4d506 . . . . . . . . . . . . . . . . . . . . . . . 159 le4d656 . . . . . . . . . . . . . . . . . . . . . . . 159 le4d806 . . . . . . . . . . . . . . . . . . . . . . . 159 le6d09 . . . . . . . . . . . . . . . . . . . . . . . . 164 le6d12 . . . . . . . . . . . . . . . . . . . . . . . . 164 le6d18 . . . . . . . . . . . . . . . . . . . . . . . . 164 le6d326 . . . . . . . . . . . . . . . . . . . . . . . 164 le8k065 . . . . . . . . . . . . . . . . . . 159, 162 le8k095 . . . . . . . . . . . . . . . . . . 159, 162 le8d09 . . . . . . . . . . . . . . . . . . . . . . . . 159 le8d12 . . . . . . . . . . . . . . . . . . . . . . . . 159 le8d18 . . . . . . . . . . . . . . . . . . . . . . . . 159 le8d25 . . . . . . . . . . . . . . . . . . . . . . . . 159 le8d35 . . . . . . . . . . . . . . . . . . . . . . . . 159 lp1d40004 . . . . . . . . . . . . . . . . . . 91, 92 lp1d40008 . . . . . . . . . . . . . . . . . . 91, 92 lp1d65004 . . . . . . . . . . . . . . . . . . . . . 91 lp1d800046 . . . . . . . . . . . . . . . . . . . . 92 lp1d65008 . . . . . . . . . . . . . . . . . . . . . 91 lp1d650086 . . . . . . . . . . . . . . . . . . . . 92 lp1d80004 . . . . . . . . . . . . . . . . . . . . . 91 lp1d800046 . . . . . . . . . . . . . . . . . . . . 92 lp1d80008 . . . . . . . . . . . . . . . . . . . . . 91 lp1d800086 . . . . . . . . . . . . . . . . . . . . 92 lp1k0601 . . . . . . . . . . . . . . . . . . . . . . 45 lp1k06013 . . . . . . . . . . . . . . . . . . . . . 45 lp1k06015 . . . . . . . . . . . . . . . . . . . . . 45 lp1k06017 . . . . . . . . . . . . . . . . . . . . . 45 lp1k0610 . . . . . . . . . . . . . . . . . . . . . . 45 lp1k06103 . . . . . . . . . . . . . . . . . . . . . 45 lp1k06105 . . . . . . . . . . . . . . . . . . . . . 45 lp1k06107 . . . . . . . . . . . . . . . . . . . . . 45 lp1k09004 . . . . . . . . . . . . . . . . . . . . . 47 lp1k090045 . . . . . . . . . . . . . . . . . . . . 47 lp1k090047 . . . . . . . . . . . . . . . . . . . . .47 lp1k09008 . . . . . . . . . . . . . . . . . . . . . .47 lp1k090085 . . . . . . . . . . . . . . . . . . . . .47 lp1k090087 . . . . . . . . . . . . . . . . . . . . .47 lp1k0901 . . . . . . . . . . . . . . . . . . . .45, 47 lp1k09013 . . . . . . . . . . . . . . . . . . . . . .45 lp1k09015 . . . . . . . . . . . . . . . . . . .45, 47 lp1k09017 . . . . . . . . . . . . . . . . . . .45, 47 lp1k0910 . . . . . . . . . . . . . . . . . . . .45, 47 lp1k09103 . . . . . . . . . . . . . . . . . . . . . .45 lp1k09105 . . . . . . . . . . . . . . . . . . .45, 47 lp1k09107 . . . . . . . . . . . . . . . . . . .45, 47 lp1k1201 . . . . . . . . . . . . . . . . . . . . . . .45 lp1k12013 . . . . . . . . . . . . . . . . . . . . . .45 lp1k12015 . . . . . . . . . . . . . . . . . . . . . .45 lp1k12017 . . . . . . . . . . . . . . . . . . . . . .45 lp1k1210 . . . . . . . . . . . . . . . . . . . . . . .45 lp1k12103 . . . . . . . . . . . . . . . . . . . . . .45 lp1k12105 . . . . . . . . . . . . . . . . . . . . . .45 lp1k12107 . . . . . . . . . . . . . . . . . . . . . .45 lp2d40004 . . . . . . . . . . . . . . . . . . . . . .96 lp2400046 . . . . . . . . . . . . . . . . . . . . . .97 lp2d80004 . . . . . . . . . . . . . . . . . . . . . .96 lp2d800046 . . . . . . . . . . . . . . . . . . . . .97 lp2k0601 . . . . . . . . . . . . . . . . . . . . . . .50 lp2k06015 . . . . . . . . . . . . . . . . . . . . . .50 lp2k06017 . . . . . . . . . . . . . . . . . . . . . .50 lp2k06103 . . . . . . . . . . . . . . . . . . . . . .50 lp2k06105 . . . . . . . . . . . . . . . . . . . . . .50 lp2k06107 . . . . . . . . . . . . . . . . . . . . . .50 lp2k09004 . . . . . . . . . . . . . . . . . . . . . .52 lp2k090045 . . . . . . . . . . . . . . . . . . . . .52 lp2k090047 . . . . . . . . . . . . . . . . . . . . .52 lp2k09013 . . . . . . . . . . . . . . . . . . .50, 52 lp2k09015 . . . . . . . . . . . . . . . . . . .50, 52 lp2k09017 . . . . . . . . . . . . . . . . . . .50, 52 lp2k09103 . . . . . . . . . . . . . . . . . . .50, 52 lp2k09105 . . . . . . . . . . . . . . . . . . .50, 52 lp2k09107 . . . . . . . . . . . . . . . . . . .50, 52 lp2k12013 . . . . . . . . . . . . . . . . . . . . . .50 lp2k12015 . . . . . . . . . . . . . . . . . . . . . .50 lp2k12017 . . . . . . . . . . . . . . . . . . . . . .50 lp2k1210 3 . . . . . . . . . . . . . . . . . . . . . .50 lp2k12105 . . . . . . . . . . . . . . . . . . . . . .50 lp2k12107 . . . . . . . . . . . . . . . . . . . . . .50 lp4k0601 . . . . . . . . . . . . . . . . . . . . . . .68 lp4k06013 . . . . . . . . . . . . . . . . . . . . . .68 lp4k06015 . . . . . . . . . . . . . . . . . . . . . .68 lp4k06017 . . . . . . . . . . . . . . . . . . . . . .68 lp4k0610 . . . . . . . . . . . . . . . . . . . . . . .68 lp4k06103 . . . . . . . . . . . . . . . . . . . . . .68 lp4k06105 . . . . . . . . . . . . . . . . . . . . . .68 lp4k06107 . . . . . . . . . . . . . . . . . . . . . .68 lp4k09004 . . . . . . . . . . . . . . . . . . . . . .70 lp4k090043 . . . . . . . . . . . . . . . . . . . . .70 lp4k090045 . . . . . . . . . . . . . . . . . . . . .70 lp4k090047 . . . . . . . . . . . . . . . . . . . . .70 lp4k09008 . . . . . . . . . . . . . . . . . . . . . .70 lp4k090083 . . . . . . . . . . . . . . . . . . . . .70 lp4k090085 . . . . . . . . . . . . . . . . . . . . .70 lp4k090087 . . . . . . . . . . . . . . . . . . . . .70 lp4k0901 . . . . . . . . . . . . . . . . . . . .68, 70 lp4k09013 . . . . . . . . . . . . . . . . . . .68, 70 lp4k09015 . . . . . . . . . . . . . . . . . . .68, 70 lp4k09017 . . . . . . . . . . . . . . . . . . .68, 70 lp4k0910 . . . . . . . . . . . . . . . . . . . .68, 70 lp4k09103 . . . . . . . . . . . . . . . . . . .68, 70 lp4k09105 . . . . . . . . . . . . . . . . . . .68, 70 lp4k09107 . . . . . . . . . . . . . . . . . . .68, 70 lp4k1201 . . . . . . . . . . . . . . . . . . . . . . .68 lp4k12013 . . . . . . . . . . . . . . . . . . . . . .68 lp4k12015 . . . . . . . . . . . . . . . . . . . . . .68 lp4k12017 . . . . . . . . . . . . . . . . . . . . . .68 lp4k1210 . . . . . . . . . . . . . . . . . . . . . . .68 lp4k12103 . . . . . . . . . . . . . . . . . . . . . .68 lp4k12105 . . . . . . . . . . . . . . . . . . . . . .68 lp4k12107 . . . . . . . . . . . . . . . . . . . . . .68 lp5k0601 . . . . . . . . . . . . . . . . . . . . . . .69 lp5k06013 . . . . . . . . . . . . . . . . . . . . . .69 lp5k06015 . . . . . . . . . . . . . . . . . . . . . .69 lp5k06017 . . . . . . . . . . . . . . . . . . . . . .69 lp5k0610 . . . . . . . . . . . . . . . . . . . . . . .69 lp5k06103 . . . . . . . . . . . . . . . . . . . . . .69 lp5k06105 . . . . . . . . . . . . . . . . . . . . . .69 lp5k06107 . . . . . . . . . . . . . . . . . . . . . .69 lp5k09004 . . . . . . . . . . . . . . . . . . . . . .71 lp5k090043 . . . . . . . . . . . . . . . . . . . . .71 lp5k090045 . . . . . . . . . . . . . . . . . . . . .71 lp5k090047 . . . . . . . . . . . . . . . . . . . . .71 lp5k0901 . . . . . . . . . . . . . . . . . . . .69, 71 lp5k09013 . . . . . . . . . . . . . . . . . . .69, 71
catalog number index ? 2001-2004 schneider electric all rights reserved 250 01/04 lp5k09015 . . . . . . . . . . . . . . . . . . 69, 71 lp5k09017 . . . . . . . . . . . . . . . . . . 69, 71 lp5k0910 . . . . . . . . . . . . . . . . . . . 69, 71 lp5k09103 . . . . . . . . . . . . . . . . . . 69, 71 lp5k09105 . . . . . . . . . . . . . . . . . . 69, 71 lp5k09107 . . . . . . . . . . . . . . . . . . 69, 71 lp5k1201 . . . . . . . . . . . . . . . . . . . . . . 69 lp5k12013 . . . . . . . . . . . . . . . . . . . . . 69 lp5k12015 . . . . . . . . . . . . . . . . . . . . . 69 lp5k12017 . . . . . . . . . . . . . . . . . . . . . 69 lp5k1210 . . . . . . . . . . . . . . . . . . . . . . 69 lp5k12103 . . . . . . . . . . . . . . . . . . . . . 69 lp5k12105 . . . . . . . . . . . . . . . . . . . . . 69 lp5k12107 . . . . . . . . . . . . . . . . . . . . . 69 lr2k0301 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0302 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0303 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0304 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0305 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0306 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0307 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0308 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0310 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0312 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0314 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0316 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0321 . . . . . . . . . . . . . . . . . . . . . . 63 lr2k0322 . . . . . . . . . . . . . . . . . . . . . . 63 lr3d01 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d02 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d03 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d04 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d05 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d06 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d07 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d08 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d10 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d12 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d14 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d16 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d21 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d22 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d32 . . . . . . . . . . . . . . . . . . . . . . . 177 lr3d3322 . . . . . . . . . . . . . . . . . . . . . 177 lr3d3353 . . . . . . . . . . . . . . . . . . . . . 177 lr3d3355 . . . . . . . . . . . . . . . . . . . . . 177 lr3d3357 . . . . . . . . . . . . . . . . . . . . . 177 lr3d3359 . . . . . . . . . . . . . . . . . . . . . 177 lr3d3361 . . . . . . . . . . . . . . . . . . . . . 177 lr3d3363 . . . . . . . . . . . . . . . . . . . . . 177 lr3d3365 . . . . . . . . . . . . . . . . . . . . . 177 lr3d35 . . . . . . . . . . . . . . . . . . . . . . . 177 lr9f5357 . . . . . . . . . . . . . . . . . . . . . 220 lr9f5363 . . . . . . . . . . . . . . . . . . . . . 220 lr9f5367 . . . . . . . . . . . . . . . . . . . . . 220 lr9f5369 . . . . . . . . . . . . . . . . . . . . . 220 lr9f5371 . . . . . . . . . . . . . . . . . . . . . 220 lr9f5557 . . . . . . . . . . . . . . . . . . . . . 220 lr9f5563 . . . . . . . . . . . . . . . . . . . . . 220 lr9f5567 . . . . . . . . . . . . . . . . . . . . . 220 lr9f5569 . . . . . . . . . . . . . . . . . . . . . 220 lr9f5571 . . . . . . . . . . . . . . . . . . . . . 220 lr9f7375 . . . . . . . . . . . . . . . . . . . . . 220 lr9f7379 . . . . . . . . . . . . . . . . . . . . . 220 lr9f7381 . . . . . . . . . . . . . . . . . . . . . 220 lr9f7575 . . . . . . . . . . . . . . . . . . . . . 220 lr9f7579 . . . . . . . . . . . . . . . . . . . . . 220 lr9f7581 . . . . . . . . . . . . . . . . . . . . . 220 lrd01 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd013 . . . . . . . . . . . . . . . . . . . . . . . .134 lrd02 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd023 . . . . . . . . . . . . . . . . . . . . . . . 134 lrd03 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd033 . . . . . . . . . . . . . . . . . . . . . . . 134 lrd04 . . . . . . . . . . . . . . . . . . . . . . . . 134 lrd043 . . . . . . . . . . . . . . . . . . . . . . . 134 lrd05 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd053 . . . . . . . . . . . . . . . . . . . . . . . 134 lrd06 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd063 . . . . . . . . . . . . . . . . . . . . . . . 134 lrd07 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd073 . . . . . . . . . . . . . . . . . . . . . . . 134 lrd08 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd083 . . . . . . . . . . . . . . . . . . . . . . . 134 lrd10 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd103 . . . . . . . . . . . . . . . . . . . . . . . 134 lrd12 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd123 . . . . . . . . . . . . . . . . . . . . . . . 134 lrd14 . . . . . . . . . . . . . . . . . . . . . . . . 134 lrd143 . . . . . . . . . . . . . . . . . . . . . . . 134 lrd1508 . . . . . . . . . . . . . . . . . . . . . . 177 lrd1510 . . . . . . . . . . . . . . . . . . . . . . 177 lrd1512 . . . . . . . . . . . . . . . . . . . . . . 177 lrd1514 . . . . . . . . . . . . . . . . . . . . . . 177 lrd1516 . . . . . . . . . . . . . . . . . . . . . . 177 lrd1521 . . . . . . . . . . . . . . . . . . . . . . 177 lrd1522 . . . . . . . . . . . . . . . . . . . . . . 177 lrd1530 . . . . . . . . . . . . . . . . . . . . . . 177 lrd1531 . . . . . . . . . . . . . . . . . . . . . . 177 lrd16 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd163 . . . . . . . . . . . . . . . . . . . . . . . . 134 lrd21 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd213 . . . . . . . . . . . . . . . . . . . . . . . . 134 lrd22 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd223 . . . . . . . . . . . . . . . . . . . . . . . . 134 lrd32 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd3301a66 . . . . . . . . . . . . . . . . . . . 177 lrd3302a66 . . . . . . . . . . . . . . . . . . . 177 lrd3303a66 . . . . . . . . . . . . . . . . . . . 177 lrd3304a66 . . . . . . . . . . . . . . . . . . . 177 lrd3305a66 . . . . . . . . . . . . . . . . . . . 177 lrd3306a66 . . . . . . . . . . . . . . . . . . . 177 lrd3307a66 . . . . . . . . . . . . . . . . . . . 177 lrd3308a66 . . . . . . . . . . . . . . . . . . . 177 lrd3310a66 . . . . . . . . . . . . . . . . . . . 177 lrd3312a66 . . . . . . . . . . . . . . . . . . . 177 lrd3314a66 . . . . . . . . . . . . . . . . . . . 177 lrd3316a66 . . . . . . . . . . . . . . . . . . . 177 lrd3321a66 . . . . . . . . . . . . . . . . . . . 177 lrd3322 . . . . . . . . . . . . . . . . . . . . . . 177 lrd3322a66 . . . . . . . . . . . . . . . . . . . 177 lrd3353 . . . . . . . . . . . . . . . . . . . . . 177 lrd3355 . . . . . . . . . . . . . . . . . . . . . 177 lrd3357 . . . . . . . . . . . . . . . . . . . . . 177 lrd3359 . . . . . . . . . . . . . . . . . . . . . 177 lrd3361 . . . . . . . . . . . . . . . . . . . . . 177 lrd3363 . . . . . . . . . . . . . . . . . . . . . 177 lrd3365 . . . . . . . . . . . . . . . . . . . . . . 177 lrd33x6a66 . . . . . . . . . . . . . . . . . . . 177 lrd35 . . . . . . . . . . . . . . . . . . . . . . . . 177 lrd3522 . . . . . . . . . . . . . . . . . . . . . . . 135 lrd4365 . . . . . . . . . . . . . . . . . . . . . . 177 lrd4367 . . . . . . . . . . . . . . . . . . . . . . 177 lrd4369 . . . . . . . . . . . . . . . . . . . . . . 177 lr9d5367 . . . . . . . . . . . . . . . . . . . . . . 135 lr9d5369 . . . . . . . . . . . . . . . . . . . . . . 135 lr9d5567 . . . . . . . . . . . . . . . . . . . . . . 135 lr9d5569 . . . . . . . . . . . . . . . . . . . . . . 135 lr9d67 . . . . . . . . . . . . . . . . . . . . . . . . 135 lr9d69 . . . . . . . . . . . . . . . . . . . . . . . . 135 lx0ff005 . . . . . . . . . . . . . . . . . . . . . . 234 lx0ff006 . . . . . . . . . . . . . . . . . . . . . . 234 lx0ff007 . . . . . . . . . . . . . . . . . . . . . . 234 lx0ff008 . . . . . . . . . . . . . . . . . . . . . . 234 lx0ff009 . . . . . . . . . . . . . . . . . . . . . . 234 lx0ff010 . . . . . . . . . . . . . . . . . . . . . . 234 lx0ff011 . . . . . . . . . . . . . . . . . . . . . . 234 lx0ff020 . . . . . . . . . . . . . . . . . . . . . . 234 lx0ff055 . . . . . . . . . . . . . . . . . . . . . . 235 lx0ff056 . . . . . . . . . . . . . . . . . . . . . . 235 lx0ff057 . . . . . . . . . . . . . . . . . . . . . . 235 lx0ff058 . . . . . . . . . . . . . . . . . . . . . . 235 lx0ff224 . . . . . . . . . . . . . . . . . . . . . . 235 lx0fg005 . . . . . . . . . . . . . . . . . . . . . 234 lx0fg006 . . . . . . . . . . . . . . . . . . . . . 234 lx0fg007 . . . . . . . . . . . . . . . . . . . . . 234 lx0fg008 . . . . . . . . . . . . . . . . . . . . . 234 lx0fg009 . . . . . . . . . . . . . . . . . . . . . 234 lx0fg010 . . . . . . . . . . . . . . . . . . . . . 234 lx0fg011 . . . . . . . . . . . . . . . . . . . . . 234 lx0fg020 . . . . . . . . . . . . . . . . . . . . . 234 lx0fg055 . . . . . . . . . . . . . . . . . . . . . 235 lx0fg056 . . . . . . . . . . . . . . . . . . . . . 235 lx0fg057 . . . . . . . . . . . . . . . . . . . . . 235 lx0fg058 . . . . . . . . . . . . . . . . . . . . . 235 lx0fg224 . . . . . . . . . . . . . . . . . . . . . 235 lx0fh005 . . . . . . . . . . . . . . . . . . . . . 234 lx0fh006 . . . . . . . . . . . . . . . . . . . . . 234 lx0fh007 . . . . . . . . . . . . . . . . . . . . . 234 lx0fh008 . . . . . . . . . . . . . . . . . . . . . 234 lx0fh009 . . . . . . . . . . . . . . . . . . . . . 234 lx0fh010 . . . . . . . . . . . . . . . . . . . . . 234 lx0fh011 . . . . . . . . . . . . . . . . . . . . . 234 lx0fh020 . . . . . . . . . . . . . . . . . . . . . 234 lx0fh055 . . . . . . . . . . . . . . . . . . . . . 235 lx0fh056 . . . . . . . . . . . . . . . . . . . . . 235 lx0fh057 . . . . . . . . . . . . . . . . . . . . . 235 lx0fh058 . . . . . . . . . . . . . . . . . . . . . 235 lx0fh224 . . . . . . . . . . . . . . . . . . . . . 235 lx0fj005 . . . . . . . . . . . . . . . . . . . . . . 234 lx0fj006 . . . . . . . . . . . . . . . . . . . . . . 234 lx0fj007 . . . . . . . . . . . . . . . . . . . . . . 234 lx0fj008 . . . . . . . . . . . . . . . . . . . . . 234 lx0fj009 . . . . . . . . . . . . . . . . . . . . . 234 lx0fj010 . . . . . . . . . . . . . . . . . . . . . 234 lx0fj011 . . . . . . . . . . . . . . . . . . . . . 234 lx0fj020 . . . . . . . . . . . . . . . . . . . . . 234 lx0fj055 . . . . . . . . . . . . . . . . . . . . . 235 lx0fj056 . . . . . . . . . . . . . . . . . . . . . 235 lx0fj057 . . . . . . . . . . . . . . . . . . . . . 235 lx0fj058 . . . . . . . . . . . . . . . . . . . . . 235 lx0fj224 . . . . . . . . . . . . . . . . . . . . . 235 lx0fk005 . . . . . . . . . . . . . . . . . . . . . 234 lx0fk006 . . . . . . . . . . . . . . . . . . . . . 234 lx0fk007 . . . . . . . . . . . . . . . . . . . . . 234 lx0fk008 . . . . . . . . . . . . . . . . . . . . . 234 lx0fk009 . . . . . . . . . . . . . . . . . . . . . 234 lx0fk010 . . . . . . . . . . . . . . . . . . . . . 234 lx0fk011 . . . . . . . . . . . . . . . . . . . . . 234 lx0fk020 . . . . . . . . . . . . . . . . . . . . . 234 lx0fk055 . . . . . . . . . . . . . . . . . . . . . 235 lx0fk056 . . . . . . . . . . . . . . . . . . . . . 235 lx0fk057 . . . . . . . . . . . . . . . . . . . . . 235 lx0fk058 . . . . . . . . . . . . . . . . . . . . . 235 lx0fk224 . . . . . . . . . . . . . . . . . . . . . 235 lx0fl005 . . . . . . . . . . . . . . . . . . . . . 234 lx0fl006 . . . . . . . . . . . . . . . . . . . . . 234 lx0fl007 . . . . . . . . . . . . . . . . . . . . . 234 lx0fl008 . . . . . . . . . . . . . . . . . . . . . 234 lx0fl009 . . . . . . . . . . . . . . . . . . . . . 234 lx0fl010 . . . . . . . . . . . . . . . . . . . . . 234 lx0fl011 . . . . . . . . . . . . . . . . . . . . . 234 lx0fl020 . . . . . . . . . . . . . . . . . . . . . 234 lx0fl055 . . . . . . . . . . . . . . . . . . . . . 235 lx0fl056 . . . . . . . . . . . . . . . . . . . . . 235 lx0fl057 . . . . . . . . . . . . . . . . . . . . . 235 lx0fl058 . . . . . . . . . . . . . . . . . . . . . 235 lx0fl224 . . . . . . . . . . . . . . . . . . . . . 235 lx1d6b5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6b6 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6b7 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6c5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6d5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6d7 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6e5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6e6 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6e7 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6f5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6f6 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6f7 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6fe5 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6fe7 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6g5 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6g6 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6g7 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6l6 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6m5 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6m6 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6m7 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6n5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6n7 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6p5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6p7 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6q5 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6q6 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6q7 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6r5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6r6 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6r7 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6s5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6s6 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6t6 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6u5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6u6 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6u7 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6v5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6v7 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6w5 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6w6 . . . . . . . . . . . . . . . . . . . . . 118 lx1d6x6 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d6y5 . . . . . . . . . . . . . . . . . . . . . . 118 lx1d8b5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8b6 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8b7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8c5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8c7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8d5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8d7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8e5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8e6 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8e7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8f5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8f6 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8f7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8fc5 . . . . . . . . . . . . . . . . . . . . . 119 lx1d8fc7 . . . . . . . . . . . . . . . . . . . . . 119 lx1d8fe5 . . . . . . . . . . . . . . . . . . . . . 119 lx1d8fe7 . . . . . . . . . . . . . . . . . . . . . 119 lx1d8g6 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8g7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8l6 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8le7 . . . . . . . . . . . . . . . . . . . . . 119 lx1d8m5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8m6 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8m7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8n5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8n7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8p5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8p7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8q5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8q6 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8q7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8r5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8r6 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8r7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8s5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8s7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8t6 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8t7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8u5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8u6 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8u7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8ue7 . . . . . . . . . . . . . . . . . . . . . 119 lx1d8v5 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8v7 . . . . . . . . . . . . . . . . . . . . . . 119 lx1d8w6 . . . . . . . . . . . . . . . . . . . . . . 119 lx1ff024 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff040 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff042 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff048 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff092 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff095 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff1000 . . . . . . . . . . . . . . . . . . . . 202 lx1ff110 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff127 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff162 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff184 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff187 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff220 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff240 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff316 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff340 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff360 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff380 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff415 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff500 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff550 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff660 . . . . . . . . . . . . . . . . . . . . . 202 lx1ff850 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg024 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg040 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg042 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg048 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg092 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg095 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg1000 . . . . . . . . . . . . . . . . . . . . 202 lx1fg110 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg127 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg162 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg184 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg187 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg220 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg240 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg316 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg340 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg360 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg380 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg415 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg500 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg550 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg660 . . . . . . . . . . . . . . . . . . . . . 202 lx1fg850 . . . . . . . . . . . . . . . . . . . . . 202 lx1fh0482 . . . . . . . . . . . . . . . . . . . . 203 lx1fh10002 . . . . . . . . . . . . . . . . . . . 203 lx1fh1102 . . . . . . . . . . . . . . . . . . . . 203 lx1fh1272 . . . . . . . . . . . . . . . . . . . . 203 lx1fh2002 . . . . . . . . . . . . . . . . . . . . 203 lx1fh2202 . . . . . . . . . . . . . . . . . . . . 203 lx1fh2402 . . . . . . . . . . . . . . . . . . . . 203 lx1fh2772 . . . . . . . . . . . . . . . . . . . . 203 lx1fh3802 . . . . . . . . . . . . . . . . . . . . 203 lx1fh5002 . . . . . . . . . . . . . . . . . . . . 203 lx1fh6002 . . . . . . . . . . . . . . . . . . . . 203 lx1fj048 . . . . . . . . . . . . . . . . . . . . . . 203
catalog number index 251 01/04 ? 2001-2004 schneider electric all rights reserved lx1fj1000 . . . . . . . . . . . . . . . . . . . . 203 lx1fj110 . . . . . . . . . . . . . . . . . . . . . 203 lx1fj127 . . . . . . . . . . . . . . . . . . . . . 203 lx1fj200 . . . . . . . . . . . . . . . . . . . . . 203 lx1fj220 . . . . . . . . . . . . . . . . . . . . . 203 lx1fj240 . . . . . . . . . . . . . . . . . . . . . 203 lx1fj280 . . . . . . . . . . . . . . . . . . . . . 203 lx1fj380 . . . . . . . . . . . . . . . . . . . . . 203 lx1fj415 . . . . . . . . . . . . . . . . . . . . . 203 lx1fj500 . . . . . . . . . . . . . . . . . . . . . 203 lx1fj600 . . . . . . . . . . . . . . . . . . . . . 203 lx1fk048 . . . . . . . . . . . . . . . . . . . . . 203 lx1fk1000 . . . . . . . . . . . . . . . . . . . . 203 lx1fk110 . . . . . . . . . . . . . . . . . . . . . 203 lx1fk127 . . . . . . . . . . . . . . . . . . . . . 203 lx1fk200 . . . . . . . . . . . . . . . . . . . . . 203 lx1fk220 . . . . . . . . . . . . . . . . . . . . . 203 lx1fk240 . . . . . . . . . . . . . . . . . . . . . 203 lx1fk280 . . . . . . . . . . . . . . . . . . . . . 203 lx1fk380 . . . . . . . . . . . . . . . . . . . . . 203 lx1fk415 . . . . . . . . . . . . . . . . . . . . . 203 lx1fk500 . . . . . . . . . . . . . . . . . . . . . 203 lx1fk600 . . . . . . . . . . . . . . . . . . . . . 203 lx1fl048 . . . . . . . . . . . . . . . . . . . . . 204 lx1fl1000 . . . . . . . . . . . . . . . . . . . . 204 lx1fl110 . . . . . . . . . . . . . . . . . . . . . 204 lx1fl127 . . . . . . . . . . . . . . . . . . . . . 204 lx1fl200 . . . . . . . . . . . . . . . . . . . . . 204 lx1fl220 . . . . . . . . . . . . . . . . . . . . . 204 lx1fl260 . . . . . . . . . . . . . . . . . . . . . 204 lx1fl380 . . . . . . . . . . . . . . . . . . . . . 204 lx1fl415 . . . . . . . . . . . . . . . . . . . . . 204 lx1fl500 . . . . . . . . . . . . . . . . . . . . . 204 lx1fl600 . . . . . . . . . . . . . . . . . . . . . 204 lx1fx110 . . . . . . . . . . . . . . . . . . . . . 204 lx1fx127 . . . . . . . . . . . . . . . . . . . . . 204 lx1fx200 . . . . . . . . . . . . . . . . . . . . . 204 lx1fx220 . . . . . . . . . . . . . . . . . . . . . 204 lx1fx280 . . . . . . . . . . . . . . . . . . . . . 204 lx1fx380 . . . . . . . . . . . . . . . . . . . . . 204 lx1fx415 . . . . . . . . . . . . . . . . . . . . . 204 lx1fx500 . . . . . . . . . . . . . . . . . . . . . 204 lx4d6bd . . . . . . . . . . . . . . . . . . . . . 120 lx4d6bw . . . . . . . . . . . . . . . . . . . . . 121 lx4d6cd . . . . . . . . . . . . . . . . . . . . . 120 lx4d6cw . . . . . . . . . . . . . . . . . . . . . 121 lx4d6ed . . . . . . . . . . . . . . . . . . . . . 120 lx4d6ew . . . . . . . . . . . . . . . . . . . . . 121 lx4d6fd . . . . . . . . . . . . . . . . . . . . . 120 lx4d6fw . . . . . . . . . . . . . . . . . . . . . 121 lx4d6gd . . . . . . . . . . . . . . . . . . . . . 120 lx4d6jd . . . . . . . . . . . . . . . . . . . . . . 120 lx4d6jw . . . . . . . . . . . . . . . . . . . . . 121 lx4d6md . . . . . . . . . . . . . . . . . . . . . 120 lx4d6mw . . . . . . . . . . . . . . . . . . . . . 121 lx4d6nd . . . . . . . . . . . . . . . . . . . . . 120 lx4d6rd . . . . . . . . . . . . . . . . . . . . . 120 lx4d6sd . . . . . . . . . . . . . . . . . . . . . 120 lx4d6sw . . . . . . . . . . . . . . . . . . . . . 121 lx4d6ud . . . . . . . . . . . . . . . . . . . . . 120 lx4d7bd . . . . . . . . . . . . . . . . . . . . . 120 lx4d7bw . . . . . . . . . . . . . . . . . . . . . 121 lx4d7cd . . . . . . . . . . . . . . . . . . . . . 120 lx4d7cw . . . . . . . . . . . . . . . . . . . . . 121 lx4d7ed . . . . . . . . . . . . . . . . . . . . . 120 lx4d7ew . . . . . . . . . . . . . . . . . . . . . 121 lx4d7fd . . . . . . . . . . . . . . . . . . . . . 120 lx4d7fw . . . . . . . . . . . . . . . . . . . . . 121 lx4d7gd . . . . . . . . . . . . . . . . . . . . . 120 lx4d7jd . . . . . . . . . . . . . . . . . . . . . . 120 lx4d7jw . . . . . . . . . . . . . . . . . . . . . 121 lx4d7md . . . . . . . . . . . . . . . . . . . . . 120 lx4d7mw . . . . . . . . . . . . . . . . . . . . . 121 lx4d7nd . . . . . . . . . . . . . . . . . . . . . 120 lx4d7rd . . . . . . . . . . . . . . . . . . . . . 120 lx4d7sd . . . . . . . . . . . . . . . . . . . . . 120 lx4d7sw . . . . . . . . . . . . . . . . . . . . . 121 lx4d7ud . . . . . . . . . . . . . . . . . . . . . 120 lx4d8bd . . . . . . . . . . . . . . . . . . . . . 121 lx4d8ed . . . . . . . . . . . . . . . . . . . . . 121 lx4d8fd . . . . . . . . . . . . . . . . . . . . . 121 lx4d8gd . . . . . . . . . . . . . . . . . . . . . 121 lx4d8md . . . . . . . . . . . . . . . . . . . . . 121 lx4d8nd . . . . . . . . . . . . . . . . . . . . . 121 lx4d8rd . . . . . . . . . . . . . . . . . . . . . 121 lx4d8sd . . . . . . . . . . . . . . . . . . . . . 121 lx4d8ud . . . . . . . . . . . . . . . . . . . . . 121 lx4f8fw . . . . . . . . . . . . . . . . . 204, 206 lx4f8mw . . . . . . . . . . . . . . . . . 204, 206 lx4f8qw . . . . . . . . . . . . . . . . . 204, 206 lx4ff024 . . . . . . . . . . . . . . . . . . . . . 205 lx4ff048 . . . . . . . . . . . . . . . . . . . . . 205 lx4ff110 . . . . . . . . . . . . . . . . . . . . . 205 lx4ff125 . . . . . . . . . . . . . . . . . . . . . 205 lx4ff220 . . . . . . . . . . . . . . . . . . . . . 205 lx4ff250 . . . . . . . . . . . . . . . . . . . . . 205 lx4ff440 . . . . . . . . . . . . . . . . . . . . . 205 lx4fg024 . . . . . . . . . . . . . . . . . . . . . 205 lx4fg048 . . . . . . . . . . . . . . . . . . . . . 205 lx4fg110 . . . . . . . . . . . . . . . . . . . . . 205 lx4fg125 . . . . . . . . . . . . . . . . . . . . . 205 lx4fg220 . . . . . . . . . . . . . . . . . . . . . 205 lx4fg250 . . . . . . . . . . . . . . . . . . . . . 205 lx4fg440 . . . . . . . . . . . . . . . . . . . . . 205 lx4fh024 . . . . . . . . . . . . . . . . . . . . . 205 lx4fh048 . . . . . . . . . . . . . . . . . . . . . 205 lx4fh110 . . . . . . . . . . . . . . . . . . . . . 205 lx4fh125 . . . . . . . . . . . . . . . . . . . . . 205 lx4fh220 . . . . . . . . . . . . . . . . . . . . . 205 lx4fh250 . . . . . . . . . . . . . . . . . . . . . 205 lx4fh440 . . . . . . . . . . . . . . . . . . . . . 205 lx4fj048 . . . . . . . . . . . . . . . . . . . . . 205 lx4fj110 . . . . . . . . . . . . . . . . . . . . . 205 lx4fj125 . . . . . . . . . . . . . . . . . . . . . 205 lx4fj220 . . . . . . . . . . . . . . . . . . . . . 205 lx4fj250 . . . . . . . . . . . . . . . . . . . . . 205 lx4fj440 . . . . . . . . . . . . . . . . . . . . . 205 lx4fk048 . . . . . . . . . . . . . . . . . . . . . 206 lx4fk110 . . . . . . . . . . . . . . . . . . . . . 206 lx4fk125 . . . . . . . . . . . . . . . . . . . . . 206 lx4fk220 . . . . . . . . . . . . . . . . . . . . . 206 lx4fk250 . . . . . . . . . . . . . . . . . . . . . 206 lx4fk440 . . . . . . . . . . . . . . . . . . . . . 206 lx4fl048 . . . . . . . . . . . . . . . . . . . . . 206 lx4fl110 . . . . . . . . . . . . . . . . . . . . . 206 lx4fl125 . . . . . . . . . . . . . . . . . . . . . 206 lx4fl220 . . . . . . . . . . . . . . . . . . . . . 206 lx4fl250 . . . . . . . . . . . . . . . . . . . . . 206 lx4fl440 . . . . . . . . . . . . . . . . . . . . . 206 lx4fx110 . . . . . . . . . . . . . . . . . . . . . 206 lx4fx125 . . . . . . . . . . . . . . . . . . . . . 206 lx4fx220 . . . . . . . . . . . . . . . . . . . . . 206 lx4fx250 . . . . . . . . . . . . . . . . . . . . . 206 lx4fx440 . . . . . . . . . . . . . . . . . . . . . 206 lx9ff048 . . . . . . . . . . . . . . . . . . . . . 207 lx9ff110 . . . . . . . . . . . . . . . . . . . . . 207 lx9ff127 . . . . . . . . . . . . . . . . . . . . . 207 lx9ff220 . . . . . . . . . . . . . . . . . . . . . 207 lx9ff240 . . . . . . . . . . . . . . . . . . . . . 207 lx9ff380 . . . . . . . . . . . . . . . . . . . . . 207 lx9ff415 . . . . . . . . . . . . . . . . . . . . . 207 lx9ff500 . . . . . . . . . . . . . . . . . . . . . 207 lx9fg048 . . . . . . . . . . . . . . . . . . . . . 207 lx9fg110 . . . . . . . . . . . . . . . . . . . . . 207 lx9fg127 . . . . . . . . . . . . . . . . . . . . . 207 lx9fg220 . . . . . . . . . . . . . . . . . . . . . 207 lx9fg240 . . . . . . . . . . . . . . . . . . . . . 207 lx9fg380 . . . . . . . . . . . . . . . . . . . . . 207 lx9fg415 . . . . . . . . . . . . . . . . . . . . . 207 lx9fg500 . . . . . . . . . . . . . . . . . . . . . 207 lx9fh0482 . . . . . . . . . . . . . . . . . . . . 207 lx9fh1102 . . . . . . . . . . . . . . . . . . . . 207 lx9fh1272 . . . . . . . . . . . . . . . . . . . . 207 lx9fh2202 . . . . . . . . . . . . . . . . . . . . 207 lx9fh3802 . . . . . . . . . . . . . . . . . . . . 207 lx9fh5002 . . . . . . . . . . . . . . . . . . . . 207 lx9fj917 . . . . . . . . . . . . . . . . . . . . . 208 lx9fj918 . . . . . . . . . . . . . . . . . . . . . 209 lx9fj925 . . . . . . . . . . . . . . . . . . . . . 208 lx9fj926 . . . . . . . . . . . . . . . . . 208, 209 lx9fj927 . . . . . . . . . . . . . . . . . . . . . 209 lx9fj931 . . . . . . . . . . . . . . . . . . . . . 208 lx9fj932 . . . . . . . . . . . . . . . . . . . . . 209 lx9fj936 . . . . . . . . . . . . . . . . . . . . . 208 lx9fj937 . . . . . . . . . . . . . . . . . . . . . 208 lx9fj938 . . . . . . . . . . . . . . . . . 208, 209 lx9fk917 . . . . . . . . . . . . . . . . . . . . . 208 lx9fk918 . . . . . . . . . . . . . . . . . . . . . 209 lx9fk925 . . . . . . . . . . . . . . . . . . . . . 208 lx9fk926 . . . . . . . . . . . . . . . . . 208, 209 lx9fk927 . . . . . . . . . . . . . . . . . . . . . 209 lx9fk931 . . . . . . . . . . . . . . . . . . . . . 208 lx9fk932 . . . . . . . . . . . . . . . . . . . . . 209 lx9fk936 . . . . . . . . . . . . . . . . . . . . . 208 lx9fk937 . . . . . . . . . . . . . . . . . . . . . 208 lx9fk938 . . . . . . . . . . . . . . . . . 208, 209 lx9fl917 . . . . . . . . . . . . . . . . . . . . . 208 lx9fl918 . . . . . . . . . . . . . . . . . . . . . 209 lx9fl924 . . . . . . . . . . . . . . . . . . . . . 208 lx9fl925 . . . . . . . . . . . . . . . . . . . . . 209 lx9fl926 . . . . . . . . . . . . . . . . . 208, 209 lx9fl930 . . . . . . . . . . . . . . . . . . . . . 208 lx9fl931 . . . . . . . . . . . . . . . . . . 208, 209 lx9fl935 . . . . . . . . . . . . . . . . . . . . . . 208 lx9fl936 . . . . . . . . . . . . . . . . . . . . . . 208 lx9fl937 . . . . . . . . . . . . . . . . . . . . . . 209 lx9fl938 . . . . . . . . . . . . . . . . . . . . . . 208 lxd1b7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1c7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1cc7 . . . . . . . . . . . . . . . . . . . . . . 117 lxd1d7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1e7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1ee7 . . . . . . . . . . . . . . . . . . . . . . 117 lxd1f7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1fc7 . . . . . . . . . . . . . . . . . . . . . . 117 lxd1fe7 . . . . . . . . . . . . . . . . . . . . . . 117 lxd1g7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1j7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1k7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1l7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1le7 . . . . . . . . . . . . . . . . . . . . . . 117 lxd1m7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1n7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1p7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1q7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1r7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1sc7 . . . . . . . . . . . . . . . . . . . . . . 117 lxd1t7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1u7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1v7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1w7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1x7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1y7 . . . . . . . . . . . . . . . . . . . . . . . 117 lxd1z7 . . . . . . . . . . . . . . . . . . . . . . . 117 p pa1lb50 . . . . . . . . . . . . . . . . . . . . . . . 238 pa1lb75 . . . . . . . . . . . . . . . . . . . . . . . 238 pa1lb76 . . . . . . . . . . . . . . . . . . . . . . . 238 pa1lb80 . . . . . . . . . . . . . . . . . . . . . . . 238 pa1lb89 . . . . . . . . . . . . . . . . . . . . . . . 238 pa1pb50 . . . . . . . . . . . . . . . . . . . . . . 238 pa1rb50 . . . . . . . . . . . . . . . . . . . . . . 238 pn1fb50 . . . . . . . . . . . . . . . . . . . . . . 238 pr4fb00 . . . . . . . . . . . . . . . . . . . . . . 238 pr4fb0004 . . . . . . . . . . . . . . . . . . . . 237 pr4fb0005 . . . . . . . . . . . . . . . . . . . . 237 pr4fb0006 . . . . . . . . . . . . . . . . . . . . 237 pr4fb0007 . . . . . . . . . . . . . . . . . . . . 237 pr4fb0008 . . . . . . . . . . . . . . . . . . . . 237 pr4fb0009 . . . . . . . . . . . . . . . . . . . . 237 pr4fb0010 . . . . . . . . . . . . . . . . . . . . 237 pr4fb0011 . . . . . . . . . . . . . . . . . . . . 237 pr4fb0012 . . . . . . . . . . . . . . . . . . . . 237 pr4fb0014 . . . . . . . . . . . . . . . . . . . . 237 w wb1kb121 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb122 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb123 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb124 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb125 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb126 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb132 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb133 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb134 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb135 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb136 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb137 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb138 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb139 . . . . . . . . . . . . . . . . . . . . . 236 wb1kb140 . . . . . . . . . . . . . . . . . . . . . 236 w816366180111 . . . . . . . . . . . . . . . . . 137 x xby1u . . . . . . . . . . . . . . . . . . . . . . . . 114 xb5al84101 . . . . . . . . . . . . . . . . . . . . 137 xb5aa86102. . . . . . . . . . . . . . . . . . . . 137 z za2ba8602 . . . . . . . . . . . . . . . . . . . . 221 za2bz13 . . . . . . . . . . . . . . . . . . . . . . 221 zb5aa0 . . . . . . . . . . . . . . . . . . . . . . . . 165 zb5aa331 . . . . . . . . . . . . . . . . . . . . . . 165 zb5al432 . . . . . . . . . . . . . . . . . . . . . . 165 zb5a639 . . . . . . . . . . . . . . . . . . . . . . . 165 zb5ad2. . . . . . . . . . . . . . . . . . . . . . . . 165 zb5ad3. . . . . . . . . . . . . . . . . . . . . . . . 165 zb5ad5. . . . . . . . . . . . . . . . . . . . . . . . 165 zc4gm1 . . . . . . . . . . . . . . . . . . . . . . . 238 zc4gm2 . . . . . . . . . . . . . . . . . . . 237, 238 zc4gm8 . . . . . . . . . . . . . . . . . . . 237, 238 zc4gm9 . . . . . . . . . . . . . . . . . . . . . . . 238
catalog no. 8502ct9901r5/03 january 2004 ? 2001-2004 schneider electric all rights reserved replaces 8502ct9901r9/02 dated 11/02. schneider electric 8001 highway 64 east knightdale, nc 27545 1-888-squared (1-888-778-2733) www.squared.com schneider canada inc. 19 waterman avenue, m4b 1 y2 toronto, ontario 1-800-565-6699 www.schneider-electric.ca


▲Up To Search▲   

 
Price & Availability of LC1D18F7

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X